Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “siting and sizing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

IM3 Projected US Data Center Locations

IM3 Projected US Data Center Locations This dataset contains model projections of new data center facilities in the contiguous United States (CONUS) through 2035 using the CERF – Data Centers model. Data center locations are modeled across four data center electricity demand growth scenarios (low, moderate, high, higher) and five market gravity scenarios (0%, 25%, 50%, 75%, 100%). Projected locations are intended to be regional representations of feasible siting locations in the future to assess potential grid and water stress impacts. The data center load growth scenarios correspond with the rates outlined in EPRI (2024) and include 3.71%, 5%, 10%, and 15% annual growth of electricity demand for data centers from 2023 values in 37 states across the CONUS. Market gravity scenarios correspond to the relative importance of proximity to data center markets or high population areas compared to locational cost in the siting algorithm. 0% market gravity means that siting decisions were entirely determined by the locational cost in each feasible location. 100% market gravity means that only market proximity was considered when siting. Other scenarios have weight placed on both components where total weight always equals 100%. Locational cost is dependent on facility cooling type and corresponding electricity cost, taxes, and other factors. Facility cooling type is spatially determined where high water stress and/or areas with high summer wet bulb temperatures are assumed to operate with mechanical cooling for a higher fraction of the year rather than evaporative cooling. Feasible data center siting areas are based on geospatial suitability raster data developed with open-source information. The following areas are excluded from siting: Areas within 300 m of a federal airport runway or within an airport area boundary Waterbodies Areas with slope >16% Areas susceptible to sinkholes High coastal or inland flood risk areas Local, state, and federal parks, leisure areas, and cemeteries Areas >2 km away from electric substations Areas >5 km away from a municipal water supplier service area Areas >2 km away from high-speed fiber provider service territory USGS Protected Areas Database of the United States (PAD-US) GAP status 1, 2, or 3 areas US National Parks Wetlands USFWS critical habitats BIA land areas Railroads, major roadways, and minor roadways Military areas and training grounds NLCD developed lands Areas >0.8 km (0.5 miles) from NLCD developed lands Because we use open-source information, proprietary information that can influence siting decisions such as individual tax agreements with cities, detailed fiber line connectivity, electric grid power capacity agreements, and others, are not currently accounted for in the modeling process. Using specific building locations and footprints in the dataset for local planning purposes is not advised. Technical Information Geospatial data is provided in geojson format using the Albers Equal Area Conic (ESRI:102003) coordinate reference system. The datasets contain the following parameters: id - unique identification number within given scenario file growth_scenario – data center demand growth scenario market_gravity_weight – market gravity weight scenario (%) region – name of region (i.e., US State) total_cost_million_usd – locational siting cost ($million) campus_size_square_ft – total land acquired for data center facility (square ft) data_center_it_power_mw – IT power of data center facility (MW) mechanical_cooling_frac – fraction of year when data center uses mechanical cooling system water_cooling_frac– fraction of year when data center uses evaporative cooling system cooling_energy_demand_mwh – total annual facility energy demand for cooling (MWh) cooling_water_demand_mgy – total annual facility water demand for cooling (MG) cooling_water_consumption_mgy – total annual facility water consumed (MG) normalized_locational_cost – normalized total locational cost score for location normalized_gravity_score – normalized market gravity score for location weighted_siting_score – total weighted siting score of locational cost and gravity score geometry – polygon geometry of facility Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program. License This data is made available under a CCBY4.0 License Disclaimer This material was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor the United States Department of Energy, nor the Contractor, nor any or their employees, nor any jurisdiction or organization that has cooperated in the development of these materials, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness or any information, apparatus, product, software, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof, or Battelle Memorial Institute. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. PACIFIC NORTHWEST NATIONAL LABORATORYoperated byBATTELLEfor theUNITED STATES DEPARTMENT OF ENERGYunder Contract DE-AC05-76RL01830

Mongird, Kendall (ORCID:0000000328077088)↗

Expert perspectives on the wind plant of the future

Abstract Wind power technology has changed rapidly in recent years. Technology innovation, evolving power markets, and competing land and ocean uses continue to influence the design and operation of wind turbines and plants. Anticipating these trends and their impact on future facilities can inform commercial strategies and research priorities. Drawing from a recent survey of 140 of the world's foremost wind experts, we identify expectations of future wind plant design in 2035, both for onshore and offshore wind. Experts anticipate continued growth in turbine size, to 5.5 (onshore) and 17 MW (offshore), with plants located in increasingly less favorable wind and siting regimes. They expect plant sizes of 1,100 MW for fixed‐bottom and 600 MW for floating offshore wind. Experts forecast enhanced grid‐system value from wind through significant to widespread use of larger rotors, hybrid projects with batteries and hydrogen production, and more. To explain experts' perspectives on future plant design and operation, we identify five mechanisms: economies of unit, plant, and resource scale; grid‐system value economies; and production efficiencies. We characterize learning effects as a moderating influence on the strength of these mechanisms. In combination, experts predict that these design choices support levelized cost of energy reductions of 27% (onshore) and 17%–35% (floating and fixed‐bottom offshore) by 2035 compared to today, while enhancing wind energy's grid service offerings. Our findings provide a much‐needed benchmark for representing future wind technologies in power sector models and address a critical research gap by explaining the economics behind wind energy design choices.

17 WIND ENERGY↗

Vadose Zone Flow and Transport Parameters Data Package for the Hanford Site Composite Analysis

This report provides a description of the basis for the development and implementation of a conceptual model for vadose zone flow and transport for the Hanford Site composite analysis (CA) groundwater pathway analysis. The parameterization for a numerical model is intimately linked to the conceptual model framework. This report describes the basis for the selection of hydraulic and transport parameters for the hydrostratigraphic units (HSUs) identified in the 200 East and 200 West Areas. The following three-step process was used to develop the hydraulic properties and transport parameters for the CA modeling: 1. Breakdown of existing database on hydraulic properties by HSUs 2. Constitutive model parameters for laboratory, core-scale hydraulic properties 3. Upscaling for macroscopic, field-scale flow, and transport parameters This document provides data and information on the following items: A brief description and technical basis for the conceptual model selected to represent vadose zone flow and transport for the CA modeling. Variation in sediment particle size distribution for representative sites in the 200 East and West Areas. A summary of effective (upscaled) moisture retention, and saturated and unsaturated hydraulic conductivity estimates for the HSUs in the 200 East and West Areas. A summary of effective transport parameters, including sediment bulk density and macrodispersivity estimates for various HSUs. The 200 East Area B Complex perched water aquifer hydraulic properties

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hot deformation behavior of an industrially cast large grained low density austenitic steel

Hot compression testing was performed on specimens of an Fe–30Mn–9Al–1Si-0.9C-0.5Mo wt.% low density steel which were extracted from an industrial casting with large grain size (320 ± 50 μm). Grain boundaries act as nucleation sites for dynamic recrystallization in the present material and the large grain size results in fewer nucleation sites, which delays dynamic recrystallization to larger strains and/or higher temperatures and causes higher rates of work hardening relative to similar materials but with smaller grain sizes. Here, a relatively high activation energy for hot deformation of 470 ± 90 kJ mol –1 was determined from a Zener-Hollomon analysis of the flow stresses at different temperatures and strain rates, attributed in part to the large grain size.

36 MATERIALS SCIENCE↗

REopt Lite User Manual

REopt Lite evaluates the economic viability of grid-connected solar photovoltaics, wind, combined heat and power, and electric and thermal storage at commercial and small industrial sites. It allows building owners to identify the system sizes and dispatch strategies that minimize the site’s life cycle cost of energy. REopt Lite also estimates the amount of time on-site generation and storage can sustain the site's critical load during a grid outage and allows the user the choice of optimizing for energy resilience. It is primarily used to inform project development decisions and to support research on the factors that drive project feasibility for market development and policy analysis. It is available through a web interface, application programing interface, and open-source code. This user manual provides an overview of the model, including its capabilities and typical applications; inputs and outputs; economic calculations; technology descriptions; and model parameters, variables, and equations. The model is highly flexible and is continually evolving to meet the needs of each analysis. Therefore, this report is not an exhaustive description of all capabilities, but rather a summary of the core components of the model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Austin Sustainable and Holistic Integration of Energy Storage and Solar PV [Austin SHINES]. Final Report, Version 2

The Austin SHINES project and solution is a software management platform, for an electric grid with a high penetration of dispersed photovoltaic (PV) solar generation sites, which maintains the traditional power quality and reliability associated with grid service. This project developed and deployed the platform as a Distributed Energy Resource Management System (DERMS), engaging multiple advanced controls, to evaluate operation and optimization of a fleet of diverse DER assets, installed at several locations among Austin Energy’s customers and distribution system. The project also produced a methodology to create a replicable DERMS template, adaptable to other regions and market structures. Last, Austin SHINES aimed to demonstrate the solution’s methodology would enable the DER grid ecosystem to serve load at a technical cost (System Levelized Cost of Electricity, or System LCOE) of less than the U.S. Department of Energy SHINES program metric of $0.14/kWh, in a defined boundary, while enabling a high penetration of distributed PV. Research was categorized in 6 reports (Final Deliverables = FD) listed below, with titles and descriptions indicating which area of understanding was investigated: FD-1: System Levelized Cost of Electricity (System LCOE) Methodology The creation and use of the System LCOE to Serve Load metric that encompasses the holistic, system-level costs and benefits of all resources, and enables them to be evaluated based on their ability to support an efficient and low-cost integrated grid ecosystem. FD-2: Software Platform Product Description The creation of new DER control methodologies deployable within a utility-grade software platform that enable DER's to maximize their benefit within a grid, that is capable of serving load enabling a high penetration of distributed PV generation. FD-3: Optimal Design Methodology Optimal design methodologies for individual DER installations that enable utilities to determine the optimal combinations and sizing for individual DER sites. FD-4: Austin SHINES Ownership and Operation Models for DER System Performance A comparison of multiple DER aggregation and ownership methodologies including direct utility control, third-party aggregator, and autonomous. FD-5: Economic Modeling & Optimization A comparison of multiple DER technology mixes and configurations within the distribution system, providing insight into an optimal blend of technologies that best enable the distribution system to serve load at the lowest cost at high penetrations of solar. FD-6: Fielded Assets Deployed DER assets within the Austin Energy SHINES circuits. Austin SHINES provided an opening for state-of-the-art technology products to be deployed, providing a rich opportunity for improving how each of the products perform as stand-alone products, and in concert with other complementary products. The Austin SHINES project comprised of two key metrics for System LCOE: SystemLCOE_SHINES<$0.14/kWh Modeled ΔSystemLCOE_SHINES/ΔSystemLCOE_Base≥20% at same solar penetration The System LCOE calculation uses the costs of the utility-owned infrastructure as it exists today, the cost of the DERs that exist in the system today, and the cost of the purchase of energy from ERCOT wholesale markets over the course of the calendar year. All costs are on an annualized basis. The capital and operating costs are derived from the rate case, which produces a yearly cost. The net cost of energy and services imported to the system is integrated over the test year, as is the load served and solar penetration. The first metric was easily achieved by every scenario considered. The goal was set when the Department of Energy’s SHINES Funding Opportunity Announcement was written in 2015 and was a more difficult target at the time. Due mostly to rapidly declining costs for DERs and the significant decrease in the Electric Reliability Council of Texas (ERCOT) energy market prices, which results in lower net cost of energy purchases, the System LCOE is well below this target for all scenarios considered. A fleet of DERs can assume different mixtures, each of which serves the load at a different LCOE. The optimal mixture of DERs serves load at the smallest System LCOE. The second metric (hereinafter %delta metric) asks that the holistic DERMS controls reduce the incremental cost above the baseline of going to a high solar penetration future by at least 20% as compared to the case of a DER deployment with no sophisticated controls (autonomous). Many comparison sets were created throughout this project. Physical technology was installed for informing utility engineering and testing several types of operational control schemes, through the DERMS. The types of operational control which were compared for valuation of the System LCOE Metric were: Holistic control = using the full suite of the DERMS platform to decide and optimize how/why the systems operate depending on weather, market, and reliability signal input. Autonomous control = a local mode at the asset site, wherein a schedule operates the asset, with visibility into performance only No control = the baseline for comparing value against the other two types of control The types of ownership control included: Direct Utility control = the utility dispatches a signal to each asset Third-Party Aggregator = a third party aggregates a fleet of assets and the utility dispatches one signal for all Autonomous = a local mode is set for operation at the asset site, wherein a schedule operates the asset, with visibility into performance only The types of control methodologies deployable within a utility-grade software platform included: Utility Peak Load Reduction = Lower transmission cost obligation Day-Ahead Energy Arbitrage = Realize economic value through price differential Real-Time Price Dispatch = Realize economic value from real-time price spikes Voltage support = Reduce losses and increase solar generation Distribution Congestion Management = Increase local grid reliability Demand Charge Reduction = Lower customer bills and realize system benefit The fielded assets deployed for the project were: Utility Scale Kingsbery Energy Storage System: 1.5 MW / 3 MWh Li-Ion battery storage Mueller Energy Storage System: 1.75 MW / 3.2 MWh Li-Ion battery storage, 7 Energy Storage Units (250 kW each) La Loma Community Solar: 2.6 MW Commercial Scale Aggregated storage installations at 3 sites, with existing solar (300+ kW): One 18 kW / 36 kWh Li-Ion battery storage Two 72 kW / 144 kWh Li-Ion battery storage Residential Scale Aggregated storage installations: -Six stationary battery storage systems (10 kWh each) at homes with existing solar -One Electric Vehicle installed as Vehicle-to-Grid (V2G) Utility-Controlled Solar via Smart Inverters at 12 homes Autonomously-Controlled Smart Inverters at 6 homes Over the course of the project, Austin SHINES undertook installing more than 3 MW of distributed battery energy storage, smart PV inverters, a DER control platform, and other enabling technologies utilizing customer and utility locations and aggregation models. All of these resources were to be integrated and optimized at the utility level. DER assets and control methodologies were designed to achieve a credible pathway to a System LCOE for energy delivered to load of $0.14//kWh or less by 2020, while maximizing distributed solar generation and maintaining acceptable standards of power quality. The project also established a template for other regions to follow, to maximize the adoption of distributed solar PV in support of an economic and efficient grid. In total, the Austin SHINES project added value to the DER subject area in each layer of integration. From utility, to commercial to residential scales, the sheer hierarchy of communication and coordination was a significant accomplishment in addition to learnings from what these communications revealed was unique to each. Economically, the most effective method demonstrated was the criticality of planning phases. Contingencies and multiple projection scenarios helped guide the project to deploy optimal design as close as feasible, in real world conditions. The project and reports will serve public benefit by outlining specific areas of DER strategy and installation where many stakeholders and needs can be addressed with improved efficiency. Overall, communities and utilities should use the results to guide the increasing options available for powering the grid with DER, renewables, and carbon considerate energy.

14 SOLAR ENERGY↗

Going Off Grid: A Comparative Study of the Lagrangian and Eulerian Perspectives of New Particle Formation Events

New particle formation and growth (NPF&G) is the process by which ultrafine particles are formed from gas-phase precursors. NPF&G is the dominant source of global aerosol number with important influences on climate. Most observations of NPF&G events are conducted at stationary sites; however, NPF&G observed from stationary sites is influenced by gradual or rapid changes in the air masses passing over the site, complicating NPF&G analysis. In this work, we use observations and a 3D aerosol model to compare aerosol size distributions at a stationary site (Southern Great Plains [SGP] observatory, Oklahoma, USA) and along Lagrangian trajectories crossing the site. The model simulates the NPF&G events reasonably well at SGP. Using the model to compare the Lagrangian and stationary perspectives, we can explain previously unanalyzable days with some evidence of NPF&G as either non-event or analyzable NPF&G days. We find most of the unanalyzable NPF&G days are due to isolated and inhomogeneous NPF&G occurring upwind of the stationary site, often in the outflow of urban regions. Finally, we compare formation rates of 3 nm particles, growth rates, and the survival probability of 3 nm particles growing to 25 nm between the stationary and Lagrangian perspectives. Because of the much larger number of analyzable days along the Lagrangian trajectories, this perspective potentially provides more robust statistics and better characterization of NPF&G event extremes. Our method for extracting chemical/physical properties along Lagrangian trajectories from 3D models can be applied to a wide range of science questions.

O’Donnell, Samuel E. [Colorado State Univ., Fort C↗

Wind power costs driven by innovation and experience with further reductions on the horizon

The costs of wind power have declined to levels on par with or below those of conventional sources in many parts of the world. Wind power has become one of the fastest-growing sources of new electricity generation. We take stock of wind power cost evolution over the past 20 years, review methodologies commonly used for cost assessment, discuss the potential for continued cost reduction, and identify anticipated cost and value drivers. Our scope includes both onshore and offshore wind technologies. We draw from a vast body of literature on these topics to highlight key trends, approaches, and limitations. Furthermore, we discuss strategies for wind power assets to enhance their marginal economic value to the broader power system and consumers. We identify a myriad of factors that are expected to influence the future cost and value of wind power, including siting, project scale, turbine size, operational synergies, commodity prices, advancements in turbine technologies, enhanced management of the wind resource, and novel control technologies that provide value for the electricity grid. Because the common methods for forecasting future costs each have their own strengths and weaknesses, we find the best insights are elicited from a combination of methods. Overall, researchers and analysts anticipate further sizable cost reductions for onshore and offshore wind. Midrange forecasts for levelized cost of energy in 2050 are generally between $20 and $30/MWh for onshore wind and $40 and $60/MWh for offshore wind, a reduction to approximately half of today's levels. Optimistic forecasts anticipate these levels as early as 2030.

17 WIND ENERGY↗

Toho-1 β-lactamase: backbone chemical shift assignments and changes in dynamics upon binding with avibactam

Backbone chemical shift assignments for the Toho-1 β-lactamase (263 amino acids, 28.9 kDa) are reported based on triple resonance solution-state NMR experiments performed on a uniformly 2 H, 13 C, 15 N-labeled sample. These assignments allow for subsequent site-specific characterization at the chemical, structural, and dynamical levels. At the chemical level, titration with the non-β-lactam β-lactamase inhibitor avibactam is found to give chemical shift perturbations indicative of tight covalent binding that allow for mapping of the inhibitor binding site. At the structural level, protein secondary structure is predicted based on the backbone chemical shifts and protein residue sequence using TALOS-N and found to agree well with structural characterization from X-ray crystallography. At the dynamical level, model-free analysis of 15 N relaxation data at a single field of 16.4 T reveals well-ordered structures for the ligand-free and avibactam-bound enzymes with generalized order parameters of ~0.85. Complementary relaxation dispersion experiments indicate that there is an escalation in motions on the millisecond timescale in the vicinity of the active site upon substrate binding. The combination of high rigidity on short timescales and active site flexibility on longer timescales is consistent with hypotheses for achieving both high catalytic efficiency and broad substrate specificity: the induced active site dynamics allows variously sized substrates to be accommodated and increases the probability that the optimal conformation for catalysis will be sampled.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Energetics of Ag Adsorption on and Adhesion to Rutile TiO 2 (100) Studied by Microcalorimetry

The adsorption and adhesion energies of vapor-deposited Ag on rutile TiO 2 (100) films have been measured using single crystal adsorption calorimetry (SCAC) and He + low energy ion scattering spectroscopy (LEIS). Ag grows as three-dimensional (3D) nanoparticles at 300 and 100 K. The saturation particle density is 8 × 10 16 particles/m 2 at 300 K and 2.5 × 10 17 particles/m 2 at 100 K. The differential heat of adsorption starts low, increases with Ag coverage, and finally approaches the sublimation enthalpy of Ag at both 300 and 100 K. At 300 K, the differential heat of adsorption starts from 208 kJ/mol and rises rapidly to 265 kJ/mol by 1 ML. At 100 K, Ag grows nanoparticles with smaller particle size on the terraces, while at 300 K, the Ag nanoparticles have bigger particle size and grow on step edges with stronger binding strength to the nanoparticles. Thus, the heat of Ag adsorption at 100 K starts at 141 kJ/mol (near the monomer size limit on terrace sites) and remains lower than that at 300 K until 1.5 ML. Here, the adhesion energy of Ag(solid) to rutile TiO 2 (100) is found to be large (~2.44 J/m 2 ), supporting a trend of decreasing adhesion energy with the enthalpy of oxide reduction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Chemical versus physical pressure effects on the structure transition of bilayer nickelates

The observation of high-T c superconductivity (HTSC) in concomitant with pressure-induced orthorhombic-tetragonal structural transition in bilayer La 3 Ni 2 O 7 has sparked hopes of achieving HTSC by stabilizing the tetragonal phase at ambient pressure. Chemical pressure, introduced by replacing La 3+ with smaller rare-earth R 3+ has been considered as a potential route. However, our experimental and theoretical investigation reveals that such substitutions, despite causing lattice contraction, actually produce stronger orthorhombic distortions, requiring higher pressures for the structural transition. A linear extrapolation of P c versus the average size of A-site cations (<$r_A$>), yields a putative critical value of (<$r_A$>) ≈ 1.23 Å for P c ≈ 1 bar. The negative correlation between P c and (<$r_A$>) indicates that replacing La 3+ with smaller R 3+ ions is unlikely to reduce P c to ambient pressure. Instead, substituting La 3+ with larger cations like Sr 2+ or Ba 2+ might be a feasible approach. Our results provide guidance for realizing ambient-pressure HTSC in bilayer nickelates.

36 MATERIALS SCIENCE↗

On-demand formation of Lewis bases for efficient and stable perovskite solar cells

In the fabrication of FAPbI 3 -based perovskite solar cells, Lewis bases play a crucial role in facilitating the formation of the desired photovoltaic α-phase. However, an inherent contradiction exists in their role: they must strongly bind to stabilize the intermediate δ-phase, yet weakly bind for rapid removal to enable phase transition and grain growth. To resolve this conflict, we introduced an on-demand Lewis base molecule formation strategy. This approach utilized Lewis-acid-containing organic salts as synthesis additives, which deprotonated to generate Lewis bases precisely when needed and could be reprotonated back to salts for rapid removal once their role is fulfilled. This method promoted the optimal crystallization of α-phase FAPbI 3 perovskite films, ensuring the uniform vertical distribution of A-site cations, larger grain sizes and fewer voids at buried interfaces. Perovskite solar cells incorporating semicarbazide hydrochloride achieved an efficiency of 26.1%, with a National Renewable Energy Laboratory-certified quasi-steady-state efficiency of 25.33%. These cells retained 96% of their initial efficiency after 1,000 h of operation at 85 °C under maximum power point tracking. Additionally, mini-modules with an aperture area of 11.52 cm 2 reached an efficiency of 21.47%. This strategy is broadly applicable to all Lewis-acid-containing organic salts with low acid dissociation constants and offers a universal approach to enhance the performance of perovskite solar cells and modules.

14 SOLAR ENERGY↗

Modulation of CO 2 adsorption in novel pillar-layered MOFs based on carboxylate–pyrazole flexible linker

Metal–organic frameworks (MOFs) have attracted significant attention as sorbents due to their high surface area, tunable pore volume and pore size, coordinatively unsaturated metal sites, and ability to install desired functional groups by post-synthetic modification. Herein, we report three new MOFs with pillar–paddlewheel structures that have been synthesized solvothermally from the mixture of the carboxylate–pyrazole flexible linker (H 2 L), 4,4-bipyridine (BPY)/triethylenediamine (DABCO), and Zn(II)/Cu(II) ions. The MOFs obtained, namely [Zn II (L)BPY], [Cu II (L)BPY], and [Cu II (L)DABCO], exhibit two-fold interpenetration and dinuclear paddle–wheel nodes. The Zn(II)/Cu(II) cations are coordinated by two equatorial L linkers that result in two-dimensional sheets which in turn are pillared by BPY or DABCO in the perpendicular direction to obtain a neutral three-dimensional framework that shows one-dimensional square channels. The three pillar-layered MOFs were characterized as microporous materials showing high crystalline stability after activation at 120 °C and CO 2 adsorption. All MOFs contain uncoordinated Lewis basic pyrazole nitrogen atoms in the framework which have an affinity toward CO 2 and hence could potentially serve as CO 2 adsorption material. The CO 2 uptake capacity was initially enhanced by replacing Zn with Cu and then replacing the pillar, going from BPY to DABCO. Overall, all the MOFs exhibit low isosteric heat (Q st ) of adsorption which signifies an advantage due to the energy required for the adsorption and regeneration processes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Near-infrared nanosensors enable optical imaging of oxytocin with selectivity over vasopressin in acute mouse brain slices

Oxytocin plays a critical role in regulating social behaviors, yet our understanding of its function in both neurological health and disease remains incomplete. Real-time oxytocin imaging probes with spatiotemporal resolution relevant to its endogenous signaling are required to fully elucidate oxytocin’s role in the brain. Herein, we describe a near-infrared oxytocin nanosensor (nIROXT), a synthetic probe capable of imaging oxytocin in the brain without interference from its structural analogue, vasopressin. nIROXT leverages the inherent tissue-transparent fluorescence of single-walled carbon nanotubes (SWCNT) and the molecular recognition capacity of an oxytocin receptor peptide fragment to selectively and reversibly image oxytocin. We employ these nanosensors to monitor electrically stimulated oxytocin release in brain tissue, revealing oxytocin release sites with a median size of 3 µm in the paraventricular nucleus of C57BL/6 mice, which putatively represents the spatial diffusion of oxytocin from its point of release. These data demonstrate that covalent SWCNT constructs, such as nIROXT, are powerful optical tools that can be leveraged to measure neuropeptide release in brain tissue.

Science & Technology - Other Topics↗

Accurate localization of Kosterlitz-Thouless-type quantum phase transitions for one-dimensional spinless fermions

We investigate the charge-density wave (CDW) transition for one-dimensional spinless fermions at half band filling with nearest-neighbor electron transfer amplitude t and interaction V. The model is equivalent to the anisotropic XXZ Heisenberg model for which the Bethe Ansatz provides an exact solution. For V>V c =2t, the CDW order parameter and the single-particle gap are finite but exponentially small, as is characteristic for a Kosterlitz-Thouless transition. It is notoriously difficult to locate such infinite-order phase transitions in the phase diagram using approximate analytical and numerical approaches. Second-order Hartree-Fock theory is qualitatively applicable for all interaction strengths, and predicts the CDW transition to occur at V$^{(2)}_{c,2}$≈1.5t. Second-order Hartree Fock theory is almost variational because the density of quasiparticle excitations is small. We apply the density-matrix renormalization group (DMRG) for periodic boundary conditions for system sizes up to 514 sites, which permits a reliable extrapolation of all physical quantities to the thermodynamic limit, apart from the critical region. We investigate the ground-state energy, the gap, the order parameter, the momentum distribution, the quasiparticle density, and the density-density correlation function to locate V c from the DMRG data. In conclusion, tracing the breakdown of the Luttinger liquid and the peak in the quasiparticle density at the band edge permits us to reproduce V c with an accuracy of one percent.

1-dimensional spin chains↗

Modeling Exhaust-Generated Aerodynamic Pressure Loads on Airfield Matting Repair Systems

Airfield matting systems are commonly used for rapid repair of damaged runways to facilitate continuity of critical operations. Under normal service conditions, matting repair systems are subject not only to wheel loads exerted by airfield traffic but also to aerodynamic pressure loads resulting from high-speed, turbulent exhaust plumes produced by jets during taxi and take-off. Matting systems employed by the U.S. Air Force have been tested with respect to wheel loads, but probabilities of failure because of pressure loads produced by jet exhaust have not yet been established. This study presents a numerical approach for preliminary estimation of worst-case matting anchor forces resulting from exhaust-generated pressure loads. Using a two-dimensional computational fluid dynamics model, system behavior is evaluated by means of a parametric study of six system variables, of which the most significant are: (1) distance between engine and matting, (2) depth of cavity openings at matting edges, and (3) engine exhaust velocity. The results demonstrate that matting systems are likely to experience net uplift in typical service scenarios, driven by the combined effects of flow separation and cavity pressurization. Worst-case anchor pull-out forces, computed according to a tributary-area approach, are estimated to fall in the range of 130 lb (581 N) to 979 lb (4,350 N), depending on assumed load-sharing behavior among anchors and the size of the repair site. Field testing of instrumented matting systems during jet taxi and take-off sequences is recommended as the best next step toward understanding system behavior.

Engineering↗

AmeriFlux FLUXNET-1F US-Tw5 East Pond Wetland

This is the AmeriFlux Management Project (AMP) created FLUXNET-1F version of the carbon flux data for the site US-Tw5 East Pond Wetland. This is the FLUXNET version of the carbon flux data for the site US-Tw5 East Pond Wetland produced by applying the standard ONEFlux (1F) software. Site Description - The Twitchell Wetland site is a 6.5 acre restored wetland on Twitchell Island, that is managed by the California Department of Water Resources (DWR) and the U.S. Geological Survey (USGS). In the fall of 1997, the site was permanently flooded to a depth of approximately 55 cm. The wetland remained fairly unvegetated in patches increasing in size towards the east. The site underwent a major disturbance in 2013 when the vegetation was removed to seed a nearby restored wetland. A flux tower equipped to analyze energy, H2O, CO2, and CH4 fluxes was installed on April 17, 2018.

Valach, Alex↗

Evaluate Distributed Energy Technologies for Cost Savings and Resilience With REopt Lite

NREL's REopt Lite TM web tool evaluates the economics of grid connected photovoltaics (PV), wind, and battery storage at a site. It allows users to identify the system sizes and battery dispatch strategy that minimize a site's life cycle cost of energy, and it estimates the amount of time a PV, wind, battery, and diesel generator system can sustain the site's critical load during a grid outage.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗