Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “single-axis tracking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

86 records · Page 5

Tracking with head position using an electrooptical monitor

An electrooptical head-position monitoring system was designed and built and is used in single-axis and three-axis 'hands-off' control tasks. The monitor consists of a transparent plexiglass body-fixed helmet provided with a set of eight silicon photodetectors sensing pitch, roll, and yaw motions of the head. Two light-emitting diodes, attached to the pilot's helmet liner, provide the ac modulated near infrared radiation. Head control is compared with conventional manual control for single-axis and three-axis tracking tasks. Both performance curves and describing functions are presented.

Chouet, B. A.↗

Predicting Instability and the Effect of Wind Loading on Single-Axis Trackers

As PV modules continue to trend toward larger, thinner, and more flexible forms they grow more susceptible to damage from dynamic wind loading. As a result, understanding the impact of wind on PV systems, particularly when mounted on solar-tracking hardware, and identifying robust, stable array layouts and stow strategies is becoming increasingly important for the PV community. In our ongoing DuraMAT project, we are developing an open-source software package, PVade (PV aerodynamic design engineering), to simulate the cascading fluid-structure interaction that occurs within solar-tracking arrays to enable researchers to test hardware, layout, and tracker control changes, leading to enhanced stability and a reduction in wind-driven damage. We will give an overview of the PVade software, highlighting recent user-interface and algorithm developments, before presenting the latest outcomes from our ongoing validation campaign in which we analyze and compare with experimental data obtained from a DuraMAT 1 project. From there, we will present simulated results from a larger, multi-row array and highlight relationships between varying tracker angles and stability as measured by different experimentally validated metrics.

fluid structure interaction↗

Machine learning for photovoltaic single axis tracker fault detection and classification

More than 81% of the annual capacity of utility-scale photovoltaic (PV) power plants in the U.S. use single-axis trackers (SATs) due to SATs delivering 4% in capacity factor on average over fixed-array systems. However, SATs are subject to faults, such as software misconfigurations and mechanical failures, resulting in suboptimal tracking. If left undetected, the overall power yield of the PV power plant is reduced significantly. Minimizing downtime and ensuring efficient operation of SATs requires robust detection and diagnosis mechanisms for SAT faults. We present a machine learning framework for implementing real-time SAT fault detection and classification. Our implementation of the proposed framework reliably identifies measurements taken from a test PV system undergoing emulated SAT faults relative to state-of-the-art algorithms and produces nearly zero false positives on our testing days. Code and data are available at https://pvpmc.sandia.gov/tools.

Fault classification↗

Estimation and identification study for flexible vehicles

Techniques are studied for the estimation of rigid body and bending states and the identification of model parameters associated with the single-axis attitude dynamics of a flexible vehicle. This problem is highly nonlinear but completely observable provided sufficient attitude and attitude rate data is available and provided all system bending modes are excited in the observation interval. A sequential estimator tracks the system states in the presence of model parameter errors. A batch estimator identifies all model parameters with high accuracy.

Jazwinski, A. H.↗

A laboratory simulation of a single-axis dual-level precision pointing system

The laboratory simulation of a scaled single-axis dual-level control system for a large space telescope is demonstrated. The dual-level control system consists of a coarse-body-pointing system and a fine-pointing system, which uses an image motion compensator, an image dissector tube, and digital electronics. The results of the simulation indicate that the dual-level system can be used to provide tracking capability within one-tenth of a diffraction-limited image diameter of a 3-meter f/100 telescope for stars up to a +12.3 visual magnitude.

Bullock, G. F.↗

U.S. Photovoltaic Prices and Cost Breakdowns. Q1 2015 Benchmarks for Residential, Commercial, and Utility-Scale Systems

The price of photovoltaic (PV) systems in the United States (i.e., the cost to the system owner) has continued to decline across all major market sectors. This report provides a Q1 2015 update regarding the prices of residential, commercial, and utility scale PV systems, based on an objective methodology that closely approximates the book value of a PV system. Several cases are benchmarked to represent common variations in business models, labor rates, and system architecture choice. We estimate a weighted-average cash purchase price of $3.09/W for residential scale rooftop systems, $2.15/W for commercial scale rooftop systems, $1.77/W for utility scale systems with fixed mounting structures, and $1.91/W for utility scale systems using single-axis trackers. All systems are modeled assuming standard-efficiency, polycrystalline-silicon PV modules, and further assume installation within the United States.

14 SOLAR ENERGY↗

Slew-induced deformation shaping

Computed torques for pointing and tracking require compensation for slew-induced structural, forebody/aftbody, or optical train alignment deformations. Thus even if only line-of-sight variables are to be commanded, full state feedback is needed. The solution proposed is to decouple by feedforward of the line-of-sight slew dynamics into the deformation control loop. It is shown how arbitrarily few actuators are needed for such deformation shaping, at the cost of higher differentiability of the reference line-of-sight dynamics. The low-rate, single-axis case is developed in detail, and its extension to high rates and multiple axes by global feedback linearization is outlined.

Dwyer, T. A. W., III↗

In-flight scale/distortion calibration of the Hubble Space Telescope fixed-head star trackers

This paper describes an in-flight scale and distortion calibration procedure that has been developed for the Ball Aerospace Systems Division Fixed-Head Star Trackers (FHST's) used on the Hubble Space Telescope (HST). The FHST is a magnetically focused and deflected imaging sensor that is designed to track stars as faint as m(sub v) = 5.7 over an 8 degree by 8 degree field of view. Raw FHST position measurements are accurate to approximately 200 arcseconds, but this can be improved to 10-15 arcseconds by processing the raw measurements through calibration polynomials that correct for flat field, temperature intensity, and magnetic field effects. The coefficients for these polynomials were initially determined using ground test data. On HST the use of three FHST's is an integral part of the preliminary attitude update procedures required before the acquisition of guide stars for science observations. To this end, FHST-based attitude determination having single-axis errors no worse than 22 arcseconds (1 sigma) is required. In early 1991 it became evident that one of the HST FHST's was experiencing a significant change in its optical scale. By mid-1993 the size of this error had grown to a point that, if not corrected, it would correspond to a maximum position error on the order of 100 arcseconds. Subsequent investigations demonstrated that substantial, uncompensated cubic distortion effects had also developed, the maximum contribution to position errors from the cubic terms being on the order of 30 arcseconds. To ensure accurate FHST-based attitude updates, procedures have been developed to redetermine the FHST scale and distortion calibration coefficients based on in-flight data gathered during normal HST operations. These scale and distortion calibrations have proven very effective operationally, and procedures are in place to monitor FHST calibration changes on a continuing basis.

Mccutcheon, R.↗

An ATP System for Deep-Space Optical Communication

An acquisition, tracking, and pointing (ATP) system is proposed for aiming an optical-communications downlink laser beam from deep space. In providing for a direction reference, the concept exploits the mature technology of star trackers to eliminate the need for a costly and potentially hazardous laser beacon. The system would include one optical and two inertial sensors, each contributing primarily to a different portion of the frequency spectrum of the pointing signal: a star tracker (<10 Hz), a gyroscope (<50 Hz), and a precise fluid-rotor inertial angular-displacement sensor (sometimes called, simply, "angle sensor") for the frequency range >50 Hz. The outputs of these sensors would be combined in an iterative averaging process to obtain high-bandwidth, high-accuracy pointing knowledge. The accuracy of pointing knowledge obtainable by use of the system was estimated on the basis of an 8-cm-diameter telescope and known parameters of commercially available star trackers and inertial sensors: The single-axis pointing-knowledge error was found to be characterized by a standard deviation of 150 nanoradians - below the maximum value (between 200 and 300 nanoradians) likely to be tolerable in deep-space optical communications.

Lee, Shinhak↗

Development of a three-dimensionally movable phantom system for dosimetric verifications

The authors developed a three-dimensionally movable phantom system (3D movable phantom system) which can reproduce three-dimensional movements to experimentally verify the impact of radiotherapy treatment-related movements on dose distribution. The phantom system consists of three integrated components: a three-dimensional driving mechanism (3D driving mechanism), computer control system, and phantoms for film dosimetry. The 3D driving mechanism is a quintessential part of this system. It is composed of three linear-motion tables (single-axis robots) which are joined orthogonally to each other. This mechanism has a motion range of 100 mm, with a maximum velocity of 200 mm/s in each dimension, and 3D motion ability of arbitrary patterns. These attributes are sufficient to reproduce almost all organ movements. The positional accuracy of this 3D movable phantom system in a state of geostationary is less than 0.1 mm. The maximum error in terms of the absolute position on movement was 0.56 mm. The positional reappearance error on movement was up to 0.23 mm. The observed fluctuation of time was 0.012 s in the cycle of 4.5 s of oscillation. These results suggested that the 3D movable phantom system exhibited a sufficient level of accuracy in terms of geometry and timing to reproduce interfractional organ movement or setup errors in order to assess the influence of these errors on high-precision radiotherapy such as stereotactic irradiation and intensity-modulated radiotherapy. In addition, the authors 3D movable phantom system will also be useful in evaluating the adequacy and efficacy of new treatment techniques such as gating or tracking radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Power optimal single-axis articulating strategies

Power optimal single axis articulating PV array motion for Space Station Freedom is investigated. The motivation is to eliminate one of the articular joints to reduce Station costs. Optimal (maximum power) Beta tracking is addressed for local vertical local horizontal (LVLH) and non-LVLH attitudes. Effects of intra-array shadowing are also presented. Maximum power availability while Beta tracking is compared to full sun tracking and optimal alpha tracking. The results are quantified in orbital and yearly minimum, maximum, and average values of power availability.

Kumar, Renjith R.↗

Overview of the MSTI 2 on-orbit alignment

The Miniature Sensor Technology Integration (MSTI) 2 Spacecraft is a small 3-axis stabilized spacecraft designed to track mid-range missiles and estimate their state vectors. In order to accurately estimate the target state vector, the MSTI 2 spacecraft must have highly accurate knowledge of its own attitude. Errors in its attitude knowledge arise primarily from the errors in its Attitude Control System (ACS) sensors. The ACS sensors on the spacecraft include a scanning Earth Sensor (ES), a Sun Sensor (SS), and two 2-axis gyros. The On-Orbit Alignment (OOA) generated an error map of the ES and estimated the biases of the SS and the misalignment of the gyros. This paper discusses some of the error sources, and the techniques used to reduce the effects of these errors. The payload carried by the MSTI2 spacecraft is a high fidelity camera, which was aimed at the target using gimballed mirrors. By aiming it at a celestial target, the payload was used as a high-accuracy single-axis attitude reference. This attitude reference was compared to the attitude reference of the ACS sensors, and the errors were attributed to the ACS sensors.

Rygaard, Christopher A.↗

Human Tracking Performance in Uncoupled and Coupled Two-Axis Systems

This report presents tile results of an experimental and analytical study of human performance in uncoupled and coupled control systems. Human pilot performance in single and two-axis systems was mathematically modeled by linear second-order describing functions. Model parameters were determined using model matching techniques. Analysis of the models showed that the amplitude ratio and phase lead of the describing function increased with training indicating an increase in open loop bandwidth. The phase margin also decreased with training. Increasing the plant lag time constant resulted in an increase in the model lead time constant and a decrease in the zero frequency gain. No significant difference was found to exist in the normalized tracking error per axis between the two-axis tasks and the single-axis tasks. However tile model lead time constant was significantly greater in two-axis tracking. Manual tracking of two-axis systems with cross-coupling was studied experimentally and analytically. Approximate methods for modeling two-axis performance were developed and checked using a precise spectral analysis approach. Coupled and uncoupled, symmetrical and asymmetrical two-axis performance was compared. The results show that modeling of cross-coupled systems is feasible and that trained subjects are capable of decoupling the axes of some systems. A methodology study compared the identification performance of continuous, iterative, and extrapolation model matching techniques. An iterative technique employing sensitivity equations for the generation of influence coefficients was found to be the best technique due to its excellent identification accuracy and ease of implementation. Convergence in iterative techniques can be improved substantially by equalizing the parameter adjustment rates and limiting the maximum correction per iteration.

Todosiev, E. P.↗