A High-Speed, Event-Driven, Active Pixel Sensor Readout for Photon-Counting Microchannel Plate Detectors

Silicon array readouts for microchannel plate intensifiers offer several attractive features. In this class of detector, the electron cloud output of the MCP intensifier is converted to visible light by a phosphor; that light is then fiber-optically coupled to the silicon array. In photon-counting mode, the resulting light splashes on the silicon array are recognized and centroided to fractional pixel accuracy by off-chip electronics. This process can result in very high (MCP-limited) spatial resolution for the readout while operating at a modest MCP gain (desirable for dynamic range and long term stability). The principal limitation of intensified CCD systems of this type is their severely limited local dynamic range, as accurate photon counting is achieved only if there are not overlapping event splashes within the frame time of the device. This problem can be ameliorated somewhat by processing events only in pre-selected windows of interest or by using an addressable charge injection device (CID) for the readout array. We are currently pursuing the development of an intriguing alternative readout concept based on using an event-driven CMOS Active Pixel Sensor. APS technology permits the incorporation of discriminator circuitry within each pixel. When coupled with suitable CMOS logic outside the array area, the discriminator circuitry can be used to trigger the readout of small sub-array windows only when and where an event splash has been detected, completely eliminating the local dynamic range problem, while achieving a high global count rate capability and maintaining high spatial resolution. We elaborate on this concept and present our progress toward implementing an event-driven APS readout.

Kimble, Randy A.↗

A High-Speed, Event-Driven, Active Pixel Sensor Readout for Photon-Counting Microchannel Plate Detectors

Silicon array readouts for microchannel plate intensifiers offer several attractive features. In this class of detector, the electron cloud output of the MCP intensifier is converted to visible light by a phosphor; that light is then fiber-optically coupled to the silicon array. In photon-counting mode, the resulting light splashes on the silicon array are recognized and centroided to fractional pixel accuracy by off-chip electronics. This process can result in very high (MCP-limited) spatial resolution while operating at a modest MCP gain (desirable for dynamic range and long term stability). The principal limitation of intensified CCD systems of this type is their severely limited local dynamic range, as accurate photon counting is achieved only if there are not overlapping event splashes within the frame time of the device. This problem can be ameliorated somewhat by processing events only in pre-selected windows of interest of by using an addressable charge injection device (CID) for the readout array. We are currently pursuing the development of an intriguing alternative readout concept based on using an event-driven CMOS Active Pixel Sensor. APS technology permits the incorporation of discriminator circuitry within each pixel. When coupled with suitable CMOS logic outside the array area, the discriminator circuitry can be used to trigger the readout of small sub-array windows only when and where an event splash has been detected, completely eliminating the local dynamic range problem, while achieving a high global count rate capability and maintaining high spatial resolution. We elaborate on this concept and present our progress toward implementing an event-driven APS readout.

Kimble, Randy A.↗

Experimental overview about LANL contributions to the Electron-Ion Collider

This report is a request from the LANL team to design and build the Forward Silicon Tracker (FST) for the Electron-Ion Collider (EIC). The report highlights past accomplishments of LANL and seeks DOE support for continued work for the EIC, including silicon detector R&D; silicon tracker construction and operation; heavy flavor physics development and data analysis.

43 PARTICLE ACCELERATORS↗

A Custom Low-Noise Silicon Photodiode Detector Designed for Use With X-Ray Capillary Optics

We present the first results of a custom low-noise silicon photodiode detector designed for use with X-ray capillary optics. This system is intended to perform as a smaller, lighter, and low-powered alternative to currently existing X-ray telescope technologies. The detector has an active area with a diameter of 100 μm, and its small size leads to a low capacitance of well under 1 pF and a leakage current of 1 pA or less at the depletion voltage. We tested the detector with both a discrete preamp and an ultralow-noise front-end application-specific integrated circuit (ASIC). The front-end ASIC, developed at Brookhaven National Laboratory, was designed for low-capacitance detectors but had not been previously tested with a detector. Here, we discuss the detector design, the experimental setup, and the resulting detector performance. Using radioactive laboratory sources, we measure a full-width at half-maximum (FWHM) of 211 ± 8 eV at 5.9 keV with the ASIC and are able to set the threshold as low as 0.6 keV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ground Calibration of the Silicon Drift Detectors for NICER

The Neutron star Interior Composition ExploreR (NICER) is set to be deployed on the International Space Station (ISS) in early 2017. It will use an array of 56 Silicon Drift Detectors (SDDs) to detect soft X-rays (0.2 - 12 keV) with 100 nanosecond timing resolution. Here we describe the e ort to calibrate the detectors in the lab primarily using a Modulated X-ray Source (MXS). The MXS that was customized for NICER provides more than a dozen emission lines spread over the instrument bandwidth, providing calibration measurements for detector gain and spectral resolution. In addition, the fluorescence source in the MXS was pulsed at high frequency to enable measurement of the delay due to charge collection in the silicon and signal processing in the detector electronics. A second chamber, designed to illuminate detectors with either 55Fe, an optical LED, or neither, provided additional calibration of detector response, optical blocking, and effectiveness of background rejection techniques. The overall ground calibration achieved total operating time that was generally in the range of 500-1500 hours for each of the 56 detectors.

Silicon Drift Detectors↗

Low temperature process for diode termination of fully depleted high resistivity silicon radiation detectors that can be used for shallow entrance windows and thinned sensors

Fabrication of vertical diodes for radiation sensing using a low temperature microwave anneal is provided. This kind of anneal allows the back side processing to be performed after the front side processing is done without damaging the front side structures. This enables a simplified fabrication of thinned detectors compared to a conventional silicon on insulator process. Another feature that this technology enables is a thin entrance window for a detector that also serves as the doped diode termination. Such thin entrance windows are especially suitable for detection of low energy radiation.

Kenney, Christopher J.↗

Conceptual study of a two-layer silicon pixel detector to tag the passage of muons from cosmic sources through quantum processors

Abstract Recent studies in quantum computing have shown that quantum error correction with large numbers of physical qubits are limited by ionizing radiation from high-energy particles. Depending on the physical setup of the quantum processor, the contribution of muons from cosmic sources can constitute a significant fraction of these interactions. As most of these muons are difficult to stop, we perform a conceptual study of a two-layer silicon pixel detector to tag their hits on a solid-state quantum processor instead. With a typical dilution refrigerator geometry model, we find that efficiencies greater than 50% are most likely to be achieved if at least one of the layers is operated at the deep-cryogenic (<1 K) flanges of the refrigerator. Following this finding, we further propose a novel research program that could allow the development of silicon pixel detectors that are fast enough to provide input to quantum error correction algorithms, can operate at deep-cryogenic temperatures, and have very low power consumption.

Instruments & Instrumentation↗

Why would you put a flashlight in a dark matter detector?

Silicon photomultipliers (SiPMs) are solid-state, single-photon sensitive, pixelated sensors whose usage for scintillation detection has rapidly increased over the past decade. It is known that the avalanche process within the device, which renders a single photon detectable, can also generate secondary photons which may be detected by a separate device. This effect, known as external crosstalk, could potentially degrade the science goals of future xenon dark matter experiments. In this article, we measure the effect of external crosstalk in a dual-phase, liquid xenon time projection chamber fully instrumented with SiPMs. We then consider the implications for a future xenon dark matter experiment utilizing SiPMs and discuss possible solutions.

47 OTHER INSTRUMENTATION↗

Radiation Tests of the Extravehicular Mobility Unit Space Suit for the International Space Station Using Energetic Protons

Measurements using silicon detectors to characterize the radiation transmitted through the EMU space suit and a human phantom have been performed using 155 and 250 MeV proton beams at LLUMC. The beams simulate radiation encountered in space, where trapped protons having kinetic energies on the order of 100 MeV are copious. Protons with 100 MeV kinetic energy and above can penetrate many centimeters of water or other light materials, so that astronauts exposed to such energetic particles will receive doses to their internal organs. This dose can be enhanced or reduced by shielding - either from the space suit or the self-shielding of the body - but minimization of the risk depends on details of the incident particle flux (in particular the energy spectrum) and on the dose responses of the various critical organs. Data were taken to characterize the beams and to calibrate the detectors using the beam in a treatment room at LLUPTF, in preparation for an experiment with the same beams incident on detectors placed in a human phantom within the EMU suit. Nuclear interactions of high-energy protons in various materials produce a small flux of highly ionizing, low-energy secondary radiation. Secondaries are of interest for their biological effects, since they cause doses and especially dose-equivalents to increase relative to the values expected simply from ionization energy loss along the Bragg curve. Because many secondaries have very short ranges, they are best measured in passive track detectors such as CR-39. The silicon detector data presented here are intended to supplement the CR-39 data in regions where silicon has greater sensitivity, in particular the portion of the LET spectrum below 5 keV/micron. The results obtained in this study suggest that optimizing the radiation shielding properties of space suits is a formidable task. The naive assumption that adding mass can reduce risk is not supported by the data, which show that reducing the dose delivered at or near the skin by low-energy particles may increase the dose delivered by energetic particles to points deeper in the body.

Zeitlin, C.↗

Preliminary benchmarks and analysis of boundary conditions in a trenched microstructured silicon radiation detector

Microstructured neutron detectors have the benefit of enhanced neutron detection efficiency as compared to planar devices, achieved by etching 6 LiF-filled trenches on the top surface of a silicon PIN diode. This sensor geometry results in a complex electric field distribution and depletion characteristics within the diode under reverse bias. For the first time on record, the effects of a fixed oxide charge on the microstructured device depletion characteristics and mobile carrier transport is investigated. Prototype detectors were fabricated with non-conformal surface doping. Capacitance voltage and current voltage measurements were performed for these prototypes and compared with COMSOL Multiphysics simulations. A spectral response from an 241Am alpha particle source was acquired and analyzed. It was found that monoenergetic alpha particles produce three prominent peaks in the pulse height spectrum output by the device. The peaks were confirmed by simulations to correlate with dead layers and incident trajectories into the microstructure. It was also found that significant differences in pulse rise time result, corresponding with events arriving in a low-field region in the fins and a high-field region in the bulk. Geant4 was utilized for radiation transport, interaction modeling, and benchmarking the spectral data. The results of this simulation work provide confidence in the ability to attain and benchmark electrical characteristics and spectral data for semiconductor radiation detectors employing complex microstructures.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of a Silicon Drift Detector Array: An X-Ray Fluorescence Spectrometer for Remote Surface Mapping

Over the past three years NASA Marshall Space Flight Center has been collaborating with Brookhaven National Laboratory to develop a modular Silicon Drift Detector (SDD) X-Ray Spectrometer (XRS) intended for fine surface mapping of the light elements of the moon. The value of fluorescence spectrometry for surface element mapping is underlined by the fact that the technique has recently been employed by three lunar orbiter missions; Kaguya, Chandrayaan-1, and Chang e. The SDD-XRS instrument we have been developing can operate at a low energy threshold (i.e. is capable of detecting Carbon), comparable energy resolution to Kaguya (<150 eV at 5.9 keV) and an order of magnitude lower power requirement, making much higher sensitivities possible. Furthermore, the intrinsic radiation resistance of the SDD makes it useful even in radiation-harsh environments such as that of Jupiter and its surrounding moons.

Gaskin, Jessica A.↗

EMPHATIC Silicon Strip Detector Efficiencies

EMPHATIC is an experiment at Fermilab which aims to reduce current neutrino flux uncertainties. This report discusses the limitations current neutrino flux uncertainties places on large scale neutrino experiments, provides background on the EMPHATIC experiment, and details the project of determining the efficiency of the Silicon Strip Detectors (SSDs) used in EMPHATIC. As part of the data analysis process and in order to increase the accuracy of EMPHATIC’s simulations a representation of efficiency of each SSD is required. To achieve this a data-driven analysis was performed on EMPHATIC's collected data using the Root and Art frameworks. Visual and numerical representations of efficiency were determined. The average efficiency over all SSDs is 98.58\%, however this number deflated as it includes known bad channels.

Olson, Virginia [Illinois U., Urbana (main)]↗

Determining the Efficiency of EMPHATICs Silicon Strip Detectors (SSDs)

EMPHATIC is an experiment at Fermilab which aims to reduce current neutrino flux uncertainties. This report discusses the limitations current neutrino flux uncertainties places on large scale neutrino experiments, provides background on the EMPHATIC experiment, and details the project of determining the efficiency of the Silicon Strip Detectors (SSDs) used in EMPHATIC. As part of the data analysis process and in order to increase the accuracy of EMPHATIC’s simulations a representation of efficiency of each SSD is required. To achieve this a data-driven analysis was performed on EMPHATIC's collected data using the Root and Art frameworks. Visual and numerical representations of efficiency were determined. The average efficiency over all SSDs is 98.58\%, however this number deflated as it includes known bad channels.

Olson, V. [Illinois U., Urbana (main)]↗

Development of a Broad High-Energy Gamma-Ray Telescope using Silicon Strip Detectors

The research effort has led to the development and demonstration of technology to enable the design and construction of a next-generation high-energy gamma-ray telescope that operates in the pair-production regime (E greater than 10 MeV). In particular, the technology approach developed is based on silicon-strip detector technology. A complete instrument concept based on this technology for the pair-conversion tracker and the use of CsI(T1) crystals for the calorimeter is now the baseline instrument concept for the Gamma-ray Large Area Space Telescope (GLAST) mission. GLAST is NASA's proposed high-energy gamma-ray mission designed to operate in the energy range from 10 MeV to approximately 300 GeV. GLAST, with nearly 100 times the sensitivity of EGRET, operates through pair conversion of gamma-rays and measurement of the direction and energy of the resulting e (+) - e (-) shower. The baseline design, developed with support from NASA includes a charged particle anticoincidence shield, a tracker/converter made of thin sheets of high-Z material interspersed with Si strip detectors, a CsI calorimeter and a programmable data trigger and acquisition system. The telescope is assembled as an array of modules or towers. Each tower contains elements of the tracker, calorimeter, and anticoincidence system. As originally proposed, the telescope design had 49 modules. In the more optimized design that emerged at the end of the grant period the individual modules are larger and the total number in the GLAST array is 25. Also the calorimeter design was advanced substantially to the point that it has a self-contained imaging capability, albeit much cruder than the tracker.

Michelson, Peter F.↗

Quality concerns caused by quality control — deformation of silicon strip detector modules in thermal cycling tests

The ATLAS experiment at the Large Hadron Collider (LHC) is currently preparing to replace its present Inner Detector (ID) with the upgraded, all-silicon Inner Tracker (ITk) for its High-Luminosity upgrade (HL-LHC). The ITk will consist of a central pixel tracker and the outer strip tracker, consisting of about 19,000 strip detector modules. Each strip module is assembled from up to two sensors, and up to five flexes (depending on its geometry) in a series of gluing, wirebonding and quality control steps. During detector operation, modules will be cooled down to temperatures of about -35 °C (corresponding to the temperature of the support structures on which they will be mounted) after being initially assembled and stored at room temperature. In order to ensure compatibility with the detector's operating temperature range, modules are subjected to thermal cycling as part of their quality control process. Ten cycles between -35 °C and +40 °C are performed for each module, with full electrical characterisation tests at each high and low temperature point. As part of an investigation into the stress experienced by modules during cooling, it was observed that modules generally showed a change in module shape before and after thermal cycling. This paper presents a summary of the discovery and understanding of the observed changes, connecting them with excess module stress, as well as the resulting modifications to the module thermal cycling procedure.

47 OTHER INSTRUMENTATION↗

A Radiation Dosimeter Concept for the Lunar Surface Environment

A novel silicon detector configuration for radiation dose measurements in an environment where solar energetic particles are of most concern is described. The dosimeter would also measure the dose from galactic cosmic rays. In the lunar environment a large range in particle flux and ionization density must be measured and converted to dose equivalent. This could be accomplished with a thick (e.g. 2mm) silicon detector segmented into cubic volume elements "voxels" followed by a second, thin monolithic silicon detector. The electronics needed to implement this detector concept include analog signal processors (ASIC) and a field programmable gate array (FPGA) for data accumulation and conversion to linear energy transfer (LET) spectra and to dose-equivalent (Sievert). Currently available commercial ASIC's and FPGA's are suitable for implementing the analog and digital systems.

Adams, James H.↗