Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “servers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Detector Interface for Streaming, Control, and Open-source integration (DISCO) v1.0.0

This suite consists of a multi-package ecosystem featuring detector emulators, EPICS areaDetector drivers, and remote server frameworks designed for the Advanced Light Source (ALS). Engineered for high-bandwidth devices—including VFCCD, Timepix3, Timepix4, and related pixel detectors—the software simulates hardware, wraps vendor SDKs into remote-callable servers, and integrates with open-source control systems. Key Capabilities: Distributed SDK Architecture: Server packages wrap hardware-specific SDKs, allowing areaDetector drivers to execute remote framework calls. This isolates proprietary libraries from the EPICS IOC, enhancing stability and enabling distributed computing across beamline networks. Device Support: Custom drivers for VFCCD, the Timepix family, and similar sensors optimize the data path from hardware control to high-speed transport. Full-Stack Emulation: Sophisticated emulator packages allow end-to-end pipeline testing and software development without requiring physical hardware or beam time. Integrated Workflows: Supports high-bandwidth streaming for real-time analysis and robust, metadata-rich file-based workflows (e.g., HDF5/NeXus). By standardizing interfaces across heterogeneous hardware, this suite reduces technical debt. It provides the ALS with a scalable, open-source solution to manage massive data rates within a unified control environment.

Mahl, Johannes [Lawrence Berkeley National Laborat↗

Implementation of a Web Interface to Display Real-Time Statistics of a Dilution Refrigerator

The purpose of the project is to communicate with a Bluefors control unit and extract data. The Bluefors control unit is a piece of experimental equipment that measures various different data points in a dilution refrigerator and stores them. The goal was to access the control unit using the websockets library in Python. After accessing the control unit, the goal was to export the data to a web page in HTML/CSS. The tools that were used changed throughout the project. Python was used to communicate with the Bluefors unit via JSON requests and JSON objects, then the Python hosted its own websocket server to act as a proxy server to allow for the web page to access the data. This was done to bypass SSL verification. Then, the web page, which was created using JavaScript, React, Next.js, and NodeJS, accesses the proxy server to import the data from the dilution refrigerator and display the values in real time on the page.

Rasheed, Hammad↗

LEED: A Lightwave Energy-Efficient Datacenter

The Lightwave Energy-Efficient Datacenter (LEED) program is a disruptive “green-field” approach that provides a quantum leap in the energy efficiency of datacenters. LEED’s fundamental value proposition is that a novel and re-architected optical network—RotorNet— can deliver “more bandwidth per buck” as well as unique system-level attributes that significantly improve overall datacenter energy efficiency and performance. LEED has developed three system-level testbeds. The first testbed uses calibrated hardware and software power measurements to determine server energy efficiency as a function of network bandwidth and workload. These measurements have shown that increasing network communications bandwidth dramatically increases server energy efficiency providing a realistic path to the overall ENLITENED program goal of doubling the number of transactions per joule. The second testbed demonstrates key hardware: a prototype low-loss, high-port count optical “selector switch”. This switch was fabricated, racked, and tested. Measured switch characteristics include loss, bandwidth, crosstalk, switch time, system-level switch time (including the transceivers), and bit error rate. The third testbed demonstrates a fully working and manufactured pinwheel design which dramatically lowers the cost of design, while delivering high switch radix and low reconfiguration times. The LEED project has tied these three novel photonic switch prototypes together with production servers and software through the development of a novel FPGA-based NIC platform called Corundum. Corundum ensures that the packet-switched protocols supported by commodity operating systems and devices can interface with the Rotor switch design. The LEED group has used this combined hardware and software prototype to characterize applications running at a commercially relevant scale. The project has used a combination of enhanced optical modulation amplitude (OMA) modulators, broadband multiplexers and demultiplexers, avalanche photodiodes, and a novel burst-mode receivers to enable the insertion of LEED-developed optical switches without the need for expensive optical amplification. Our modeling has shown that measured LEED-developed device characteristics can achieve link characteristics of 2 pJ/bit including both transceivers and the Rotor switch. In summary, the LEED program has demonstrated a credible and practical path, through novel hardware and software, to realize the program objectives of ENLITENED. The net result will ensure that the United States maintains its strength in the crucial sector of Information Technology, which is vital to both our economic security and our national security.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Demonstration of a Novel Technology to Manage Electricity Demand in Grid-Independent Military Microgrids

This research was conducted by the National Renewable Energy Laboratory (NREL) in collaboration with the S&C Electric Inc. through funding provided by the ESTCP. The project demonstrates use of cybersecure Automated Demand Response (ADR) technology to effectively manage microgrid loads during grid-independent, also known as "islanded," operation. When military microgrids become isolated from the main electrical grid, they are required to balance electricity supply and demand locally. Given that local generation may be constrained, the prevailing strategy involves shedding all but the most critical loads by tripping smart circuit breakers, which then necessitate manual resetting. This approach is generally implemented at the building level, which means that the buildings with mission-critical activities are exempt from load management and remain fully powered, whereas those deemed non-critical can experience a complete loss of service. In this research we developed a method that allows building automation systems to selectively control their assets in response to load shedding request from a microgrid controller, avoiding total loss of service in contrast to the conventional control approach. A commercial OpenADR client server by GridFabric is used for communication between the microgrid controller and the building management system (BMS). The microgrid controller monitors both generation capacity and various assets within the microgrid and issues a demand reduction request when necessary. This request is communicated to the OpenADR server via Modbus. Upon receiving the request, the OpenADR server forwards it to the BMS utilizing the OpenADR protocol. The BMS is pre-configured with various levels of load reduction strategies based on the controllable assets available, allowing for a nuanced approach to demand reduction. Both lab and field tests were performed that considered load shedding needed to achieve closed transition into island mode and to accommodate changing loads and power source availability while islanded. A commercial microgrid controller was used for these tests with normal programming within the expected constraints of the system capabilities. That is, the solution did not require any specialized modification to the code base of the controller. Given the latency of the round-trip communication path between the microgrid controller and the various devices involved with the load shed processes, there are certain scenarios for which the demonstrated solution are appropriate and some which are not. The methods described in this report can be used for load shedding/restoration during transitions between islanded and grid-tied modes of operation, as well as accommodating normal variations in load and the need to remove a power source from operation for maintenance. These methods should not be used for scenarios that require load shedding within a second or two such as sudden and unanticipated significant load increases or loss of power sources through equipment faults.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Precursor Analysis Report: SQL Slammer Worm Infection of Davis-Besse Nuclear Power Plant 2003

The SQL Slammer Worm Infection of Davis-Besse Nuclear Power Plant 2003 Precursor Analysis Report leverages publicly available information about Davis-Besse’s 2003 cyber attack and catalogs anomalous observables for each technique employed in the attack. This analysis is based upon the methodology of the Cybersecurity for the Operational Technology Environment (CyOTE) program. On 25 January 2003, the SQL Slammer worm infected more than 90% of vulnerable hosts and crashed the internet in 10 to 15 minutes, making it one of the fastest spreading worms in history. SQL Slammer is a fileless, memory-resident worm that remotely exploits a stack-based buffer overflow vulnerability on local hosts to intensively scan and rapidly self-propagate across the internet. The worm infected approximately 300,000 unpatched hosts running Microsoft Structured Query Language (SQL) Server 2000 or Microsoft Desktop Engine (MSDE) 2000 with SQL Server Resolution Service. The SQL Slammer worm indirectly infected FirstEnergy’s Davis-Besse nuclear power plant by first infecting a consultant’s company network server and then propagating through an external misconfigured connection into Davis-Besse’s site network. The infection caused major network congestion, slow performance, data overloads, and the inability of local hosts to communicate with each other, which eventually caused a loss of availability and a loss of view when the Safety Parameter Display System (SPDS) and Plant Process Computer (PPC) crashed. At the time of the infection, the plant was already offline, the digital monitoring systems had redundant analog backups, and the plant control and safety functions were not affected, so there were no concerns of a safety breach. However, this incident resulted in many lessons learned and spawned important discussions about cybersecurity’s role in nuclear safety and electric power reliability regulation, policy, and guidance. Researchers and analysts identified 10 unique techniques utilized during the attack with a total of 640 observables using MITRE ATT&CK® for Industrial Control Systems. The CyOTE program assesses observables accompanying techniques used prior to the triggering event to identify opportunities to detect malicious activity. If observables accompanying the attack techniques are perceived and investigated prior to the triggering event, earlier comprehension of malicious activity can take place. Eight of the identified techniques used during Davis-Besse cyber attack were precursors to the triggering event. Analysis identified 596 observables associated with these precursor techniques, 428 of which were assessed to have an increased likelihood of being perceived in the 331 days preceding the triggering event. The response and comprehension time could have been reduced if the observables had been identified earlier. The information gathered in this report contributes to a library of observables tied to a repository of artifacts, data sources, and technique detection references for practitioners and developers to support the comprehension of indicators of attack. Asset owners and operators can use these products if they experience similar observables or to prepare for comparable scenarios.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

FedADMP: A Joint Anomaly Detection and Mobility Prediction Framework via Federated Learning

With the proliferation of mobile devices and smart cameras, detecting anomalies and predicting their mobility are critical for enhancing safety in ubiquitous computing systems. Due to data privacy regulations and limited communication bandwidth, it is infeasible to collect, transmit, and store all data from mobile devices at a central location. To overcome this challenge, we propose FedADMP, a federated learning based joint Anomaly Detection and Mobility Prediction framework. FedADMP adaptively splits the training process between the server and clients to reduce computation loads on clients. To protect the privacy of user data, clients in FedADMP upload only intermediate model parameters to the cloud server. We also develop a differential privacy method to prevent the cloud server and external attackers from inferring private information during the model upload procedure. Extensive experiments using real-world datasets show that FedADMP consistently outperforms existing methods.

97 MATHEMATICS AND COMPUTING↗

Software defined networking multiple operating system rotational environment

Systems, methods, and storage media for utilizing software defined networking for a multiple operating system rotational environment, executing on a computing device are disclosed. Some implementations may: receive a request from a user device; modify a packet of the request with a destination address and a port of a first server; forward the modified packet of the request to a controller server; receive a flow modification from the controller server based on the modified packet; and modify further received packets from the user device based on the received flow modification.

97 MATHEMATICS AND COMPUTING↗

Resolution system that provides access to remote data locally

A system and method that provides access to remote data locally by identifying and downloading linked content from a plurality of remote sources through a communication network; decomposing the downloaded content into local content elements by intercepting links between the content elements and mapping the intercepted links to redirected links that locate the same download content in a local cache or a local server proxy; identifying remote devices requesting access to the local cache or the local server proxy and the device's functionality through a tracking code stored on the remote devices and a probabilistic tracking; and providing access to the local cache or the local server proxy in response to authorizations associated with the identified devices and a user.

97 MATHEMATICS AND COMPUTING↗

Provisioning cooling elements for chillerless data centers

Systems and methods for cooling include one or more computing structures, a heat rejection system configured to cool coolant, and one or more heat exchangers configured to selectively transfer heat from coolant in the intra-structure cooling system to coolant in the heat rejection system. Each computing structure includes one or more cooled servers and an intra-structure cooling system configured to selectively provide coolant to the one or more cooled servers. A controller is configured to adjust cooling of the coolant in accordance with ambient temperature information, to decrease cooling of the coolant if the coolant temperature falls below a first coolant threshold temperature by disengaging one or more heat exchangers, and to turn on additional servers if the coolant temperature is below the first cool and threshold and all heat exchangers have been disengaged.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Accessing protected data by a high-performance computing cluster

A data protection system is provided that allows applications to access protected data in a way that restricts applications from outputting to unauthorized targets any unprotected data derived from the protected data and that ensures that the applications do not have access to a key that allows access to the unprotected data. The data protection system provides a policy server that may execute on a service node of a high performance computing system and a data encryption process that may execute on each compute node that is allocated to an application or batch job. The policy server maintains policies of entities specifying access control for protected data. The data encryption process generates a secure execution environment for an application process and interfaces with the policy server to retrieve keys for decrypting protected data in accordance with a policy, and it decrypts and provides the decrypted data to the application process.

Barnes, Peter↗

Methods and systems for detection of man-in-the-middle attacks for SCADA communication networks and applications of same

A system for detecting MITM for SCADA communication networks includes secure substation-substation communication links for providing secure and reliable paths to exchange OT data between substations for OT data consistency check; a SIB in each substation for sampling CT and PT measurements to calculate voltage magnitude and phase angle thereof; a S&C server in each substation coupled to the SIB for receiving the voltage magnitude and phase angle from the SIB and obtaining a packet carrying active power flow in transmission lines between two substations and a time stamp; an IDS server placed in a SCADA center for collecting the packet of each substation sent by the S&C server; analyzing the received packet from every adjacent substation; inspecting the payload of the received packet; and triggering an intrusion alarm to a SCADA operator when the power flow is not the same as the payload of the packets.

McCann, Roy A.↗

Systems, devices, and methods for authenticating millimeter wave devices

Systems, devices, and methods are described for millimeter wave device authentication. A system may include one or more access points. Each access point of the one or more access points is configured to extract, from one or more beam patterns generated via a client device, a beam feature associated with the client device. Each access point may also be configured to transmit the beam feature. The system may also include a server communicatively coupled to the one or more access points and including a database for storing known beam features. The server may be configured to receive the beam feature associated with the client device from at least one access point of the one or more access points. Also, the server may be configured to authenticate the client device in response to the received beam feature matching a known beam feature stored in the at least one database.

Bhuyan, Arupjyoti↗

Privacy-Preserving Control of Partitioned Energy Resources

Distributed energy resources are an increasingly important part of the electric grid. We examine the problem of partitioning a distributed energy resource among many users while providing privacy to them. In this model, clients can send requests to a server, the server can verify that the requests are valid and aggregate them, but it cannot see the actual values in the requests. Without privacy, each user is forced to reveal their daily schedule or energy use. Energy resources add a novel challenge that prior systems do not address: they require verifying limits on private power (a rate over time) and energy (a sum) values. Furthermore, the cryptographic mechanisms must run on embedded energy control systems. We describe Weft, a novel cryptographic system that verifies both power (rate) and energy (integral) constraints on private client values and aggregates them. The key insight behind the approach is to rely on additively homomorphic secret shares, which allows servers to compute sums from rates. We present 3 cryptographic proof systems with different system trade-off for embedded systems: bit-splitting proofs minimize memory use, sorting proofs minimize computation, and commitment proofs minimize network communication. Using bit-splitting proofs, it takes an IoT client using a CortexM microcontroller 4 minutes of compute time to privately control its share of an energy resource for a day at 20s granularity.

Laufer, Evan↗

BIPSPI+: Mining Type-Specific Datasets of Protein Complexes to Improve Protein Binding Site Prediction

Computational approaches for predicting protein-protein interfaces are extremely useful for understanding and modelling the quaternary structure of protein assemblies. In particular, partner-specific binding site prediction methods allow delineating the specific residues that compose the interface of protein complexes. In recent years, new machine learning and other algorithmic approaches have been proposed to solve this problem. However, little effort has been made in finding better training datasets to improve the performance of these methods. With the aim of vindicating the importance of the training set compilation procedure, in this work we present BIPSPI+, a new version of our original server trained on carefully curated datasets that outperforms our original predictor. We show how prediction performance can be improved by selecting specific datasets that better describe particular types of protein interactions and interfaces (e.g. homo/hetero). In addition, our upgraded web server offers a new set of functionalities such as the sequence-structure prediction mode, hetero- or homo-complex specialization and the guided docking tool that allows to compute 3D quaternary structure poses using the predicted interfaces. BIPSPI+ is freely available at https://bipspi.cnb.csic.es.

59 BASIC BIOLOGICAL SCIENCES↗

OASIS: Offsetting Active Reconstruction Attacks in Federated Learning

Federated Learning (FL) has garnered significant attention for its potential to protect user privacy while enhancing model training efficiency. For that reason, FL has found its use in various domains, from health care to industrial engineering, especially where data cannot be easily exchanged due to sensitive information or privacy laws. However, recent research has demonstrated that FL protocols can be easily compromised by active reconstruction attacks executed by dishonest servers. These attacks involve the malicious modification of global model parameters, allowing the server to obtain a verbatim copy of users' private data by inverting their gradient updates. Tackling this class of attack remains a crucial challenge due to the strong threat model. In this paper, we propose a defense mechanism, namely OASIS, based on image augmentation that effectively counteracts active reconstruction attacks while preserving model performance. We first uncover the core principle of gradient inversion that enables these attacks and theoretically identify the main conditions by which the defense can be robust regardless of the attack strategies. We then construct our defense with image augmentation showing that it can undermine the attack principle. Comprehensive evaluations demonstrate the efficacy of the defense mechanism highlighting its feasibility as a solution.

deep neural networks↗

Securing Federated Learning Against Active Reconstruction Attacks

Federated Learning (FL) has amassed notable attention for its ability to preserve user privacy while emphasizing the retainment of model training efficiency. Due to this potential, FL has been integrated in many domains, such as healthcare, finance, law, and industrial engineering, where data cannot be easily exchanged due to sensitive information and strict privacy laws. However, current research has indicated that FL protocols are easily compromised by active data reconstruction attacks employed by actively dishonest servers. The malicious modification of global model parameters allows an actively dishonest server to obtain a direct copy of users’ private data via gradient inversion. Here, this class of attacks is highly underexplored and continues to be a major challenge due to the intense threat model. In this paper, we propose OASIS as a scalable and modality-agnostic defense based on data augmentation that counteracts active data reconstruction attacks while preserving model performance. To generalize our defense, we uncover the intuition behind gradient inversion that enables these attacks and theoretically establish the conditions by which the defense can be considered robust regardless of attack design. From this, we formulate our defense with data augmentation that illustrates its ability to undermine the attack principle. We evaluate OASIS on five real-world datasets–two image-based (ImageNet and CIFAR100) and three text-based (Wikitext, Stack Overflow, and Shakespeare)–which span diverse uses cases such as vision tasks and language modeling. Comprehensive evaluations on these datasets exhibit the efficacy of OASIS and highlight its feasibility as a solution.

97 MATHEMATICS AND COMPUTING↗

Exploring the benefits of using co-packaged optics in data center and AI supercomputer networks: a simulation-based analysis [Invited]

We investigate the advantages of using co-packaged optics in next-generation data center and AI supercomputer networks. The increased escape bandwidth offered by co-packaged optics provides multiple possibilities for building 50T switches and beyond, expanding the opportunities in both the data center and supercomputing domains. Furthermore, this provides network architects with the opportunity to expand their design space and develop simplified networks with enhanced network locality properties. Co-packaging at the switch and server points enables networks with double capacity while reducing the switch count by 64% compared to state-of-the-art systems. We evaluate these concepts through discrete-event simulations using all-to-all and all-reduce traffic patterns that simulate collective communications commonly found in network-bound applications. Initially, we investigate the all-to-all overhead involved in distributing the virtual machines of the applications across multiple leaf switches and compare it to the scenario in which all VMs are placed under a single switch. Subsequently, we evaluate the performance of an AI supercomputing cluster by simulating both patterns for different message sizes, while also varying the number of participating nodes. The results suggest that networks with improved locality properties become increasingly important as the network stack operates at higher speeds; for a stack latency of 1.25 µs, placing the applications under multiple switches can result in up to 68% higher completion times than placing them under a single switch. For AI supercomputers, significant improvements are observed in the mean server throughput, reaching more than 90% for configurations involving 256 nodes and message sizes of at least 128 KiB.

99 GENERAL AND MISCELLANEOUS↗

MOOSE–Workbench Integration and MOOSE Meshing Capability Enhancements to Facilitate Inputs and Outputs for Multiphysics Modeling

The Multiphysics Object-Oriented Simulation Environment (MOOSE) is an open-source framework that supports many of the US Department of Energy’s (DOE’s) Nuclear Energy Advanced Modeling and Simulation (NEAMS) technical areas (TA). These TAs develop and use NEAMS physics and coupling modules in multiple ways to enable the research and development of complex physics models. In addition to the MOOSE framework, the NEAMS Workbench user interface provides a common analysis environment with user-interaction accelerators that streamline the tasks of model creation, review, execution, and output inspection. In FY 2024, objectives were realized in the MOOSE framework application development support and user-oriented improvements. Application development improvements support both developers and users with an expanded Reactor Module and Mesh System, stateful material property support for mortar contact, and customizable convergence criteria. Additionally, new user-oriented features were implemented in the MOOSE framework language server, including autocompletion snippets, definition from source and find reference navigations, and syntax overrides. Lastly, improvements were made to the input interpreter necessary to support the MOOSE language server and the NEAMS Workbench so that they can interact with syntactically incomplete user inputs. These improvements and more were intended to address stakeholder feedback and improve developer and user ability to conduct advanced nuclear energy modeling and simulation in support of DOE and industry needs.

97 - MATHEMATICS AND COMPUTING↗