Coarsening in Solid-Liquid Mixtures Studied on the Space Shuttle

Ostwald ripening, or coarsening, is a process in which large particles in a two-phase mixture grow at the expense of small particles. It is a ubiquitous natural phenomena occurring in the late stages of virtually all phase separation processes. In addition, a large number of commercially important alloys undergo coarsening because they are composed of particles embedded in a matrix. Many of them, such as high-temperature superalloys used for turbine blade materials and low-temperature aluminum alloys, coarsen in the solid state. In addition, many alloys, such as the tungsten-heavy metal systems, coarsen in the solid-liquid state during liquid phase sintering. Numerous theories have been proposed that predict the rate at which the coarsening process occurs and the shape of the particle size distribution. Unfortunately, these theories have never been tested using a system that satisfies all the assumptions of the theory. In an effort to test these theories, NASA studied the coarsening process in a solid-liquid mixture composed of solid tin particles in a liquid lead-tin matrix. On Earth, the solid tin particles float to the surface of the sample, like ice in water. In contrast, in a microgravity environment this does not occur. The microstructures in the ground- and space-processed samples (see the photos) show clearly the effects of gravity on the coarsening process. The STS-83-processed sample (right image) shows nearly spherical uniformly dispersed solid tin particles. In contrast, the identically processed, ground-based sample (left image) shows significant density-driven, nonspherical particles, and because of the higher effective solid volume fraction, a larger particle size after the same coarsening time. The "Coarsening in Solid-Liquid Mixtures" (CSLM) experiment was conducted in the Middeck Glovebox facility (MGBX) flown aboard the shuttle in the Microgravity Science Laboratory (MSL-1/1R) on STS-83/94. The primary objective of CSLM is to measure the temporal evolution of the solid particles during coarsening.

Caruso, John J.↗

New Diagnostic, Launch and Model Control Techniques in the NASA Ames HFFAF Ballistic Range

This report presents new diagnostic, launch and model control techniques used in the NASA Ames HFFAF ballistic range. High speed movies were used to view the sabot separation process and the passage of the model through the model splap paper. Cavities in the rear of the sabot, to catch the muzzle blast of the gun, were used to control sabot finger separation angles and distances. Inserts were installed in the powder chamber to greatly reduce the ullage volume (empty space) in the chamber. This resulted in much more complete and repeatable combustion of the powder and hence, in much more repeatable muzzle velocities. Sheets of paper or cardstock, impacting one half of the model, were used to control the amplitudes of the model pitch oscillations.

Bogdanoff, David W.↗

Evaluation of the Separability of Monodisperse Polystyrene Latex Microspheres in a Continuous Flow Electrophoresis System

The continuous flow electrophoresis system makes electrophoresis possible in a free flowing film of aqueous electrolyte medium. The sample is introduced at one end of the chamber and is subjected to a lateral dc field. This process separates the sample into fractions since each component has a distinctive electrophoric mobility. Evaluations were made of sample conductivity and buffer conductivity as they affect sample band spread and separation using the Continuous Particle Electrophoresis (CPE) system. Samples were prepared from mixtures of 5 percent and 1 percent polystyrene latex (PSL) microspheres which were .4, .56 and .7 microns in diameter. These were prepared in electrolyte media 1x and 3x the conductivity of the curtain buffer, approximately 150 and 450 micro mhos/cm. Samples with matched conductivities produced greater resolution and less band spread than those with 3x the conductivity of the curtain buffer.

Williams, G., Jr.↗

Sample Acquisition and Analytical Chemistry Challenges to Verifying Compliance to Aviators Breathing Oxygen (ABO) Purity Specification

NASA has been developing and testing two different types of oxygen separation systems. One type of oxygen separation system uses pressure swing technology, the other type uses a solid electrolyte electrochemical oxygen separation cell. Both development systems have been subjected to long term testing, and performance testing under a variety of environmental and operational conditions. Testing these two systems revealed that measuring the product purity of oxygen, and determining if an oxygen separation device meets Aviator's Breathing Oxygen (ABO) specifications is a subtle and sometimes difficult analytical chemistry job. Verifying product purity of cryogenically produced oxygen presents a different set of analytical chemistry challenges. This presentation will describe some of the sample acquisition and analytical chemistry challenges presented by verifying oxygen produced by an oxygen separator - and verifying oxygen produced by cryogenic separation processes. The primary contaminant that causes gas samples to fail to meet ABO requirements is water. The maximum amount of water vapor allowed is 7 ppmv. The principal challenge of verifying oxygen produced by an oxygen separator is that it is produced relatively slowly, and at comparatively low temperatures. A short term failure that occurs for just a few minutes in the course of a 1 week run could cause an entire tank to be rejected. Continuous monitoring of oxygen purity and water vapor could identify problems as soon as they occur. Long term oxygen separator tests were instrumented with an oxygen analyzer and with an hygrometer: a GE Moisture Monitor Series 35. This hygrometer uses an aluminum oxide sensor. The user's manual does not report this, but long term exposure to pure oxygen causes the aluminum oxide sensor head to bias dry. Oxygen product that exceeded the 7 ppm specification was improperly accepted, because the sensor had biased. The bias is permanent - exposure to air does not cause the sensor to return to its original response - but the bias can be accounted for by recalibrating the sensor. After this issue was found, continuous measurements of water vapor in the oxygen product were made using an FTIR. The FTIR cell is relatively large, so response time is slow - but moisture measurements were repeatable and accurate. Verifying ABO compliance for oxygen produced by commercial cryogenic processes has a different set of sample acquisition and analytical chemistry challenges. Customers want analytical chemists to conserve as much as possible. Hygrometers are not exposed to hours of continuous flow of oxygen, so they don't bias, but small amounts of contamination in valves can cause a "fail". K bottles are periodically cleaned and recertified - after cleaning residual moisture can cause a "fail". Operators let bottle pressure drop to room pressure, introduce outside air into the bottle, and the subsequent fill will "fail". Outside storage of K‐bottles has allowed enough in‐leakage, so contents will "fail".

Graf, John↗

Chemical aspects of agglutinate formation - Relationships between agglutinate composition and the composition of the bulk soil

Attention is centered on the nature and intensity of geochemical fractionation accompanying agglutination of several size fractions of the immature Apollo-16 soil sample 67460, from North Ray Crater. The soil features coarse mean grain size about 150 microns, low (20 wt.%) magnetic agglutinate content, and a bimodal grain size distribution. The magnetic fraction included both agglutinates and magnetic non-agglutinates (glass-free microbreccias with 30-60 micron native FeNi grains hosted in a matrix of pyroxene, ilmenite, and olivine). The separation process residue contained nonmagnetic agglutinates with compositions near pure plagioclase. The magnetic agglutinate fraction appears selectively enriched in ferromagnesian elements to the partial exclusion of plagioclase elements. Agglutinate glass chemistry based solely on magnetic separation is deprecated on the basis of the results.

Via, W. N.↗

New Techniques to Evaluate the Incendiary Behavior of Insulators

New techniques for evaluating the incendiary behavior of insulators is presented. The onset of incendive brush discharges in air is evaluated using standard spark probe techniques for the case simulating approaches of an electrically grounded sphere to a charged insulator in the presence of a flammable atmosphere. However, this standard technique is unsuitable for the case of brush discharges that may occur during the charging-separation process for two insulator materials. We present experimental techniques to evaluate this hazard in the presence of a flammable atmosphere which is ideally suited to measure the incendiary nature of micro-discharges upon separation, a measurement never before performed. Other measurement techniques unique to this study include; surface potential measurements of insulators before, during and after contact and separation, as well as methods to verify fieldmeter calibrations using a charge insulator surface opposed to standard high voltage plates. Key words: Kapton polyimide film, incendiary discharges, brush discharges, contact and frictional electrification, ignition hazards, insulators, contact angle, surface potential measurements.

Buhler, Charles↗

Parallel processing spacecraft communication system

An uplink controlling assembly speeds data processing using a special parallel codeblock technique. A correct start sequence initiates processing of a frame. Two possible start sequences can be used; and the one which is used determines whether data polarity is inverted or non-inverted. Processing continues until uncorrectable errors are found. The frame ends by intentionally sending a block with an uncorrectable error. Each of the codeblocks in the frame has a channel ID. Each channel ID can be separately processed in parallel. This obviates the problem of waiting for error correction processing. If that channel number is zero, however, it indicates that the frame of data represents a critical command only. That data is handled in a special way, independent of the software. Otherwise, the processed data further handled using special double buffering techniques to avoid problems from overrun. When overrun does occur, the system takes action to lose only the oldest data.

Bolotin, Gary S.↗

Removal of histological sections from glass for electron microscopy - Use of Quetol 651 resin and heat

A number of approaches have been used to separate stained conventional histological sections from glass slides in preparation for a study with the electron microscope. However, in each reported case some problems were encountered with respect to the separation process. The present investigation is concerned with the use of the epoxy resin Quetol 651 as an embedding medium for this procedure, taking into account the simple application of heat (62-64 C) for performing the separation step. After the tissue has been removed from the glass by the considered technique, it is thin sectioned, and stained with uranyl acetate-lead citrate.

Kraft, L. M.↗

A Diagnostic System for Studying Energy Partitioning and Assessing the Response of the Ionosphere during HAARP Modification Experiments

This research program focused on the construction of several key radio wave diagnostics in support of the HF Active Auroral Ionospheric Research Program (HAARP). Project activities led to the design, development, and fabrication of a variety of hardware units and to the development of several menu-driven software packages for data acquisition and analysis. The principal instrumentation includes an HF (28 MHz) radar system, a VHF (50 MHz) radar system, and a high-speed radar processor consisting of three separable processing units. The processor system supports the HF and VHF radars and is capable of acquiring very detailed data with large incoherent scatter radars. In addition, a tunable HF receiver system having high dynamic range was developed primarily for measurements of stimulated electromagnetic emissions (SEE). A separate processor unit was constructed for the SEE receiver. Finally, a large amount of support instrumentation was developed to accommodate complex field experiments. Overall, the HAARP diagnostics are powerful tools for studying diverse ionospheric modification phenomena. They are also flexible enough to support a host of other missions beyond the scope of HAARP. Many new research programs have been initiated by applying the HAARP diagnostics to studies of natural atmospheric processes.

Djuth, Frank T.↗

CO2 Removal and Atmosphere Revitalization Systems for Next Generation Space Flight

Removal of metabolic CO2 from breathing air is a vital process for life support in all crewed space missions. A CO2 removal processor called the Low Power CO2 Removal (LPCOR) system is being developed in the Bioengineering Branch at NASA Ames Research Center. LPCOR utilizes advanced adsorption and membrane gas separation processes to achieve substantial power and mass reduction when compared to the state-of-the-art carbon dioxide removal assembly (CORA) of the US segment of the International Space Station (ISS). LPCOR is an attractive alternative for use in commercial spacecraft for short-duration missions and can easily be adapted for closed-loop life support applications. NASA envisions a next-generation closed-loop atmosphere revitalization system that integrates advanced CO2 removal, O2 recovery, and trace contaminant control processes to improve overall system efficiency. LPCOR will serve as the front end to such a system. LPCOR is a reliable air revitalization technology that can serve both the near-term and long-term human space flight needs of NASA and its commercial partners.

Luna, Bernadette↗

A Study of Undercooling Behavior Of Immiscible Metal Alloys in the Absence of Crucible-Induced Nucleation

The purpose of this study is to investigate the question: Would eliminating the crucible eliminate the wall-induced nucleation of one of the liquid phases in an immiscible alloy and result in undercooling of the liquid into the metastable region thereby producing significant differences in the separation process and the microstructure upon solidification. Another primary objective of this research is to study systems with a metastable miscibility gap and to directly determine the metastable liquid miscibility gap by undercooling experiments. Nucleation and growth of droplets in these undercooled metallic liquid-liquid mixtures is also being studied. Results of this investigation indicate that containerless processing of immiscibles may not promote the undercooling of the single-phase liquid into the metastable region. Although no recalescence event was observed for this liquid-liquid transition, undercooling did occur across the miscibility gap for the solidification of the Ti phase that eventually separated.

Robinson, Michael B.↗

DYNACLIPS (DYNAmic CLIPS): A dynamic knowledge exchange tool for intelligent agents

In a dynamic environment, intelligent agents must be responsive to unanticipated conditions. When such conditions occur, an intelligent agent may have to stop a previously planned and scheduled course of actions and replan, reschedule, start new activities and initiate a new problem solving process to successfully respond to the new conditions. Problems occur when an intelligent agent does not have enough knowledge to properly respond to the new situation. DYNACLIPS is an implementation of a framework for dynamic knowledge exchange among intelligent agents. Each intelligent agent is a CLIPS shell and runs a separate process under SunOS operating system. Intelligent agents can exchange facts, rules, and CLIPS commands at run time. Knowledge exchange among intelligent agents at run times does not effect execution of either sender and receiver intelligent agent. Intelligent agents can keep the knowledge temporarily or permanently. In other words, knowledge exchange among intelligent agents would allow for a form of learning to be accomplished.

Cengeloglu, Yilmaz↗

Geodynamics branch data base for main magnetic field analysis

The data sets used in geomagnetic field modeling at GSFC are described. Data are measured and obtained from a variety of information and sources. For clarity, data sets from different sources are categorized and processed separately. The data base is composed of magnetic observatory data, surface data, high quality aeromagnetic, high quality total intensity marine data, satellite data, and repeat data. These individual data categories are described in detail in a series of notebooks in the Geodynamics Branch, GSFC. This catalog reviews the original data sets, the processing history, and the final data sets available for each individual category of the data base and is to be used as a reference manual for the notebooks. Each data type used in geomagnetic field modeling has varying levels of complexity requiring specialized processing routines for satellite and observatory data and two general routines for processing aeromagnetic, marine, land survey, and repeat data.

Langel, Robert A.↗

Metals processing

The metals processing effort is directed towards improvement of performance and usefulness of materials through modification and control of shape and internal structure. Interaction of reactive gases, introduced into a plasma arc, with iron alloys were analyzed. The technology of magnesium production was assessed. The study of fast fluidized bed reactors is continued. Aspects of separation processes are being investigated. The development of high field superconducting composites for use in large magnetic fusion devices is also discussed. Processing, structure, and property relationships of superconducting materials and the substitution of precious metals in standard electrical contact and connector applications are tested. The influence of processing procedures on the structure of zircaloy and nickel base alloys with a goal of improving mechanical properties and performance is investigated. Investigation of the potential of metal insulator semiconductor junctions as photovoltaic devices is reported.

Source record↗

Fractography of the high temperature hydrogen attack of a medium carbon steel

Microscopic fracture processes were studied which are associated with hydrogen attack of a medium carbon steel in a well-controlled, high-temperature, high-purity hydrogen environment. Exposure to a hydrogen pressure and temperature of 3.5 MN/m2 and 575 C was found to degrade room temperature tensile properties with increasing exposure time. After 408 hr, yield and ultimate strengths were reduced by more than 40 percent and elongation was reduced to less than 2 percent. Initial fissure formation was found to be associated with manganese rich particles, most probably manganese oxide, aligned in the microstructure during the rolling operation. Fissure growth was found to be associated with a reduction in carbide content of the microstructure and was inhibited by the depletion of carbon. The interior surfaces of sectioned fissures or bubbles exhibit both primary and secondary cracking by intergranular separation. The grain surfaces were rough and rounded, suggesting a diffusion-associated separation process. Specimens that failed at room temperature after exposure to hydrogen were found to exhibit mixed mode fracture having varying amounts of intergranular separation, dimple formation, and cleavage, depending on exposure time.

Melson, H. G.↗

Holographic microscopy studies of emulsions

A holographic microscopy system that records and observes the dynamic properties of separation of dispersed immiscible fluids is described. The holographic construction system and reconstruction system that were used to obtain particle size and distribution information from the holograms are discussed. The holographic microscopy system is used to observed the phase separating processes in immiscible fluids that were isothermally cooled into the two phase region. Nucleation, growth rates, coalescence, and particle motion are successfully demonstrated with this system. Thus a holographic particle sizing system with a resolution of 2 micrometers and a field of view of 100 cu cm was developed that provides the capability of testing the theories of separating immiscible fluids for particle number densities in the range of 10 to 10 to the 7th power particles.

Witherow, W. K.↗

On-line removal of volatile fatty acids from CELSS anaerobic bioreactor via nanofiltration

The CELSS (controlled ecological life support system) resource recovery system, which is a waste processing system, uses aerobic and anaerobic bioreactors to recover plants nutrients and secondary foods from the inedible biomass. The anaerobic degradation of the inedible biomass by means of culture of rumen bacteria,generates organic compounds such as volatile fatty acids (acetic, propionic, butyric, VFA) and ammonia. The presence of VFA in the bioreactor medium at fairly low concentrations decreases the microbial population's metabolic reactions due to end-product inhibition. Technologies to remove VFA continuously from the bioreactor are of high interest. Several candidate technologies were analyzed, such as organic solvent liquid-liquid extraction, adsorption and/or ion exchange, dialysis, electrodialysis, and pressure driven membrane separation processes. The proposed technique for the on-line removal of VFA from the anaerobic bioreactor was a nanofiltration membrane recycle bioreactor. In order to establish the nanofiltration process performance variables before coupling it to the bioreactor, a series of experiments were carried out using a 10,000 MWCO tubular ceramic membrane module. The variables studied were the bioreactor slurry permeation characteristics, such as, the permeate flux, VFA and the nutrient removal rates as a function of applied transmembrane pressure, fluid recirculation velocity, suspended matter concentration, and process operating time. Results indicate that the permeate flux, VFA and nutrients removal rates are directly proportional to the fluid recirculation velocity in the range between 0.6 to 1.0 m/s, applied pressure when these are low than 1.5 bar, and inversely proportional to the total suspended solids concentration in the range between 23,466 to 34,880. At applied pressure higher than 1.5 bar the flux is not more linearly dependent due to concentration polarization and fouling effects over the membrange surface. It was also found that the permeate flux declines rapidly during the first 5 to 8 hours, and then levels off with a diminishing rate of flux decay.

Colon, Guillermo↗

Modeling Evolvable Water Recovery Systems for Short and Long-Duration Missions in Partial Gravity

Water recovery technologies on the International Space Station (ISS) are designed and optimized for microgravity environments, thus creating a need for innovative systems optimized for mission operations in the presence of gravity. Alternative water recovery technologies under research by the Life Support Systems division were compiled into a series of Partial Gravity Water Recovery System (PGWRS) architectures. Individual unit processes were modeled via fundamental physical-chemical process equations to simulate their method of treatment, including chemical or biological oxidation, flash evaporation, filtration, or a combination of adsorption and ion exchange processes. Dimension and sizing data were then utilized to scale each architecture. Modeling was completed on an assortment of architectures assuming three scenarios in which treatment methods could take advantage of partial gravity: a short-duration mission with a temporary surface habitat, a longer duration mission with a more permanent habitat, and a long duration mission without resupply. Total system mass was estimated to quantitatively compare architectures within scenarios, but qualitative observations were also made regarding system robustness, flexibility, and capacity to meet more stringent demands. Technologies that traded most favorably between the scenarios were those that included a pre-oxidation stage to minimize mass loading to downstream absorption and ion exchange beds, exploited gravity in liquid-vapor separation processes, and reconstituted wastewater components into recyclable material streams.

Avery Carlson↗