Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sensor enabled coatings”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

NASA Tech Briefs, February 2014

Topics include: JWST Integrated Simulation and Test (JIST) Core; Software for Non-Contact Measurement of an Individual's Heart Rate Using a Common Camera; Rapid Infrared Pixel Grating Response Testbed; Temperature Measurement and Stabilization in a Birefringent Whispering Gallery Resonator; JWST IV and V Simulation and Test (JIST) Solid State Recorder (SSR) Simulator; Development of a Precision Thermal Doubler for Deep Space; Improving Friction Stir Welds Using Laser Peening; Methodology of Evaluating Margins of Safety in Critical Brazed Joints; Interactive Inventory Monitoring; Sensor for Spatial Detection of Single-Event Effects in Semiconductor-Based Electronics; Reworked CCGA-624 Interconnect Package Reliability for Extreme Thermal Environments; Current-Controlled Output Driver for Directly Coupled Loads; Bulk Metallic Glasses and Matrix Composites as Spacecraft Shielding; Touch Temperature Coating for Electrical Equipment on Spacecraft; Li-Ion Electrolytes Containing Flame-Retardant Additives; Autonomous Robotic Manipulation (ARM); CARVE Log; Platform Perspective Toolkit; Convex Hull-Based Plume and Anomaly Detection; Pre-Filtration of GOSAT Data Using Only Level 1 Data and an Intelligent Filter to Remove Low Clouds; Affordability Comparison Tool - ACT; "Ascent - Commemorating Shuttle" for iPad; Cassini Mission App; Light-Weight Workflow Engine: A Server for Executing Generic Workflows; Model for System Engineering of the CheMin Instrument; Timeline Central Concepts; Parallel Particle Filter Toolkit; Particle Filter Simulation and Analysis Enabling Non-Traditional Navigation; Quasi-Terminator Orbits for Mapping Small Primitive Bodies; The Subgrid-Scale Scalar Variance Under Supercritical Pressure Conditions; Sliding Gait for ATHLETE Mobility; and Automated Generation of Adaptive Filter Using a Genetic Algorithm and Cyclic Rule Reduction.

Source record↗

Multifunctional fiber-reinforced composites for passive sensing and energy harvesting with enhanced mechanical performance

Fiber-reinforced polymer composites (FRPCs) are valid alternatives to metals, especially in the aerospace industry, for their superior strength-to-weight ratio. FRPCs are generally manufactured by stacking layers of fibers and infusing them with epoxy-based adhesives to result in laminates. Such layer-by-layer structure often ensues a poor interlaminar property of the composites. Additionally, FRPCs can sustain complex damage modes because of their inherent anisotropic characteristics. For example, delamination can occur due to low-velocity impact at a subsurface level, which can result in premature catastrophic failures if undetected. Thus, structural monitoring is crucial to identify such damage. Point-based sensors (e.g., strain gauges, accelerometers, among many) can be embedded in the FRPCs for structural monitoring. However, their electrical power demand often embroils their usage. Therefore, the main objective of this research is to design and implement multifunctional composites that can simultaneously perform passive sensing and energy harvesting while exhibiting better mechanical performance. Previous research efforts have demonstrated that a continuous feed-through deposition of functional materials on fiber surfaces simultaneously enhanced the mechanical and sensing properties of the FRPCs. This study explores a similar approach to encode passive sensing and energy harvesting properties in the FRPCs by integrating ferroelectric microparticles on the fiber surfaces. Upon ensuring their superior interlaminar shear strength, sensing and energy harvesting properties were characterized through experimental studies. The outcome is a multifunctional composite fabricated by coating the fibers with functional microparticles through a high throughput, scalable, and low-cost approach that enables passive sensing, energy harvesting, and improved mechanical performance.

Gupta, Sumit↗

Additive manufacturing enabled hot-wire apparatus with suppressed edge effect error

This invention describes a method of structuring a metal or metal coated wire in a manner such that it provides enhanced accuracy when used in a hot-wire apparatus for transient thermal conductivity measurements for low-density materials. This is accomplished by using a diameter varying structure with two ends of the wire of sufficiently small diameter that the edge-effect induced error can be reduced by generating a more uniform temperature profile along the wire, whereas in conventional apparatus the temperatures always drop at the ends of a finite wire due to its ends that are being cooled by the wire-supports.

36 MATERIALS SCIENCE↗

An Overview of SHERLOC Raman and Fluorescence Spectroscopy Results Obtained During Perseverance’s Green Zone Campaign at Jezero Crater, Mars

The Perseverance rover landed in Jezero crater, Mars, in February 2021. The field site was chosen because orbiter data provided evidence that the crater hosted an ancient (>2.7 Ga) fluvio-lacustrine environment. The Octavia E. Butler landing site is located ~1.9 km east of the erosional remnant of the Jezero river delta. Scanning Habitable Environments with Raman and Luminescence for Organics and Chemicals (SHERLOC) is an arm-mounted instrument that combines fluorescence and Raman spectroscopy with microscopic imaging to analyze geological materials in order to better understand the history of the environments recorded in the rocks within Jezero crater and to search for potential biosignatures. SHERLOC has two microscopic cameras, the Autofocus and Context Imager (ACI) and the Wide-Angle Topographic Sensor for Operations and eNgineering, (WATSON). These subsystems obtain high spatial resolution (10.1–100 µm/pixel) images to identify grain-scale structure and texture. SHERLOC spectroscopy enables high-sensitivity detection, characterization, and spatially-resolved correlation of trace organic materials. SHERLOC’s 248.6 nm deep UV laser generates a 100 µm-diameter spot. Photons generated by Raman scattering and fluorescence emission are collected and the spectra are downlinked to Earth for analysis. Knowledge of where the laser is pointed allows for mineral and compositional maps to be generated and overlain in ACI and WATSON images. Early spectroscopy observations focused on natural rock surfaces at targets named Nataani (sol 83), Bi_la_sana (sol 98) and Foux (sol 141). These surfaces included patches of aeolian dust that had settled upon the rocks. Perseverance’s abrasion tool is expected to become available in August 2021; it will grind to depths of 14 mm to remove dust and penetrate coatings and weathering rinds. This presentation will summarize major results from analysis of the rocks examined by SHERLOC during Perseverance’s first science and sample coring campaign (Green Zone Campaign).

Luther W Beegle↗

Knittable and Washable Multifunctional MXene-Coated Cellulose Yarns

Textile-based electronics enable the next generation of wearable devices, which have the potential to transform the architecture of consumer electronics. Highly conductive yarns that can be manufactured using industrial-scale processing and be washed like everyday yarns are needed to fulfill the promise and rapid growth of the smart textile industry. By coating cellulose yarns with Ti 3 C 2 T x MXene, highly conductive and electroactive yarns are produced, which can be knitted into textiles using an industrial knitting machine. It is shown that yarns with MXene loading of ≈77 wt% (≈2.2 mg cm -1 ) have conductivity of up to 440 S cm -1 . After washing for 45 cycles at temperatures ranging from 30 to 80 °C, MXene-coated cotton yarns exhibit a minimal increase in resistance while maintaining constant MXene loading. The MXene-coated cotton yarn electrode offers a specific capacitance of 759.5 mF cm -1 at 2 mV s -1 . Additionally, a fully knitted textile-based capacitive pressure sensor is also prepared, which offers high sensitivity (gauge factor of ≈6.02), wide sensing range of up to ≈20% compression, and excellent cycling stability (2000 cycles at ≈14% compression strain). This work provides new and practical insights toward the development of platform technology that can integrate MXene in cellulose-based yarns for textile-based devices.

36 MATERIALS SCIENCE↗

Electrochemical Detection of Oxycodone and Its Main Metabolites with Nafion-Coated Single-Walled Carbon Nanotube Electrodes

Oxycodone is a strong opioid frequently used as an analgesic. Although proven efficacious in the management of moderate to severe acute pain and cancer pain, use of oxycodone imposes a risk of adverse effects such as addiction, overdose, and death. Fast and accurate determination of oxycodone blood concentration would enable personalized dosing and monitoring of the analgesic as well as quick diagnostics of possible overdose in emergency care. However, in addition to the parent drug, several metabolites are always present in the blood after a dose of oxycodone, and to date, there is no electrochemical data available on any of these metabolites. In this paper, a single-walled carbon nanotube (SWCNT) electrode and a Nafion-coated SWCNT electrode were used, for the first time, to study the electrochemical behavior of oxycodone and its two main metabolites, noroxycodone and oxymorphone. Both electrode types could selectively detect oxycodone in the presence of noroxycodone and oxymorphone. However, we have previously shown that addition of a Nafion coating on top of the SWCNT electrode is essential for direct measurements in complex biological matrices. Therefore, in this work, the Nafion/SWCNT electrode was further characterized and used for measuring clinically relevant concentrations of oxycodone in buffer solution. The limit of detection for oxycodone with the Nafion/SWCNT sensor was 85 nM, and the linear range was 0.5–10 μM in buffer solution. Furthermore, this study shows that the fabricated Nafion/SWCNT sensor has potential to be applied in clinical concentration measurements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Longevity evaluation of SiC based alpha voltaic batteries with surface alpha sources

The alpha emitting actinide 241 Am is electrodeposited on the surface of the Pt electrode of in-house fabricated SiC Schottky diodes. With 17 nCi 241 Am directly coated on the top of a device, the 2-pi geometry yields a high energy (5.486 MeV) and a long-term irradiation accumulating to a high fluence (1.6 × 10 9 alpha particles’ infusion/month). The forward, reverse I/V, and dark current, are periodically measured to monitor key characteristics of device durability for any sign of degradation over time. The direct deposition of actinides on the surface of the device also enables the evaluation of radiation damage through alpha particles’ energy spectroscopic performance, which shows a clear spectrum degradation that can be reversed by optical excitation of the device prior to spectrum acquisition. As an analytical aide, the device performance is also simulated by Allpix 2 . Lastly, this study provides an insight into the durability of 4H-SiC as an energy converter option for alpha-voltaic batteries and the survivability in the other harsh environment found in nuclear fuel cycle, high energy physics, fission, fusion, and space exploration where rad-hard sensors are required.

Americium↗

Actuated Hybrid Mirror Telescope

The figure depicts the planned Actuated Hybrid Mirror Telescope (AHMT), which is intended to demonstrate a new approach to the design and construction of wide-aperture spaceborne telescopes for astronomy and Earth science. This technology is also appropriate for Earth-based telescopes. The new approach can be broadly summarized as using advanced lightweight mirrors that can be manufactured rapidly at relatively low cost. More specifically, it is planned to use precise replicated metallic nanolaminate mirrors to obtain the required high-quality optical finishes. Lightweight, dimensionally stable silicon carbide (SiC) structures will support the nanolaminate mirrors in the required surface figures. To enable diffraction- limited telescope performance, errors in surface figures will be corrected by use of mirror-shape-control actuators that will be energized, as needed, by a wave-front-sensing and control system. The concepts of nanolaminate materials and mirrors made from nanolaminate materials were discussed in several previous NASA Tech Briefs articles. Nanolaminates constitute a relatively new class of materials that can approach theoretical limits of stiffness and strength. Nanolaminate mirrors are synthesized by magnetron sputter deposition of metallic alloys and/or compounds on optically precise master surfaces to obtain optical-quality reflector surfaces backed by thin shell structures. As an integral part of the deposition process, a layer of gold that will constitute the reflective surface layer is deposited first, eliminating the need for a subsequent and separate reflective-coating process. The crystallographic textures of the nanolaminate will be controlled to optimize the performance of the mirror. The entire deposition process for making a nanolaminate mirror takes less than 100 hours, regardless of the mirror diameter. Each nanolaminate mirror will be bonded to its lightweight SiC supporting structure. The lightweight nanolaminate mirrors and SiC supporting structures will be fabricated from reusable master molds. The mirror-shape-control actuators will be low-power, high-capacitance lead magnesium niobate electrostrictive actuators that will be embedded in the SiC structures. The mode of operation of these actuators will be such that once power was applied, they will change in length and once power was removed, they will maintain dimensional stability to nanometer precision. This mode of operation will enable the use of low-power, minimally complex electronic control circuitry. The wave-front-sensing and control system will be designed and built according to a two-stage architecture. The first stage will be implemented by a Shack- Hartmann (SH) sensor subsystem, which will provide a large capture range. The second, higher-performance stage will be implemented by an image-based wave-front-sensing subsystem that will include a phase-retrieval camera (PRC), and will utilize phase retrieval and other techniques to measure wavefront error directly. Phase retrieval is a process in which multiple images of an unresolved object are iterated to estimate the phase of the optical system that acquired the images. The combination of SH and phase-retrieval sensors will afford the virtues of both a dynamic range of 105 and an accuracy of <10 nm.

Hickey, Gregory↗

Preparing for the Next Generation of EUV Lithography at the Center for X-ray Optics

The introduction of EUV lithography into high-volume semiconductor manufacturing this year represents a monumental milestone for EUV technology. After nearly 30 years of development, the EUV research community has overcome many of the key obstacles required to enable the long-awaited integration of EUV lithography into the lab. These obstacles have included: the development of a stable, high-powered EUV source to ensure adequate exposure tool reliability; controlling EUV mask defects and mask contamination; and the development of EUV resists with adequate sensitivity, resolution, and line width roughness to meet the tolerances required for high-volume manufacturing. As EUV moves into its second generation, there will be new challenges facing the community as it works to push EUV technology into the future. Smaller feature sizes will be achieved using higher numerical aperture optics, which are planned to have an anamorphic geometry (asymmetric magnification and numerical aperture between horizontal and vertical axes) to overcome 3D effects at the mask. This new geometry and its larger angle ranges make understanding mask absorber and multilayer effects all the more important. New methods for high-NA wavefront metrology need to be tested to ensure that these optical systems can be aligned to operate with minimal aberrations. Mask defects need to continue to be studied, and the inclusion of EUV pellicles in the roadmap requires that mask inspection and review systems adapt accordingly. Finally, new resists must be developed to support the increased resolution of feature sizes below 8 nm half pitch. The Center for X-ray Optics (CXRO) at Berkeley Lab has been a leader in EUV research for the past 25 years. Leveraging 13.5 nm EUV light from the Advanced Light Source synchrotron facility, CXRO is home to several EUV and soft X-ray (SXR) research tools that have provided important insights into EUV resists, masks, and coatings. The 0.3 NA Microfield exposure tool (MET) and Dose Calibration Tool (DCT) have played an instrumental role in the development of the current generation of high-resolution EUV resists. The Actinic Inspection Tool (AIT) and its successor, SHARP, have enabled aerial image analysis, providing key insights into mask defects, 3D mask effects, illumination, and aberrations. And the CXRO Reflectometer continues to be the industry standard in multilayer coating and EUV mask scattering metrology. To address the new challenges facing the next generation of EUV lithography, CXRO has upgraded its suite of EUV research tools. The 0.5 NA MET5 is a newly commissioned projection lithography tool that is capable of printing feature sizes down to 8 nm half pitch. A new radiation chemistry program is deploying several techniques aimed at dissecting the role of primary photoelectrons and secondary electrons in EUV resists. The SHARP microscope has been outfitted with anamorphic zone plate lenses that can emulate the geometry of next-generation EUV scanners, and the reflectometer has been applied to new scattering experiments for the purpose of understanding the 3D effects of EUV mask multilayers, as well as determining mask properties using scattering profiles. In parallel with these tools, the CXRO High-NA Wavefront Sensing Program is developing high-resolution wavefront sensors suitable for measuring aberrations at high NA. This article presents an overview of these programs and describes how they will address the primary challenges that face the EUV community as it moves to the next generation of EUV lithography.

47 OTHER INSTRUMENTATION↗

Distributed Capacitive Sensor for Sample Mass Measurement

Previous robotic sample return missions lacked in situ sample verification/ quantity measurement instruments. Therefore, the outcome of the mission remained unclear until spacecraft return. In situ sample verification systems such as this Distributed Capacitive (DisC) sensor would enable an unmanned spacecraft system to re-attempt the sample acquisition procedures until the capture of desired sample quantity is positively confirmed, thereby maximizing the prospect for scientific reward. The DisC device contains a 10-cm-diameter pressure-sensitive elastic membrane placed at the bottom of a sample canister. The membrane deforms under the weight of accumulating planetary sample. The membrane is positioned in close proximity to an opposing rigid substrate with a narrow gap. The deformation of the membrane makes the gap narrower, resulting in increased capacitance between the two parallel plates (elastic membrane and rigid substrate). C-V conversion circuits on a nearby PCB (printed circuit board) provide capacitance readout via LVDS (low-voltage differential signaling) interface. The capacitance method was chosen over other potential approaches such as the piezoelectric method because of its inherent temperature stability advantage. A reference capacitor and temperature sensor are embedded in the system to compensate for temperature effects. The pressure-sensitive membranes are aluminum 6061, stainless steel (SUS) 403, and metal-coated polyimide plates. The thicknesses of these membranes range from 250 to 500 m. The rigid substrate is made with a 1- to 2-mm-thick wafer of one of the following materials depending on the application requirements glass, silicon, polyimide, PCB substrate. The glass substrate is fabricated by a microelectromechanical systems (MEMS) fabrication approach. Several concentric electrode patterns are printed on the substrate. The initial gap between the two plates, 100 m, is defined by a silicon spacer ring that is anodically bonded to the glass substrate. The fabricated proof-of-concept devices have successfully demonstrated tens to hundreds of picofarads of capacitance change when a simulated sample (100 g to 500 g) is placed on the membrane.

Toda, Risaku↗

An Overview of Experiments and Modeling of Polysiloxane-Coated Thermal Protection Systems for Missions to Mars, Titan, and Beyond.

Phenolic Impregnated Carbon Ablator (PICA) gained heritage during the historic Stardust mission, where it successfully returned samples from a comet’s tail and has since been instrumental in delivering payloads to the surface of Mars [1-3]. Most recently, PICA enabled the safe return of samples collected from asteroid Bennu as part of the OSIRIS-REx mission. This rich legacy underscores PICA’s critical role in allowing NASA’s most ambitious exploration missions. However, the friable nature of its phenolic phase presents challenges during handling and pre-launch activities. To mitigate this issue, PICA is coated with a polysiloxane resin system, which serves to suppress particulate dispersion and thereby safeguard spacecraft components. A comprehensive understanding of the polysiloxane resin’s behavior is imperative, as it profoundly shapes the material response of PICA during atmospheric entry by influencing its thermal and oxidative stability. This influence extends to thermocouple plugs embedded within thermal protection systems. These plugs have demonstrated their significance in missions such as Mars Science Laboratory (MSL) and Mars 2020, where the MEDLI and MEDLI2 instrumentation suites delivered in-valuable insights into the performance of thermal protection systems during entry into the Martian atmosphere [4]. Looking ahead, missions such as Dragonfly, set to descend into Titan’s dense atmosphere, aim to leverage advanced sensor technologies to further refine our understanding of thermal protection response [5]. Moreover, thermocouple plugs play an essential role in validating cutting-edge material response models, such as those pioneered under NASA’s Entry Systems Modeling Project (ESM), designed, in-part, to predict the operational integrity of thermal protection systems under the extreme stresses of atmospheric entry. To achieve these modeling goals, ground-based experiments are crucial to provide the foundational data necessary for developing and refining these predictive tools. To this end, an extensive test campaign was conducted at the Hypersonic Materials Environmental Test System (HyMETS) to investigate the high-temperature behavior of the polysiloxane resin in an air environment [6]. These experiments revealed critical phenomena, including the formation of a silicon oxycarbide layer that enhances oxidation resistance, moderates surface temperatures, and alters in-depth thermal response. Building on these findings, subsequent tests were designed to simulate atmospheric entry conditions in reactive gases, such as CO2 and N2, to mimic the environments of Mars and Titan, respectively, as well as non-reactive gases representing the atmospheres of the Ice Giants (Neptune and Uranus). A heating rate dependent decomposition mechanism has been identified for the polysiloxane resin under oxidizing conditions (Fig. 1). In the initial stage, the resin and the underlying thermal protection system undergo pyrolysis, rapidly generating a thin amorphous silicon oxycarbide interwoven with carbonaceous char and residual fibers from PICA. During the second stage, the nascent oxide layer establishes a robust, oxidation-resistant thermal barrier coating, which significantly impedes heat transfer to the underlying carbonaceous char, resulting in a stagnation of the surface temperature. A key factor contributing to this thermal resistance is the low recombination efficiency of atomic oxygen (γ), which further diminishes the heat load on the material’s interior layers [7]. Moreover, as the surface temperature stagnates, the silicon oxycarbide phase separates into distinct regions of silica and free graphite. Ultimately, when the heat flux reaches a critical threshold, a third stage is triggered, leading to the breakdown of the coating through carbothermal reduction, exposing the underlying char layer. This exposure leads to a dramatic surface temperature spike, driven by highly exothermic reactions between atomic oxygen and the char layer, further accelerating material degradation. A detailed mass and heat transfer model of PICA coated with polysiloxane resin was implemented in the Porous material Analysis Toolbox based on OpenFOAM, PATO [8]. The initial stage was considered negligible in this model because the resin decomposition occurs rapidly within a thin surface layer. Instead, the coating was directly considered as an oxygen-resistant thermal barrier coating. For the second stage, the thin amorphous silicon oxycarbide was treated as a pure silica surface to simplify the thermochemical behavior. The model ac-counts for surface equilibrium processes using representative elements of the coating-environment system. For the third stage, specific boundary conditions were developed to estimate the onset and progression of the coating removal. Two-dimensional material response simulations were conducted to compare uncoated and coated PICA using boundary conditions calibrated with HyMETS data. Fig. 2 illustrates that the simulations closely align with experimental data, successfully reproducing measured temperature profiles. This work will include the latest advancements in the coating model, including the calibration of recombination of atomic oxygen at the surface during the second phase. These simulated results will be further validated against additional CO2 data points from HyMETS, reinforcing the models’ predictive capabilities. These mechanisms and their effects on thermal protection systems, including thermochemical behavior and thermocouple probe performance in extreme environments, provide crucial insights for optimizing spacecraft designs that safeguard scientific payload and ensure mission success in future planetary exploration endeavors.

Active Oxidation↗

Large Area Picosecond Photodetector (LAPPD TM ) - Pilot production and development status

Here, we discuss performance results achieved for fully functional sealed Large Area Picosecond Photodetectors (LAPPD (TM)) in tests performed at Incom Inc., as well as independent test results reported by our early adopters. The LAPPD is a microchannel plate (MCP) based large area picosecond photodetector, capable of imaging with single-photon sensitivity at high spatial and temporal resolutions in a hermetic package. The LAPPD has an active area of 350 square centimeters in an all-glass hermetic package with a fused silica window and bottom plate and sidewalls made of borosilicate float glass. Signals are generated by a bi-alkali Na 2 KSb photocathode and amplified with a stacked chevron pair of MCPs produced by applying resistive and emissive atomic layer deposition coatings to glass capillary array (GCA) substrates. Signals are collected on RF stripline anodes applied to the bottom plates which exit the detector via pin-free hermetic seals under the side walls. LAPPD test and performance results for product produced and delivered to early adopter customers during the first half of 2018 are reviewed. These results include electron gains ≥ 7.5 x 10 6 @ 850/950 V (entry/exit MCP), low dark noise rates (22 Cts/s/cm 2 ), single photoelectron (PE) timing resolution of 64 picoseconds RMS, and single photoelectron spatial resolution along and across strips of 2.8 mm and 1.3 mm RMS respectively. Many of these devices also had very high QE photocathodes that were uniform over the full 195 mm x 195 mm window active area (LAPPD #15 QE% @ 365 nm Max/Avg/Min = 25.8/22.3 ± 3/15.7). An update is additionally provided of developments that enable capacitive signal coupling from the detector to application specific pads or stripline readout patterns deployed on printed circuit boards positioned beneath the file, outside of the vacuum package. We conclude with examples of how sensors offering picosecond timing, in diverse applications can bring transformative change to detector technology and applications in future experiments.

47 OTHER INSTRUMENTATION↗

Science and Science-Enabling Activities of the SHERLOC and WATSON Imaging Systems in Jezero Crater, Mars

During its first year of operation, the Perseverance rover explored the cratered and fractured floor of Jezero crater on Mars. Here, we report the use of the Scanning Habitability Environments with Raman and Luminescence for Organics and Chemicals (SHERLOC) imaging system that includes two high-resolution cameras, the Autofocus and Contextual Imager (ACI) and Wide Angle Topographic Sensor for Operations and eNgineering (WATSON). ACI is a fixed focus gray scale imager with a resolution of 10.1 μm/pixel whereas WATSON is a variable field of view, variable focus imager capable of resolution down to 14 μm/pixel. WATSON is a reflight of the MArs Hand Lens Imager (MAHLI) imager and has similar capabilities. During first-time activities, WATSON was used to support both science and engineering operations related to sample and abrasion patch assessment and sample collection and caching. WATSON also documented the deployment of the Ingenuity helicopter. The Crater Floor Campaign identified two primary rock units, the Máaz formation and the Séítah formation, which have been interpreted as lava flows and an olivine cumulate, respectively. Interpretation of rock textures with WATSON and ACI images was limited to abraded surfaces because unmodified outcrop surfaces (herein termed “natural surfaces”) show high degrees of dust covering, wind abrasion, and coating by secondary mineral products. WATSON and ACI images support the hypothesis that the material of both the Máaz and Séítah formations consists of largely aqueously altered mafic materials with varying igneous origins.

WATSON↗

NASA Tech Briefs, January 2012

Contents of this issue are: (1) Energy-Based Tetrahedron Sensor for High-Temperature, High-Pressure Environments (2) Handheld Universal Diagnostic Sensor (3) Large-Area Vacuum Ultraviolet Sensors (4) Fiber Bragg Grating Sensor System for Monitoring Smart Composite Aerospace Structures (5) Health-Enabled Smart Sensor Fusion Technology (6) Extended-Range Passive RFID and Sensor Tags (7) Hybrid Collaborative Learning for Classification and Clustering in Sensor Networks (8) Self-Healing, Inflatable, Rigidizable Shelter (9) Improvements in Cold-Plate Fabrication (10) Technique for Radiometer and Antenna Array Calibration - TRAAC (11) Real-Time Cognitive Computing Architecture for Data Fusion in a Dynamic Environment (12) Programmable Digital Controller (13) Use of CCSDS Packets Over SpaceWire to Control Hardware (14) Key Decision Record Creation and Approval Module (15) Enhanced Graphics for Extended Scale Range (16) Debris Examination Using Ballistic and Radar Integrated Software (17) Data Distribution System (DDS) and Solar Dynamic Observatory Ground Station (SDOGS) (18) Integration Manager (19) Eclipse-Free-Time Assessment Tool for IRIS (20) Automated and Manual Rocket Crater Measurement Software (21) MATLAB Stability and Control Toolbox Trim and Static Stability Module (22) Patched Conic Trajectory Code (23) Ring Image Analyzer (24) SureTrak Probability of Impact Display (25) Implementation of a Non-Metallic Barrier in an Electric Motor (26) Multi-Mission Radioisotope Thermoelectric Generator Heat Exchangers for the Mars Science Laboratory Rover (27) Uniform Dust Distributor for Testing Radiative Emittance of Dust-Coated Surfaces (28) MicroProbe Small Unmanned Aerial System (29) Highly Stable and Active Catalyst for Sabatier Reactions (30) Better Proton-Conducting Polymers for Fuel-Cell Membranes (31) CCD Camera Lens Interface for Real-Time Theodolite Alignment (32) Peregrine 100-km Sounding Rocket Project (33) SOFIA Closed- and Open-Door Aerodynamic Analyses (34) Sonic Thermometer for High-Altitude Balloons (35) Near-Infrared Photon-Counting Camera for High-Sensitivity Observations (36) Integrated Optics Achromatic Nuller for Stellar Interferometry (37) High-Speed Digital Interferometry (38) Ultra-Miniature Lidar Scanner for Launch Range Data Collection (39) Shape and Color Features for Object Recognition Search (40) Explanation Capabilities for Behavior-Based Robot Control (41) A DNA-Inspired Encryption Methodology for Secure, Mobile Ad Hoc Networks (42) Quality Control Method for a Micro-Nano-Channel Microfabricated Device (43) Corner-Cube Retroreflector Instrument for Advanced Lunar Laser Ranging (44) Electrospray Collection of Lunar Dust (45) Fabrication of a Kilopixel Array of Superconducting Microcalorimeters with Microstripline Wiring Spacecraft Attitude Tracking and Maneuver Using Combined Magnetic Actuators (46) Coherent Detector for Near-Angle Scattering and Polarization Characterization of Telescope Mirror Coatings

Source record↗

Film Growth Dynamics During Pulsed Sputter Deposition (LDRD Final Report)

Novel materials synthesis and development using physical vapor deposition require our fundamental understanding of plasma conditions and film growth dynamics. A central theme is to control materials microstructure. Over the last few decades, the difficulty of thick heavy metal coatings has been one of the major bottlenecks limiting our studies of the important family of inertial-confinement-fusion (ICF) designs with colliding-shell targets. Our previous attempts to fabricate such coatings by conventional DC magnetron sputtering (DCMS) has had limited success due to the inherent complexity and our limited understanding of the deposition process. In this project, we have investigated the physics of a novel and promising pulsed sputter deposition process. We expanded the scientific foundation of sputter deposition processes through a combination of well-posed experiments and state-of-the-art characterizations. The following important scientific milestones have been achieved: (1) Successfully installed and tested a high-power impulse magnetron sputtering (HiPIMS) system; (2) Deployed a novel set of in-situ diagnostics during pulsed deposition, including a multibeam optical stress sensor (MOSS) system for real-time stress measurement, and Langmuir probe for the measurements of plasma physical properties. This allows us to monitor dynamically plasma conditions, ion flux and energy distributions, and film stress; (3) Investigated and obtained a fundamental understanding of HIPIMS on microstructure and stress control; (4) Successfully synthesized and demonstrated record-breaking strength nanocrystalline-nanotwinned (nnt) metals; (5) Successfully obtained high-quality, leak-proof Cr metal shells via HiPIMS method. The outcomes of this project could have transformational scientific and programmatic impacts, enabling novel materials synthesis and an experimental campaign with colliding shell target designs. The basic understanding of the deposition process has important implications to a broad range of industrial applications.

36 MATERIALS SCIENCE↗

Current Developments in Future Planetary Probe Sensors for TPS

In-situ Thermal Protection System (TPS) sensors are required to provide traceability of TPS performance and sizing tools. Traceability will lead to higher fidelity design tools, which in turn will lead to lower design safety margins, and decreased heatshield mass. Decreasing TPS mass will enable certain missions that are not otherwise feasible, and directly increase science payload. NASA Ames is currently developing two flight measurements as essential to advancing the state of TPS traceability for material modeling and aerothermal simulation: heat flux and surface recession (for ablators). The heat flux gage is applicable to both ablators and non-ablators and is therefore the more generalized sensor concept of the two with wider applicability to mission scenarios. This paper describes the development of a microsensor capable of surface and in-depth temperature and heat flux measurements for TPS materials appropriate to Titan, Neptune, and Mars aerocapture, and direct entry. The thermal sensor will be monolithic solid state devices composed of thick film platinum RTD on an alumina substrate. Choice of materials and critical dimensions are used to tailor gage response, determined during calibration activities, to specific (forebody vs. aftbody) heating environments. Current design has maximum operating temperature of 1500 K, and allowable constant heat flux of q=28.7 watts per square centimeter, and time constants between 0.05 and 0.2 seconds. The catalytic and radiative response of these heat flux gages can also be changed through the use of appropriate coatings. By using several co-located gages with various surface coatings, data can be obtained to isolate surface heat flux components due to radiation, catalycity and convection. Selectivity to radiative heat flux is a useful feature even for an in-depth gage, as radiative transport may be a significant heat transport mechanism for porous TPS materials in Titan aerocapture. This paper also reports on progress to adapt a previously flown surface recession sensor, based on the Jupiter probe Galileo Analog Resistance Ablation Detector (ARAD), to appropriate aerocapture conditions.

Martinez, Ed↗

Development of Solid State Thermal Sensors for Aeroshell TPS Flight Applications

In-situ Thermal Protection System (TPS) sensors are required to provide verification by traceability of TPS performance and sizing tools. Traceability will lead to higher fidelity design tools, which in turn will lead to lower design safety margins, and decreased heatshield mass. Decreasing TPS mass will enable certain missions that are not otherwise feasible, and directly increase science payload. NASA Ames is currently developing two flight measurements as essential to advancing the state of TPS traceability for material modeling and aerothermal simulation: heat flux and surface recession (for ablators). The heat flux gage is applicable to both ablators and non-ablators and is therefore the more generalized sensor concept of the two with wider applicability to mission scenarios. This paper describes the continuing development of a thermal microsensor capable of surface and in-depth temperature and heat flux measurements for TPS materials appropriate to Titan, Neptune, and Mars aerocapture, and direct entry. The thermal sensor is a monolithic solid state device composed of thick film platinum RTD on an alumina substrate. Choice of materials and critical dimensions are used to tailor gage response, determined during calibration activities, to specific (forebody vs. aftbody) heating environments. Current design has maximum operating temperature of 1500K, and allowable constant heat flux of q=28.7 W/cm(sup 2), and time constants between 0.05 and 0.2 seconds. The catalytic and radiative response of these heat flux gages can also be changed through the use of appropriate coatings. By using several co-located gages with various surface coatings, data can be obtained to isolate surface heat flux components due to radiation, catalycity and convection. Selectivity to radiative heat flux is a useful feature even for an in-depth gage, as radiative transport may be a significant heat transport mechanism for porous TPS materials in Titan aerocapture.

Martinez, Ed↗

Host-Directed, Bioelectronic Immunomodulation for Protection Against Emerging Pathogens

Acute care of patients with severe infections often relies on systemic administration of pharmaceuticals and monitoring of complex physiological symptoms to identify immune system dysfunction, which can lead to increased mortality. Furthermore, determining disease-specific treatment plans often leads to a delay in patient care. To address this, we proposed an immune modulation system that electrically detects and responds to a patient’s immune system status, creating an agnostic means of treating illness and infection. Two pieces of hardware were developed for this task: a minimally-invasive sensor and a vagus nerve stimulator. Stimulation of the vagus nerve is known to modulate the immune system. The sensor is a microfabricated, silicon-based microneedle array capable of interfacing with interstitial fluid to detect small molecules such as inflammatory proteins (cytokines) and pharmaceuticals (vancomycin). Process optimization to manufacture the needles refined the silicon etch process, creating needle patches long enough to penetrate skin and reach interstitial fluid. The needles were tested for mechanical strength and stability, and did not shatter when inserted into skin models. The needles are coated with a thin film metal, turning them into electrodes for electrochemical sensing of our target molecules. We hybridized aptamers to the surface of the electrode to act as the sensing layer and were able to detect changes in the conformation of the aptamer electrochemically in the presence of the target molecule. The stimulator was a cuff electrode that encircled the vagus nerve. Rodent studies were conducted in which rodents were exposed to an inflammatory event and vagus nerve stimulation (VNS) was applied. It was demonstrated that optimized electrical stimulation of the vagus nerve created measurably different levels of cytokines in blood samples, and certain cytokines released during the inflammatory event were either upregulated or downregulated. In sum, this project successfully developed new platforms and technologies that can, with further development, enable better temporal insight into biomarker changes in the body, letting healthcare providers know of possible immune system dysfunction before they are detected physiologically. We also demonstrated the value of VNS and its possible use in treating immune system response to inflammation and illness.

59 BASIC BIOLOGICAL SCIENCES↗