Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “secondary frequency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Advanced Sensor Deployment for Distribution System State Estimation and Fault Identification: Preprint

Distribution systems are currently facing steep operational challenges as a result of the rapidly increasing integration of renewables and other distributed energy resources (DERs)at both the primary and secondary circuit levels. Distribution utilities and system operators have traditionally had some visibility of their primary circuits using low-frequency supervisory control and data acquisition systems, and they have had very poor if not zero visibility of the secondary circuits where the presence of DERs is constantly increasing. Therefore, this paper presents simulation studies to demonstrate the benefits of an advanced, high-fidelity sensor technology, called as the Meta-Alert System (MAS), developed by Electrical Grid Monitoring Ltd. (EGM), on the distribution grid. First, a reliable model of the EGM sensors is developed, and then two use cases - distribution system state estimation (DSSE) and fault identification - are simulated to evaluate the performance of the MAS technology. Simulation results on the Electric Power Research Institute J1feeder demonstrate that the MAS can effectively participate in system-level DSSE programs and can detect and locate faults faster than traditional distribution protection schemes.

distribution system monitoring↗

A Comparative Study of Ethanol Upgrading to Butadiene Over Rare Earth Elements Incorporated in Dealuminated Beta Zeolites

Copper and rare earth element-containing dealuminated Beta zeolites (CuREE/deAlBeta) are promising catalysts for the conversion of ethanol to C 3+ olefins en route to sustainable aviation fuel. Product selectivities over CuREE/deAlBeta depend on the identity of the REE. Here, in this study, a suite of La/deAlBeta catalysts of varied La loading are prepared, and their reactivities, selectivities, and apparent C-C coupling kinetics in the cascade reaction between ethanol and acetaldehyde are reported. Ex situ and in situ titrations to quantify Lewis acidic La sites quantify distinct numbers of sites, suggesting a distribution of site types. Across a series of REE/deAlBeta catalysts (REE = Y, La, Lu, Yb, Gd), the selectivity to secondary products correlates with the pyridine heats of adsorption at REE Lewis acid sites. The turnover frequency (per Lewis acid site) for C–C coupling was similar across the series of REE/deAlBeta catalysts. Y/deAlBeta and La/deAlBeta, which have the most disparate secondary product selectivities, had similar kinetics for C–C coupling. These findings demonstrate the complexity of quantifying active sites in REE/deAlBeta zeolites, and the sensitivity of the selectivity, but not the reactivity for C–C coupling, to the identity of the REE atom in REE/deAlBeta zeolites.

alcohol upgrading↗

Using a Grid-Forming Inverter to Stabilize a Low-Inertia Power System - Maui Hawaiian Island

As power systems around the world integrate greater amounts of wind and solar photovoltaic power, periods of very high instantaneous power shares of inverters, the primary interfacing technology for these generation sources, are complicating system stability and control. The contemporary, primary mode of inverter operation, grid-following, which explicitly assumes the presence of a local, stable voltage waveform, yields operational inadequacy at high instantaneous power shares potentially leading to instability due to the low-inertia conditions, as well as the correlated reduced voltage forming capacity on the respective system. Parallel connected grid-forming inverters, which directly regulate the local voltage, are a solution that is expected to bolster system stability and mitigate the shortcomings of the grid-following technology. In this paper, grid-following and two types of grid-forming inverter control, the traditional linear droop and the recently introduced nonlinear exponential droop (Droop-e), are simulated on a low-inertia, H = 0.48s, high inverter-based resource scenario, 97%, with a validated electromagentic transient domain model of the Hawaiian island of Maui power system. The benefit of a single grid-forming device over its grid-following counterpart is significant, both in terms frequency deviation and voltage stability. Further, the superiority of the Droop-e and the associated secondary power sharing control over both grid-following and linear droop grid-forming technologies is displayed, with improved nadir and rate of change of frequency over the linear droop control.

droop control↗

Distributed Secondary Control of Grid-Forming Inverters and AC Microgrids: Impacts of Voltage Feedback Choices

In this paper, the operational choices in distributed secondary control are examined, and their impacts on grid-forming (GFM) inverters and grid operation are investigated. In particular, the effects of feedback voltage choices, either average voltage feedback (AVF) or terminal voltage feedback (TVF), are studied with respect to reactive power sharing, voltage regulation, and grid-forming operation during black start. The secondary control used is a subgradient-based distributed cooperative control, and it provides the voltage, angle, and frequency references to the GFM inverters and their primary tracking controls. The overall control architecture employs multi-rate sampling such that the secondary control is slower than the primary control. The operational choices and their control performance are illustrated using a four-GFM-inverter microgrid in MATLAB/SIMULINK. Furthermore, the results show the effectiveness of the secondary controller, and several conclusions are drawn on the voltage feedback signals as the design choices.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Quasi‐dynamic breathing model of the lung incorporating viscoelasticity of the lung tissue

Abstract We advanced a novel model to calculate viscoelastic lung compliance and airflow resistance in presence of mucus, accounting for the quasi‐linear viscoelastic stress–strain response of the parenchyma (alveoli) tissue. We adapted a continuum‐based numerical modeling approach for the lung, integrating the fluid mechanics of the airflow within individual generations of the bronchi and alveoli. The model accounts for elasticity of the deformable bronchioles, resistance to airflow due to the presence of mucus within the bronchioles, and subsequent mucus flow. Simulated quasi‐dynamic inhalation and expiration cycles were used to characterize the net compliance and resistance of the lung, considering the rheology of the mucus and viscoelastic properties of the parenchyma tissue. The structure and material properties of the lung were identified to have an important contribution to the lung compliance and airflow resistance. The secondary objective of this work was to assess whether a higher frequency and smaller volume of harmonic air flow rate compared to a normal ventilator breathing cycle enhanced mucus outflow. Results predict, lower mucus viscosity and higher excitation frequency of breathing are favorable for the flow of mucus up the bronchi tree, towards the trachea.

60 APPLIED LIFE SCIENCES↗

History of Ultrasonic Inspection of High-Level Waste Tanks at SRS - 20220

The Liquid Waste Disposition Projects (LWDP) Structural Authority and Inspection Engineering Support Group has teamed with the Materials Science and Technology Non-destructive Evaluation Group of Savannah River National Laboratory (SRNL) to implement a comprehensive In-Service Inspection (ISI) program for the High-Level Waste (HLW) tanks in the sites tank farms. The purpose of this program is to demonstrate the structural and leak integrity of the tanks to maintain the function of waste containment throughout the desired service life. Four types of waste tanks were constructed at Savannah River Site (SRS) from 1951 thru 1981 to store radioactive nuclear waste from the separations process. The Type I, II and III are carbon steel cylindrical tanks with varying degrees of access to the side walls and very limited access to the tank bottom. The tanks contain 750,000 to 1.3 million gallons of waste and are buried or backfilled with soil. The tanks are 75'-85' in diameter and 24'-33' from tank bottom to the tank roof. Inspection of the HLW tanks is made difficult by radiation, contamination, and small access openings. Through the years these challenges have been overcome by progressive improvements to programs and equipment resulting in the sophisticated wall crawler Ultrasonic Testing (UT) technology of today. A formal inspection program was developed and put in service in 1972. UT thickness measurements were first made in 1967 and 1969 of selected waste tanks using an analog-type instrument to measure the thickness of the carbon steel walls. Routine inspections for thinning were performed from 1972-1985 and then discontinued because no thinning had been observed and this technique could not detect pitting or cracking. UT inspections resumed in 1994 using a sophisticated robotic wall crawler with UT technology capable of detecting thinning, cracking and pitting. The current program focuses on the newer Type III tanks that are used primarily for storage. The program was upgraded in 2003 to include selected regions of the tank wall, secondary wall and annulus floor on a 7 to 10-year frequency. The facility is currently in its third cycle of tank inspections. Thus far, there have been no reportable indications of service induced degradation. This result provides assurance that the chemistry control program has been effective at mitigating corrosion and that the tanks remain structurally sound even after more than 40 years of service. This paper will present the UT technology first used at SRS and the evolution to the current systems and their capabilities. Additionally, plans for equipment upgrades that will improve the extent of inspection will be discussed. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Pre-He White Dwarfs in Eclipsing Binaries. II. WASP 0843–11

We present the Transiting Exoplanet Survey Satellite (TESS) photometry and our high-resolution spectra of the EL CVn–type star 1SWASP J084356.46–113327.5 (WASP 0843–11), which consists of an F-type main-sequence (MS) star and a hotter low-mass helium white dwarf precursor (pre-He WD). In a spectral analysis, double-lined radial velocities (RVs) were obtained for the first time. From a simultaneous analysis of the TESS light and RV curves, the masses, radii, and temperatures of each component were determined to be M {sub 1} = 1.733 ± 0.031 M {sub ⊙}, M {sub 2} = 0.220 ± 0.008 M {sub ⊙}, R {sub 1} = 2.094 ± 0.013 R {sub ⊙}, R {sub 2} = 0.331 ± 0.003 R {sub ⊙}, T {sub 1} = 6960 ± 120 K, and T {sub 2} =9870 ± 310 K, respectively. According to their physical properties, the primary and secondary stars are located on the instability strips of δ Sct/γ Dor hybrids and extremely low-mass WDs, respectively. We applied multiple frequency analyses to the residual light curve after subtracting the binarity effects and detected a total of four independent frequencies. A frequency of f {sub 3} = 1.6356 day{sup −1} in the low-frequency region was reminiscent of γ Dor stars, while the other three frequencies of f {sub 2}, f {sub 15}, and f {sub 18} in the high-frequency region (150–196 day{sup −1}) are probably related to pre-He WD components. Our results demonstrate that the more massive MS primary star of WASP 0843–11 is a γ Dor pulsator, whereas the hotter secondary component is a pre-He WD with high-frequency pulsations.

47 OTHER INSTRUMENTATION↗

Coordinated Frequency Regulation in Grid-Forming Storage Network via Safety-Consensus

Inverter-based storages are poised to play a prominent role in future power grid with massive renewable generation. Grid-forming inverters (GFMs) are emerging as a dominant technology with synchronous generators (SG)-like characteristics through primary control loops. Advanced secondary-layer control schemes, e.g., consensus algorithms, allow GFM-interfaced storage units to participate in frequency regulations and restore nominal frequency following grid disturbances. However, it is imperative to ensure critical frequency safety limits are not violated while the grid transitions from pre- to post-disturbance operating point. This paper presents a novel safety-enforced consensus method, having three distinct objectives: safe transient frequency evolution, minimizing frequency deviation, and coordinated power sharing. The proposed technique is illustrated using a GFM-interfaced grid-wide storage network on the IEEE 68-bus system under multiple grid transient scenarios.

consensus control↗

Analysis of putative quadruplex-forming sequences in fungal genomes: novel antifungal targets?

Fungal infections cause >1 million deaths annually and the emergence of antifungal resistance has prompted the exploration for novel antifungal targets. Quadruplexes are four-stranded nucleic acid secondary structures, which can regulate processes such as transcription, translation, replication and recombination. They are also found in genes linked to virulence in microbes, and ligands that bind to quadruplexes can eliminate drug-resistant pathogens. Using a computational approach, we quantified putative quadruplex-forming sequences (PQS) in 1359 genomes across the fungal kingdom and explored their presence in genes related to virulence, drug resistance and biological processes associated with pathogenicity in Aspergillus fumigatus. Here we present the largest analysis of PQS in fungi and identify significant heterogeneity of these sequences throughout phyla, genera and species. PQS were genetically conserved in Aspergillus spp. and frequently pathogenic species appeared to contain fewer PQS than their lesser/non-pathogenic counterparts. GO-term analysis identified that PQS-containing genes were involved in processes linked with virulence such as zinc ion binding, the biosynthesis of secondary metabolites and regulation of transcription in A. fumigatus. Although the genome frequency of PQS was lower in A. fumigatus, PQS could be found enriched in genes involved in virulence, and genes upregulated during germination and hypoxia. Moreover, PQS were found in genes involved in drug resistance. Quadruplexes could have important roles within fungal biology and virulence, but their roles require further elucidation.

59 BASIC BIOLOGICAL SCIENCES↗

Impacts of Experimentally Obtained Harmonic Spectrums of Residential Appliances on Distribution Feeder

Owing to the increased use of power electronic based appliances and energy-efficient home equipment such as modern lighting loads, the percentage of nonlinear loads has increased in the distribution system, which can impact system performance, loss, and stability. Thus a comprehensive knowledge of their power quality and harmonic analysis is essential to improve the load models, voltage stability assessment, determination of possible interactions at harmonic frequencies, protection planning, and the effect of system impedance. This paper focuses on harmonic load flow analysis for multiple residential load types to determine the expected impacts on an modeled distribution secondary. For this study, the household appliances include lighting, power electronic, resistive, and motor loads with a nominal supply voltage of 120 V single-phase or 240 V split phase at a nominal frequency of 60 Hz. The harmonic spectrums, as obtained from the experimental evaluation of real loads, are used to inform the harmonic load flow for a detailed secondary network, including the distribution service transformer extracted from a real distribution feeder's model. Additionally, the impact of voltage harmonics on a three-phase test load is presented with experimental results. The harmonic data of the transformer terminal voltage, as obtained from the former load flow study, are scaled to generate the source voltage for the three-phase configuration of the grid simulator to make the test setup very similar to a typical secondary design in the U.S.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Low modulation index 3-phase solid state transformer

A solid-state transformer (SST) comprises a transformer core, a primary winding, a secondary winding, a primary-side switch bank, and a secondary-side switch bank. Each of the switch banks includes six 4-quadrant switches. The twelve 4-quadrant switches are toggled on and off over six clock cycles in a repetitive sequence with a period that is a function of a desired operating frequency of the transformer. The sequence is configured such that at any given time, 2 of 3 input and output phases are connected to the primary and secondary windings. The SST further includes L-C filter circuits that are configured to filter high-frequency components of current and voltage waveforms such that these components are not back-fed to the electrical mains or delivered to a load. The SST includes a primary-side filter circuit and a secondary-side filter circuit that can each include respective L-C filters for three input or output phases.

Koplow, Jeffrey P.↗

Enhanced collisionless laser absorption in strongly magnetized plasmas

We report that strongly magnetizing a plasma adds a range of waves that do not exist in unmagnetized plasmas and enlarges the laser-plasma interaction (LPI) landscape. In this paper, we use particle-in-cell simulations to investigate strongly magnetized LPI in one dimension under conditions relevant for magneto-inertial fusion experiments, focusing on a regime where the electron-cyclotron frequency is greater than the plasma frequency and the magnetic field is at an oblique angle with respect to the wave vectors. We show that when electron-cyclotron-like hybrid wave frequency is about half the laser frequency, the laser light resonantly decays to magnetized plasma waves via primary and secondary instabilities with large growth rates. These distinct magnetic-field-controlled instabilities, which we collectively call two-magnon decays, are analogous to two-plasmon decays in unmagnetized plasmas. Since additional phase mixing mechanisms are introduced by the oblique magnetic field, collisionless damping of large-amplitude magnetized waves substantially broadens the electron distribution function, especially along the direction of the magnetic field. During this process, energy is transferred efficiently from the laser to plasma waves and then to electrons, leading to a large overall absorptivity when strong resonances are present. The enhanced laser energy absorption may explain hotter-than-expected temperatures observed in magnetized laser implosion experiments and may also be exploited to develop more efficient laser-driven x-ray sources.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A High-Frequency Planar Transformer with Medium-Voltage Isolation

This paper presents the design of a low-loss, high-frequency planar transformer having medium-voltage (10’s of kV) isolation capability while transformer primary and secondary windings are interleaved to reduce losses. Medium-voltage isolation between adjacent printed circuit board (PCB) layers is extremely challenging using traditional PCB dielectrics. The isolation requirement is met using PCB with 7 kV/mil polyimide (Panasonic Felios RF775) as the dielectric, and by an appropriate layout of the windings and the inter-winding vias. The transformer is used to implement a dual active bridge (DAB) converter in a stackable dc-ac architecture where the dc port is connected to a photovoltaic (PV) string and ac outputs are connected in series to achieve direct PV string-to-medium voltage conversion without the need for low-voltage collection or a bulky line frequency transformer. Since each DAB transformer processes time-varying power, a design methodology is developed to minimize line-cycle-averaged losses. Experimental results are presented for a 1:1 planar transformer in a 7.5 kW SiC-based dc-to-ac module operating at 200 kHz. Isolation of 26 kV between the primary and secondary layers and between the windings and the core is verified using a hipot tester.

insulation resistance↗

A High-Frequency Planar Transformer with Medium-Voltage Isolation: Preprint

This paper presents the design of a low-loss, high-frequency planar transformer having medium-voltage (10's of kV) isolation capability while transformer primary and secondary windings are interleaved to reduce losses. Medium-voltage isolation between adjacent printed circuit board (PCB) layers is extremely challenging using traditional PCB dielectrics. The isolation requirement is met using PCB with $7$\,kV/mil polyimide (Panasonic Felios RF775) as the dielectric, and by an appropriate layout of the windings and the inter-winding vias. The transformer is used to implement a dual active bridge (DAB) converter in a stackable dc-ac architecture where the dc port is connected to a photovoltaic (PV) string and ac outputs are connected in series to achieve direct PV string-to-medium voltage conversion without the need for low-voltage collection or a bulky line frequency transformer. Since each DAB transformer processes time-varying power, a design methodology is developed to minimize line-cycle-averaged losses. Experimental results are presented for a 1:1 planar transformer in a 7.5\,kW SiC-based dc-to-ac module operating at 200 kHz. Isolation of 26 kV between the primary and secondary layers and between the windings and the core is verified using a hipot tester.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Design considerations for gallium arsenide pulse compression photoconductive switch

In this paper, we present the physics and design-space exploration of a novel pulse compression photoconductive switch (PCPS) using semi-insulating gallium arsenide (GaAs) operating in the negative differential mobility (NDM) regime of electron transport. We systematically quantify the relationship between the PCPS performance and various design options, including contact separation, laser energy and placement, and trap dynamics. Specifically, we report the full-width at half-maximum and the peak output current generated by the PCPS as a function of applied electrical and optical bias. We discuss the optimal spacing between the electrodes and the distance of the laser spot to the anode to achieve higher electron confinement and superior radio-frequency (RF) metrics. Reducing the laser energy is important to prevent the appearance of secondary peaks due to diffusive transport, but there exists a trade-off between the bandwidth and the maximum current of the PCPS. We also compare the PCPS response with and without trap dynamics and find that the electrostatic screening from the trap-induced space charge is time-independent when the trapping time constant is set larger than the recombination lifetime. Overall, trap dynamics are detrimental to performance, unless the compensation doping scheme to achieve semi-insulating GaAs is carefully selected. Results presented in this paper can be used by experimentalists to fine-tune the PCPS design parameters to meet the specifications of various RF applications. Moreover, our results will provide a strong theoretical basis to the measurements of PCPS devices using GaAs and other NDM materials under investigation.

42 ENGINEERING↗

A step towards unveiling the nature of three cataclysmic variables: LS Cam, V902 Mon, and SWIFT J0746.3-1608

ABSTRACT We have carried out detailed time-resolved timing analyses of three cataclysmic variables (CVs) namely LS Cam, V902 Mon, and SWIFT J0746.3-1608, using the long-baseline, high-cadence optical photometric data from the Transiting Exoplanet Survey Satellite. Our analysis of LS Cam observations hints the presence of a superorbital period of ∼4.025 ± 0.007 d along with negative and positive superhump periods of ∼3.30 and 3.70 h, respectively. These results can be explained as an interaction of nodal and apsidal precession of the accretion disc with orbital motion. For the other two sources, V902 Mon and SWIFT J0746.3-1608, we have found evidence of a beat period of 2387.0 ± 0.6 and 2409.5 ± 0.7 s, respectively, which were not found in earlier studies. Our results presented in this study indicate the change in the accretion mode during the entire observing period for both sources. For V902 Mon, an apparent orbital period derivative of (6.09 ± 0.60) × 10−10 was also found. Moreover, the second harmonic of orbital frequency dominates the power spectrum of SWIFT J0746.3-1608, suggestive of ellipsoidal modulation of the secondary star. Present analyses suggest that LS Cam could be a superhumping CV, whereas V902 Mon and SWIFT J0746.3-1608 are likely to be variable disc-overflow accreting intermediate polars.

Rawat, Nikita (ORCID:0000000246336832)↗

Secondary-Side Active Rectifier Synchronization and Control in LCC-LC Compensated Inductive Power Transfer Systems

This paper proposes a communication-less synchronization and output power control strategy for LCC-LC compensated inductive power transfer systems with a secondaryside active rectifier. By replacing the passive rectifier with an active bridge, the proposed architecture eliminates the need for a separate secondary-side DC-DC converter and enables direct regulation of battery power. The key challenge in such a system is achieving robust synchronization of the secondary active bridge with the primary inverter without access to primary-side signals. To address this issue, the secondary-side variables are analyzed and the current through the secondary series inductor is identified as a load-independent synchronization variable with a fixed phase relationship to the primary excitation. A fixed-frequency second order generalized (SOGI)-based phase locked loop (PLL) is used to estimate the switching phase and frequency, and a phase-shift-based output power controller is developed using a phasor-transformer model of the active bridges. A modified control formulation is further introduced to remove phase-dependent loop-gain variation and simplify controller design. Simulation results validate the proposed method under both fixed and varying switching-frequency conditions, demonstrating successful frequency tracking from 82 kHz to 88 kHz and accurate output power regulation over a wide operating range. The proposed method offers a compact and effective solution for high-power IPT systems by enabling secondary-side synchronization and control without wireless communication or an additional DC-DC conversion stage.

Fernandes, Arnold Anthony [ORNL] (ORCID:0009000631↗

A Case Study of Nonresonant Mode 3-s ULF Waves Observed by MMS

The nature of the 3-s ultralow frequency (ULF) wave in the Earth's foreshock region and the associated wave-particle interaction are not yet well understood. In this work, we investigate the 3-s ULF waves using Magnetospheric Multiscale (MMS) observations. By combining the plasma rest frame wave properties obtained from multiple methods with the instability analysis based on the velocity distribution in the linear wave stage, the ULF wave is determined to be due to the ion/ion nonresonant mode instability. The interaction between the wave and ions is analyzed using the phase relationship between the transverse wave fields and ion velocities and using the longitudinal momentum equation. During the stage when ULF waves have sinusoidal waveforms up to |dB|/|B 0 | ~ 3, where dB is the wave magnetic field and B0 is the background magnetic field, the wave electric fields perpendicular to B 0 do negative work to solar wind ions; along B 0 , a longitudinal electric field develops, but the V × B force is stronger and leads to solar wind ion deceleration. During the same wave stage, the backstreaming beam ions gain energy from the transverse wave fields and get deceleration along B 0 by the longitudinal electric field. The ULF wave leads to electron heating, preferentially in the direction perpendicular to the local magnetic field. Secondary waves are generated within the ULF waveforms, including whistler waves near half of the electron cyclotron frequency, high-frequency electrostatic waves, and magnetosonic whistler waves. The work improves the understanding of the nature of 3-s ULF waves and the associated wave-particle interaction.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗