Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “scanning probe microscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Impacts of Focused Ion Beam Processing on the Fabrication of Nanoscale Functionalized Probes

Herein, we examine the impact of Ga + ion kinetic energy and the target material type on the extent of ion implantation and structural damage in atomic force microscopy probes made of Al 2 O 3 and ZnO manufactured by focused ion beam (FIB) using scanning transmission electron microscopy and energy-dispersive X-ray mapping. Penetration of Ga into the Al 2 O 3 lattice induced structural distortions and amorphization. For ZnO probes, Ga is uniformly dispersed across the surface, resulting in the formation of distinct clusters. Atom probe tomography further validates the Ga distributions in Al 2 O 3 and ZnO nanoprobes. Complementary Monte Carlo simulations with the transport of ions in the matter program indicated that the introduction of Ga + prompts the generation of cation and anion vacancies, an occurrence more pronounced in Al 2 O 3 compared to ZnO. In conclusion, this study not only enriches the knowledge of ion-matter interactions, but also serves as a practical guide for the fabrication of nanoscale functionalized AFM probes.

Al2O3↗

Uncovering the three-dimensional structure of upconverting core–shell nanoparticles with multislice electron ptychography

In photon upconverting core–shell nanoparticles, structure strongly dictates performance. Typical imaging in scanning transmission electron microscopy has sufficient resolution to probe the atomic structure of these nanoparticles, but contrast, dose, and projection limitations make conventional methods insufficient for fully characterizing these structures. Phase retrieval techniques provide a promising alternative imaging mode, and, in particular, multislice electron ptychography can recover depth-dependent information. Here, we study beam-sensitive photon upconverting core–shell nanoparticles with a multislice ptychography approach using a low electron dose to avoid damage. Large strain fields arise in these heterostructures due to the mismatch in lattice parameter between the core and the shell. We reconstruct both a nanoparticle that appears defect-free and one that has a large break in the side and map the distribution of strain in 3D by computing distortion fields from high-resolution potential images of each slice. In the defect-free nanoparticle, we observe twisting of the shell, while in the broken nanoparticle, we measure the 3D position of the crack, the core, and dislocations. These results highlight the advantage of multislice electron ptychography to recover 3D information from a single scan, even under strict electron dose requirements from beam-sensitive samples.

74 ATOMIC AND MOLECULAR PHYSICS↗

Atomic Structural Features of Stacking Faults and Domain Connections in the Li- and Mn-Rich Cathode

Li- and Mn-rich layered oxides (LMRs), a class of earth-abundant materials for rechargeable Li-ion battery cathodes, crystallize into layered structures of two different symmetries: C2/m represented by Li 2 MnO 3 and R$\overline{3}$m represented by LiMn 0.5 Ni 0.5 O 2 . Fundamental questions about how the C2/m and R$\overline{3}$m domains spatially correlate within the same oxide grain and how the C2/m stacking faults arrange themselves when this happens still remain. Here, by using integrated differential phase contrast imaging in scanning transmission electron microscopy (STEM-iDPC), we probe the structural and compositional details of a prototypical, cobalt-free LMR material, 0.3Li 2 MnO 3 •0.7LiMn 0.5 Ni 0.5 O 2 (Li 1.13 Mn 0.57 Ni 0.3 O 2 ). The connection between the C2/m and R$\overline{3}$m domains is found to be abrupt, facilitated by the small lattice mismatch between the two structures. Stacking faults in the C2/m domains feature atomic plane shifting that accommodates stacking sequence changes, which explains why the stacking faults form in a random manner. Furthermore, a local disordering mechanism was identified to correlate with the C2/m stacking faults. Chemically, it is found that Ni coexists with Mn at the transition metal sites within the nominal Li 2 MnO 3 domain. As a result, this study demonstrates that STEM-iDPC is a very useful tool for capturing all the elements in a single image, revealing atomic details on domain connections and stacking faults in the LMRs.

Li-rich and Mn-rich oxides↗

Ultrafast nano-imaging and nano-spectroscopy

Ultrafast pump–probe nano-imaging combines scanning probe-based optical near-field microscopy with ultrafast spectroscopy to enable imaging with deep sub-wavelength spatial resolution, femtosecond temporal resolution and simultaneous spectral resolution. Ultrafast nano-imaging has gained increased attention for its ability to provide far-from-equilibrium excitation and excited-state contrast. With coherent and nonlinear probing, coupled electron, spin and lattice dynamics on elementary timescale and length scale can be resolved. Through nano-movies, ultrafast nano-imaging visualizes correlated quantum dynamics underlying the properties of solid-state materials, semiconductors, molecular electronic, photonic, photovoltaic and other functional materials. With nanometre spatial resolution, this method probes elementary dynamic processes across multiple length scales that are otherwise obscured in conventional ultrafast spectroscopy in which heterogeneities are spatially averaged. Furthermore, this Primer describes the theoretical background and experimental implementation of ultrafast nano-imaging; signal interpretation and modelling; representative examples and a perspective for the future development of the field.

Microscopy↗

Terahertz magneto-nanoscopy of encapsulated monolayer graphene

This study investigates the nanoscale conductivity of encapsulated monolayer graphene at temperatures down to 5 K and magnetic fields of up to 1 T. We use the scattering-type scanning near-field optical microscopy technique to probe magnetic-field-dependent responses from graphene close to charge neutrality in the terahertz spectral region. We observe the near-perfect high-q reflector behavior of graphene but with subtle changes by the presence of magnetic fields. Measurements align with calculations of the magneto-optical conductivity and the near-field spectroscopic contrast that describes the field-tunable cyclotron resonance of Dirac fermions. Our result provides an initial step toward understanding temperature and magnetic field effects on nanoscale terahertz transport in two-dimensional quantum materials.

Kim, Richard H. J. [Ames Laboratory (AMES), Ames, ↗

In Situ Liquid Electron Microscope Cells Strongly Attenuate Electrochemical Behavior

In situ electrochemical Scanning Transmission Electron Microscopy (ec-S/TEM) probes the dynamics of electrochemical processes in real time and at high spatial resolution. This method utilizes microfabricated electrochemical cells, with enclosed dimensions of 800 μm wide, 800 μm long, and 1–2 μm tall, with electron-transparent silicon nitride windows. Working, counter, and reference electrodes in the configuration studied are deposited Pt with a planar surface area of about 1 μm 2 and a height of 50 nm. The cell confines the electrolyte within a 1 μm tall channel, and the microfabricated electrodes have a non-standard geometry, are coplanar, and are not front-facing. As such, standard assumptions of electrochemical experiments do not apply. COMSOL modeling was used to compare and contrast differences in electrochemical behavior between conventional experimental setups and the in situ ec-S/TEM cells. Cell height strongly affected voltammogram measurements: peak magnitudes and shifts correlate directly to cell height. Reactant concentration above the electrode quickly decreases during deposition, leading to a planar diffusion-dominated regime. The concentration gradient prioritizes particle growth along the thin edges of the electrode and not on the planar part of the electrode. Experiments done in the ec-S/TEM ex situ of a TEM verify the model’s accuracy.

Wittman, Reed M. [Oak Ridge National Laboratory (O↗

Uncovering multiscale structure-property correlations via active learning in scanning tunneling microscopy

Atomic arrangements and local sub-structures fundamentally influence emergent material functionalities. These structures are conventionally probed using spatially resolved studies and the property correlations are deciphered by a researcher based on sequential explorations, thereby limiting the efficiency and scope. Here we demonstrate a multi-scale Bayesian deep-learning based framework that automatically correlates material structure with its electronic properties using scanning tunneling microscopy (STM) measurements in real-time. Its predictions are used to autonomously direct exploration toward regions of the sample that optimize a given material property. This method is deployed on a low-temperature ultra-high vacuum STM to understand the structure-property relationship in a europium-based semimetal, EuZn 2 As 2 , a promising candidate relevant to magnetism-driven topological phenomena. The framework employs a sparse-sampling approach to efficiently construct the scalar-property space using minimal measurements, about 1–10% of the data required in standard hyperspectral methods. Moreover, we formulate the problem hierarchically across length scales, implementing autonomous workflow to locate mesoscopic and atomic structures that correspond to a target material property. This framework offers the choice to design scalar-property from the spectroscopic data to steer sample exploration. Our findings reveal correlations of the electronic properties unique to surface terminations, local defect density, and point defects.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Fingerprints of composite fermion Lambda levels in scanning tunneling microscopy

A composite fermion (CF) is a topological quasiparticle that emerges from a nonperturbative attachment of vortices to electrons in strongly correlated two-dimensional materials. Similar to noninteracting fermions that form Landau levels in a magnetic field, CFs can fill analogous “Lambda” levels, giving rise to the fractional quantum Hall (FQH) effect of electrons. Here, we show that Lambda levels can be directly visualized through the characteristic peak structure in the signal obtained via spectroscopy with scanning tunneling microscopy (STM) on a FQH state. Complementary to transport, which probes the low-energy properties of CFs, we show that high-energy features in STM spectra can be interpreted in terms of Lambda levels. We numerically demonstrate that STM spectra can be accurately modeled using Jain's CF theory. Our results show that STM provides a powerful tool for revealing the anatomy of FQH states and identifying physics beyond the noninteracting CF paradigm.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Microstructure, electrical resistivity, and tensile properties of neutron-irradiated Cu–Cr–Nb–Zr

High strength, high conductivity copper alloys that can resist creep at high temperatures are one of the primary candidates for efficient heat exchangers in fusion reactors. Cu–Cr–Nb–Zr (CCNZ) alloys, which were designed to improve the strength and creep life of ITER Cu–Cr–Zr (CCZ) reference alloys, have been found to have comparable electrical conductivity and tensile properties to CCZ alloys. The measured creep rupture times for these improved alloys is about ten times higher than the ITER reference alloys at 90–125 MPa at 500 °C. However, the effects of neutron irradiation on these alloys, and the ensuing material properties, have not been studied; thus, their utility in a fusion reactor environment is not well understood. This study characterizes the room temperature mechanical and electrical properties of a neutron-irradiated CCNZ alloy and compares them to a neutron-irradiated ITER reference heat sink CCZ alloy. Tensile specimens were neutron irradiated in the High Flux Isotope Reactor (HFIR) to 5 dpa between 250 °C and 325 °C. Post-irradiation characterization included electrical resistivity measurements, hardness, and tensile tests. Microstructural evaluation used scanning electron microscopy, energy dispersive x-ray spectroscopy, and atom probe tomography to characterize the irradiation-produced changes in the microstructure and investigate the mechanistic processes leading to post-irradiation properties. Transmutation calculations were validated with composition measurements from atom probe data and used to calculate contributions to the increased electrical resistivity measured after irradiation. Comparisons with CCZ alloys in the same irradiation heat found that the post-irradiated CCNZ and CCZ alloys had comparable electrical resistivity. Although CCNZ alloys suffered more irradiation hardening than CCZ, the overall tensile behavior deviated very little from non-irradiated values in the temperature range studied.

36 MATERIALS SCIENCE↗

Formation of uranium nitride nanoparticles via mechanical alloying of uranium-molybdenum alloy fuels in gaseous nitrogen

Uranium-molybdenum (U-Mo) alloys show promise as a nuclear fuel system due to their high thermal conductivity and fuel loading capability. However, U-Mo systems are susceptible to irradiation induced swelling ultimately affecting the cladding via mechanical and chemical interactions. To address these shortcomings, this research investigated the formation of uranium mononitride (UN) nanoparticles within a 90 wt% U/10 wt% Mo (U-10Mo) matrix to act as a prospective defect sink for fission products at nanometric hetero-interfaces. To promote the formation of UN, U-10Mo powders were mechanically alloyed under a high purity nitrogen atmosphere. Variations of the milling process investigated included media size, duration of milling, and number of times the milling jar was re-aerated with nitrogen gas. Characterization of the fuel microstructure was completed using light element analysis, X-ray diffraction, scanning and transmission-electron microscopy, electron energy loss spectroscopy, and atom probe tomography. UN nanoparticles measuring 1–5 nm in radius were observed in the U-Mo matrix as early as 1 h into the mechanical alloying process. Milling time in excess of 10 h was found to lead to deleterious effects induced by the stainless-steel milling media.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High spatial resolution charge sensing of quantum Hall states

Charge distribution offers a unique fingerprint of important properties of electronic systems, including dielectric response, charge ordering, and charge fractionalization. Here, we develop an architecture for charge sensing in two-dimensional electronic systems in a strong magnetic field. We probe local change of the chemical potential in a proximitized detector layer using scanning tunneling microscopy, allowing us to infer the chemical potential and the charge profile in the sample. Our technique has both high energy (<0.3 meV) and spatial (<10 nm) resolution exceeding that of previous studies by an order of magnitude. We apply our technique to study the chemical potential of quantum Hall liquids in monolayer graphene under high magnetic fields and their responses to charge impurities. The chemical potential measurement provides a local probe of the thermodynamic gap of quantum Hall ferromagnets and fractional quantum Hall states. The screening charge profile reveals spatially oscillatory response of the quantum Hall liquids to charge impurities and is consistent with the composite Fermi liquid picture close to the half-filling. Our technique also paves the way to map moiré potentials, probe Wigner crystals, and investigate fractional charges in quantum Hall and Chern insulators.

charge sensing↗

Understanding the structural and morphological effects of synthesis route on NpO 2

The availability of actinide standard materials for use in nuclear safeguard applications is critical, as is thorough characterization thereof. Although accurate trace element compositions and isotopic considerations are paramount for deployment of reference standards, structural characterization is also essential towards accurately describing the chemical form and potential matrix effects in candidate materials. Here, to this end, samples of NpO 2 were synthesized via a direct denitration (DD) method and probed with powder X-ray diffraction (PXRD), Raman spectroscopy, and scanning electron microscopy (SEM) for structural and morphological characterization and comparison with NpO 2 materials produced via modified direct denitration (MDD). PXRD confirmed the bulk identity of NpO 2 , and no additional phases were identified using this method. Analysis of Raman data collected using a 532 nm excitation wavelength indicates that samples are mostly phase pure; however, some variability in spectral features is observed. Analysis of additional spectroscopic data collected with a 785 nm excitation wavelength revealed variability in the relative intensity of spectral features. Raman spectroscopy indicates that the sample is primarily NpO 2 ; however, additional signals indicate possible structural disorder, oxidized species, or potential contributions from other Np phases. To further investigate the possibility of additional phase contributions within the sample of NpO 2 , Raman spectroscopic mapping was employed to examine the homogeneity of the sample produced via DD. From this analysis, we determined that despite variability in the intensity of Raman-active vibrational modes, consistent spectra are obtained throughout the area of the sample investigated. SEM images show aggregates with variable sizes and shapes, with rounded, primary particles possessing an average diameter of approximately 100 nm. Comparison of the results of these multimodal analyses to the literature indicates that the crystal chemical, spectroscopic, and microstructural properties of NpO 2 vary based on synthesis method, even if X-ray diffraction data indicate that the bulk phase is NpO 2 .

Direct denitration↗

Single-particle detection of enhanced polarizability in Au-decorated semiconducting nanorods via scanning dielectric microscopy

Hybrid nanostructures that combine semiconducting and metallic components offer great potential for photothermal therapy, optoelectronics, and sensing, by integrating tunable optical properties with enhanced light absorption and charge transport. Boosting the integrated performance of these hybrid systems demands techniques capable of probing local variations of the physical properties inaccessible to bulk analysis. Here, we report the single-particle dielectric characterization of hybrid, semiconducting bismuth sulfide (Bi 2 S 3 ) nanorods (NR) decorated with metallic Au nanoparticles (NP), employing scanning dielectric microscopy, which uses electrostatic force microscopy in combination with finite-element numerical simulations. We reveal a pronounced enhancement in the local dielectric response of Bi2S3 upon Au decoration, attributed to interfacial polarization and electron transfer from Au to the Bi 2 S 3 matrix, thus suggesting a enhanced metallic-like polarizability at the single-particle level. Numerical simulations show that the response is dominated by the vertical component of the permittivity and that the decorating metallic Au NP produce only moderate shielding of the semiconductor Bi 2 S 3 NR core, indicating that the large increase in the dielectric response originates primarily from intrinsic modifications within the NR. Overall, these findings provide direct insight into structure–property relationships at the single-particle level, supporting the rational design of advanced hybrid nanostructures with tailored electronic functionalities.

36 MATERIALS SCIENCE↗

High‐speed 4‐dimensional scanning transmission electron microscopy using compressive sensing techniques

Abstract Here we show that compressive sensing allows 4‐dimensional (4‐D) STEM data to be obtained and accurately reconstructed with both high‐speed and reduced electron fluence. The methodology needed to achieve these results compared to conventional 4‐D approaches requires only that a random subset of probe locations is acquired from the typical regular scanning grid, which immediately generates both higher speed and the lower fluence experimentally. We also consider downsampling of the detector, showing that oversampling is inherent within convergent beam electron diffraction (CBED) patterns and that detector downsampling does not reduce precision but allows faster experimental data acquisition. Analysis of an experimental atomic resolution yttrium silicide dataset shows that it is possible to recover over 25 dB peak signal‐to‐noise ratio in the recovered phase using 0.3% of the total data. Lay abstract : Four‐dimensional scanning transmission electron microscopy (4‐D STEM) is a powerful technique for characterizing complex nanoscale structures. In this method, a convergent beam electron diffraction pattern (CBED) is acquired at each probe location during the scan of the sample. This means that a 2‐dimensional signal is acquired at each 2‐D probe location, equating to a 4‐D dataset. Despite the recent development of fast direct electron detectors, some capable of 100kHz frame rates, the limiting factor for 4‐D STEM is acquisition times in the majority of cases, where cameras will typically operate on the order of 2kHz. This means that a raster scan containing 256^2 probe locations can take on the order of 30s, approximately 100‐1000 times longer than a conventional STEM imaging technique using monolithic radial detectors. As a result, 4‐D STEM acquisitions can be subject to adverse effects such as drift, beam damage, and sample contamination. Recent advances in computational imaging techniques for STEM have allowed for faster acquisition speeds by way of acquiring only a random subset of probe locations from the field of view. By doing this, the acquisition time is significantly reduced, in some cases by a factor of 10‐100 times. The acquired data is then processed to fill‐in or inpaint the missing data, taking advantage of the inherently low‐complex signals which can be linearly combined to recover the information. In this work, similar methods are demonstrated for the acquisition of 4‐D STEM data, where only a random subset of CBED patterns are acquired over the raster scan. We simulate the compressive sensing acquisition method for 4‐D STEM and present our findings for a variety of analysis techniques such as ptychography and differential phase contrast. Our results show that acquisition times can be significantly reduced on the order of 100‐300 times, therefore improving existing frame rates, as well as further reducing the electron fluence beyond just using a faster camera.

Robinson, Alex W.↗

On-demand nanoengineering of in-plane ferroelectric topologies

Hierarchical assemblies of ferroelectric nanodomains, so-called super-domains, can exhibit exotic morphologies that lead to distinct behaviours. Controlling these super-domains reliably is critical for realizing states with desired functional properties. Here we reveal the super-switching mechanism by using a biased atomic force microscopy tip, that is, the switching of the in-plane super-domains, of a model ferroelectric Pb 0.6 Sr 0.4 TiO 3 . We demonstrate that the writing process is dominated by a super-domain nucleation and stabilization process. A complex scanning-probe trajectory enables on-demand formation of intricate centre-divergent, centre-convergent and flux-closure polar structures. Correlative piezoresponse force microscopy and optical spectroscopy confirm the topological nature and tunability of the emergent structures. The precise and versatile nanolithography in a ferroic material and the stability of the generated structures, also validated by phase-field modelling, suggests potential for reliable multi-state nanodevice architectures and, thereby, an alternative route for the creation of tunable topological structures for applications in neuromorphic circuits.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Impacts of A‐Site Composition on the Cation Dissolution‐Mediated Surface Restructuring of Layered Nickelate Oxide Electrocatalysts During Alkaline Oxygen Evolution Reaction

The oxygen evolution reaction (OER) is a key anodic counter‐reaction for electrochemical production of fuels and chemicals. It is hindered by sluggish four‐electron transfer kinetics requiring highly oxidative operating potentials to achieve commercially relevant rates. NiFeO x H y electrocatalysts are among the most promising for OER in alkaline electrolytes. The Ni(OH) 2 /NiOOH redox couple has been reported as the active phase in Ni‐based electrocatalysts; however, its activity is often hindered by deactivation arising from the formation of OER‐inactive insulating species. Limited strategies exist for mitigating this deactivation. This study aims to address this by interrogating the evolution of OER active sites as a function of precatalyst composition and structural properties using a series of layered, crystalline Ni‐based Ruddlesden–Popper (RP) oxides (A 2 NiO 4+δ ). In situ evolution of the active NiO x H y surface is probed through Ni‐site OER turnover frequency analysis, and electrochemical impedance spectroscopy coupled with scanning transmission electron microscopy. We show that the stability of layered nickelate oxide electrocatalysts is governed by the dynamic competition between cation dissolution and Ni‐site reversibility, which can be tuned through the A‐site composition of RP oxides. These findings yield insights toward engineering OER oxide precatalysts that optimize the stability of in situ‐generated OER active phases.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Atomic resolution scanning transmission electron microscopy at liquid helium temperatures for quantum materials

Fundamental quantum phenomena in condensed matter, ranging from correlated electron systems to quantum information processors, manifest their emergent characteristics and behaviors predominantly at low temperatures. This necessitates the use of liquid helium (LHe) cooling for experimental observation. Atomic resolution scanning transmission electron microscopy combined with LHe cooling (cryo-STEM) provides a powerful characterization technique to probe local atomic structural modulations and their coupling with charge, spin and orbital degrees-of-freedom in quantum materials. However, achieving atomic resolution in cryo-STEM is exceptionally challenging, primarily due to sample drifts arising from temperature changes and noises associated with LHe bubbling, turbulent gas flow, etc. In this work, we demonstrate atomic resolution cryo-STEM imaging at LHe temperatures using a commercial side-entry LHe cooling holder. Firstly, we examine STEM imaging performance as a function of He gas flow rate, identifying two primary noise sources: He-gas pulsing and He-gas bubbling. Secondly, we propose two strategies to achieve low noise conditions for atomic resolution STEM imaging: either by temporarily suppressing He gas flow rate using the needle valve or by acquiring images during the natural warming process. Lastly, we show the applications of image acquisition methods and image processing techniques in investigating structural phase transitions in Cr 2 Ge 2 Te 6 , CuIr 2 S 4 , and CrCl 3 . In conclusion, our findings represent an advance in the field of atomic resolution electron microscopy imaging for quantum materials and devices at LHe temperatures, which can be applied to other commercial side-entry LHe cooling TEM holders.

36 MATERIALS SCIENCE↗

Experimental study of energy-dependent angular broadening of MeV electron beams for high-resolution imaging in thick samples

In scanning transmission electron microscopy (STEM), spatial resolution is primarily influenced by the projected size of the electron probe within the specimen. In thin samples, a large semi-convergence angle enables a tightly focused beam and sub-nanometer resolution. However, in thick specimens, resolution is fundamentally limited by transverse beam broadening from multiple large-angle scattering events—for example, a probe with 10 mrad angular divergence can broaden by ∼100 nm over a 10 μm path. Since this broadening scales inversely with beam energy, MeV-STEM offers a promising route for high-resolution imaging in thick materials. To quantitatively assess this effect, we performed high-precision measurements at UCLA’s PEGASUS beamline, characterizing beam divergence and intensity profiles for 3–8 MeV electrons transmitted through a wedged-silicon sample of varying thickness. Our results reconcile discrepancies among analytical models and validate Monte Carlo simulations. Here, we find that increasing beam energy from 3.0 to 5.8 MeV reduces angular broadening by a factor of 2.6, with diminishing returns observed at 7.6 MeV. These findings provide a quantitative framework for optimizing MeV-STEM parameters in high-resolution imaging of thick biological and microelectronic specimens, and for guiding beam energy selection in other advanced imaging modes beyond STEM.

36 MATERIALS SCIENCE↗