Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “scanning mode”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Maia Mapper: high definition XRF imaging in the lab

Here, Maia Mapper is a laboratory μXRF mapping system for efficient elemental imaging of drill core sections serving minerals research and industrial applications. It targets intermediate spatial scales, with imaging of up to ~80 M pixels over a 500×150 mm 2 sample area. It brings together (i) the Maia detector and imaging system, with its large solid-angle, event-mode operation, millisecond pixel transit times in fly-scan mode and real-time spectral deconvolution and imaging, (ii) the high brightness MetalJet D2 liquid metal micro-focus X-ray source from Excillum, and (iii) an efficient XOS polycapillary lens with a flux gain ~15,900 at 21 keV into a ~32 μm focus, and (iv) a sample scanning stage engineered for standard drill-core sections. Count-rates up to ~3 M/s are observed on drill core samples with low dead-time up to ~1.5%. Automated scans are executed in sequence with display of deconvoluted element component images accumulated in real-time in the Maia detector. Application images on drill core and polished rock slabs illustrate Maia Mapper capabilities as part of the analytical workflow of the Advanced Resource Characterisation Facility, which spans spatial dimensions from ore deposit to atomic scales.

47 OTHER INSTRUMENTATION↗

High-Resolution Scanning Coded-Mask-Based X-ray Multi-Contrast Imaging and Tomography

Near-field X-ray speckle tracking has been used in phase-contrast imaging and tomography as an emerging technique, providing higher contrast images than traditional absorption radiography. Most reported methods use sandpaper or membrane filters as speckle generators and digital image cross-correlation for phase reconstruction, which has either limited resolution or requires a large number of position scanning steps. Recently, we have proposed a novel coded-mask-based multi-contrast imaging (CMMI) technique for single-shot measurement with superior performance in efficiency and resolution compared with other single-shot methods. We present here a scanning CMMI method for the ultimate imaging resolution and phase sensitivity by using a coded mask as a high-contrast speckle generator, the flexible scanning mode, the adaption of advanced maximum-likelihood optimization to scanning data, and the multi-resolution analysis. Scanning CMMI can outperform other speckle-based imaging methods, such as X-ray speckle vector tracking, providing higher quality absorption, phase, and dark-field images with fewer scanning steps. Scanning CMMI is also successfully demonstrated in multi-contrast tomography, showing great potentials in high-resolution full-field imaging applications, such as in vivo biomedical imaging.

Qiao, Zhi (ORCID:0000000233928732)↗

Rocket spectrometer for investigation of the far ultraviolet solar spectrum

A rocket-borne Ebert spectrometer and telescope were used for analysis of the solar spectrum. The instrument was arranged in the high resolution line scanning mode. Selected emission lines between 1170 and 1640 A were scanned, and a complete wavelength scan was made from 1170 A to 1850 A. Accurate measurements were made of the line profiles of the He II lines at 1640 A, C IV lines at 1550 A, Si IV lines at 1400 A, C II lines at 1335 A, the N V lines at 1240 A, and the C III lines at 1175 A. Accurate intensity measurements of the quiet sun spectrum for wavelengths between 1174 A and 3220 A were obtained. Spectral resolution was better than 0.03 A over most of the range and spatial resolution was relatively low so that the observations are averaged over the chromospheric network. Plots of absolute intensity versus wave length were prepared for the full wavelength range of the observations.

Parkinson, W. H.↗

Rapid Scan-Humidified Growth Cloud Condensation Nuclei Instrument

This research focused on enhancements to the streamwise thermal gradient cloud condensation nuclei counter to support the rapid scan mode and to enhance the capability for aerosol humidified growth measurements. The research identified the needs for flow system modifications and range of capability for operating the conventional instrument in the rapid scan and humidified growth modes.

47 OTHER INSTRUMENTATION↗

A four-lidar view of Cirrus from the FIRE IFO: 27-28 October 1986

The four ground-based lidar systems that participated in the 1986 FIRE IFO were configured in a diamond-shaped array across central and southern Wisconsin. Data were generally collected in the zenith pointing mode, except for the Doppler lidar, which regularly operated in a scanning mode with intermittent zenith observations. As a component of the cirrus case study of 27 and 28 October 1986 selected for initial analysis, data collected by the remote sensor ensemble from 1600 (on the 27th) to 2400 UTC (on the 28th) is described and compared. In general, the cirrus studied on the 27th consisted of intermittent layers of thin and subvisual cirrus clouds. Particularly at Wausau, subvisual cirrus was detected from 11.0 to 11.5 km MSL, just below the tropopause. At lower levels, occasional cirrus clouds between approx. 8.0 to 9.5 km were detected from all ground sites. Preliminary analysis of the four-lidar dataset reveals the passage of surprisingly consistent cloud features across the experiment area. A variety of types and amounts of middle and high level clouds occurred, ranging from subvisual cirrus to deep cloud bands. It is expected that the ground-based lidar measurements from this case study, as well as the airborne observations, will provide an excellent data base for comparison to satellite observations.

Sassen, Kenneth↗

Evaluation of Deep Learning Model Architectures for Point-of-Care Ultrasound Diagnostics

Point-of-care ultrasound imaging is a critical tool for patient triage during trauma for diagnosing injuries and prioritizing limited medical evacuation resources. Specifically, an eFAST exam evaluates if there are free fluids in the chest or abdomen but this is only possible if ultrasound scans can be accurately interpreted, a challenge in the pre-hospital setting. In this effort, we evaluated the use of artificial intelligent eFAST image interpretation models. Widely used deep learning model architectures were evaluated as well as Bayesian models optimized for six different diagnostic models: pneumothorax (i) B- or (ii) M-mode, hemothorax (iii) B- or (iv) M-mode, (v) pelvic or bladder abdominal hemorrhage and (vi) right upper quadrant abdominal hemorrhage. Models were trained using images captured in 27 swine. Using a leave-one-subject-out training approach, the MobileNetV2 and DarkNet53 models surpassed 85% accuracy for each M-mode scan site. The different B-mode models performed worse with accuracies between 68% and 74% except for the pelvic hemorrhage model, which only reached 62% accuracy for all model architectures. These results highlight which eFAST scan sites can be easily automated with image interpretation models, while other scan sites, such as the bladder hemorrhage model, will require more robust model development or data augmentation to improve performance. With these additional improvements, the skill threshold for ultrasound-based triage can be reduced, thus expanding its utility in the pre-hospital setting.

47 OTHER INSTRUMENTATION↗

An interchangeable scanning Hall probe/scanning SQUID microscope

We have constructed a scanning probe microscope for magnetic imaging, which can function as a scanning Hall probe microscope (SHPM) and as a scanning SQUID microscope (SSM). The scanning scheme, applicable to SHPM and SSM, consists of a mechanical positioning (sub) micron-XY stage and a flexible direct contact to the sample without a feedback control system for the Z-axis. With the interchangeable capability of operating two distinct scanning modes, our microscope can incorporate the advantageous functionalities of the SHPM and SSM with large scan range up to millimeter, high spatial resolution (⩽4 μm), and high field sensitivity in a wide range of temperature (4.2 K-300 K) and magnetic field (10{sup −7} T-1 T). To demonstrate the capabilities of the system, we present magnetic images scanned with SHPM and SSM, including a RbFeB magnet and a nickel grid pattern at room temperature, surface magnetic domain structures of a La{sub 2/3}Ca{sub 1/3}MnO{sub 3} thin film at 77 K, and superconducting vortices in a striped niobium film at 4.2 K.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analytical equations for CT dose profiles derived using a scatter kernel of Monte Carlo parentage with broad applicability to CT dosimetry problems

Purpose: Knowledge of the complete axial dose profile f(z), including its long scatter tails, provides the most complete (and flexible) description of the accumulated dose in CT scanning. The CTDI paradigm (including CTDI{sub vol}) requires shift-invariance along z (identical dose profiles spaced at equal intervals), and is therefore inapplicable to many of the new and complex shift-variant scan protocols, e.g., high dose perfusion studies using variable (or zero) pitch. In this work, a convolution-based beam model developed by Dixon et al.[Med. Phys. 32, 3712-3728, (2005)] updated with a scatter LSF kernel (or DSF) derived from a Monte Carlo simulation by Boone [Med. Phys. 36, 4547-4554 (2009)] is used to create an analytical equation for the axial dose profile f(z) in a cylindrical phantom. Using f(z), equations are derived which provide the analytical description of conventional (axial and helical) dose, demonstrating its physical underpinnings; and likewise for the peak axial dose f(0) appropriate to stationary phantom cone beam CT, (SCBCT). The methodology can also be applied to dose calculations in shift-variant scan protocols. This paper is an extension of our recent work Dixon and Boone [Med. Phys. 37, 2703-2718 (2010)], which dealt only with the properties of the peak dose f(0), its relationship to CTDI, and its appropriateness to SCBCT. Methods: The experimental beam profile data f(z) of Mori et al.[Med. Phys. 32, 1061-1069 (2005)] from a 256 channel prototype cone beam scanner for beam widths (apertures) ranging from a = 28 to 138 mm are used to corroborate the theoretical axial profiles in a 32 cm PMMA body phantom. Results: The theoretical functions f(z) closely-matched the central axis experimental profile data{sup 11} for all apertures (a = 28 -138 mm). Integration of f(z) likewise yields analytical equations for all the (CTDI-based) dosimetric quantities of conventional CT (including CTDI{sub L} itself) in addition to the peak dose f(0) relevant to SCBCT (allowing direct cross-comparison between CT scan modes and mathematical proofs of several hypotheses of practical utility in CT dosimetry). A fast, analytical dose simulator{sup 6} is also demonstrated--successfully matching complex dose distributions measured using OSL and film dosimetry. Conclusions: The model described allows one to obtain analytical functions describing both the primary and scatter components of the axial dose profile. This model (using no empirical functions or adjustable fit parameters) provides a good match to the experimental data, as well as a complete analytical description of dose for both conventional (axial and helical) CT and cone beam CT. An efficient method whereby the complete data set for both modalities can be obtained from a single measurement of either CTDI{sub 100} or f(0) is illustrated. This method is also flexible--allowing calculation of heretofore unattainable doses for recently-introduced shift-variant protocols [e.g., variable pitch (irregular scan spacing), variable aperture, shuttle mode acquisition, and mA modulation schemes].

61 RADIATION PROTECTION AND DOSIMETRY↗

A CATALOG OF LOW-MASS STAR-FORMING CORES OBSERVED WITH SHARC-II AT 350 μ m

We present a catalog of low-mass dense cores observed with the SHARC-II instrument at 350 μ m. Our observations have an effective angular resolution of 10″, approximately 2.5 times higher than observations at the same wavelength obtained with the Herschel Space Observatory , albeit with lower sensitivity, especially to extended emission. The catalog includes 81 maps covering a total of 164 detected sources. For each detected source, we tabulate basic source properties including position, peak intensity, flux density in fixed apertures, and radius. We examine the uncertainties in the pointing model applied to all SHARC-II data and conservatively find that the model corrections are good to within ∼3″, approximately 1/3 of the SHARC-II beam. We examine the differences between two array scan modes and find that the instrument calibration, beam size, and beam shape are similar between the two modes. We also show that the same flux densities are measured when sources are observed in the two different modes, indicating that there are no systematic effects introduced into our catalog by utilizing two different scan patterns during the course of taking observations. We find a detection rate of 95% for protostellar cores but only 45% for starless cores, and demonstrate the existence of a SHARC-II detection bias against all but the most massive and compact starless cores. Finally, we discuss the improvements in protostellar classification enabled by these 350 μ m observations.

79 ASTRONOMY AND ASTROPHYSICS↗

A function space approach to state and model error estimation for elliptic systems

An approach is advanced for the concurrent estimation of the state and of the model errors of a system described by elliptic equations. The estimates are obtained by a deterministic least-squares approach that seeks to minimize a quadratic functional of the model errors, or equivalently, to find the vector of smallest norm subject to linear constraints in a suitably defined function space. The minimum norm solution can be obtained by solving either a Fredholm integral equation of the second kind for the case with continuously distributed data or a related matrix equation for the problem with discretely located measurements. Solution of either one of these equations is obtained in a batch-processing mode in which all of the data is processed simultaneously or, in certain restricted geometries, in a spatially scanning mode in which the data is processed recursively. After the methods for computation of the optimal estimates are developed, an analysis of the second-order statistics of the estimates and of the corresponding estimation error is conducted. Based on this analysis, explicit expressions for the mean-square estimation error associated with both the state and model error estimates are then developed.

Rodriguez, G.↗

A function space approach to state and model error estimation for elliptic systems

An approach is advanced for the concurrent estimation of the state and of the model errors of a system described by elliptic equations. The estimates are obtained by a deterministic least-squares approach that seeks to minimize a quadratic functional of the model errors, or equivalently, to find the vector of smallest norm subject to linear constraints in a suitably defined function space. The minimum norm solution can be obtained by solving either a Fredholm integral equation of the second kind for the case with continuously distributed data or a related matrix equation for the problem with discretely located measurements. Solution of either one of these equations is obtained in a batch-processing mode in which all of the data is processed simultaneously or, in certain restricted geometries, in a spatially scanning mode in which the data is processed recursively. After the methods for computation of the optimal esimates are developed, an analysis of the second-order statistics of the estimates and of the corresponding estimation error is conducted. Based on this analysis, explicit expressions for the mean-square estimation error associated with both the state and model error estimates are then developed. While this paper focuses on theoretical developments, applications arising in the area of large structure static shape determination are contained in a closely related paper (Rodriguez and Scheid, 1982).

Rodriguez, G.↗

The EXIST Mission Concept Study

EXIST is a mission designed to find and study black holes (BHs) over a wide range of environments and masses, including: 1) BHs accreting from binary companions or dense molecular clouds throughout our Galaxy and the Local Group, 2) supermassive black holes (SMBHs) lying dormant in galaxies that reveal their existence by disrupting passing stars, and 3) SMBHs that are hidden from our view at lower energies due to obscuration by the gas that they accrete. 4) the birth of stellar mass BHs which is accompanied by long cosmic gamma-ray bursts (GRBs) which are seen several times a day and may be associated with the earliest stars to form in the Universe. EXIST will provide an order of magnitude increase in sensitivity and angular resolution as well as greater spectral resolution and bandwidth compared with earlier hard X-ray survey telescopes. With an onboard optical-infra red (IR) telescope, EXIST will measure the spectra and redshifts of GRBs and their utility as cosmological probes of the highest z universe and epoch of reionization. The mission would retain its primary goal of being the Black Hole Finder Probe in the Beyond Einstein Program. However, the new design for EXIST proposed to be studied here represents a significant advance from its previous incarnation as presented to BEPAC. The mission is now less than half the total mass, would be launched on the smallest EELV available (Atlas V-401) for a Medium Class mission, and most importantly includes a two-telescope complement that is ideally suited for the study of both obscured and very distant BHs. EXIST retains its very wide field hard X-ray imaging High Energy Telescope (HET) as the primary instrument, now with improved angular and spectral resolution, and in a more compact payload that allows occasional rapid slews for immediate optical/IR imaging and spectra of GRBs and AGN as well as enhanced hard X-ray spectra and timing with pointed observations. The mission would conduct a 2 year full sky survey in scanning mode, interrupted for several orbits per day by GRB follow-ups, followed by a combined pointing-scanning mission phase for optical/IR spectroscopy and redshifts for the large AGN sample found in the survey as well as GRBs and LSST transients. A Team of university, NASA, and industry investigators will conduct the study to determine the full sensitivity and capabilities of this new configuration for EXIST. It will build on the extensive studies of the prior design for the mission and the HET and will incorporate the optical/IR telescope (hereafter IRT) now fully developed by our ITT partner for the NextView Commercial Remote Sensing mission (early 2008 launch) with a focal plane to be developed at GSFC based in part on JWST/NIRSPEC designs. No new technology is needed for either the IRT or HET instruments. The study will pay close attention to full mission cost and present a design for the Decadal Survey Workshop to ensure this even more capable EXIST mission is once again part of the next Decadal Survey.

Fishman, Gerald J.↗

HEAO-A nominal scanning observation schedule

The HEAO-A observatory, scheduled for launch in late June 1977, will spend most of its orbital lifetime in a scanning mode, spining from 0.03 to 0.1 rpm about an axis aligned with the sun. The dates of availability in the scan band are given for a list of 248 X-ray sources. Celestial maps of source locations and scan planes, and examples of the nighttime elevation of available sources are presented. This document is intended to aid ground-based observers in planning coordinated observations with HEAO-A.

Fishman, G. J.↗

Retinally stabilized differential resolution television display

A remote television viewing system employing an eye tracker is disclosed, wherein a small region of the image appears in high resolution, and the remainder of the image appears in low resolution. The eye tracker monitors the position of the viewer's line of sight. The eye tracker position data is transmitted to the remote television camera and control. Both the remote camera and television display are adapted to have selectable high-resolution and low resolution raster scan modes. The position data from the eye tracker is used to determine the point at which the high-resolution scan is to commence. The video data defining the observed image is encoded in a novel format, wherein in each data field, the data representing the position of the high resolution region of predetermined size appears first, followed by the high resolution zone video data and then the low-resolution region data. As the viewer's line of sight relative to the displayed image changes, the position of the high resolution region changes to track the viewer's line of sight.

Ruoff, C. F., Jr.↗

Fast Megavoltage Computed Tomography: A Rapid Imaging Method for Total Body or Marrow Irradiation in Helical Tomotherapy

Purpose: Megavoltage computed tomographic (MVCT) imaging has been widely used for the 3-dimensional (3-D) setup of patients treated with helical tomotherapy (HT). One drawback of MVCT is its very long imaging time, the result of slow couch speeds of approximately 1 mm/s, which can be difficult for the patient to tolerate. We sought to develop an MVCT imaging method allowing faster couch speeds and to assess its accuracy for image guidance for HT. Methods and Materials: Three cadavers were scanned 4 times with couch speeds of 1, 2, 3, and 4 mm/s. The resulting MVCT images were reconstructed using an iterative reconstruction (IR) algorithm with a penalty term of total variation and with a conventional filtered back projection (FBP) algorithm. The MVCT images were registered with kilovoltage CT images, and the registration errors from the 2 reconstruction algorithms were compared. This fast MVCT imaging was tested in 3 cases of total marrow irradiation as a clinical trial. Results: The 3-D registration errors of the MVCT images reconstructed with the IR algorithm were smaller than the errors of images reconstructed with the FBP algorithm at fast couch speeds (2, 3, 4 mm/s). The scan time and imaging dose at a speed of 4 mm/s were reduced to 30% of those from a conventional coarse mode scan. For the patient imaging, faster MVCT (3 mm/s couch speed) scanning reduced the imaging time and still generated images useful for anatomic registration. Conclusions: Fast MVCT with the IR algorithm is clinically feasible for large 3-D target localization, which may reduce the overall time for the treatment procedure. This technique may also be useful for calculating daily dose distributions or organ motion analyses in HT treatment over a wide area. Automated integration of this imaging is at least needed to further assess its clinical benefits.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-DE-BRA-09: Fast Megavoltage CT Imaging with Rapid Scan Time and Low Imaging Dose in Helical Tomotherapy

Purpose: Megavoltage computed tomography (MVCT) imaging has been widely used for daily patient setup with helical tomotherapy (HT). One drawback of MVCT is its very long imaging time, owing to slow couch speed. The purpose of this study was to develop an MVCT imaging method allowing faster couch speeds, and to assess its accuracy for image guidance for HT. Methods: Three cadavers (mimicking closest physiological and physical system of patients) were scanned four times with couch speeds of 1, 2, 3, and 4 mm/s. The resulting MVCT images were reconstructed using an iterative reconstruction (IR) algorithm. The MVCT images were registered with kilovoltage CT images, and the registration errors were compared with the errors with conventional filtered back projection (FBP) algorithm. Moreover, the fast MVCT imaging was tested in three cases of total marrow irradiation as a clinical trial. Results: Three-dimensional registration errors of the MVCT images reconstructed with the IR algorithm were significantly smaller (p < 0.05) than the errors of images reconstructed with the FBP algorithm at fast couch speeds (3, 4 mm/s). The scan time and imaging dose at a speed of 4 mm/s were reduced to 30% of those from a conventional coarse mode scan. For the patient imaging, a limited number of conventional MVCT (1.2 mm/s) and fast MVCT (3 mm/s) reveals acceptable reduced imaging time and dose able to use for anatomical registration. Conclusion: Fast MVCT with IR algorithm maybe clinically feasible alternative for rapid 3D patient localization. This technique may also be useful for calculating daily dose distributions or organ motion analyses in HT treatment over a wide area.

60 APPLIED LIFE SCIENCES↗

Scanning mechanism study for multi-frequency microwave radiometers

Scanning mode for a microwave radiometer having large aperture antenna is determined from scientific needs by engineering tradeoffs. Two configurations of the scan drive mechanism with an integral momentum compensation are formulated for 1.OM and 1.4M diameter antennas. As the formulation is based on currently available components, it is possible to design and fabricate the formulated mechanism without new hardware development. A preliminary specification for major components of formulated drives is also included in the report.

Shin, I.↗

A linear scanning balloon-borne telescope for far-infrared astronomy

A low-background balloon-borne far-infrared (30-300 microns) telescope, utilizing a linear scan mode has dramatically increased the efficiency of mapping large extended areas over more conventional systems. The system consists of a 20 cm linear scanned mirror mounted as an off-axis (Herchelian) telescope designed to achieve an emissivity of 1% or less, a ten position cooled aperture-filter wheel, a cooled Pfund optical system with a composite diamond-germanium bolometer mounted in a spherical cavity, a minimum phase shift ultra-low frequency amplifier, and a 4 micron thick mylar dewar window. This system was used to produce detailed far-infrared maps of the galactic plane. The system specifications and operating parameters will be discussed and preliminary data shown.

Nishimura, T.↗