Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sUAS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

75 records · Page 5

Method and apparatus for treatment planning using implanted radioactive seeds

A pre-computed sensitivity function providing ex ante assessment of optimal placement of a single radioactive seed, is used for sequential placement of multiple radioactive seeds. The location of each successive seed may also be constrained by an exclusion function omitting areas in the target receiving a pre-defined dose from the preexisting seeds. This technique makes possible optimization of additional dimensions of treatment planning including using a different number of needles and using mixed seed types.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of Volumetric Modulated Arc Therapy Technique on Treatment With Partial Breast Irradiation

Purpose: To investigate the technical feasibility of volumetric modulated arc therapy (V-MAT) in the delivery of partial breast irradiation (PBI). Methods and Materials: V-MAT and the standard, three-dimensional conformal radiotherapy (3D-CRT), were compared retrospectively in 8 patients previously treated with PBI. These patients' plans were replanned with a single partial arc using V-MAT that included partial blocking to minimize normal tissue dose. Dosimetric parameters were calculated to evaluate plan quality. Quality assurance studies included verifying both the point and the multiple planar doses. Total monitor units and delivery time were also evaluated, and collision clearance was analyzed. Results: Volumes of ipsilateral lung irradiated to 10 Gy (V10) and 20 Gy (V20) by V-MAT were significantly less than those of 3D-CRT (p = 0.03 for V10 and p = 0.025 for V20). The volume of ipsilateral breast irradiated to 5 Gy was significantly less by using V-MAT than with 3D-CRT (p = 0.02), with a ratio of integrated dose of <1.00. The total mean monitor units (489 {+-} 38) for V-MAT were significantly less than those for 3D-CRT (634 {+-} 123) (p = 0.017), with a 23% reduction. The average machine delivery time was 1.21 {+-} 0.10 min for the V-MAT plans and 6.28 {+-} 1.40 min for the 3D-CRT plans, resulting in a reduction factor of 80.1%. The conformity indexes were 1.3 in the V-MAT plans and 1.5 in the 3D-CRT plans (p = 0.102). Conclusions: V-MAT technology is feasible for PBI patients. Compared to a conventional 3D-CRT technique, it is more efficient, offers equivalent or better dose conformity, delivers lower doses to the ipsilateral lung and breast, and may potentially reduce intrafractional motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗