Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “root cause analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Rapid Characterization and Statistical Analysis of High-Volume Field-Harvested Photovoltaic Connectors

Photovoltaic (PV) installations heavily depend on connectors for efficient module and string interconnections without requiring skilled labor. Yet this seemingly innocuous component of PV systems is a leading cause of module failures, multiple high-profile fires, and lawsuits in the PV industry. This work aims to answer critical questions regarding why connectors fail and the contributing factors to their failure. The study involves collecting and analyzing more than 17,000 field-harvested connectors from various solar installations across the United States. The vast dataset, which includes connector metadata, visual inspections, and resistance measurements, provides unprecedented insight into the state of health of PV connectors across the US, including the geographic locations, connector types, and installation practices most prone to failures. The work presented here describes a novel rapid characterization method for processing large numbers of connectors and is supported by parallel forensic analysis to discern the root causes of failures as well as a levelized cost of lifetime model to determine the economic ramifications of connector failure. Ultimately, the findings may inform PV developers about the best practices to extend connector longevity and lead to more resilient and reliable PV systems.

connectors↗

Importance of limiting hohlraum leaks at cryogenic temperatures on NIF targets

Inertial confinement fusion targets are complex systems designed to allow fine control of temperature and pressure for making precise spherical ice layers of hydrogen isotopes at cryogenic temperatures. We discuss the various technical considerations for a maximum leak rate based on heat load considerations. This maximum flow rate turns out to be $5\times 10^{-6}$ standard cc per second, which can be caused by an orifice less than half a micron in diameter. This makes the identification of the location and resolution of the leak a significant challenge. To illustrate this, we showcase one example of a peculiar failure mode that appeared suddenly but persisted whereby target production yield was severely lowered. Identification of the leak source and the root cause requires very careful analysis of multiple thermomechanical aspects to ensure that the end solution is indeed the right remedy and is robust.

36 MATERIALS SCIENCE↗

Exergy analysis and operational efficiency of a horizontal ground-source heat pump system operated in a low-energy test house simulated occupancy conditions

This paper presents detailed analysis of a water to water ground source heat pump (WW-GSHP) to provide all the hot water needs in a 345 m 2 house located in DOE climate zone 4 (mixed-humid). The protocol for hot water use is based on the Building America Research Benchmark Definition (Hendron 2008; Hendron and Engebrecht 2010) which aims to capture the living habits of the average American household and its impact on energy consumption. The entire house was operated under simulated occupancy conditions. Detailed energy and exergy analysis provides a complete set of information on system efficiency and sources of irreversibility, the main cause of wasted energy. The WW-GSHP was sized at 5.275 kW (1.5-ton) for this house and supplied hot water to a 303 L (80 gal) water storage tank. The WW-GSHP shared the same ground loop with a 7.56 kW (2.1-ton) water to air ground source heat pump (WA-GSHP) which provided space conditioning needs to the entire house. Data, analyses, and measures of performance for the WW-GSHP in this paper complements the results of the WA-GSHP published in this journal (Ally, Munk et al. 2012). Understanding the performance of GSHPs is vital if the ground is to be used as a viable renewable energy resource.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy and Exergy Analysis of Low-Global Warming Potential Refrigerants as Replacement for R410A in Two-Speed Heat Pumps for Cold Climates

Heat pumps (HPs) are being developed with a new emphasis on cold climates. To lower the environmental impact of greenhouse gas (GHG) emissions, alternate low global warming potential (GWP) refrigerants must also replace the exclusive use of the refrigerant R410A, preferably without re-engineering the mechanical hardware. In this paper, we analyze the performance of four low-GWP alternative refrigerants (R32, R452B, R454B, and R466A) relative to the conventional R410A and draw conclusions on the relative performances for providing heating in cold climates based on the Air-Conditioning, Heating, and Refrigeration Institute (AHRI) 210/240 standard for two-speed heat pumps. The simulations are carried using the Department of Energy, Oak Ridge National Laboratory (DOE/ORNL) Heat Pump Design Model (HPDM), a well-known heating, ventilation, and air conditioning (HVAC) modeling and design tool in the public domain and the HVAC research and development community. The results of the simulation are further scrutinized using exergy analysis to identify sources of systemic inefficiency, the root cause of lost work. This rigorous approach provides an exhaustive analysis of alternate low-GWP refrigerants to replace R410A using available compressors and system components, without compromising performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparative Performance of Low Global Warming Potential (GWP) Refrigerants as Replacement for R-410A in a Regular 2-Speed Heat Pump for Sustainable Cooling

Heat pumps are currently being developed to reduce the energy footprint for residential and commercial building space conditioning and water heating loads in cold climates. To mitigate the nocuous impact of greenhouse gas emissions on the environment, and to create a carbon-neutral building stock, alternate lower-GWP refrigerants must also replace the predominant use of R-410A, without re-engineering the mechanical hardware. In this paper, we analyze the performance of lower-GWP alternative refrigerants (R-32, R-452B, R-454B, and R-466A) relative to the conventional R-410A and draw conclusions on the relative performances to meet cooling loads. The simulations are accomplished using the heat pump design model, a well-known, public-domain design tool with a free web interface and downloadable desktop version to support public use and the HVAC R&D community. The contributions contain detailed, hardware-based heat exchanger and system analyses to provide a comprehensive assessment. The results of the simulation are scrutinized from the first (capacity and energy efficiency) and second laws (exergy analysis) to identify sources of systemic inefficiency, the root cause of lost work. This rigorous approach provides an exhaustive analysis of alternate lower-GWP refrigerants to replace R-410A using the same hardware. The results have practical value in engineering heat pumps in an economy that is compelled to alter by the consequences and uncertainties of climate change, to reduce its anthropogenic carbon footprint.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Strain energy-based fatigue failure analyses of LB-PBF Inconel 718: Effect of build orientation

Additively manufactured Inconel 718 parts fabricated in three build orientations (horizontal, vertical, and angled at 45 degrees) are tested in fully-reversed bending fatigue mode. Damping measurements via the Impulse Excitation technique are used to assess the defects content in the microstructure and fractography analysis is performed to detect the root cause of failure. Two micro- and macro-scale methodologies of fatigue damage estimation based on the dissipated heat per cycle and the statistical estimation of micro-plastic strain energies are used to assess fatigue damage. It is shown that at a given stress level, the vertically built specimens endure the most fatigue damage before failure while the diagonally built ones sustain the least. As a result, the fatigue life is estimated for arbitrary load amplitudes via a microstructure-sensitive algorithm with acceptable accuracy as compared to the experiments.

36 MATERIALS SCIENCE↗

Options for low-global-warming-potential and natural refrigerants part I: Constrains of the shape of the P–T and T–S saturation phase boundaries

Current research focus is migrating toward low-global-warming-potential (GWP) and natural refrigerants to address the human impact on climate change. In this paper, we examine 13 refrigerants from the perspective of the characteristic shape of their respective temperature–entropy (T–S) and the logarithm of the pressure versus inverse absolute temperature (log P vs. T –1 ) saturated phase boundary. Such analyses explain why certain refrigerants possess a re-entrant characteristic while others do not. The re-entrant region is due to skewness of the saturation boundary. The cause of skewness is investigated for its importance in heat pump performance, design, and configuration. Re-entrant behavior contributes to premature mechanical wear of compressor components. Knowledge of the properties of the phase boundary on either side of the critical point, is useful for a better perspective on discriminating refrigerants, as hydrochlorofluorocarbons are phased out and replacement refrigerants must be found. Here, we conclude by identifying a candidate low-GWP refrigerant for heat pumps. In Part II, we evaluate all 13 refrigerants in thermodynamic cycles based on exergy analysis to identify sources of irreversibility, the root cause of systemic inefficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Metallurgical Failure Analysis of A2 Tool Steel Die Set from High Explosive Pellet Pressing Event

On 2 April 2018, a high explosive violent reaction (HEVR) occurred during routine pressing of a 1-in -diameter cylindrical pellet of PBX 9501 high explosive. Fragments of the die set (die body and stemples) involved in the event were sent to Sigma Division for metallurgical analysis. A handheld x-ray fluorescence alloy tester confirmed the die set material to be A2 tool steel. Light optical microscopy revealed what appear to be pre-existing flaws on the inner diameter of the die body. Scanning Electron Microscopy could neither confirm nor exclude the presence of fatigue cracking in the vicinity of these potential flaws. Energy Dispersive Spectroscopy indicated the presence of a carbon-bearing residue on fracture surfaces; nitrogen-bearing residue was also found. Optical microscopy revealed that the microstructure of the stemple and inner diameter of the die body contained large stringers and non-uniform grain size; this was distinct from the relatively clean and uniform microstructure seen at the outer diameter of the die body, and also other A2 tool steel stock (pedigree unknown and with no known connection to any HE pressing hardware) that was examined for additional comparison. Rockwell hardness testing indicated the material was heat treated properly. Metallographic analysis alone could not positively identify the root cause of the event, but, coupled with accounts provided by the operator and the successful history with the particular lot of HE involved in the event, points to ward mechanical failure of the die set due to pre -existing flaw as the most likely precipitating event. Suggestions for additional analyses and future qualification techniques are discussed.

36 MATERIALS SCIENCE↗

Collecting sensor data in a high-performance computing environment: a case-study

Many research questions remain open with regard to improving reliability in exascale systems. Among others, statistics-based analysis has been used to find anomalies, to isolate root causes, and attempt to predict failures. But well-understood methods and best practices for collecting reliability data in a uniform way are still lacking, which impedes analysis. We report our experience with collecting these data from heterogeneous sources on a testbed cluster and present our data collection tool. This case illustrates the fact that reported metrics largely depend upon individual system configuration. We then investigate standards and specifications in manufacturing and desktop computing to identify concepts that may be useful for representing High Performance Computing (HPC) data and present a taxonomy that utilizes these concepts.

99 GENERAL AND MISCELLANEOUS↗

The Distribution of U.S. Electric Utility Revenue Decoupling Rate Impacts from 2005 to 2017

Investments in energy efficiency and distributed generation reduce electric utility retail sales. Since electric utilities have historically collected a large portion of revenues from volumetric energy rates (¢/kWh), such reductions in sales can impact the utility’s ability to sufficiently recover non-production costs. Regulatory mechanisms that “decouple” utility revenues from sales were implemented to help make the utility indifferent to energy efficiency and distributed generation by ensuring the utility is able to collect an allowed level of revenue each year regardless of its sales. However, noticeable and consistent surcharges over time may create the perception of an incorrectly designed or implemented decoupling mechanism. To date, there are limited quantitative analyses of the rate adjustments due to decoupling mechanisms implemented among U.S. electric utilities (see Morgan, 2013). Given the recent rapid increase in distributed energy resource (DER) adoption in some states and utility service territories, consumers may be facing more prevalent and ongoing decoupling surcharges. This, in turn, may undermine stakeholder support for implementation of decoupling mechanisms and the associated utility support for energy efficiency and DERs. To determine the size of retail rate adjustments associated with decoupling mechanisms and whether they have a tendency towards bill surcharges or credits, we analyzed a large dataset of historical annual decoupling rate adjustments for 21 electric utilities in 11 states between 2005 and 2017. We found that decoupling mechanisms adjusted rates, both up and down, between rate cases, and the majority of those adjustments (54 percent) are small (within a range of -1 to 1 percent). However, we also found that 64 percent of the rate adjustment observations in our sample showed a positive rate adjustment. Importantly, once a surcharge is applied there is an 86 percent chance that there will be a surcharge in the next year as well. While our analysis did not seek to understand the root causes for such results, some possible factors include the accuracy of revenue requirement forecasts, emerging structural changes in customer use and production of energy, misaligned financial motivation, and other factors that influence sales (e.g., economic recession).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Reverse genetic characterization of two paralogous acetoacetyl CoA thiolase genes in Arabidopsis reveals their importance in plant growth and development

Acetoacetyl CoA thiolase (AACT, EC 2.3.1.9) catalyzes the condensation of two acetyl CoA molecules to form acetoacetyl CoA. Two AACT-encoding genes, At5g47720 (AACT1) and At5g48230 (AACT2), were functionally identified in the Arabidopsis genome by direct enzymological assays and functional expression in yeast. Promoter::GUS fusion experiments indicated that AACT1 is primarily expressed in the vascular system and AACT2 is highly expressed in root tips, young leaves, top stems and anthers. Characterization of T-DNA insertion mutant alleles at each AACT locus established that AACT2 function is required for embryogenesis and for normal male gamete transmission. In contrast, plants lacking AACT1 function are completely viable and show no apparent growth phenotypes, indicating that AACT1 is functionally redundant with respect to AACT2 function. RNAi lines that express reduced levels of AACT2 show pleiotropic phenotypes, including reduced apical dominance, elongated life span and flowering duration, sterility, dwarfing, reduced seed yield and shorter root length. Microscopic analysis reveals that the reduced stature is caused by a reduction in cell size and fewer cells, and male sterility is caused by loss of the pollen coat and premature degeneration of the tapetal cells. Biochemical analyses established that the roots of AACT2 RNAi plants show quantitative and qualitative alterations in phytosterol profiles. These phenotypes and biochemical alterations are reversed when AACT2 RNAi plants are grown in the presence of mevalonate, which is consistent with the role of AACT2 in generating the bulk of the acetoacety CoA precursor required for the cytosol-localized, mevalonate-derived isoprenoid biosynthetic pathway.

36 MATERIALS SCIENCE↗

Drivers for the cracking of multilayer polyamide‐based backsheets in field photovoltaic modules: In‐depth degradation mapping analysis

Abstract There is a lack of understanding on the root cause of cracking of photovoltaic (PV) backsheets due to the challenge of multilayer characterization and the complicated failure modes at the submodule level. In this work, the in‐depth degradation mapping of field‐exposed polyamide‐based (PA‐based) PV module backsheets was studied, with the major focus on the identification of underlying drivers for the through cracking (in between the solar cells). PV modules were retrieved from five different locations, comprising a variety of climates, including humid subtropical, hot‐summer Mediterranean, tropical savanna climate, and hot arid. A suite of microscale cross‐sectional characterizations, including chemical changes, fluorescence intensity, and modulus as a function of distance from the air surface of the backsheet, was performed. Results showed more advanced signs of degradation of the inner layer than the outer layer in the cracking region. Increases in the modulus were identified as the major indicator for the cracking. Moreover, a rudimentary test by immersion in acetic acid, which forms during photodegradation of the ethylene‐vinyl acetate copolymer (EVA) encapsulant, showed the first‐time direct evidence that acetic acid can largely accelerate the chemical degradation and facilitate the cracking of PA inner layer. This study suggests that the field cracking of PA‐based backsheet can be attributed to the combined effects of chemical degradation and physical reorganization (chemi‐crystallization) under cyclic thermomechanical stresses. Therefore, it is important to consider effects of local microclimates and interlayer infection to understand the heterogeneous nature of backsheet failures.

Lyu, Yadong↗

Retail Hydrogen Station Reliability Status and Advances

One of the most vital emerging commercial markets for hydrogen is fuel cell-powered mobility including cars, trucks, and buses. These vehicles are refueled via a network of hydrogen fueling stations, with the highest number of U.S. stations being in California. The numbers of both fuel cell electric vehicles (FCEVs) and hydrogen stations have increased in the last two years, with anecdotal information from FCEV drivers indicating that station reliability is hurting the consumer acceptability of FCEV technologies. Therefore, this study benchmarks the current state of hydrogen station reliability in practice and presents on-going research that is investigating the failures that are contribute to hydrogen station reliability issues. This is accomplished with an analysis of operation, safety, and maintenance data from hydrogen stations and fuel cell electric vehicles to benchmark the maintenance and failure of hydrogen stations and their components. This analysis, of over 5,000 station maintenance events, presents the leading maintenance categories and failure rates, and is a prerequisite to the development of data-driven reliability improvement plans. We present a reliability growth analysis and on-going research into the root causes of failure for dispensers, a particularly failure-prone subsystem.

08 HYDROGEN↗