Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “roof”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Roof Support Near Coal-Mining Face

Hydraulically-powered legs mounted on crawlers and carrying sections of conveyors provide roof support close to working face and above workspace at all times.

Knurovsky, T.↗

Roof Polishing of Optical Fibers

Bevealed tip gives optimum coupling efficiency. Abrasive tape used to grind tip of optical fiber. Grinding force depends on stiffness of optical fiber. "Roof" shape on end of optical glass fiber increases efficiency which couples laser light. End surface angle of 65 degrees with perpendicular required for optimum coupling. Since fiber and tape are light in weight and compliant, ridge defect-free, and chipping on fiber edge totally eliminated.

Dholakia, A. R.↗

Roof Shield for Advance and Retreat Mining

Shield sections change their configuration to suit mining mode. Articulation cylinders raise rear shield to advance position, and locking cylinders hold it there. To change to retreat position articulation cylinders lower shield. Locking pins at edge of outermost shield plate latch shield to chock base. Shield accommodates roof heights ranging from 36 to 60 inches (0.9 to 1.52 meters).

Lewis, E. V.↗

A Roof for the Lions' House

Fans of the National Football League s Detroit Lions don't worry about game day weather. Their magnificent new Pontiac Stadium has a domed, air-supported, fabric roof that admits light but protects the playing field and patrons from the elements. The 80,000-seat Silverdome is the world s largest fabric-covered structure-and aerospace technology played an important part in its construction. The key to economical construction of the Silverdome--and many other types of buildings--is a spinoff of fiber glass Beta yarn coated with Teflon TFE fluorocarbon resin. The big advance it offers is permanency.The team of DuPont, Chemical Fabrics and Birdair have collaborated on a number of fabric structures. Some are supported by air pressure, others by cables alone. Most of the structures are in the recreational category. With conventional construction costs still on the upswing, you're likely to see a great many more permanent facilities enclosed by the aerospace spinoff fabric.

Source record↗

Investigation of the Building M6-794 Roofing Fatality, Type A Mishap

The Building M6-794 Roofing Fatality Mishap Investigation Board (Board) was commissioned to gather information; analyze the facts; identify the proximate causes, root causes, and contributing factors relating to the mishap; and recommend appropriate actions to prevent a similar mishap from occurring in the future. During the investigation of this mishap, the Board also examined the fall protection policies of other NASA Centers and operating locations to gain an understanding of how those entities conduct fall protection, as well as the degree to which fall protection is standardized across the Agency.

Casper, John H.↗

Parallel Multi-cycle LES of an Optical Pent-roof DISI Engine Under Motored Operating Conditions

The use of Large-eddy Simulations (LES) has increased due to their ability to resolve the turbulent fluctuations of engine flows and capture the resulting cycle-to-cycle variability. One drawback of LES, however, is the requirement to run multiple engine cycles to obtain the necessary cycle statistics for full validation. The standard method to obtain the cycles by running a single simulation through many engine cycles sequentially can take a long time to complete. Recently, a new strategy has been proposed by our research group to reduce the amount of time necessary to simulate the many engine cycles by running individual engine cycle simulations in parallel. With modern large computing systems this has the potential to reduce the amount of time necessary for a full set of simulated engine cycles to finish by up to an order of magnitude. In this paper, the Parallel Perturbation Methodology (PPM) is used to simulate up to 35 engine cycles of an optically accessible, pent-roof Directinjection Spark-ignition (DISI) engine at two different motored engine operating conditions, one throttled and one un-throttled. Comparisons are made against corresponding sequential-cycle simulations to verify the similarity of results using either methodology. Mean results from the PPM approach are very similar to sequential-cycle results with less than 0.5% difference in pressure and a magnitude structure index (MSI) of 0.95. Differences in cycle-to-cycle variability (CCV) predictions are larger, but close to the statistical uncertainty in the measurement for the number of cycles simulated. PPM LES results were also compared against experimental data. Mean quantities such as pressure or mean velocities were typically matched to within 5- 10%. Pressure CCVs were under-predicted, mostly due to the lack of any perturbations in the pressure boundary conditions between cycles. Velocity CCVs for the simulations had the same average magnitude as experiments, but the experimental data showed greater spatial variation in the root-mean-square (RMS). Conversely, circular standard deviation results showed greater repeatability of the flow directionality and swirl vortex positioning than the simulations.

I.C. Engines↗

Close roof-mounted system temperature estimation for compliance to IEC TS 63126

When photovoltaic (PV) modules are installed on rooftops, the module temperature depends primarily on the geographic location and the mounting configuration. If the mounting structure does not provide sufficient airflow in a hot environment, the 98th percentile temperature will exceed 70°C, which according to IEC TS 63126 ED. 1, requires higher levels of thermal stability testing. However, there is no clear way to determine the temperature level needed for a particular location and system design. Here, in this work, we identify a relationship between the module standoff to the rooftop and the module temperature and propose methods to describe a minimum standoff for typical PV modules in a simple mounting configuration installed in a given location. For more complex system designs, we show how to determine an equivalent “effective standoff” that can be applied to generic calculations. Lastly, we show measurements and calculations from several systems to demonstrate how this method could work.

14 SOLAR ENERGY↗

Statistical Properties for Flows with Unbounded Roof Function, Including the Lorenz Attractor

For geometric Lorenz attractors (including the classical Lorenz attractor) we obtain a greatly simplified proof of the central limit theorem which applies also to the more general class of codimension two singular hyperbolic attractors. We also obtain the functional central limit theorem and moment estimates, as well as iterated versions of these results. A consequence is deterministic homogenisation (convergence to a stochastic differential equation) for fast-slow dynamical systems whenever the fast dynamics is singularly hyperbolic of codimension two.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

From roads to roofs: How urban and rural mobility influence building energy consumption

In this article, understanding the relationship between travel behavior and building energy use at an urban scale is crucial for developing effective energy management strategies. Mobility patterns significantly impact building occupancy, which in turn affects energy consumption. However, existing methods often focus on individual buildings, whereas geographical influences on energy usage are not adequately examined. This study addresses this gap by using transportation origin-destination (OD) data to estimate building occupancy and energy. The proposed method assigns OD trips from census block groups to the building level, incorporating building, travel survey, and census data to derive building occupancy profiles. This method was applied to urban and rural areas with 4062 buildings in 70 census block groups. We found that the OD-informed occupancy profile exhibits smoother energy consumption patterns compared with that of Department of Energy reference occupancy profiles. Our analysis reveals distinct building energy consumption patterns among groups with long and short commutes, emphasizing the effect of commute times and work schedules on residential energy usage. This framework is useful for practitioners in transportation agencies and utility companies, enabling the estimation of building energy based on mobility patterns. Overall, this study shows the potential of integrating transportation and building energy data to inform cross-sector energy management strategies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗