Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “risk-based security”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

83 records · Page 5

Application of quantitative risk assessment to address stakeholder questions in geologic carbon storage

Ambitious international greenhouse gas emissions reduction targets demand a rapid transformation to a low-carbon economy. This transformation includes the accelerated adoption of carbon dioxide (CO2) capture and storage (CCS) technology. However, as with any large-scale engineering enterprise, the widespread commercial-scale deployment of geologic carbon storage (GCS) raises important questions about technology and cost-effectiveness, safety, environmental risk, and long-term liability. Effectively assessing and managing risks and liability associated with GCS projects is a key technical need throughout the project life cycle-from site selection and permitting to monitoring design, operational risk management, and post-operational site closure. This presentation highlights recent advancements in tools for quantitative risk assessment, being developed by the National Risk Assessment Partnership (NRAP). NRAP is a multi-year, multinational laboratory research collaboration sponsored by the U.S. Department of Energy's Office of Fossil Energy and Carbon Management. Our focus will be on these tools' applications in addressing critical stakeholder questions related to supporting permitting to ensure secure and environmentally protective storage; designing effective and efficient monitoring plans; evaluating the effectiveness of remedial actions and risk management alternatives; and informing liability assessment and investment decisions. This paper will detail the key functionality of NRAP’s Open-Source Integrated Assessment Model (NRAP-Open-IAM), a computational framework for assessing leakage risk and containment assurance. This model features streamlined workflows for calculating leakage risk profiles, delineating risk-based area of review, and assessing contingency plans and post-injection site care requirements. ORION is an open-source, observation-based ensemble forecasting toolkit to help operators assess the seismic hazard at a carbon storage site. The State of Stress Analysis Tool (SOSAT), designed to assess subsurface stress conditions and evaluate geomechanical risk resulting from CO2 injection in an area of interest will also be presented. We will also introduce a prototype model to evaluate storage project costs and liability associated with risk management. The Technoeconomic and Liability Evaluation for Storage (TALES) model uses results from forecasts of leakage and induced seismicity risk to estimate the lifecycle cost of managing risk. Finally, a preliminary example of how the NRAP Risk-based Adaptive Monitoring Plan (RAMP) tool can be used to design efficient and effective site monitoring plans and estimate the detectability of fluid leakage will be provided. The relevance of these tools for addressing key stakeholder questions amidst uncertainty will be emphasized.

decision support↗

A conceptual evaluation framework for the water and sanitation for health facility improvement tool (Wash Fit)

Healthcare facilities (HCFs) in low- and middle-income countries frequently lack water, sanitation and hygiene (WASH) services that are adequate to implement infection prevention and control (IPC) practices, decrease healthcare-associated infections and antimicrobial resistance, and provide quality healthcare. The Water and Sanitation for Health Facility Improvement Tool (WASH FIT), initially published in 2017 and updated in 2018, is a risk-based, continuous improvement framework. The tool aims to improve WASH and related facility management and may contribute to quality of care (QoC) efforts. To date, there is no guidance available on how to monitor and evaluate the use of this tool nor is there rigorous evidence on its effectiveness. We developed a conceptual WASH FIT evaluation framework by drawing from the broader WASH, health systems strengthening, and QoC evidence base. This framework provides a common basis to plan, implement, monitor, and evaluate potential inputs, outputs, outcomes, and impacts from applying WASH FIT. Routine use of the tool, coupled with WASH infrastructure improvements as guided by the tool, can lead to better IPC practices, and may support improvements in occupational safety, QoC, global health security, and ultimately progress towards achieving Sustainable Development Goals 3 (good health and well-being) and 6 (clean water and sanitation).

60 APPLIED LIFE SCIENCES↗

Industrial Control Systems: Cyber Security Risk Candidate Methods Analysis

In recognition of their mission and in response to continuously evolving cyber threats against nuclear facilities, Department of Energy - Nuclear Energy (DOE-NE) is building the Nuclear Energy Cyber security Research, Development, and Demonstration (RD&D) Program, which includes a cyber risk management thrust. This report supports the cyber risk management thrust objective which is to deliver "Standardized methodologies for credible risk-based identification, evaluation and prioritization of digital components." In a previous task, the Sandia National Laboratories (SNL) team presented evaluation criteria and a survey to review methods to determine the most suitable techniques. In this task we will identify and evaluate a series of candidate methodologies. In this report, 10 distinct methodologies are evaluated. The overall goal of this effort was to identify the current range of risk analysis techniques that were currently available, and how they could be applied, with an focus on industrial control systems (ICS). Overall, most of the techniques identified did fall into accepted risk analysis practices, though they generally addressed only one step of the multi-step risk management process. A few addressed multiple steps, but generally their treatment was superficial. This study revealed that the current state of security risk analysis in digital control systems was not comprehensive and did not support a science-based evaluation. The papers surveyed did use mathematical formulation to describe the addressed problems, and tied the models to some kind of experimental or experiential evidence as support. Most of the papers, however, did not use a rigorous approach to experimentally support the proposed models, nor did they have enough evidence supporting the efficacy of the models to statistically analyze model impact. Both of these issues stem from the difficulty and expense associated with collecting experimental data in this domain.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

A Cultural Resources Inventory and Historical Evaluation of the Shasta Atmospheric Test, Areas 2, 4, and 8, Nevada National Security Site, Nye County, Nevada

This report presents the results of a National Historic Preservation Act Section 106 cultural resources inventory and historical evaluation of the 1957 Shasta atmospheric test area located on the Nevada National Security Site. The Desert Research Institute was tasked to conduct a cultural resources inventory of the Shasta test close-in ground zero area as a result of a proposed undertaking by the U.S. Department of Energy Environmental Management. This undertaking involves investigation of Corrective Action Site (CAS) 02-23-05 for potential contaminants of concern as delineated in the Corrective Action Investigation Plan. Based on the investigation, contaminants exceeding risk-based levels would be the subject of corrective actions. The CAS 02-23-05 area coincides with a historic resource and corrective actions would potentially have an adverse effect on a historic property.

1957↗

Hydropower Cybersecurity Value-at-Risk Framework

Hydropower remains one of the strongest forms of renewable energy generation methods. It is crucial to address the increasing risks associated with the rapid digitization. The push towards decarbonization also factors in the need to ensure security and resilience for grid-connected renewable energy resources. This report summarizes the U.S. Department of Energy's Water Power Technologies Office's effort to develop a cybersecurity valuation methodology that assists hydropower stakeholders in assessing risks associated with plan operations and gathers valuation guidance through a web-based application. The Hydropower Cybersecurity Value-at-Risk Framework delivers a platform for industry members to perform self-assessments and make informed decisions on their cybersecurity investments.

13 HYDRO ENERGY↗

Plant Disease Detection Technology Assessment

Visual inspections by US Customs and Border Protection agriculture specialists have identified approximately 20,000 regulated, quarantined pests each year in agricultural products entering the United States. Most of these pests identified in the Agriculture Quarantine and Inspection (AQI) program are insects. Many pathogens are difficult to detect in agricultural products, particularly in early stages of infection. New technologies can help to detect plant pathogens and the diseases that they cause. This technology assessment was performed for the US Department of Homeland Security Science and Technology Directorate (DHS S&T) through the Food, Agriculture, and Veterinary Defense (FAV-D) program to identify emerging technologies that could address this hard problem. These emerging technologies differ in their diagnostic sensitivities and specificities, as well as in their measurement time and training requirements. New instruments that detect volatile organic compounds characteristic of plant disease or pathogens could provide a less invasive inspection method. Dogs, which can successfully detect many concealed agricultural products, have also been trained to detect some plant pests and pathogens. Simple immunological tests offer sensitive and specific detection of many pathogens at the point of use. Advanced imaging methods that use AI to sort fruits and vegetables and recognize anomalies at high speeds could be used in cooperation with exporters to improve food quality and reduce pests. Advances in nucleic acid–based detection methods that have become gold standards for confirmatory diagnostics are now making those methods available for faster, point-of-use detection. These new methods should be developed in the context of AQI operational requirements, which apply risk-based sampling protocols to protect agriculture and facilitate commerce and passenger transit.

59 BASIC BIOLOGICAL SCIENCES↗

Addendum to the Closure Report for Corrective Action Unit 271: Areas 25, 26, and 27 Septic Systems Nevada Test Site, Nevada, Revision 0 with ROTC 1

This document constitutes an addendum to the August 2004, Closure Report for Corrective Action Unit 271, Areas 25, 26, and 27 Septic Systems as described in the document Recommendations and Justifications for Modifications for Use Restrictions Established under the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office Federal Facility Agreement and Consent Order (UR Modification document) dated February 2008. The UR Modification document was approved by NDEP on February 26, 2008. The approval of the UR Modification document constituted approval of each of the recommended UR modifications. In conformance with the UR Modification document, this addendum consists of: • This cover page that refers the reader to the UR Modification document for additional information • The cover and signature pages of the UR Modification document • The NDEP approval letter • The corresponding section of the UR Modification document This addendum provides the documentation justifying the modification of the UR for CAS 27-05-02, Leachfield. This UR was established as part of a Federal Facility Agreement and Consent Order (FFACO) corrective action and is based on the presence of contaminants at concentrations greater than the action levels established at the time of the initial investigation (FFACO, 1996; as amended August 2006). Since this UR was established, practices and procedures relating to the implementation of risk-based corrective actions (RBCA) have changed. Therefore, this UR was re-evaluated against the current RBCA criteria as defined in the Industrial Sites Project Establishment of Final Action Levels (NNSA/NSO, 2006c). This re-evaluation consisted of comparing the original data (used to define the need for the UR) to risk-based final action levels (FALs) developed using the current Industrial Sites RBCA process. The re-evaluation resulted in a recommendation to modify the UR to an administrative UR. Administrative URs differ from standard URs in that they do not require onsite postings (i.e., signs) or other physical barriers (e.g., fencing, monuments), and they do not require periodic inspections (see Section 6.2 of the Industrial Sites Project Establishment of Final Action Levels [NNSA/NSO, 2006c]). This Administrative UR was based on an “Occasional Use Area” future land use scenario that was used to calculate the FAL. The administrative UR will protect workers from an exposure exceeding that used in the calculation of the FAL (i.e., 400 total work hours). Any proposed activity within this use restricted area that would potentially cause an exposure exceeding this exposure limit would require approval from the Nevada Division of Environmental Protection (NDEP). Requirements for inspecting and maintaining postings at this UR will be canceled, and the postings and signage at this site will be removed. Fencing and posting may be present at this site that are unrelated to the FFACO UR such as for radiological control purposes as required by the NV/YMP Radiological Control Manual (NNSA/NSO, 2004f). This modification will not affect or modify any non-FFACO requirements for fencing, posting, or monitoring at this site.

01 COAL, LIGNITE, AND PEAT↗

Addendum to the Closure Report for Corrective Action Unit 404: Roller Coaster Lagoons and Trench, Tonopah Test Range, Nevada, Revision 0

This document constitutes an addendum to the September 1998, Closure Report for Corrective Action Unit 404: Roller Coaster Lagoons and Trench, Tonopah Test Range, Nevada as described in the document Recommendations and Justifications for Modifications for Use Restrictions Established under the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office Federal Facility Agreement and Consent Order (UR Modification document) dated February 2008. The UR Modification document was approved by NDEP on February 26, 2008. The approval of the UR Modification document constituted approval of each of the recommended UR modifications. In conformance with the UR Modification document, this addendum consists of: • This cover page that refers the reader to the UR Modification document for additional information • The cover and signature pages of the UR Modification document • The NDEP approval letter • The corresponding section of the UR Modification document This addendum provides the documentation justifying the cancellation of the URs for: • CAS TA-03-001-TARC Roller Coaster Lagoons • CAS TA-21-001-TARC Roller Coaster N. Disposal Trench These URs were established as part of Federal Facility Agreement and Consent Order (FFACO) corrective actions and were based on the presence of contaminants at concentrations greater than the action levels established at the time of the initial investigation (FFACO, 1996; as amended August 2006). Since these URs were established, practices and procedures relating to the implementation of risk-based corrective actions (RBCA) have changed. Therefore, these URs were re-evaluated against the current RBCA criteria as defined in the Industrial Sites Project Establishment of Final Action Levels (NNSA/NSO, 2006c). This re-evaluation consisted of comparing the original data (used to define the need for the URs) to risk-based final action levels (FALs) developed using the current Industrial Sites RBCA process. The re-evaluation resulted in a recommendation to modify these URs to administrative URs. Administrative URs differ from standard URs in that they do not require onsite postings (i.e., signs) or other physical barriers (e.g., fencing, monuments), and they do not require periodic inspections (see Section 6.2 of the Industrial Sites Project Establishment of Final Action Levels [NNSA/NSO, 2006c]). These Administrative URs were based on a “Remote Work Sites” future land use scenario that was used to calculate the FAL. The administrative UR will protect workers from an exposure exceeding that used in the calculation of the FAL (i.e., 336 hours per year). Any proposed activity within these use restricted areas that would potentially cause an exposure exceeding this exposure limit would require approval from the Nevada Division of Environmental Protection (NDEP). Requirements for inspecting and maintaining these URs will be canceled, and the postings and signage at each site will be removed. Fencing and posting may be present at these sites that are unrelated to the FFACO URs such as for radiological control purposes as required by the NV/YMP Radiological Control Manual (NNSA/NSO, 2004f). This modification will not affect or modify any non-FFACO requirements for fencing, posting, or monitoring at these sites.

54 ENVIRONMENTAL SCIENCES↗

Addendum to the Closure Report for Corrective Action Unit 404: Roller Coaster Sewage Lagoons and North Disposal Trench, Tonopah Test Range, Nevada, Revision 1

This document constitutes an addendum to the September 1998, Closure Report for Corrective Action Unit 404: Roller Coaster Lagoons and Trench, Tonopah Test Range, Nevada as described in the document Recommendations and Justifications for Modifications for Use Restrictions Established under the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office Federal Facility Agreement and Consent Order (UR Modification document) dated February 2008. The UR Modification document was approved by NDEP on February 26, 2008. The approval of the UR Modification document constituted approval of each of the recommended UR modifications. In conformance with the UR Modification document, this addendum consists of: • This cover page that refers the reader to the UR Modification document for additional information • The cover and signature pages of the UR Modification document • The NDEP approval letter • The corresponding section of the UR Modification document This addendum provides the documentation justifying the modification of the UR for CAS TA-03-001-TARC Roller Coaster Lagoons. This UR was established as part of Federal Facility Agreement and Consent Order (FFACO) corrective actions and was based on the presence of contaminants at concentrations greater than the action levels established at the time of the initial investigation (FFACO, 1996; as amended August 2006). Since this UR was established, practices and procedures relating to the implementation of risk-based corrective actions (RBCA) have changed. Therefore, this UR was re-evaluated against the current RBCA criteria as defined in the Industrial Sites Project Establishment of Final Action Levels (NNSA/NSO, 2006c). This reevaluation consisted of comparing the original data (used to define the need for the UR) to risk-based final action levels (FALs) developed using the current Industrial Sites RBCA process. The re-evaluation resulted in a recommendation to modify the UR for CAS TA-03-001-TARC to an administrative UR. Administrative URs differ from standard URs in that they do not require onsite postings (i.e., signs) or other physical barriers (e.g., fencing, monuments), and they do not require periodic inspections (see Section 6.2 of the Industrial Sites Project Establishment of Final Action Levels [NNSA/NSO, 2006c]). This Administrative UR was based on a “Remote Work Sites” future land use scenario that was used to calculate the FAL. The administrative UR will protect workers from an exposure exceeding that used in the calculation of the FAL (i.e., 336 hours per year). Any proposed activity within these use restricted areas that would potentially cause an exposure exceeding this exposure limit would require approval from the Nevada Division of Environmental Protection (NDEP). Requirements for inspecting and maintaining this UR will be canceled, and the postings and signage at each site will be removed. Fencing and posting may be present at these sites that are unrelated to the FFACO URs such as for radiological control purposes as required by the NV/YMP Radiological Control Manual (NNSA/NSO, 2004f). This modification will not affect or modify any non-FFACO requirements for fencing, posting, or monitoring at these sites.

54 ENVIRONMENTAL SCIENCES↗

Statistical language analysis for automatic exfiltration event detection.

This paper discusses the recent development a statistical approach for the automatic identification of anomalous network activity that is characteristic of exfiltration events. This approach is based on the language processing method eferred to as latent dirichlet allocation (LDA). Cyber security experts currently depend heavily on a rule-based framework for initial detection of suspect network events. The application of the rule set typically results in an extensive list of uspect network events that are then further explored manually for suspicious activity. The ability to identify anomalous network events is heavily dependent on the experience of the security personnel wading through the network log. Limitations f this approach are clear: rule-based systems only apply to exfiltration behavior that has previously been observed, and experienced cyber security personnel are rare commodities. Since the new methodology is not a discrete rule-based pproach, it is more difficult for an insider to disguise the exfiltration events. A further benefit is that the methodology provides a risk-based approach that can be implemented in a continuous, dynamic or evolutionary fashion. This permits uspect network activity to be identified early with a quantifiable risk associated with decision making when responding to suspicious activity.

99 GENERAL AND MISCELLANEOUS↗

Using EPA's Risk Assessment Tools for Superfund When Addressing Removal Actions and Late-Phase Response to Terrorist Attacks - 18228

EPA's Office of Superfund Remediation and Technology Innovation (OSRTI) has three internet based calculators, or risk assessment models, for developing risk based Preliminary Remediation Goals (PRGs) for radioactively contaminated CERCLA sites. These PRG calculators are EPA's recommended methodology for developing risk-based concentrations for remedial actions for soil and water (PRG), inside buildings (BPRG), and outside hard surfaces (SPRG). EPA has three equivalent calculators for dose assessment, which are the Dose Compliance Concentration (DCC) calculator for soil and water, inside buildings (BDCC), and outside hard surfaces (SDCC). The three PRG calculators also include default PRG tables provided for each of the calculators showing concentrations corresponding to 1 x 10-6 when the calculators are run using all of their default parameters. This presentation will provide information on how users may employ these tools beyond their original intended uses in the remedial program, to develop risk based cleanup levels during the late-phase portion of an actual response after a Radiological Dispersal Device (RDD) or Improvised Nuclear Device (IND) terrorist attack or a major accident at a Nuclear Power Plant (NPP), or a simulation during an exercise of an RDD/IND/NPP event, they may want to run the calculator using more site-specific data. This presentation will provide information on how users may employ these tools beyond their original intended uses in the remedial program, and focus on some of the more conservative default parameters that are likely candidates for replacement by site-specific information. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗