Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “retrofit design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Active Aerodynamic Load Control for Wind Turbines

The goal of this project was to develop and demonstrate an advanced dielectric barrier discharge (DBD) plasma actuator technology. We set out to demonstrate the efficacy and impact of the new actuator technology as a key component of an active load control system for wind turbines. A DBD plasma actuator consists of a thin layer of dielectric material separating a pair of offset electrodes. One of those electrodes is embedded between the dielectric layer and a non-conductive substrate, while the other is exposed to air. When driven by an appropriate high voltage waveform, the device ionizes the air near the surface of the dielectric and adjacent to the exposed electrode. Collisions between the ions in the plasma and neutral air molecules result in a wall-jet – a region of induced air velocity that can be used to modify the flow around a lifting body. Use of the device near the trailing edge of a wind turbine blade, designed in such a way as to amplify the effects of the flow-modifying device, can result in large changes to the global forces experienced by the blade. Because of the fast response time of the device, it can allow the turbine to react in real time to changes in the wind associated with turbulence, wind shear, gusts, and the like, when paired with appropriate sensors and control algorithms. The goal of this project was to increase the capacity of the device to induce velocity on its surface at the levels required by large, utility-scale wind turbines. The first technical goal was to increase the induced velocity from the current industry-best of about 4 m/s to 10 m/s by modifying the electrical waveform used to drive the device and by introducing a semi-conductive surface coating to control electrostatic charge build-up on the surface. The second goal was to use the device to modify the lift on a representative airfoil in a wind tunnel, demonstrating a reduction in lift coefficient of 0.2 or better. The third goal was to produce an actuator-induced velocity of 20 m/s. Alongside our partners at the University of Texas at Dallas, we also applied modern, advanced design methods to optimize the impact of the technology on the design of wind turbines. We also had planned to install a segmented, active load control system on a test turbine to demonstrate the ability to reduce unsteady aerodynamic forces on the turbine associated with changes in the wind. The highest induced velocity achieved during this research was 11 m/s. However, practical design constraints limited the change in lift coefficient to about 0.12 for a representative airfoil in the wind tunnel at a Reynolds number of 400,000. The primary conclusion is that the plasma actuator control authority remains insufficient for practical purposes when extrapolated to Reynolds numbers over 1 million. The potential impact of the active lift control concept was evaluated through detailed simulations for three wind turbine sizes: a 3.4MW onshore turbine, a 10MW offshore turbine, and a 15MW offshore turbine. A feedback control system was designed for each turbine within two scenarios: one where the active lift control is used as a retrofit capability on the baseline design, and the other where the designers were permitted to “upscale” the turbines in order increase annual energy production. The levelized cost of energy was then evaluated for the range of turbine sizes and design configuration. It was found that the LCOE reduction associated with active lift control fell in the range of 0.7% to 7.2%, with the highest reduction associated with upscaling the 3.4MW turbine.

17 WIND ENERGY↗

Thermal Resilience of Buildings and Communities: A Multistakeholder Review of Metrics and Approaches

Increasing temperature-related hazards require a collective effort to assess and enhance the thermal resilience of buildings and communities to protect occupants’ safety and minimize property or infrastructure damage. However, limited coordination across stakeholders and lack of standardized procedures for resilience assessment undermine the effectiveness of extreme temperature mitigation and adaptation strategies across the building life cycle. This review examines the current literature on resilience metrics to address thermal stress and risk due to extreme indoor environments. Stakeholders of thermal resilience include architects and engineers, occupants, property owners, real estate developers, urban planners, and policymakers. Additionally, motivations for measuring thermal resilience are emphasized, such as safeguarding occupant health and survivability, protecting property, and ensuring business continuity during extreme weather events. This review provides actionable insights and identifies future research needs for enhancing resilience through tailored metrics for stakeholders during the planning, design, construction, operation, and retrofitting phases of buildings and communities.

building life cycle↗

Master Services Agreement - Flexible Feeder/Distribution System Support: Cooperative Research and Development (Final Report)

PGE will engage NREL on a broad range of projects related to the integration of distributed energy resources (DERs) into the utility's operations. This portfolio of work could include projects focused on DER adoption models, advanced distribution management system (ADMS) and distributed energy management system (DERMS) design, DER dispatch strategy development, and DER valuation framework development. Additional topics could include long-term energy planning, renewable energy, energy efficiency and demand-side management. As well as technology evaluations and design guidance for building retrofits and new construction projects, energy and energy infrastructure planning, policies, and markets (and their analysis), energy storage, energy security and resilience (including energy system-related cybersecurity), transportation and mobility, technology integration analysis. Additionally, other assistance as requested by PGE consistent with NREL’s expertise.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Upper-surface modifications for C sub l max improvement of selected NASA 6-series airfoils

The thickness of the upper surface of 64 airfoils was increased from the leading edge to the position of maximum thickness. The modifications were generated using a numerical optimization routine coupled with an aerodynamic analysis code. The type of modification presented can be used for aircraft design or for the retrofit of current aircraft to improve the stall characteristics and climb performance. The coordinates of the modified airfoils are presented with plots of the forward 45% of the profiles and pressure distributions for both the modified and unmodified sections at an angle of attack of 14 degrees.

Szelazek, C. A.↗

Active magnetic bearings applied to industrial compressors

The design and shop test results are given for a high-speed eight-stage centrifugal compressor supported by active magnetic bearings. A brief summary of the basic operation of active magnetic bearings and the required rotor dynamics analysis are presented with specific attention given to design considerations for optimum rotor stability. The concerns for retrofits of magnetic bearings in existing machinery are discussed with supporting analysis of a four-stage centrifugal compressor. The current status of industrial machinery in North America using this new support system is presented and recommendations are given on design and analysis requirements for successful machinery operation of either retrofit or new design turbomachinery.

Kirk, R. G.↗

Fault-tolerant software - Experiment with the sift operating system

Results are presented of an experiment conducted in the NASA Avionics Integrated Research Laboratory (AIRLAB) to investigate the implementation of fault-tolerant software techniques on fault-tolerant computer architectures, in particular the Software Implemented Fault Tolerance (SIFT) computer. The N-version programming and recovery block techniques were implemented on a portion of the SIFT operating system. The results indicate that, to effectively implement fault-tolerant software design techniques, system requirements will be impacted and suggest that retrofitting fault-tolerant software on existing designs will be inefficient and may require system modification.

Brunelle, J. E.↗

Motel DHW Retrofit--Dallas, Texas

Solar-energy system designed to provide 65% of total domestic-hot-water (DHW) demands for 100-room motel in Dallas, Texas is subject of a report now available. System is retrofit, and storage-tank size was limited to 1,000 gallons (3,785 1) by size of room where it is located.

Source record↗

Retrofit and acceptance test of 30-cm ion thrusters

Six 30 cm mercury thrusters were modified to the J-series design and evaluated using standardized test procedures. The thruster performance meets the design objectives (lifetime objective requires verification), and documentation (drawings, etc.) for the design is completed and upgraded. The retrofit modifications are described and the test data for the modifications are presented and discussed.

Poeschel, R. L.↗

Engineering Design of a Polaris Membrane CO 2 Capture System at a Cement Plant

Sargent & Lundy (S&L) and Membrane Technology and Research, Inc. (MTR) in cooperation with CEMEX, completed an initial engineering design study to evaluate the retrofit of MTR’s membrane-based post-combustion carbon dioxide (CO 2 ) capture technology to the CEMEX Balcones cement plant (Balcones) Kiln 2. The CO 2 capture plant is designed to treat the entire flue gas flow from Kiln 2; it is estimated that this system will capture 2,039 tonnes/day per day (TPD) of CO 2 , approximately 75% of current CO 2 emissions from the kiln. The captured CO 2 is compressed to 2,213 psia (152.58 bara) before flowing to the capture plant boundary tie-point. It was assumed for this study that the CO 2 would be pumped off-site and transferred by pipeline to either a CO 2 storage complex for geological sequestration or elsewhere for Enhanced Oil Recovery (EOR).

42 ENGINEERING↗

Retrofit and verification test of a 30-cm ion thruster

Twenty modifications were found to be necessary and were approved by design review. These design modifications were incorporated in the thruster documents (drawings and procedures) to define the J series thruster. Sixteen of the design revisions were implemented in a 900 series thruster by retrofit modification. A standardized set of test procedures was formulated, and the retrofit J series thruster design was verified by test. Some difficulty was observed with the modification to the ion optics assembly, but the overall effect of the design modification satisfies the design objectives. The thruster was tested over a wide range of operating parameters to demonstrate its capabilities.

Dulgeroff, C. R.↗

Field Measurement of Central CO2 Heat Pump Water Heater for Multifamily Retrofit

Domestic hot water heating of multifamily buildings accounts for a substantial portion of the energy load of existing buildings. This load is made up of both the energy required to produce hot water and the energy needed to maintain the temperature of the heated water within a building’s distribution piping so that heat can be promptly delivered to building occupants as needed. Properly designed heat pump water heater (HPWH) systems have the ability to improve efficiency in both water heating and temperature control operations. Further, CO2 heat pump technology reflects a shift away from traditional refrigerants and toward refrigerants with low global warming potential (GWP). In this paper’s case study, a design consisting of multiple CO2 heat pump water heaters (commonly used in single-family homes) with a novel “swing tank” was proposed to meet the demand for domestic hot water heating and recirculation loop temperature maintenance. The proposed design was applied to the retrofit of a 60-unit, low-rise, multi-family building located in the Pacific Northwest of the United States. The purpose of this paper is to verify the performance of the system including the proposed “swing tank” in a centralized SHW system using CO2 HPWH. It also provides practical information and lessons learned from the retrofit project. Long-term monitoring data showed that the system had a coefficient of performance (COP) of three or greater and provided an average of 20 gallons of hot water per day per apartment. The results of this work indicate that residential-scale CO2 HPWH equipment and a “swing tank” design can efficiently provide domestic hot water heating and temperature maintenance for mid-sized multifamily buildings.

Banks, Adria↗

Multi-Level Experimental and Analytical Evaluation of Two Composite Energy Absorbers

Two composite energy absorbers were developed and evaluated at NASA Langley Research Center through multi-level testing and simulation performed under the Transport Rotorcraft Airframe Crash Testbed (TRACT) research program. A conical-shaped energy absorber, designated the conusoid, was evaluated that consisted of four layers of hybrid carbon-Kevlar plain weave fabric oriented at [+45 deg/-45 deg/-45 deg/+45 deg] with respect to the vertical, or crush, direction. A sinusoidal-shaped energy absorber, designated the sinusoid, was developed that consisted of hybrid carbon-Kevlar plain weave fabric face sheets, two layers for each face sheet oriented at +/-45deg with respect to the vertical direction and a closed-cell ELFOAM P200 polyisocyanurate (2.0-lb/cu ft) foam core. The design goal for the energy absorbers was to achieve average floor-level accelerations of between 25- and 40-g during the full-scale crash test of a retrofitted CH-46E helicopter airframe, designated TRACT 2. Variations in both designs were assessed through dynamic crush testing of component specimens. Once the designs were finalized, subfloor beams of each configuration were fabricated and retrofitted into a barrel section of a CH-46E helicopter. A vertical drop test of the barrel section was conducted onto concrete to evaluate the performance of the energy absorbers prior to retrofit into TRACT 2. The retrofitted airframe was crash tested under combined forward and vertical velocity conditions onto soil, which is characterized as a sand/clay mixture. Finite element models were developed of all test articles and simulations were performed using LS-DYNA, a commercial nonlinear explicit transient dynamic finite element code. Test-analysis results are presented for each energy absorber as comparisons of time-history responses, as well as predicted and experimental structural deformations and progressive damage under impact loading for each evaluation level.

Jackson, Karen E.↗

The Development of Two Composite Energy Absorbers for Use in a Transport Rotorcraft Airframe Crash Testbed (TRACT 2) Full-Scale Crash Test

Two composite energy absorbers were developed and evaluated at NASA Langley Research Center through multi-level testing and simulation performed under the Transport Rotorcraft Airframe Crash Testbed (TRACT) research program. A conical-shaped energy absorber, designated the conusoid, was evaluated that consisted of four layers of hybrid carbon-Kevlar plain weave fabric oriented at [+45deg/-45deg/-45deg/+45deg] with respect to the vertical direction. A sinusoidal-shaped energy absorber, designated the sinusoid, was developed that consisted of hybrid carbon-Kevlar plain weave fabric face sheets, two layers for each face sheet oriented at +/-45deg with respect to the vertical direction, and a closed-cell ELFOAM P200 polyisocyanurate (2.0-lb/cu ft) foam core. The design goal for the energy absorbers was to achieve average floor-level accelerations of between 25- and 40-g during the full-scale crash test of a retrofitted CH-46E helicopter airframe, designated TRACT 2. Variations in both designs were assessed through dynamic crush testing of component specimens. Once the designs were finalized, subfloor beams of each configuration were fabricated and retrofitted into a barrel section of a CH-46E helicopter. A vertical drop test of the barrel section was conducted onto concrete to evaluate the performance of the energy absorbers prior to retrofit into TRACT 2. The retrofitted airframe was crash tested under combined forward and vertical velocity conditions onto soft soil. Finite element models were developed of all test articles and simulations were performed using LS-DYNA, a commercial nonlinear explicit transient dynamic finite element code. Test-analysis results are presented for each energy absorber as comparisons of time-history responses, as well as predicted and experimental structural deformations and progressive damage under impact loading for each evaluation level.

Littell, Justin D.↗

Impact Testing and Simulation of a Sinusoid Foam Sandwich Energy Absorber

A sinusoidal-shaped foam sandwich energy absorber was developed and evaluated at NASA Langley Research Center through multi-level testing and simulation performed under the Transport Rotorcraft Airframe Crash Testbed (TRACT) research project. The energy absorber, designated the "sinusoid," consisted of hybrid carbon- Kevlar® plain weave fabric face sheets, two layers for each face sheet oriented at +/-45deg with respect to the vertical or crush direction, and a closed-cell ELFOAM(TradeMark) P200 polyisocyanurate (2.0-lb/ft3) foam core. The design goal for the energy absorber was to achieve an average floor-level acceleration of between 25- and 40-g during the full-scale crash test of a retrofitted CH-46E helicopter airframe, designated TRACT 2. Variations in the design were assessed through quasi-static and dynamic crush testing of component specimens. Once the design was finalized, a 5-ft-long subfloor beam was fabricated and retrofitted into a barrel section of a CH-46E helicopter. A vertical drop test of the barrel section was conducted onto concrete to evaluate the performance of the energy absorber prior to retrofit into TRACT 2. Finite element models were developed of all test articles and simulations were performed using LSDYNA ®, a commercial nonlinear explicit transient dynamic finite element code. Test analysis results are presented for the sinusoid foam sandwich energy absorber as comparisons of load-displacement and acceleration-time-history responses, as well as predicted and experimental structural deformations and progressive damage for each evaluation level (component testing through barrel section drop testing).

Jackson, Karen E.↗

Apoptosis and Self-Destruct: A Contribution to Autonomic Agents?

Autonomic Computing (AC), a self-managing systems initiative based on the biological metaphor of the autonomic nervous system, is increasingly gaining momentum as the way forward in designing reliable systems. Agent technologies have been identified as a key enabler for engineering autonomicity in systems, both in terms of retrofitting autonomicity into legacy systems and designing new systems. The AC initiative provides an opportunity to consider other biological systems and principles in seeking new design strategies. This paper reports on one such investigation; utilizing the apoptosis metaphor of biological systems to provide a dynamic health indicator signal between autonomic agents.

Sterritt, Roy↗

Dynamic Analysis of a Six-Cable Parallel Robot for Automated Panelized Building Retrofits

Cable-Driven Parallel Robots (CDPRs) are highly suitable for automated panelized building retrofits, thanks to their compact footprint and high payload-to-weight ratio. A common CDPR configuration featuring eight cables, where the anchors form a rectangular prism in front of the building facade, offers a large wrench feasible workspace and good control versatility. However, installing upper anchor points requires additional support structures, such as towers or beams, increasing setup complexity and posing logistical challenges in construction settings. To mitigate these challenges, we propose a six-cable CDPR model specifically designed for automated panelized building retrofits. Although the feasible workspace is limited, our analysis shows that the proposed CDPR adequately covers the critical areas required for panel installation. To validate that the six-cable system can effectively transport the end effector to the desired installation pose, we calculated optimal trajectories based on a constrained dynamic model. The simulation results of the six-cable CDPR demonstrate promising potential for automated panelized building retrofits, effectively balancing simplicity, cost-effectiveness, and functionality.

Liu, Yifang [ORNL] (ORCID:0000000190817417)↗

Demonstration of an Ultra-Short Channel Metal Monolith Catalytic Reactor for Trace Contaminant Control Applications

The International Space Station (ISS) Trace Contaminant Control Subassembly (TCCS) design is based upon proven, highly reliable technology. However, because its core unit operations rely upon expendable activated charcoal and an indirectly heated high temperature catalyst, annual logistics mass, crew time, and power consumption requirements are significant. To address this situation, a unique catalytic reactor design has been developed which is suitable for retrofit into the TCCS's high temperature catalytic oxidizer (HTCO) assembly. The unique design, which employs a metallic, ultra-short channel length monolith (USCM) catalyst substrate, was tested in a flight-like TCCS HTCO assembly to investigate its performance characteristics. Test results indicate that retrofitting the TCCS with a USCM-based catalytic reactor is feasible and that it may provide significant reductions in logistics mass, crew time, and power consumption. Savings indicated by test results are up to 81% for annual logistics, 56% for crew time, and 77% for startup transient duration. In addition, its demonstrated ability to operate in a power saving mode provides up to a 43% savings in average power consumption. A summary of the USCM demonstration test objectives, approach, results, and specific benefits to the TCCS's process economics are presented,

Perry, J. L↗

Expanding AirSTAR Capability for Flight Research in an Existing Avionics Design

The NASA Airborne Subscale Transport Aircraft Research (AirSTAR) project is an Unmanned Aerial Systems (UAS) test bed for experimental flight control laws and vehicle dynamics research. During its development, the test bed has gone through a number of system permutations, each meant to add functionality to the concept of operations of the system. This enabled the build-up of not only the system itself, but also the support infrastructure and processes necessary to support flight operations. These permutations were grouped into project phases and the move from Phase-III to Phase-IV was marked by a significant increase in research capability and necessary safety systems due to the integration of an Internal Pilot into the control system chain already established for the External Pilot. The major system changes in Phase-IV operations necessitated a new safety and failsafe system to properly integrate both the Internal and External Pilots and to meet acceptable project safety margins. This work involved retrofitting an existing data system into the evolved concept of operations. Moving from the first Phase-IV aircraft to the dynamically scaled aircraft further involved restructuring the system to better guard against electromagnetic interference (EMI), and the entire avionics wiring harness was redesigned in order to facilitate better maintenance and access to onboard electronics. This retrofit and harness re-design will be explored and how it integrates with the evolved Phase-IV operations.

Laughter, Sean A.↗