Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “retirement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Hearing impairment and tinnitus among older construction workers employed at DOE facilities

Few studies have defined the risk of hearing impairment and tinnitus after retirement. This report measures hearing impairment and tinnitus prevalence among older construction trades workers. The study cohort included 21,340 participants in a national medical screening program. Audiometric hearing impairment was classified according to the Global Burden of Disease Study. Tinnitus was determined by self-report. An internal subcohort of nonconstruction trades workers served as a reference group. Stratified analyses and multivariate analyses were used to measure the prevalence of hearing impairment and tinnitus by age, sex, and job category. Prevalence of any hearing impairment was 55.2% (males, 57.7%; females, 26.8%) and increased rapidly with age. Construction trades workers were 40% more likely to have hearing impairment than the reference group. The overall prevalence of tinnitus was 46.52% and followed patterns similar to hearing impairment. Workers with hearing impairment were more likely to also have tinnitus, but tinnitus was frequently reported in the absence of measured hearing impairment. Hearing impairment and tinnitus prevalence were much higher in this study than in previous research. A significant reason for the difference is that BTMed follows participants after they have retired. To draw conclusions about the risk for work-related chronic diseases and disorders it is important to monitor workers through their lifetimes. Also, tinnitus by itself should be given greater significance. We report the findings reinforce the need to promote noise reduction and hearing conservation in construction.

60 APPLIED LIFE SCIENCES↗

A U.S.-China coal power transition and the global 1.5 °C pathway

As the world seeks to increase ambition rapidly to limit global warming to 1.5 °C, joint leadership from the world's largest greenhouse gas (GHG) emitters—the United States (U.S.) and China—will be critical to deliver significant emissions reductions from their own countries as well as to catalyze increased international action. After a period of uncertainty in international climate policy, these countries now both have current leadership that supports ambitious climate action. In this context, a feasible, high-impact, and potentially globally catalytic agreement by the U.S. and China to transition away from coal to clean energy would be a major contribution toward this global effort. We undertake a plant-by-plant assessment in the power sector to identify practical coal retirement pathways for each country that are in line with national priorities and the global 1.5 °C target. Our plant-by-plant analysis shows that the 1.5 °C-compatible pathways may result in an average retirement age of 47 years for the U.S. coal plants and 22 years for Chinese coal plants, raising important questions of how to compare broader economic, employment, and social impacts. We also demonstrate that such pathways would also lead to significant emissions reductions, lowering overall global energy-related CO 2 emissions by about 9% in 2030 relative to 2020. A catalytic effect from the possibility of other countries taking compatible actions is estimated to reduce global emissions by 5.1 Gt CO 2 in 2030 and by 10.1 Gt CO 2 in 2045.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The impact of wind, solar, and other factors on the decline in wholesale power prices in the United States

Across multiple organized wholesale power markets in the United States, annual average prices declined by 19–64 dollars per MWh between 2008 and 2017 while retirements of thermal power plants accelerated. Several prominent changes over the last decade are often discussed as contributors to this decline in prices. These include growth in wind and solar, a reduction in the price of natural gas, and weakened load growth. Here we construct a fundamental supply curve model for each of seven organized wholesale market regions and use counterfactual simulations to assess the degree to which wind and solar—among other factors—have influenced wholesale electricity prices. We find that growth in wind and solar since 2008 reduced average annual wholesale electricity prices by less than 3 dollars per MWh. In contrast the decline in natural gas prices reduced wholesale prices by 7–53 dollars per MWh, depending on the region. This suggests that recent thermal-plant retirements in the U.S. are primarily due to low natural gas prices, not growth in wind and solar. Fully isolating the impact of individual factors, however, is limited by non-linear interactions between factors.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impacts of variable renewable energy on wholesale markets and generating assets in the United States: A review of expectations and evidence

Here, we synthesize available literature, data, and analysis on the degree to which growth in variable renewable energy (VRE) has impacted or might in the future impact bulk power system assets, pricing, and costs in the United States. Most studies of future scenarios indicate that VRE reduces wholesale energy prices and capacity factors of thermal generators. Traditional baseload generators are more exposed to these changing market conditions than low-capital cost and more flexible intermediate and peak-load generators. From analysis of historical data we find that VRE is already influencing the bulk power market through changes in temporal and geographic patterns areas with higher levels of VRE. The most significant observed impacts have concentrated in areas with significant VRE and/or nuclear generation along with limited transmission, with negative pricing also often occurring during periods with lower system-wide load. So far, however, VRE, has had a relatively modest impact on historical average annual wholesale prices across entire market regions, at least in comparison to other drivers. The reduction of natural gas prices is the primary contributor to the decline in wholesale prices since 2008. Similarly, VRE impacts on thermal plant retirements have been limited and there is little relationship between the location of recent retirements and VRE penetration levels. Finally, although impacts on wholesale prices have been modest so far, impacts of VRE on the electricity market will be more significant under higher VRE penetrations.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

How structural differences influence cross-model consistency: An electric sector case study

Multiple models are often employed to describe a range of possible outcomes for one or more scenarios, yielding insights into causal relationships and their uncertainties. Electric sector capacity expansion scenarios are a common topic of such efforts due to the economic influence of the electric sector, but model results typically span a broad solution space despite efforts to harmonize input assumptions, making decision implications difficult to discern. This study investigates the relationship between input harmonization and cross-model scenario consistency under disparate electric sector scenarios. We compare cross-model consistency between two state-of-the-art electric sector capacity expansion models (GCAM-USA and ReEDS) for six electric sector scenarios comprising alternate assumptions about fossil fuel resource availability, technology innovation, and long-term economy-wide transitions under four harmonization configurations varying model representations of electricity demand, fuel prices, renewable resources, and capacity retirements. These comparisons reveal that cross-model consistency can vary across scenarios under a given harmonization configuration, suggesting that harmonization efforts must often be scenario-specific if comparable cross-model consistency is desired. Model structural differences can hinder consistency, and the impact of these differences can depend on the scenario. Ultimately, thorough harmonization can reveal insights into cross-model consistency, which can be used to tighten uncertainty bounds and improve the decision-making implications of multi-model activities.

Cohen, Stuart↗

Carbon‐Neutral Pathways for the United States

Abstract The Intergovernmental Panel on Climate Change (IPCC) Special Report on Global Warming of 1.5°C points to the need for carbon neutrality by mid‐century. Achieving this in the United States in only 30 years will be challenging, and practical pathways detailing the technologies, infrastructure, costs, and tradeoffs involved are needed. Modeling the entire U.S. energy and industrial system with new analysis tools that capture synergies not represented in sector‐specific or integrated assessment models, we created multiple pathways to net zero and net negative CO 2 emissions by 2050. They met all forecast U.S. energy needs at a net cost of 0.2–1.2% of GDP in 2050, using only commercial or near‐commercial technologies, and requiring no early retirement of existing infrastructure. Pathways with constraints on consumer behavior, land use, biomass use, and technology choices (e.g., no nuclear) met the target but at higher cost. All pathways employed four basic strategies: energy efficiency, decarbonized electricity, electrification, and carbon capture. Least‐cost pathways were based on >80% wind and solar electricity plus thermal generation for reliability. A 100% renewable primary energy system was feasible but had higher cost and land use. We found multiple feasible options for supplying low‐carbon fuels for non‐electrifiable end uses in industry, freight, and aviation, which were not required in bulk until after 2035. In the next decade, the actions required in all pathways were similar: expand renewable capacity 3.5 fold, retire coal, maintain existing gas generating capacity, and increase electric vehicle and heat pump sales to >50% of market share. This study provides a playbook for carbon neutrality policy with concrete near‐term priorities.

Williams, James H.↗

Cathode regeneration and upcycling of spent LIBs: toward sustainability

‘Green ambition towards sustainability’ is one of the hot research topics of the 21st century. With the sharp steering of the energy infrastructure toward fulfilling this radical expectation, the last decade has seen a global trend toward diversified sustainable renewable energy sources (such as solar, wind, and hydroelectric power) and electrification. Lithium-ion batteries (LIBs) are playing a significant role in this energy revolution. However, with the massive scale of the production of LIBs and their eventual retirement, attention has been turned to the erratic supply of raw materials used to manufacture these batteries and their disposal. Cathode regeneration technology is likely to be an optimal solution for the disposal of waste cathodes, aimed at non-destructively repairing and straightforwardly reusing degraded cathode materials for re-manufacturing LIBs with a shortened circular process, reasonable profits, and excellent efficiency. Additionally, cathode upcycling technology, aimed at upgrading the electrochemical performance of degraded materials, can be well adapted to the upgrading of battery chemistry and show excellent flexibility and potential for transforming the LIB industry from a resource-based to a circular economy. Thus, a holistic perspective based on the complete life cycle of LIBs is encouraged, and sustainability must be at the forefront regarding battery and pack design, raw material acquisition, materials synthesis, manufacturing, operating, retiring, and recycling processes of LIBs.

25 ENERGY STORAGE↗

Utilizing grid–supportive load response to shape resilient frequency control of the power grid

The increasing penetration of renewable energy sources and the retirement of conventional generation units have decreased system inertia, making power systems more vulnerable to resilience and stability issues. To address this problem, this paper proposes a novel approach using grid-supportive loads (GSLs) to provide a fast and concise primary frequency response and a deep deterministic policy gradient agent-based secondary controller to restore the system frequency to the nominal value. The proposed method is evaluated on the single-area and multi-area test systems. The simulation results demonstrate that using GSLs enhances the power system's stability and resilience. Compared to conventional controllers, the frequency nadir is improved with GSLs. Additionally, the proposed method effectively enhances resilience even with high penetration. These findings indicate that the proposed approach can improve the resilience and stability of power systems and provide a promising solution for future power systems. The results of this study underscore the importance of utilizing innovative approaches to enhance the stability and resilience of power systems in the context of high penetration of renewable energy sources and the retirement of conventional generation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Stranded asset implications of the Paris Agreement in Latin America and the Caribbean

Achieving the Paris Agreement's near-term goals (Nationally Determined Contributions, NDCs) and long-term temperature targets could result in pre-mature retirement, or stranding, of carbon-intensive assets before the end of their useful lifetime. We use an integrated assessment model to quantify the implications of the Paris Agreement for stranded assets in Latin America and the Caribbean (LAC), a developing region with the least carbon-intensive power sector in the world. We find that meeting the Paris goals results in stranding of 37-90 billion and investment of 1.9-2.6 trillion worth of power sector capital (2021-2050) across a range of future scenarios. Strengthening the NDCs could reduce stranding costs by 27-40%. Additionally, while politically shielding power plants from pre-mature retirement or increasing the role of other sectors (e.g. land-use) could also reduce power sector stranding, such actions could make mitigation more expensive and negatively impact society. For example, we find that avoiding stranded assets in the power sector increases food prices 13%, suggesting implications for food security in LAC. Our analysis demonstrates that climate goals are relevant for investment decisions even in developing countries with low emissions.

54 ENVIRONMENTAL SCIENCES↗

Learning from Five-year Resource-Utilization Data of Titan System

Titan was the flagship supercomputer at the Oak Ridge Leadership Computing Facility (OLCF). It was deployed in late 2012, became the fastest supercomputer in the world and was retired on August 2, 2019. With Titan's mission complete, this paper provides a first-order examination of the usage of its critical resources (CPU, Memory, GPU, and I/O) over a five-year production period (2015-2019). In particular, we show quantitatively that the majority of CPU time was spent on the large-scale jobs, which is consistent with the policy of driving ground-breaking science through leadership computing. We also corroborate the general observation of the low CPU-memory usage with 95% jobs utilizing only 15% or less available memory. Additionally, we correlate the increase of total job submissions and the decrease of GPU-enabled jobs during 2016 with the GPU reliability issue which impacted the large-scale runs. We further show the surprising read/write ratio over the five-year period, which contradicts the general mindset of the large-scale simulation machines being “write-heavy”. This understanding will have potential impact on how we design our next-generation large-scale storage systems. We believe that our analyses and findings are going to be of great interest to the high-performance computing (HPC) community at large.

Wang, Feiyi↗

A Fast and Accurate Transient Stability Assessment Method Based on Deep Learning: WECC Case Study

Transient stability is one of the critical aspects of power system stability assessment. The increasing integration of inverter-based resources and the retirement of conventional synchronous generators result in the decreasing system inertia and growing complexity of system operating conditions. Using a few selected typical operating conditions cannot guarantee system transient stability in all operating conditions, and the time-domain simulation of all operating conditions requires tremendous time and is often infeasible. This paper proposes a more efficient transient stability assessment method based on deep learning. The binary search method is used to determine the critical clearing time (CCT) in creating training databased by time-domain simulation. This method is fast and accurate with 1 ms resolution. The buses whose CCTs are lower than 200 ms are considered critical buses. Buses close to each other are grouped based on their mutual admittance matrix to reduce the search space of the critical buses. This paper also proposes the generator feature normalization based on the physical model. Case study on the reduced 240-bus WECC system model demonstrates that the proposed method can predict CCT accurately and efficiently.

critical clearing time↗

The Grid Value of Ocean Current Energy in Florida

Ocean current energy technology has been proposed as a potential contributor to Florida's energy portfolio. There has been limited investigation of how this energy would be valued when integrated into the Florida electrical grid. This study assesses three future grid scenarios to evaluate the impact of adding zero-cost ocean current energy to each. The Resource Planning Model, a tool developed by the National Renewable Energy Laboratory, is used to identify the least-cost generation mix through 2050, with and without ocean current energy. The first scenario is a base case and assumes existing policies in which the addition of ocean current energy does not retire fossil-based technologies but variable generation technologies. In the second scenario, solar and storage technologies are lower cost, and the addition of ocean current generation enables those technologies along with wind to retire existing natural gas units earlier. In the third scenario, which requires a 95% reduction in carbon emissions from 2020 levels by 2050, ocean current energy can play a role in decarbonization along with other variable generation technologies. This analysis is intended to inform stakeholders on the opportunity, potential challenges, and overall value to the grid of ocean current technology from a reliability and availability focused perspective.

capacity expansion model↗

Coal Power Plant Reinvestment Visualization Tool

This tool, available at https://energycommunities.gov/coal-power-plant-reinvestment-visualization-tool/, serves as a public database and map for the purposes of enabling state and local economic development officials, project developers, and power plant owners to identify and pursue opportunities for plant and community reinvestment. The Coal Power Plant Reinvestment Visualization Tool focuses on coal power plants that have been closed or set-to-retire, alongside key infrastructure characteristics that are relevant for potential redevelopment reinvestment opportunities, including the opportunity to query these data based off pre-defined or user-set queries to identify opportunities for coal power facility reinvestment to support solar, wind, manufacturing, and nuclear. These Data for visualization and query include, but are not limited to: • Electric Transmission Lines • EPA Brownfield Sites (assessed with Federal funding) • Petroleum Terminals • Ports • Railroads • Others The tool will be updated periodically to provide relevant information to enable state and local economic development officials, project developers, and power plant owners to identify and pursue opportunities for economic revitalization and community reinvestment. Within this application data are focused on U.S. power plants with coal generation, where at least one on-site generator utilizes or utilized coal as a fuel source, including planned retirements through 2058 (EIA, 2024). Additional information on energy communities and revitalization opportunities can be accessed on the Interagency Working Group on Coal & Power Plant Communities & Economic Revitalization Energy Communities website (https://energycommunities.gov).

Closures↗

plutus: An R package to calculate electricity investments and stranded assets from the Global Change Analysis Model (GCAM)

plutus is an R package that post-processes outputs from the Global Change Analysis Model (GCAM) to calculate the power sector capital investment costs and stranded asset costs associated with GCAM projections of electricity generation by technology. GCAM is a market equilibrium model used to examine the dynamics of the coupled human-Earth system and the response of this system to global change, including socioeconomics, technology, climate, and policy. GCAM tracks electricity generation by technology and vintage over 32 geopolitical regions throughout the lifetime of each generating technology. plutus extends GCAM functionality by (1) estimating the foregone economic value of prematurely retired power plants as a result of economic-induced retirements compared to scheduled lifetimes; and (2) estimating the new installations and capital investments driven by future changes in economic, energy, agriculture, and land-use systems in GCAM.

97 MATHEMATICS AND COMPUTING↗

Behind-the-Meter Solar Accounting in Renewable Portfolio Standards

If a behind-the-meter solar photovoltaic (BTM PV) system is adopted, how does that influence the total amount of renewable electricity in its state in the long run (i.e., after the existence of the generator is reflected in the relevant utility's generation mix)? Would we expect the total amount of renewable generation to increase on a 1:1 basis with the BTM PV's generation? Or could it be something more, or something less? We show in this paper that the answer can depend on two key elements of how BTM PV is accounted for in a state’s renewable portfolio standard (RPS): (1) whether renewable energy certificates (RECs) from BTM PV can be used for RPS compliance, and (2) whether load served by generation from BTM PV counts as load covered by the RPS. These two elements combine into four possible accounting options, and we characterize the implications of each under the simplifying assumptions that the RPS is binding and the BTM PV RECs are used for compliance when allowed. For example, if load served by BTM PV generation counts toward the RPS load and BTM PV RECs cannot be used for compliance, the presence of BTM does not change the amount of RECs that the utility is required to retire, and yet additional RECs will be retired by the BTM PV owner - therefore, the total amount of renewable generation would increase on a 1:1 basis with the BTM PV generation. In contrast, under a common RPS design in which BTM PV RECs can be used for compliance and the load served by BTM PV generation is not covered by the RPS, the presence of BTM PV and transfer of RECs for compliance can actually decrease the total amount of renewable generation in the state, relative to a situation in which there is no BTM PV.

14 SOLAR ENERGY↗

Reasons to read this book (hint: it’ll help your weapons research) Q and A with author highlights Lab’s collections, importance of early weapons work

Michael Bernardin’s retirement actually looks a little more like a second career. This one, though, as an author of books. Bernardin retired last year after 35 years as a nuclear physicist that culminated with his role as the Associate Lab Director for Weapons Physics. Since then, he’s continued accessing the collections of the National Security Research Center, which is the Lab’s classified library.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Technology Strategy Assessment: Findings from Storage Innovations 2030 Thermal Energy Storage

The concept of thermal energy storage (TES) can be traced back to early 19th century, with the invention of the ice box to prevent butter from melting. Modern TES development began with building heating and cooling and concentrated solar thermal technologies for power generation in the early 1900s and late 1970s, respectively. TES systems provide many advantages compared with other long-duration energy storage (LDES) technologies, which include low costs, long operational lives, high energy density, synchronous power generation capability with inertia that inherently stabilizes the grid, and the ability to output both heat and electricity. TES Use Cases TES technologies can couple with most renewable energy systems, including wind, photovoltaic, and concentrated solar thermal energy, and can be used for heat-to-heat, heat-to-electricity, electricity-to-heat, and electricity-to-electricity (bidirectional electricity) applications. The three types of TES that have heat as an input or output are grouped together for the purposes of this report. Retrofitting retired thermal power plants can be a potential cost-effective option for TES with electricity output because they both use a similar thermal-to-electricity type of conversion. Additionally, TES can directly serve heat demand for buildings and industrial processes, displacing fossil fuels to achieve broad decarbonization. Bidirectional Electricity Figure 1 shows a bidirectional electricity TES (ETES) architecture that is emerging as a prime technology for LDES at a grid scale. The ETES technology can utilize existing TES technology infrastructures, has no geological limitations (such as mountains and water for pumped storage hydro, underground natural caverns for compressed-air energy storage, etc.), and is capable of deployment anywhere in the United States and the world for broad uses. Particularly, ETES technology can be placed at retired fossil-fueled thermal power plants to reuse decommissioned assets, protect job security in associated communities, and provide resilient and high-inertia (i.e., spinning) power to the grid. Heat Input and Output There also are many ways to integrate TES within heat-to-electricity, heat-to-heat, and electricity-to-heat applications, such as those used in concentrating solar power (CSP), buildings, district heating, and industry process heat applications. These categories can be further classified for low- and high-temperature applications. High-temperature thermal energy storage (HTTES) heat-to-electricity TES applications are currently associated with CSP deployments for power generation. TES with CSP has been deployed in the Southwestern United States with rich solar resources and has proved its value to the electric grid. Electricity-to-heat and heat-to-heat HTTES applications present great potential for decarbonizing energy-intensive industrial process heat applications [8, 9], such as iron ore processing, iron smelting, cement production, glass manufacturing, mineral processing, and chemical production. Some industrial processes require process heat at temperatures > 1,400°C, so HTTES can be utilized to reduce fuel consumption in those processes through fuel, oxidizer, and process material pre-heating. Thermal energy storage for augmenting existing industrial process heat applications makes a much more attractive economic case because the energy penalty due to thermal-to-electric conversion is eliminated. Co-located applications of power production and heat also can add to the value stacking of integrating utility-scale TES; however, these scenarios are very case specific and not practically possible in many cases. These constraints are primarily attributed to the existing infrastructure being designed, developed, and constructed for many decades around the most economically feasible technologies, such as electricity and a selection of fossil fuels for heat input. Low-temperature TES can be utilized for building and district heating and cooling, as well as some process heat applications in electricity-to-heat and heat-to-heat configurations. Lower temperature TES (LTTES) can be added to heat pump equipment (electric input), either directly interacting with the refrigerant in the condenser or evaporator, or through a secondary heat transfer fluid. It also can be integrated in the building envelope or within the ducts of the heating, ventilation, and air conditioning (HVAC) system. Cost-effective integration of TES into buildings adds significant cost, and it is one of the key barriers preventing the commercialization and deployment of TES. The optimal strategy for integrating TES with buildings has yet to be determined for various applications of TES. Nevertheless, thermal storage materials are far less costly per unit of energy stored than electricity storage materials. This means that thermal storage has the potential to reduce the cost to society of energy storage.

25 ENERGY STORAGE↗