Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “respirable”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Analysis of Air-Purifying Respirator (APR) Cartridge Performance Testing on Hanford Tanks SX-101 and SX-104 (Vol.1)

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air-purifying respirators to determine the period of time that the cartridges would provide adequate performance1 to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors exiting the headspaces of Hanford tanks SX-101 and SX-104. The Occupational Safety and Health Administration (OSHA) considers cartridge testing a valid approach for establishing cartridge change schedules.2 Testing is commonly applied in situations where mixtures of COPCs exist and where other approaches such as manufacturer recommendations and modeling are less reliable. The tests were designed and conducted to ensure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from June 16-17, 2017, and June 23-24, 2017, using headspace vapors from Hanford tank SX-104 and Hanford tank SX-101, respectively. Headspace vapors under static conditions were fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina), were assessed on separate days. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridges, and subsequently were analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Respirator Cartridge Performance Testing on a Hanford AN Tank Farm Exhauster Slipstream

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air purifying respirators to determine the period of time that the cartridges would provide adequate performance to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors exiting the exhauster at the Hanford AN tank farm. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing cartridge change schedule. Testing is commonly applied in situations where mixtures of COPCs exist and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from September 30−October 2, 2016, on a slipstream from the AN Exhauster under static conditions fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina) were assessed on separate days. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Respirator Cartridge Performance Testing on a Hanford AP Tank Farm Primary Exhauster Slipstream

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air purifying respirators (APR) to determine the period of time that the cartridges would provide adequate performance1 for APRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors exiting the exhauster for the Hanford AP tank farm. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing a cartridge change schedules. Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from June 24-26, 2016, on a slipstream from the AP exhauster fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina) were assessed on separate days. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Respirator Cartridge Performance Testing on a Hanford Tank SY-102

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air-purifying respirators (APR) to determine the period of time that the cartridges would provide adequate performance1 for APRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors emanating from the headspace of tank SY-102 on the Hanford Site. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing a cartridge change schedule. Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service life, including temperature, humidity, COPC concentration, worker breathing rate, and cartridge adsorption capacity. Testing was conducted from July 8–10, 2016, on headspace vapors from Hanford tank SY-102 under static conditions2 fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina) were assessed on separate days. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life.

42 ENGINEERING↗

Analysis of Respirator Cartridge Performance Testing on a Hanford Tank SY-102

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air-purifying respirators (APR) to determine the period of time that the cartridges would provide adequate performance for APRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors emanating from the headspace of tank SY-102 on the Hanford Site. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing a cartridge change schedule. Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service life, including temperature, humidity, COPC concentration, worker breathing rate, and cartridge adsorption capacity. Testing was conducted from July 8–10, 2016, on headspace vapors from Hanford tank SY-102 under static conditions fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina) were assessed on separate days. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Respirator Cartridge Performance Testing on the 702-AZ Primary Exhauster for the Hanford AY/AZ Tank Farms

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air purifying respirators to determine the period of time that the cartridges would provide adequate performance to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors exiting the 702-AZ primary exhauster for the Hanford AY/AZ tank farms. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing cartridge change schedules. Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from August 26–28, 2016, on a slipstream from the 702-AZ exhauster, under static conditions fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1(SCOTT Safety, Monroe, North Carolina) were assessed on separate days. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge, and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and change-out frequency.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Respirator Cartridge Performance Testing on the 702-AZ Primary Exhauster for the Hanford AY/AZ Tank Farms during a Waste-Disturbing Event

Washington River Protection Solutions (WRPS) conducted tests using two types of chemical cartridges for use in air-purifying respirators (APR) to determine the period of time that the cartridges would provide adequate performance1 for APRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors exiting the 702-AZ Primary Exhauster for the Hanford AY-AZ tank farms. Unlike prior cartridge testing on the 702-AZ Primary Exhauster, the recent tests were performed during a waste-disturbing event. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing a cartridge change schedules. Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from February 10–11, 2017, on a slipstream from the 702-AZ exhauster fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina), were assessed on separate days. Sample media (sorbent tubes) and canisters (e.g., Summa) sampling were used to collect samples of the vapor stream entering and exiting the respirator cartridge and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Influence of water flow on heterotrophic respiration of natural soils

New evidence highlights the importance of hydrology to microbial decomposition of organic matter in soils. The objective of this study was to build a reproducible and controlled capability for measuring soil respiration in the laboratory and to test the hypothesis: Soil respiration rate in a flowing system will stay higher compared to in static water. We tested replicates for flowing versus non-flowing soil water for two different soils. The water content was maintained at a consistent saturation in the flowing system but significantly desaturated in the no-flow soils over the course of a 10-day and 28-day experiment. The measured respiration had a significantly higher rate of change in the first day for one soil but after the first day and for the entire reaction for the second soil there was no measurable difference in respiration.

58 GEOSCIENCES↗

Analysis of Respirator Cartridge Performance Testing on a Hanford AW Tank Farm Exhauster Slipstream

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air-purifying respirators (APR) to determine the period of time that the cartridges would provide adequate performance for APRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors exiting the exhauster for the Hanford AW tank farm. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing a cartridge change schedules. Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service-life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from September 23-25, 2016, on a slipstream from the AW exhauster, under static conditions fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina), were assessed on separate days. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge, and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life.

54 ENVIRONMENTAL SCIENCES↗

NIST: Soil Respiration, Moisture, Temperature, Chemistry; and Fine Root Measurements from a Transect Through a Forest Edge, Gaithersburg, Maryland, 2017-2021

This dataset contains soil respiration, moisture, temperature, and chemistry, as well as fine root measurements from the National Institute of Standards and Technology (NIST) Forested Optical Reference for Evaluating Sensor Technology (FOREST) research facility at Gaithersburg, Maryland. Measurements were taken at an existing transect array that begins in a grassy meadow, crosses a sharp forest edge, then a small stream, and finally extends upwards in the interior of the forest at the top of a ridge. There are 6 different landscape positions replicated across three transects in the array. Soil respiration was measured during growing seasons in 2017-2019 (2017-06-02 to 2020-02-27). Pedons (1 m3) were isolated from surrounding tree roots using trenching and a fabric to inhibit root ingrowth. Flux measurements inside the pedons were thus assumed to represent heterotrophic only respiration in 2019, and these fluxes were paired with nearby fluxes assumed to represent total respiration. Deep vertical probes measured volumetric moisture content and temperature at the same points in the array every 10 cm in depth to either 90 cm or 120 cm total depth, at 15 minute intervals, from 2019-2021 (2019-07-09 to 2021-09-10). Soil core samples were collected from each of the array points for three different months in early- to mid-2019 (2019-03-19 to 2019-07-10), at three depths each. Soils were analyzed for gravimetric moisture content; pH; total carbon, nitrogen, and phosphorus; texture; microbial biomass carbon, nitrogen, and phosphorus; extractable dissolved organic carbon, nitrogen, and phosphorus; extractable nitrate and ammonia; and extracellular hydrolytic enzyme activities. The fine roots were separated from the cores and segregated by plant functional type (grass or tree species) and if they were dead or alive. Fine roots were then measured for length, surface area, diameter, and dry mass. This dataset contains four data files in comma separated (*.csv) format. These data serve to deepen our understanding of root and soil processes at forest edges and in transitional zones.

54 ENVIRONMENTAL SCIENCES↗

Growth and mitochondrial respiration of mungbeans (Phaseolus aureus Roxb.) germinated at low pressure

Mungbean (Phaseolus aureus Roxb.) seedlings were grown hypobarically to assess the effects of low pressure (21-24 kilopascals) on growth and mitochondrial respiration. Control seedlings grown at ambient pressure (101 kilopascals) were provided amounts of O2 equivalent to those provided experimental seedlings at reduced pressure to factor out responses to O2 concentration and to total pressure. Respiration was assayed using washed mitochondria, and was found to respond only to O2 concentration. Regardless of total pressure, seedlings grown at 2 millimoles O2 per liter had higher state 3 respiration rates and decreased percentages of alternative respiration compared to ambient (8.4 millimoles O2 per liter) controls. In contrast, seedling growth responded to total pressure but not to O2 concentration. Seedlings were significantly larger when grown under low pressure. While low O2 (2 millimoles O2 per liter) diminished growth at ambient pressure, growth at low pressure in the same oxygen concentration was enhanced. Respiratory development and growth of mungbean seedlings under low pressure is unimpaired whether oxygen or air is used as the chamber gas, and further, low pressure can improve growth under conditions of poor aeration.

Non-NASA Center↗

Throughfall-Reduction Drying Effects on Soil Respiration, Moisture, and Temperature in Four Distinct Lowland Panamanian Forests from 2015-2022

Objectives: Climatic drying is predicted for many tropical forests, yet effects on soil properties across moisture and soil gradients within tropical forests remain poorly characterized, hampering predictions of forest-climate feedbacks. We hypothesized that throughfall reduction (i.e. chronic drying) would suppress soil CO2 fluxes (i.e., respiration) in already-drier tropical forests by further reductions in soil moisture, but increases CO2 fluxes in wetter tropical forests by alleviating anaerobiosis and soil saturation. We conducted a field study in four distinct lowland Panamanian forests that vary in background rainfall and soil fertility. In each forest we constructed throughfall reduction structures that reduce moisture inputs to plots by ~50% (see methods). In drying and paired control plots we measured soil CO2 fluxes, soil moisture (volume/volume), soil temperature (°C), air temperature (°C), and forest floor biomass during wet-dry cycles (2015 – 2022). We also collected litterfall biomass and surveyed all tree species for diameter at breast height (dbh), and identified tree species in 2018 and 2019.Results:We found that soil moisture peaked in the wet season and declined in the dry season. Measured soil CO2 fluxes declined in the dry season and peaked in the early wet season ahead of peak soil moisture, resulting in a lower soil moisture optimum for respiration than previously modeled. Chronic throughfall exclusion also suppressed soil moisture across the four forests, and also initially suppressed soil CO2 fluxes across forests. There was sustained suppression of soil CO2 fluxes after four years in the wettest forest only (-28 ± 4% during the dry season), but elevated soil CO2 fluxes in a fertile forest after four years (+75 ± 28% during the late wet season). The unexpected negative drying effect in the wettest, most infertile forest could have resulted from reduced vertical flushing of nutrients into soils, as the drying effect increased with time. Including hydro-nutrient interactions in ecosystem models could improve predictions of tropical forest-climate feedbacks. Datasets included: Datasets included here include .csv and .xls files for soil respiration (carbon dioxide flux) collected using the LiCor (see methods), air temperature °C , soil moisture (vl/vl), and soil temperature °C. Soil moisture and soil temperature were collected at 0-10cm depths using hand-held probes (see methods). Data are on ~3 week timescales from 2015-2022 with some gaps. There is also a .kml file that includes coordinates for all 32 plots included in the study of four forests (n = 4 throughfall reduction and n = 4 control plots per site). No special software is needed to open these files.

54 ENVIRONMENTAL SCIENCES↗

Impact of burning on soil properties and respiration; Wood Buffalo National Park, Canada; June 2019

In this study, we used burn simulations on boreal forest soil under high and low moisture conditions to investigate the effect of burning on soil temperature, soil properties such as pH, total C and total C, and soil respiration. Location and site characteristic data of 19 sampling locations within Wood Buffalo National Park, Canada are included in "sampling-site-characteristics.csv". File "Temp-all-burns.csv" contains temperature data collected 2 to 9 cm below the soil surface during 2 min. heat treatment (i.e. burn simulation) and the following 5-24 hrs. Following the burn simulations, total respiration from burned and unburned soil was collected via KOH base traps for up to 6 months ("raw-conductivity-readings.csv"). The metadata file ("all-sample-metadata.csv") contains measurements of soil pH, total C, and total N of O horizon and underlying mineral soil as well as model fits for respiration data.

54 ENVIRONMENTAL SCIENCES↗

Models, data, and scripts associated with “Prediction of Distributed River Sediment Respiration Rates using Community-Generated Data and Machine Learning”

This data package is associated with the publication “Prediction of Distributed River Sediment Respiration Rates using Community-Generated Data and Machine Learning’’ submitted to the Journal of Geophysical Research: Machine Learning and Computation (Scheibe et al. 2024). River sediment respiration observations are expensive and labor intensive to obtain and there is no physical model for predicting this quantity. The Worldwide Hydrobiogeochemisty Observation Network for Dynamic River Systems (WHONDRS) observational data set (Goldman et al.; 2020) is used to train machine learning (ML) models to predict respiration rates at unsampled sites. This repository archives training data, ML models, predictions, and model evaluation results for the purposes of reproducibility of the results in the associated manuscript and community reuse of the ML models trained in this project. One of the key challenges in this work was to find an optimum configuration for machine learning models to work with this feature-rich (i.e. 100+ possible input variables) data set. Here, we used a two-tiered approach to managing the analysis of this complex data set: 1) a stacked ensemble of ML models that can automatically optimize hyperparameters to accelerate the process of model selection and tuning and 2) feature permutation importance to iteratively select the most important features (i.e. inputs) to the ML models. The major elements of this ML workflow are modular, portable, open, and cloud-based, thus making this implementation a potential template for other applications. This data package is associated with the GitHub repository found at Please see the file level metadata (flmd; “sl-archive-whondrs_flmd.csv”) for a list of all files contained in this data package and descriptions for each. Please see the data dictionary (dd; “sl-archive-whondrs_dd.csv”) for a list of all column headers contained within comma separated value (csv) files in this data package and descriptions for each. The GitHub repository is organized into five top-level directories: (1) “input_data” holds the training data for the ML models; (2) “ml_models” holds machine learning models trained on the data in “input_data”; (3) “scripts” contains data preprocessing and postprocessing scripts and intermediate results specific to this data set that bookend the ML workflow; (4) “examples” contains the visualization of the results in this repository including plotting scripts for the manuscript (e.g., model evaluation, FPI results) and scripts for running predictions with the ML models (i.e., reusing the trained ML models); (5) “output_data” holds the overall results of the ML model on that branch. Each trained ML model resides on its own branch in the repository; this means that inputs and outputs can be different branch-to-branch. Furthermore, depending on the number of features used to train the ML models, the preprocessing and postprocessing scripts, and their intermediate results, can also be different branch-to-branch. The “main-*” branches are meant to be starting points (i.e. trunks) for each model branch (i.e. sprouts). Please see the Branch Navigation section in the top-level README.md in the GitHub repository for more details. There is also one hidden directory “.github/workflows”. This hidden directory contains information for how to run the ML workflow as an end-to-end automated GitHub Action but it is not needed for reusing the ML models archived here. Please the top-level README.md in the GitHub repository for more details on the automation.

13C↗

Remote Sensing and GIS data at 1km-grid over Chesapeake Bay used in “He et al. 2024, Effects of spatial variability in vegetation phenology, climate, landcover, biodiversity, topography, and soil property on soil respiration across a coastal ecosystem”

The package contains the data layers used in “He et al. 2024, Effects of spatial variability in vegetation phenology, climate, landcover, biodiversity, topography, and soil property on soil respiration across a coastal ecosystem”. The study aims to use multi-source remote sensing and GIS datasets to investigate the spatial heterogeneity and identify spatial zones with similar environmental characteristics and understand the primary driving factors affecting soil respiration within sub-ecosystems of the coastal ecosystem. We employed unsupervised hierarchical clustering analysis to identify spatial regions with distinct environmental characteristics, then determined the main driving factors using Random Forest regression and SHapley Additive exPlanations (SHAP). Spatial data layers include soil respiration, kernel Normalized Difference Vegetation Index (kNDVI) computed from Harmonized Landsat 8 and Sentinel-2 time series, climate variables from the Daymet dataset, land cover, biodiversity, topographical metrics, soil property, and tidal elevation.

54 ENVIRONMENTAL SCIENCES↗

Effective antiviral coatings for deactivating SARS-CoV-2 virus on N95 respirator masks or filters

The application of antiviral coatings to masks and respirators is a potential mitigating step toward reducing viral transmission during the SARS-CoV-2 (severe acute respiratory syndrome coronavirus 2) pandemic. The use of appropriate masks, social distancing, and vaccines is the immediate solution for limiting the viral spread and protecting people from this virus. N95 respirator masks are effective in filtering the virus particles, but they cannot kill or deactivate the virus. We report a possible approach to deactivating SARS-CoV-2 by applying an antimicrobial coating (Goldshield 75) to masks and respirators, rendering them suitable for repeated use. Masks coated with Goldshield 75 demonstrated continuous inactivation of the Alpha and Beta variants of the SARS-CoV-2 over a 3-day period and no loss of inactivation when stored at temperatures at 50 °C.

36 MATERIALS SCIENCE↗

Three-Dimensional Analysis of Particle Distribution on Filter Layers inside N95 Respirators by Deep Learning

The global COVID-19 pandemic has changed many aspects of daily lives. Wearing personal protective equipment, especially respirators (face masks), has become common for both the public and medical professionals, proving to be effective in preventing spread of the virus. Nevertheless, a detailed understanding of respirator filtration-layer internal structures and their physical configurations is lacking. Here, we report three-dimensional (3D) internal analysis of N95 filtration layers via X-ray tomography. Using deep learning methods, we uncover how the distribution and diameters of fibers within these layers directly affect contaminant particle filtration. The average porosity of the filter layers is found to be 89.1%. Contaminants are more efficiently captured by denser fiber regions, with fibers <1.8 μm in diameter being particularly effective, presumably because of the stronger electric field gradient on smaller diameter fibers. This study provides critical information for further development of N95-type respirators that combine high efficiency with good breathability.

42 ENGINEERING↗

Thermal acclimation of plant photosynthesis and autotrophic respiration in a northern peatland

Peatlands contain one-third of global soil carbon (C), but the responses of peatland ecosystems to long-term warming are not well understood. Here, we pursue an emergent understanding of warming effects on ecosystem C fluxes at peatlands by constraining a process-oriented model, the terrestrial ECOsystem model, with observational data from a long-term warming experiment at the Spruce and Peatland Responses Under Changing Environments site. Model-based assessments show that ecosystem-level photosynthesis and autotrophic respiration exhibited significant thermal acclimation, with temperature sensitivities being linearly decreased with warming. Using the thermal-acclimated parameter values, simulated gross primary production, net primary production, and plant autotrophic respiration (R a ), were all lower than those simulated with non-thermal acclimated parameter values. In contrast, ecosystem respiration simulated with thermal acclimated parameter values was higher than that simulated with non-thermal acclimated parameter values. Net ecosystem CO 2 exchange was much higher after constraining model parameters with observational data from the warming treatments, releasing C at a rate of 28.3 g C m -2 yr -1 °C -1 . Our data-model integration study suggests that peatlands are likely to release more C than previously estimated. Earth system models may overestimate C uptake by peatlands under warming if physiological thermal acclimation of plants is not incorporated. Thus, it is critical to consider the long-term physiological thermal acclimation of plants in the models to better predict global C dynamics under future climate and their feedback to climate change.

54 ENVIRONMENTAL SCIENCES↗