Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “resonator temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Physisorbed Water on Silica at Mars Temperatures

The usefulness of nuclear magnetic resonance spectroscopy in probing water interactions on silica at Mars temperatures is discussed. Results indicate that two types of water occur with silica at Mars temperatures. Additional information is contained in the original extended abstract.

Sutter, B.↗

Bimaterial Thermal Compensators for WGM Resonators

Bimaterial thermal compensators have been proposed as inexpensive means of preventing (to first order) or reducing temperature-related changes in the resonance frequencies of whispering-gallery-mode (WGM) optical resonators. A bimaterial compensator would apply, to a WGM resonator, a pressure that would slightly change the shape of the resonator and thereby change its resonance frequencies. Through suitable choice of the compensator dimensions and materials, it should be possible to make the temperature dependence of the pressure-induced frequency shift equal in magnitude and opposite in sign to the temperature dependence of the frequency shift of the uncompensated resonator so that, to first order, a change in temperature would cause zero net change in frequency.

Savchenkov, Anatoliy↗

Observations and theory of Mg II lines in early type stars. II - Theory and predicted profiles. III - The observations and a comparison with the predictions

Profiles of the UV Mg II lines in the spectra of early type stars are computed in a grid of model atmospheres with effective temperatures between 8000 and 35,000 K and log g values of 2.5 to 4.0 using the LTE and non-LTE theories of line formation. The theoretical results indicate that the line cores are strengthened by non-LTE effects over the entire temperature range, resonance-line wings are weaker in the cooler models than in the LTE case, and very large deviations from LTE occur in the hot low-gravity models. These predictions are compared with the equivalent widths of the UV Mg II lines in 106 stars and of the visual lines in 48 stars (spectral types O4 to A3). The observed equivalent widths of normal stars in luminosity classes II through V are found to agree with the predictions over the entire range from O8 to A2 if a certain Mg/H abundance is adopted. The line intensities observed in supergiants, Be, Bp, and Ap stars are discussed.

Snijders, M. A. J.↗

Preliminary results from the Orbiting Solar Observatory 8 - Observations of optically thin lines

The University of Colorado spectrometer aboard OSO 8 has measured the high temperature C IV resonance lines (at 1548 and 1551 A) and the Si IV resonance lines (at 1393 and 1402 A) formed in the solar chromosphere-corona transition region. Preliminary results include studies of mean profiles, a comparison of cell and network profiles, and the behavior of the lines at the extreme solar limb.

Shine, R. A.↗

Resonance lamp absorption measurement of OH number density and temperature in expansion tube scramjet engine tests

In this paper, we report results of hydroxyl radical and static temperature measurements performed in the General Applied Science Laboratories-NASA HYPULSE expansion tube facility using the microwave resonance lamp absorption technique. Data were obtained as part of a series of hydrogen/air and hydrogen/oxygen combustion tests at stagnation enthalpies corresponding to Mach 17 flight speeds. Data from a representative injector configuration is compared to a full Navier-Stokes CFD solution.

Lempert, Walter R.↗

Surface Micromachined Silicon Carbide Accelerometers for Gas Turbine Applications

A finite-element analysis of possible silicon carbide (SIC) folded-beam, lateral-resonating accelerometers is presented. Results include stiffness coefficients, acceleration sensitivities, resonant frequency versus temperature, and proof-mass displacements due to centripetal acceleration of a blade-mounted sensor. The surface micromachined devices, which are similar to the Analog Devices Inc., (Norwood, MA) air-bag crash detector, are etched from 2-pm thick, 3C-SiC films grown at 1600 K using atmospheric pressure chemical vapor deposition (APCVD). The substrate is a 500 gm-thick, (100) silicon wafer. Polysilicon or silicon dioxide is used as a sacrificial layer. The finite element analysis includes temperature-dependent properties, shape change due to volume expansion, and thermal stress caused by differential thermal expansion of the materials. The finite-element results are compared to experimental results for a SiC device of similar, but not identical, geometry. Along with changes in mechanical design, blade-mounted sensors would require on-chip circuitry to cancel displacements due to centripetal acceleration and improve sensitivity and bandwidth. These findings may result in better accelerometer designs for this application.

DeAnna, Russell G.↗

Sub-mm Scale Fiber Guided Deep/Vacuum Ultra-Violet Optical Source for Trapped Mercury Ion Clocks

We demonstrate the functionality of a mercury capillary lamp with a diameter in the sub-mm range and deep ultraviolet (DUV)/ vacuum ultraviolet (VUV) radiation delivery via an optical fiber integrated with the capillary. DUV spectrum control is observed by varying the fabrication parameters such as buffer gas type and pressure, capillary diameter, electrical resonator design, and temperature. We also show spectroscopic data of the 199Hg+ hyper-fine transition at 40.5GHz when applying the above fiber optical design. We present efforts toward micro-plasma generation in hollow-core photonic crystal fiber with related optical design and theoretical estimations. This new approach towards a more practical DUV optical interface could benefit trapped ion clock developments for future ultra-stable frequency reference and time-keeping applications.

lamps↗

A spectral analysis of the low temperature material in spicules

The resonance lines of Na, Sr(+), and the Mg triplet system, together with the middle H Balmer lines, are used to determine the plasma parameters in the low temperature parts of spicules. Results are presented for heights of 2100 and 2500 km according to the chromospheric line emission data reported by Dunn, et al. (1968) for the 1962 eclipse. In addition to obtaining values for the electron density, this method is unique in yielding direct results for the degree of hydrogen ionization, the hydrogen density, and the line-of-sight thickness of emitting material. Temperature, microturbulence, and vertical flow velocity are more loosely determined in ranges corresponding to allowed combinations of these quantities.

Landman, D. A.↗

The 77 K operation of a multi-resonant power converter

The liquid-nitrogen temperature (77 K) operation of a 55 W, 200 kHz, 48/28 V zero-voltage switching multi-resonant dc/dc converter designed with commercially available components is reported. Upon dipping the complete converter (power and control circuits) into liquid-nitrogen, the converter performance improved as compared to the room-temperature operation. The switching frequency, resonant frequency, and the characteristic impedance did not change significantly. Accordingly, the zero-voltage switching was maintained from no-load to full-load for the specified line variations. Cryoelectronics can provide high density power converters, especially for high power applications.

Ray, Biswajit↗

An RF heated tandem mirror plasma propulsion study

Experimental results on a tandem mirror hybrid plume rocket involving a three-stage system of plasma injection, heating, and subsequent injection through a magnetic nozzle are presented. In the experiments, a plasma is created by breaking down the gas with electron cyclotron resonance heating at 2 kW in the central cell, and the ion species is then heated to high temperatures with ion cyclotron resonance heating at 10 kW in the end cell. A Langmuir probe measured an electron density of 2.5 x 10 to the 16th/cu m and a temperature of 100 eV in the central cell and an ion density of 1.25 x 10 to the 17th/cu m and a temperature of 500 eV in the end cell.

Yang, T. F.↗

Measurement of the Dielectric Constant of Seawater at L-Band: Techniques and Measurements

Satellite instruments, that will monitor salinity from space in the near future, require an accurate relationship between salinity/temperature and seawater dielectric constant. This paper will review measurements that were made of the dielectric constant of seawater during the past several years. The objective of the measurements is to determine the dependence of the dielectric constant of seawater on salinity and on temperature, more accurately than in the past. by taking advantage of modem instrumentation. The measurements of seawater permittivity have been performed as a function of salinity and temperature using a transmission resonant cavity technique. The measurements have been made in the salinity range of 10 to 38 psu and in the temperature range of IOU C to 35 C. These results will be useful in algorithm development for sensor systems such as SMOS and Aquarius. The measurement system consists of a brass microwave cavity that is resonant at 1.413 GHz. The seawater is introduced into the cavity through a capillary glass tube having an inner diameter of 0.1 mm. The diameter of the tube has been made very small so that the amount of seawater introduced in the cavity is small - thus maintaining the sensitivity of the measurements and allowing the use of perturbation theory predicting the seawater permittivity. The change in resonant frequency and the change in cavity Q can be used to determine the real and imaginary pare of the dielectric constant of seawater introduced into the slender tube. The microwave measurements are made by an HPS722D network analyzer. The cavity has been immersed in a u~ateriethylene-glycol bath which is connected to a Lauda circulator. The circulator keeps the brass cavity at a temperature constant to within 0.01 degrees. The system is automated using a Visual Basic program to control the analyzer and to collect the data. The results of the dielectric constant measurements of seawater will be presented. The measurement results will be compared with permittivity values generated from the Kline and Swift relationship. Two methods of calibration will be discussed, The errors that each technique introduces into the measurement resulls will be reviewed. Temperature stability, frequency drift and the effect of increasing cavity transmission loss on the unloaded cavity Q will also be discussed.

Lang, R.↗

Temperature Dependence of Thin Film Spiral Inductors on Alumina Over a Temperature Range of 25 to 475 C

In this paper, we present an analysis of inductors on an Alumina substrate over the temperature range of 25 to 475 C. Five sets of inductors, each set consisting of a 1.5, 2.5, 3.5, and a 4.5 turn inductor with different line width and spacing, were measured on a high temperature probe station from 10 MHz to 30 GHz. From these measured characteristics, it is shown that the inductance is nearly independent of temperature for low frequencies compared to the self resonant frequency, the parasitic capacitances are independent of temperature, and the resistance varies nearly linearly with temperature. These characteristics result in the self resonant frequency decreasing by only a few percent as the temperature is increased from 25 to 475 C, but the maximum quality factor decreases by a factor of 2 to 3. These observations based on measured data are confirmed through 2D simulations using Sonnet software.

Ponchak, George E.↗

Nonlinear Thermal Compensators for WGM Resonators

In an alternative version of a proposed bimaterial thermal compensator for a whispering-gallery-mode (WGM) optical resonator, a mechanical element having nonlinear stiffness would be added to enable stabilization of a desired resonance frequency at a suitable fixed working temperature. The previous version was described in "Bimaterial Thermal Compensators for WGM Resonators." Both versions are intended to serve as inexpensive means of preventing (to first order) or reducing temperature-related changes in resonance frequencies.

Savchenkov, Anatoliy↗

Bias and uncertainty in the absorption emission measurement of atomic sodium density in the SSME exit plane

The measurement of atomic sodium concentration in the TTB 019 firing of April 1990 is significant in that it represents the first measurement of density at the exit plane of the space shuttle main engine. The knowledge of the sodium density, combined with the certainty that the exit plane of the plume is optically thin at the sodium D-line wavelengths, provides essential information for evaluation of diagnostic techniques using sodium atoms, such as resonant Doppler velocimetry for temperature, pressure, and velocity through high resolution fluorescent lineshape analysis. The technique used for the sodium atom line transmission (SALT) measurements is that of resonant absorption emission using a hollow cathode lamp as the reference source. Through the use of two-dimensional kinetic (TDK) predictions of temperature and density for the flight engine case and radiative transfer calculations, this line-of-sight spectrally integrated transmission indicates a sodium atom concentration, i.e., mole fraction, of 0.91e-10. The subject of this paper is the assumptions and measurement uncertainties tied into the calculation. Because of the narrow shape of the source emission, the uncertainties in the absorption profile could introduce considerable bias in the measurement. The following were investigated: (1) the inclusion of hyperfine splitting of the D-lines in the calculation; (2) the use of the flight engine predictions of plume temperature and density versus those for the large throat engine; (3) the assumption of a Gaussian, i.e., Doppler, distribution for the source radiance with a temperature of 400 K; (4) the use of atomic collisional shift and width values for the work by Jongerius; and (5) a Doppler shift for a 7 degree outward velocity vector at the plume edge. Also included in the study was the bias introduced by an uncertainty in the measurement of the D1/D2 line ratio in the source.

Bauman, Leslie E.↗