Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “resonance frequency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Rapid method for computing the mechanical resonances of irregular objects

A solid object's geometry, density, and elastic moduli completely determine its spectrum of normal modes. Solving the inverse problem—determining a material's elastic moduli given a set of resonance frequencies and sample geometry—relies on the ability to compute resonance spectra accurately and efficiently. Established methods for calculating these spectra are either fast but limited to simple geometries, or are applicable to arbitrarily shaped samples at the cost of being prohibitively slow. Here, we describe a method to rapidly compute the normal modes of irregularly shaped objects using entirely open-source software. Our method's accuracy compares favorably with existing methods for simple geometries and shows a significant improvement in speed over existing methods for irregular geometries.

Acoustics↗

Light-Induced Dynamic Frequency Shifting of Microwave Photons in a Superconducting Electro-Optic Converter

Hybrid superconducting-photonic microresonators are a promising platform for realizing microwave-to-optical transduction. However, the absorption of scattered photons by the superconductors leads to unintended microwave resonance-frequency variation and line-width broadening. Here, we experimentally study the dynamics of this effect and its impact on microwave-to-optics conversion in an integrated lithium niobate–superconductor hybrid-resonator platform. Here, we unveil an adiabatic frequency shifting of the intracavity microwave photons induced by the fast photoresponses of the thin-film superconducting resonator. As a result, the temporal and spectral responses of electro-optics transduction are modified and well described by our theoretical model. This work provides insights into the light-induced conversion dynamics that must be considered in future designs of hybrid superconducting-photonic system.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Toward the Development of Molten Salt Reactor Diagnostics based on Resonantly Enhanced Laser Spectroscopy

One emerging concern within the safeguards community is how to best ensure compliance with nuclear security regulations within molten salt reactor (MSR) facilities. This problem is nontrivial as molten salts used for fuel or coolant are highly corrosive, chemically complex, and inherently require high operational temperatures. Laser spectroscopy methods such as laser-induced breakdown spectroscopy (LIBS) and laser-induced fluorescence (LIF) have previously been suggested for molten salt diagnostics due to their compatibility with liquid phase samples and potential for in-situ measurements [1]. In the former, the laser is used to ionize the sample, allowing for the characteristic light from electronic de-excitation as the resultant plasma cools to be used for material characterization. In the latter, a tunable light source is set be resonant with a specific transition, resulting in element specific excitation and the emission of fluorescence light. In our previous work [2], we demonstrated that LIF could be used for the detection of fission fragments such as Nd in solution through the separation of laser scatter and fluorescence within the time domain. Here, we present progress towards two alternate measurement schemes: LIF measurements based on spectroscopic discrimination of fluorescence emissions and resonant LIBS measurements that induce plasma using a light source set to the resonant frequency of a specific electronic transition. Both methods aim to exploit resonant excitation methods to enhance the emitted signal. The studies may provide routes for element-specific detection of constituents within complicated matrices and a means to better understand the chemical behavior of lanthanides and actinides relevant to MSRs.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL↗

Room‐Temperature Mid‐Infrared Detection Using Metasurface‐Absorber‐Integrated Phononic Crystal Oscillator

Mid-infrared (MIR) detectors find extensive applications in chemical sensing, spectroscopy, communications, biomedical diagnosis, and space exploration. Alternative to semiconductor MIR photodiodes and bolometers, mechanical-resonator-based MIR detectors show advantages in higher sensitivity and lower noise at room temperature, especially toward longer wavelength infrared. Here, uncooled room-temperature MIR detectors based on lithium niobate surface acoustic wave phononic crystal (PnC) resonators integrated with wavelength-and-polarization-selective metasurface absorber arrays are demonstrated. The detection is based on the resonant frequency shift induced by the local temperature change due to MIR absorptions. The PnC resonator is configured in an oscillating mode, enabling active readout and low-frequency noise. The 1-GHz oscillator-based MIR detector shows a relative frequency deviation of 5.24 × 10 −10 Hz −1/2 at an integration time of 50 µs, leading to an incident noise equivalent power of 197 pW Hz −1/2 when input 6-µm MIR light is modulated at 1.8 kHz, and a large dynamic range of 10 7 in incident MIR power. The device architecture is compatible with the scalable manufacturing process and can be readily extended to a broader spectral range by tailoring the absorbing wavelengths of metasurface absorbers.

Xi, Zichen [Virginia Polytechnic Inst. and State U↗

Results from the Alfven Eigenmode Active Diagnostic during the 2019-2020 JET deuterium campaign

This paper presents results of extensive analysis of mode excitation observed during the operation of the Alfven Eigenmode Active Diagnostic (AEAD) in the JET tokamak during the 2019-2020 deuterium campaign. Six of eight toroidally spaced antennas, each with independent power and phasing, were successful in actively exciting stable MHD modes in 479 plasmas. In total, 4768 magnetic resonances were detected with up to fourteen fast magnetic probes. In this work, we present the calculations of resonant frequencies f0, damping rates \gamma < 0, and toroidal mode numbers n, spanning the parameter range f0 = 30 - 250 kHz, -\gamma = 0 - 13 kHz, and |n| < 30. In general, good agreement is seen between the resonant and the calculated toroidal Alfven Eigenmode frequencies, and between the toroidal mode numbers applied by the AEAD and estimated of the excited resonances. We note several trends in the database: the probability of resonance detection decreases with plasma current and external heating power; the normalized damping rate increases with edge safety factor but decreases with external heating. These results provide key information to prepare future experimental campaigns and to better understand the physics of excitation and damping of Alfven Eigenmodes in the presence of alpha particles during the upcoming DT campaign, thereby extrapolating with confidence to future tokamaks.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Results from the Alfvén Eigenmode Active Diagnostic during the 2019-2020 JET deuterium campaign

This paper presents results of extensive analysis of mode excitation observed during the operation of the Alfvén Eigenmode Active Diagnostic (AEAD) in the JET tokamak during the 2019-2020 deuterium campaign. Here, six of eight toroidally spaced antennas, each with independent power and phasing, were successful in actively exciting stable MHD modes in 479 plasmas. In total, magnetic resonances were detected with up to fourteen fast magnetic probes. In this work, we present the calculations of resonant frequencies $f_0$, damping rates γ < 0, and toroidal mode numbers $\textit{n}$, spanning the parameter ranges $f_0$ ≈ 30–250 kHz, –γ ≈ 0–13 kHz, and $\vert n \vert \leq {30}$. In general, good agreement is seen between the resonant and the calculated toroidal Alfvén Eigenmode frequencies, and between the toroidal mode numbers applied by the AEAD and estimated of the excited resonances. We note several trends in the database: the probability of resonance detection decreases with plasma current and external heating power; the normalized damping rate increases with edge safety factor but decreases with external heating. These results provide key information to prepare future experimental campaigns and to better understand the physics of excitation and damping of Alfvén Eigenmodes in the presence of alpha particles during the upcoming DT campaign, thereby extrapolating with confidence to future tokamaks.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Growth and Saturation of the Electron Drift Instability in a Crossed Field Plasma

The linear growth and nonlinear energy transfer of the electron drift instability (EDI) are experimentally measured in the plume of a low-temperature, Hall effect discharge. A frequency-based bispectral analysis technique applied to fast ion density fluctuation measurements shows a growth rate function that is qualitatively similar to predictions from the linear instability dispersion relation, but an order of magnitude smaller. Calculation of the nonlinear transfer function indicates multiple three-wave interactions between high-frequency resonances of the instability in addition to an inverse energy cascade toward lower-frequency modes. Furthermore, these results are discussed in the context of recent theoretical, numerical, and experimental efforts on the EDI in Hall effect discharges and how the EDI may impact anomalous cross field transport.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental studies of plasma-antenna coupling with the JET Alfvén Eigenmode Active Diagnostic

Here, this paper presents a dedicated study of plasma-antenna (PA) coupling with the Alfvén Eigenmode Active Diagnostic (AEAD) in JET. Stable AEs and their resonant frequencies f, damping rates γ < 0, and toroidal mode numbers n are measured for various PA separations and limiter versus X-point magnetic configurations. Two stable AEs are observed to be resonantly excited at distinct low and high frequencies in limiter plasmas. The values of f and n do not vary with PA separation. However, |γ| increases with PA separation for the low-f, but not high-f, mode, yet this may be due to slightly different edge conditions. The high-f AE is detected throughout the transition from limiter to X-point configuration, though its damping rate increases; the low-f mode, on the other hand, becomes unidentifiable. The linear, resistive MHD code CASTOR is used to simulate the frequency scan of an AEAD-like external antenna. For the limiter pulses, the high-f mode is determined to be an n = 0 GAE, while the low-f mode is likely an n = 2 TAE. During the transition from limiter to X-point configuration, CASTOR indicates that n = 1 and 2 EAEs are excited in the edge gap. These results extend previous experimental studies in JET and Alcator C-Mod; validate the computational work performed by Dvornova et al; and provide guidance for the optimization of PA coupling in upcoming JET energetic particle experiments, for which the AEAD will aim to identify the contribution of alpha particles to AE drive during the DT campaign.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental studies of plasma-antenna coupling with the JET Alfven Eigenmode Active Diagnostic

This paper presents a dedicated study of plasma-antenna (PA) coupling with the Alfven Eigenmode Active Diagnostic (AEAD) in JET. Stable AEs and their resonant frequencies f, damping rates gamma < 0, and toroidal mode numbers n are measured for various PA separations and limiter versus X-point magnetic configurations. Two stable AEs are observed to be resonantly excited at distinct low and high frequencies in limiter plasmas. The values of f and n do not vary with PA separation. However, |gamma| increases with PA separation for the low-f, but not high-f, mode, yet this may be due to slightly different edge conditions. The high-f AE is detected throughout the transition from limiter to X-point configuration, though its damping rate increases; the low-f mode, on the other hand, becomes unidentifiable. The linear resistive MHD code CASTOR is used to simulate the frequency scan of an AEAD-like external antenna. For the limiter pulses, the high-f mode is determined to be an n = 0 GAE, while the low-f mode is likely an n = 2 TAE. During the transition from limiter to X-point configuration, CASTOR indicates that n = 1 and 2 EAEs are excited in the edge gap. These results extend previous experimental studies in JET and Alcator C-Mod; validate the computational work performed by Dvornova et al 2020 Phys. Plasmas 27 012507; and provide guidance for the optimization of PA coupling in upcoming JET energetic particle experiments, for which the AEAD will aim to identify the contribution of alpha particles to AE drive during the DT campaign.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Current-induced dynamics and tunable spectra of a magnetic chiral bobber

Chiral bobber (ChB) is an exotic three-dimensional topological texture in chiral magnets. It is composed of a Bloch-point singularity and a skyrmion tube; the incommensurate characteristic length scales of these two components would thus lead to novel dynamics of a ChB. In this work, we report the current-induced motion and the accompanying Hall effect of a ChB. Surprisingly, we find that the Hall angle of a ChB can be tuned in a wide range from -90 ° to positive angles. A further study of spin-wave excitations identified high-frequency resonant modes, which are related to the velocity of ChB and lattice constants. The excited frequency can be two orders of magnitude higher than that of skyrmions. The broad ranges of Hall angles and frequency spectra could boost the development of spintronic devices using topological textures.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Study of Microphonic Effects on the C100 Cryomodule for High Energy Electron Beam Accelerators

The Continuous Electron Beam Accelerator Facility (CEBAF) at Thomas Jefferson National Laboratory (JLab) is a particle accelerator which can accelerate an electron beam to relativistic speeds and apply the beam onto target samples. The C100 superconducting radio frequency (SRF) cavity is the primary accelerating structure of the C100 cryomodule, one of the many cryomodules which compose the CEBAF linear accelerator. SRF cavities are particularly sensitive to internal and external vibrations that can result in a phenomenon called microphonics which degrade the operational stability of a cryomodule. The purpose of this thesis is to investigate the significance of mechanical disturbances on the electromagnetic resonant frequency of a C100 SRF cavity. Knowledge of the mechanical resonance of the cavities and cryomodule sheds light into how these disturbances are most easily realized as deformation which causes radio frequency (RF) detuning. Three studies were conducted: the development and hammer test calibration of a Finite Element Analysis (FEA) model of a C100 cavity, the development and hammer test calibration of an FEA model of a C100 cavity string, and the hammer test of the C100-10R cryomodule at the Cryomodule Test Facility (CMTF). The cavity FEA model was found to accurately predict two modes found in two real cavities in a simply supported configuration. The cavity string FEA model leveraged the calibrated cavity FEA model but was not found to accurately predict the modal behavior of a real cavity string. Even so, the modal behavior of the cavity string inside the C100-10R cryomodule was captured during a hammer test while it was partially assembled. Finally, the C100-10R cryomodule was placed in the CMTF to study RF detuning. The RF detuning spectra during hammer hits and background noise was captured. The results of the hammer testing indicate two strong peaks at low frequencies (9-10 Hz and 22-23 Hz). These two frequencies were found to be nearly coincident to four instances of mechanical resonance found during the hammer testing done on the partially-assembled C100-10R. Because of this, these two modes are believed to contribute to RF detuning of the cryomodule. This test event also included the testing of the effectiveness of a configuration of BNNT canisters designed to act as dampers. While these tests show promising results, the lurking variables render these tests somewhat inconclusive.

Hull, Caleb James↗

Remote quantum state transfer for qubits with different frequencies

A quantum communication system includes a first quantum transceiver, a second quantum transceiver, and a quantum communication mediator (QCM) system. The transceivers have different resonant frequencies or physical systems. The QCM system receives an initial quantum signal from the first quantum transceiver. The QCM system transfers a quantum state of the initial quantum signal to a first mechanical signal and then from the first mechanical signal to a first pair of optical signals by way of a first three-wave mixing process. The QCM transfers the quantum state to a second pair of optical signals from the first pair by way of a four-wave mixing process. The QCM transfers the quantum state from the second pair of optical signals to a second mechanical signal by way of a second three-wave mixing process. The QCM transfers the quantum state from the second mechanical signal to a final quantum signal by mechanical transduction.

Soh, Daniel Beom Soo↗

VTS Dynamic Model and Experimental Validation for Vibration Suppression

High Q-factor superconducting radio-frequency (SRF) cavities are extremely sensitive to mechanical vibrations, which can cause an uncontrolled shift of the electromagnetic resonance frequency, with detrimental effects on the cavity performance. To avoid this phenomenon (i.e. microphonics) the dynamic behavior of the assembly must be studied, to design vibration suppression systems. In this paper, the numerical model of the Vertical Test Stand (VTS) insert adopted at the Fermi National Accelerator Laboratory for cold tests was studied, in the framework of the experimental characterization of Dark SRF cavities conducted by the SQMS (Superconducting Quantum Materials and Systems) center. Due to the complexity of the assembly, experimental activity is of utmost importance to validate the model. Thus, vibration testing was performed on the actual system, and a good correlation between numerical and experimental results was found. Additionally, two different setups were compared, with and without implementing a preliminary passive vibration suppression system, to assess its effectiveness in reducing the microphonics phenomenon. The obtained results allowed for the design of an improved isolation system, which will be the subject of future experimental testing.

43 PARTICLE ACCELERATORS↗

AMAROK: A Radio Frequency Development Platform for High-Power, Full-Scale Positive Ion Sources for DIII-D Neutral Beam Injectors

Next-generation neutral beam injection (NBI) systems demand RF ion sources capable of efficiently coupling >120 kW at 2–4-MHz frequencies, yet existing designs face voltage standoff and impedance-matching challenges. To address this, the advanced multicoil antenna for RF operations at kilowatts (AMAROK) was developed as a high-power RF inductively coupled plasma (ICP) source delivering up to 200 kW in the 2–4-MHz range via four phase-controlled generators for flexible power sharing. Two antenna designs—a single-strap multiturn (MT) and a multistrap single-turn (ST) design—were evaluated to optimize resonance, impedance matching, and power coupling across plasma loads. Here, a semi-analytical self-resonant frequency (SRF) model, validated experimentally, predicts resonance trends for arbitrary turn counts and tubing diameters, enabling rapid antenna optimization. Strap-to-strap mutual inductance in the ST configuration showed strong spatial dependence, guiding generator operation and total load inductance. These insights informed a custom π -topology matching network, achieving stable impedance matching over a wide range of plasma-driven loads. Collectively, these results position AMAROK as a versatile testbed for advancing high-power RF source technology in fusion NBI applications.

DIII-D↗

Disruption halo current rotation scaling on Alcator C-Mod and HBT-EP

Asymmetric halo currents (HCs) can exert large net forces on the vacuum vessel and other components during disruptions on tokamaks. The displacements caused by these forces can then be amplified if these asymmetric forces rotate at frequencies resonant with the vessel. This paper reports on the investigation of a recently proposed scaling law for the disruption HC rotation frequency [Saperstein et al., “Halo current rotation scaling in post-disruption plasmas,” Nucl. Fusion 62, 026044 (2022)] that combines measurements on Alcator C-Mod with those on HBT-EP. We find that a new non-circular version of the scaling law [ ⟨ f rot ⟩ m / ⟨ m ⟩ ∝ 1 B T ( S / π )] takes into consideration the dependence of frot on the poloidal structure of the MHD instability (m) driving the asymmetry and describes the disruption-averaged rotation frequency on C-Mod. Disruption rotation is also found to be insensitive to the vertical position and impurity content of the plasma at the onset of the disruption. However, a stagnation in the time evolution of frot is occasionally observed. In conclusion, observations are consistent with the dominance of poloidal rotation during the disruption, which is motivated by the poloidal drift nature of the scaling law.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

TLS characterization using multilevel decay of a fixed-frequency transmon

Transmon qubits are a cornerstone of superconducting quantum computing platforms, yet their coherence times often exhibit temporal fluctuations that degrade processor performance. These variations are commonly attributed to shifts in the resonance frequencies of individual two-level systems (TLSs) near the qubit transition. In this study, we monitor the lifetimes of multiple energy levels of a fixed-frequency transmon and examine their temporal correlations. Our measurements reveal that one or more TLSs—detuned by more than 100 MHz from the qubit transition—can still significantly influence coherence. The proposed method provides a powerful tool for TLS spectroscopy without the need to tune the transmon frequency, either via a flux-tunable inductor or AC-Stark shifts.

Roy, Tanay [Fermilab] (ORCID:000000019442862X)↗

TLS characterization using multilevel decay of a fixed-frequency transmon

Transmon qubits are a cornerstone of superconducting quantum computing platforms, yet their coherence times often exhibit temporal fluctuations that degrade processor performance. These variations are commonly attributed to shifts in the resonance frequencies of individual two-level systems (TLSs) near the qubit transition. In this study, we monitor the lifetimes of multiple energy levels of a fixed-frequency transmon and examine their temporal correlations. Our measurements reveal that one or more TLSs—detuned by more than 100 MHz from the qubit transition—can still significantly influence coherence. The proposed method provides a powerful tool for TLS spectroscopy without the need to tune the transmon frequency, either via a flux-tunable inductor or AC-Stark shifts.

Roy, Tanay [Fermilab] (ORCID:000000019442862X)↗

Capacitor Design for Self-Resonant Coils for Long-Distance Wireless Power Transfer System

In this paper, an integrated capacitor design is proposed for higher-order resonant tank topologies for self-resonant coils, such as series, parallel, LCC, LLC, etc. The capacitor is one of the large, lossy, and thermally vulnerable components of a high-frequency resonant tank, and designing a high-voltage, thermally stable resonant capacitor can be highly challenging. Designing the extremely high-voltage capacitor as an integral part of the coil reduces the size and complexity of the coil assembly. This paper proposes a low-loss PCB-based high-voltage capacitor design to achieve that target, which can be implemented as an integral part of the coil. The proposed capacitor designs are simulated using Multiphysics FEA and tested experimentally. A 23 kV, 133 pF capacitor prototype was built and tested as part of a 1 kW long-distance wireless charging system. The test results verify the capacitor’s voltage, current, and thermal resiliency performance.

Mohammad, Mostak [ORNL] (ORCID:0000000256388783)↗