Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

A Ce-Doped LiI Scintillator Film-Based High Rate, High Spatial Resolution Neutron Anger Camera for Neutron Scattering Facilities

The 2-D position sensitive neutron detectors featuring a significantly improved count rate capacity and a sub-mm spatial resolution are in high demand by neutron scattering facilities, especially the next generation high-flux spallation neutron sources (SNSs). They are anticipated to play a crucial role in fully utilizing the unprecedentedly high neutron brightness offered by these sources. In this work, a high rate and high spatial resolution neutron Anger camera has been successfully developed based on a Ce-doped microcolumnar LiI scintillator film and the PETsys TOFPET2 ASIC readout electronics. The performance evaluation was conducted in a standard laboratory environment as well as the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL) with regard to light yield, γ-ray sensitivity, neutron detection efficiency, count rate capability, spatial resolution, and position linearity. The LiI:Ce scintillator was found to have a higher light yield and a lower γ-ray sensitivity than GS20 (i.e., 11729 versus 6000 photons/n and 1.67 × 10 −5 versus on the order of 10 −4 ). The neutron detection efficiency was measured to be 63% at 4.2 Å. This camera demonstrated an exceptional count rate capability, up to at least 481 kHz without rate loss. The spatial resolution was as good as 0.47 mm. Here, the position linearity was also enhanced.

High rate↗

Global Multimodal Dataset for Nighttime Light Super-Resolution

The dataset is a collection of spatially and temporally registered high-resolution and low-resolution nighttime light (NTL) images, high-resolution land-use binary masks, and high-resolution road density images from around the world. The NTL images are sourced from the NASA Black Marble product VNP46A2 and the LuoJia1-01 satellite. The land-use binary masks are derived from Google's and the World Resources Institute's DynamicWorld dataset, and the road density images are sourced from OpenStreetMap.

Nighttime lights↗

High-Resolution WRF-Based Downscaling of Earth System Model Projections for Energy Applications across CONUS

Evaluating energy resources under future scenarios requires meteorological information that adequately resolves regional-scale variability and is suitable for regional energy system studies. Although Earth system model (ESM) outputs provide essential large-scale context, their coarse resolution and inherent biases limit direct use in energy system applications. This work presents a high-resolution dynamical downscaling framework using the Weather Research and Forecasting (WRF) model to generate energy-relevant regional fields for future scenarios over the contiguous United States (CONUS). The framework first identifies an optimal WRF configuration through sensitivity experiments, then evaluates raw and bias-corrected ESM initial and boundary conditions, with soil moisture and soil temperature bias correction implemented as an integral component of the bias-corrected ESM atmospheric forcing prior to WRF dynamical downscaling to improve land-atmosphere interactions. Simulations performed at 4-km resolution show that uncorrected ESM forcing leads to systematically dry and cold soil states, which propagate into elevated near-surface air temperature and solar irradiance biases, particularly during summer for the period 2000-2014. Incorporating bias-corrected atmospheric forcing together with soil state bias correction substantially reduces these errors and improves the representation of surface energy processes in WRF simulations. The results highlight the importance of bias-aware initialization strategies in high-resolution dynamical downscaling for future energy system analysis and planning.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High-resolution ion mobility based on traveling wave structures for lossless ion manipulation resolves hidden lipid features

Abstract High-resolution ion mobility (resolving power > 200) coupled with mass spectrometry (MS) is a powerful analytical tool for resolving isobars and isomers in complex samples. High-resolution ion mobility is capable of discerning additional structurally distinct features, which are not observed with conventional resolving power ion mobility (IM, resolving power ~ 50) techniques such as traveling wave IM and drift tube ion mobility (DTIM). DTIM in particular is considered to be the “gold standard” IM technique since collision cross section (CCS) values are directly obtained through a first-principles relationship, whereas traveling wave IM techniques require an additional calibration strategy to determine accurate CCS values. In this study, we aim to evaluate the separation capabilities of a traveling wave ion mobility structures for lossless ion manipulation platform integrated with mass spectrometry analysis (SLIM IM-MS) for both lipid isomer standards and complex lipid samples. A cross-platform investigation of seven subclass-specific lipid extracts examined by both DTIM-MS and SLIM IM-MS showed additional features were observed for all lipid extracts when examined under high resolving power IM conditions, with the number of CCS-aligned features that resolve into additional peaks from DTIM-MS to SLIM IM-MS analysis varying between 5 and 50%, depending on the specific lipid sub-class investigated. Lipid CCS values are obtained from SLIM IM ( TW(SLIM) CCS) through a two-step calibration procedure to align these measurements to within 2% average bias to reference values obtained via DTIM ( DT CCS). A total of 225 lipid features from seven lipid extracts are subsequently identified in the high resolving power IM analysis by a combination of accurate mass-to-charge, CCS, retention time, and linear mobility-mass correlations to curate a high-resolution IM lipid structural atlas. These results emphasize the high isomeric complexity present in lipidomic samples and underscore the need for multiple analytical stages of separation operated at high resolution. Graphical abstract

Reardon, Allison R. (ORCID:0000000165830134)↗

Estimating soybean yields from high-temporal-resolution multi-source data using deep learning

Accurate and timely crop yield prediction is crucial for ensuring food security and maintaining stable agricultural markets. In recent years, there has been a surge in interest in leveraging high-temporal-resolution, multi-source data for effective crop growth monitoring and yield estimation. A notable challenge arises from the difficulty in capturing the intricate interactions between variables across different time steps within these high-temporal-resolution time series datasets. This complexity hinders the reliable extraction of yield information from voluminous and often noisy datasets, especially during periods of extreme weather events. Here, in this study, we propose an Attention and Graph Isomorphism Network-enhanced Bi-directional Long Short-Term Memory network (AGB-LSTM) for estimating county-level soybean yield in the United States. This model integrates a diverse set of remote sensing data, including Near-Infrared Reflectance of Vegetation (NIRv), Sun-Induced chlorophyll Fluorescence (SIF), and Gross Primary Productivity (GPP), along with environmental covariates. The AGB-LSTM effectively leverages information related to crop yield from high-temporal-resolution time series data (5-days), achieving an accuracy of R²= 0.67 and rRMSE = 14.46%. This approach significantly outperforms traditional machine learning methods such as Random Forest (RF) (R²= 0.52, rRMSE = 17.36%) and Bi-LSTM (R²= 0.58, rRMSE = 16.17%). Sensitivity experiments with different time steps and ranges demonstrated that our model could accurately and stably predict yields 1 to 2 months before harvest. Moreover, data with a finer temporal resolution consistently improved prediction performance, resulting in an approximately 20% increase in and an approximately 20% decrease in rRMSE compared to using monthly composites. We also evaluated the robustness of the model under extreme climate events and observed strong performance (R²= 0.50, rRMSE = 21.32%). Finally, yield mapping for major soybean-producing regions in North America in 2023 revealed spatial patterns that closely matched USDA yield reports. Our findings suggest that the AGB-LSTM model is a promising and effective method for estimating yield and has notable potential for global crop yield forecasting.

Deep learning↗

High-resolution modeling of indoor radon exposure with uncertainty quantification in Utah

Indoor radon accounts for 37% of population-level exposure to ionizing radiation in the United States. However, radon metrics are typically reported at coarse spatial scales, potentially obscuring meaningful local variation. We developed a high-resolution modeling framework to estimate indoor radon concentrations across Utah while explicitly quantifying predictive uncertainty. A total of 19,497 residential radon measurements collected between 2006 and 2017 were combined with environmental and housing characteristics and analyzed using a geospatial neural network that accommodates spatial dependence and nonlinear associations. Predictions were generated on a uniform hexagonal grid at 0.73 km2 resolution (H3 level 8). Out-of-sample predictions aggregated to the H3 level 8 grid showed good agreement with observed concentrations (Pearson r=0.64), while household-level predictions exhibited more moderate agreement (r=0.45). The model produced well-calibrated uncertainty estimates, with 24.1% of held-out observations exceeding the predicted 75th-percentile threshold. Maps of predicted radon concentrations and the probability of exceeding the U.S. EPA action level of 148 Bq/m3 (4 pCi/L) revealed substantial fine-scale spatial heterogeneity that was not apparent in conventional coarse-resolution summaries, with greater local variability observed in densely monitored urban counties than in sparsely sampled regions. High-resolution radon models that explicitly quantify uncertainty provide a useful framework for characterizing the spatial distribution of indoor radon and identifying areas of elevated exceedance risk. These findings highlight the value of fine-scale monitoring data and uncertainty-aware modeling approaches for radon exposure assessment, environmental risk characterization, and radon-related health research.

Wu, Yunhan [ORNL] (ORCID:0000000178842994)↗

The NanoSIMS-HR: The Next Generation of High Spatial Resolution Dynamic SIMS

The high lateral resolution and sensitivity of the NanoSIMS 50 and 50L series of dynamic SIMS instruments have enabled numerous scientific advances over the past 25 years. Here, in this study, we report on the NanoSIMS-HR, the first major upgrade to the series, and analytical tests in a suite of sample types, including an aluminum sample containing silicon crystals, microalgae, and plant roots colonized with a symbiotic fungus. Significant improvements have been made in the Cs + ion source, high voltage (HV) control, stage reproducibility, and other aspects of the instrument that affect performance. The modified design of the NanoSIMS-HR thermal-ionization Cs + source enables a 5 pA primary ion beam to be focused into a 100 nm spot, a ~2.5-fold increase compared to Cs + sources on previous instruments (~2 pA at 100 nm). The brightness of the new Cs + source enables an ultimate lateral resolution as high as 30 nm and improved detection limits for a given analysis area. Sample stage movement accuracy is higher than 500 nm, enabling many-fold higher throughput automated analyses. With the new HV control, the primary ion beam impact energy can be reduced from 16 to 2 keV, which enables higher depth resolution during depth profiling (a 2-fold improvement), albeit with a 5-fold decrease in lateral resolution. In the NanoSIMS-HR, the secondary ion column and detection system are identical to those used in the previous series, and the isotopic analysis performance is as precise as in previous NanoSIMS instruments.

54 ENVIRONMENTAL SCIENCES↗

Impacts of Resolution on Heavy‐Precipitating Storms in Climate Model Hindcasts

The present study investigates the impact of horizontal resolutions on heavy‐precipitating storms using the Energy Exascale Earth System Model version2 (E3SMv2) at low (∼100 km, LR) and high (∼25 km, HR) resolutions through short‐range hindcasts. The short‐range hindcast approach ensures a faithful comparison of model resolution in simulating the same storm events under a controlled large‐scale environment. Using a phenomenon‐based framework, we attribute precipitation to specific storm types: tropical cyclones (TCs), extratropical cyclones, atmospheric rivers, and mesoscale convective systems (MCSs). Our findings show that E3SM hindcasts with both HR and LR configurations significantly underestimate storm‐associated precipitation intensity but overestimate precipitation from other sources. Furthermore, both HR and LR hindcasts face significant challenges in accurately simulating extreme precipitation events, particularly over MCS hotspots. Nevertheless, HR simulations capture more detailed and intense precipitation patterns with an improved representation of storm dynamics. HR hindcasts produce 16% more storm precipitation compared to LR. For precipitation extremes, HR simulates a 33% higher 99th percentile precipitation magnitudes compared to LR, and most of the increment comes from these four heavy‐precipitating storm types. The increase in precipitation mainly comes from stratiform precipitation rather than convective precipitation. The improvement in HR simulations varies across different storm types with TC showing the largest improvement. The phenomenon‐based approach provides important insights into precipitation simulations especially for extremes. Our results emphasize the need for further refinement in high‐resolution models to improve the accuracy of precipitation predictions, which is crucial for better understanding and mitigating climate change impacts.

54 ENVIRONMENTAL SCIENCES↗

Remotely Sensed High‐Resolution Soil Moisture and Evapotranspiration: Bridging the Gap Between Science and Society

This paper reviews the current state of high‐resolution remotely sensed soil moisture (SM) and evapotranspiration (ET) products and modeling, and the coupling relationship between SM and ET. SM downscaling approaches for satellite passive microwave products leverage advances in artificial intelligence and high‐resolution remote sensing using visible, near‐infrared, thermal‐infrared, and synthetic aperture radar sensors. Remotely sensed ET continues to advance in spatiotemporal resolutions from MODIS to ECOSTRESS to Hydrosat and beyond. These advances enable a new understanding of bio‐geo‐physical controls and coupled feedback mechanisms between SM and ET reflecting the land cover and land use at field scale (3–30 m, daily). Still, the state‐of‐the‐science products have their challenges and limitations, which we detail across data, retrieval algorithms, and applications. We describe the roles of these data in advancing 10 application areas: drought assessment, food security, precision agriculture, soil salinization, wildfire modeling, dust monitoring, flood forecasting, urban water, energy, and ecosystem management, ecohydrology, and biodiversity conservation. We discuss that future scientific advancement should focus on developing open‐access, high‐resolution (3–30 m), sub‐daily SM and ET products, enabling the evaluation of hydrological processes at finer scales and revolutionizing the societal applications in data‐limited regions of the world, especially the Global South for socio‐economic development.

54 ENVIRONMENTAL SCIENCES↗

Molecular-resolution imaging of ice crystallized from liquid water by cryogenic liquid-cell TEM

Despite the ubiquity of ice, a molecular-resolution image of nanoscopic defects or microstructures in ice crystallized from liquid water has never been obtained. This is mainly due to the difficulties in preparing and preserving crystalline ice samples that can survive under high-resolution imaging conditions. Here, we report the stabilization and Å-resolution electron imaging of ice Ih crystallized from liquid water by developing cryogenic liquid-cell transmission electron microscopy (CRYOLIC-TEM). We combine lattice mapping with molecular dynamics simulations to reveal that ice formation is highly tolerant to nanoscale defects such as misoriented subdomains and trapped gas bubbles, which are stabilized by molecular-scale structural motifs. Importantly, bubble surfaces adopt low-energy nanofacets and create negligible strain fields in the surrounding crystal. These bubbles can dynamically nucleate, grow, migrate, dissolve, and coalesce under electron irradiation and be monitored in situ near a steady state. This work improves our understanding of water crystallization behaviors at a molecular spatial resolution.

Materials science↗

Multimodal super-resolution: discovering hidden physics and its application to fusion plasmas

Understanding complex physical systems often requires integrating data from multiple diagnostics, each with limited resolution or coverage. We present a machine learning framework that reconstructs synthetic high-temporal-resolution data for a target diagnostic using information from other diagnostics, without direct target measurements during the inference. This multimodal super-resolution technique improves diagnostic robustness and enables monitoring even in case of measurement failures or degradation. Applied to fusion plasmas, our method targets edge-localized modes (ELMs), which can damage plasma-facing materials. By reconstructing super-resolution Thomson Scattering data from complementary diagnostics, we uncover fine-scale plasma dynamics and validate the role of resonant magnetic perturbations (RMPs) in ELM suppression through magnetic island formation. The approach provides new observation supporting the plasma profile flattening due to these islands. Our results demonstrate the framework’s ability to generate high-fidelity synthetic diagnostics, offering a powerful tool for ELM control development in future reactors like ITER. The approach is broadly transferable to other domains facing sparse, incomplete, or degraded diagnostic data, opening new avenues for discovery.

Jalalvand, Azarakhsh [Princeton Univ., NJ (United ↗

Development and characterization of a laser-gated, high resolution x-ray radiography platform for high energy density experiments using toroidally bent crystals

Bent crystal x-ray imagers are a well-established diagnostic tool to study high energy density (HED) objects by acquiring two-dimensional x-ray radiographs. Often, studying these HED objects requires very high spatial resolution, which is limited by astigmatism when using spherically bent crystals. By using toroidal-shaped crystals instead, astigmatism can be reduced and the overall spatial resolution of the instrument improved. Here, the development and characterization of a laser-gated x-ray radiography platform at the National Ignition Facility using a toroidal crystal is presented. This includes measurements of the spatial and temporal profile, which is determined by the x-ray source. In conclusion, to properly validate the reduced astigmatism, a new multi-plane grid approach was implemented, which, for the first time, allows a depth of field measurement, alignment verification and x-ray source size estimate in a single shot, demonstrating the current platform’s capability to provide sub-10 μm resolution over a 0.9 mm depth of field with a temporal resolution of 110 ps.

Crystal optics↗

Phase-based velocity extraction method for photonic Doppler velocimetry with potential higher time resolution

We present an extension of the [Takeda et al., J. Opt. Soc. Am. 72, 156 (1982)] phase extraction method to heterodyne photonic Doppler velocimetry applications. The method yields results equivalent to those obtained by the short-time Fourier transform (STFT), while offering potential improvements in time resolution. Unlike STFT, which relies on window functions, such as the Hamming window, that emphasize central data points and diminish the influence of edges, the extended Takeda method utilizes all data uniformly. This uniform treatment allows for the derivation of empirical equations that directly relate velocity error to the actual time resolution rather than to the local analysis duration. The established equation provides a useful metric for both optimizing hardware configuration and guiding data analysis. Simulation and experimental results confirm that, for a given dataset, specifying a target time resolution yields consistent velocity errors for both methods. These findings underscore the Takeda method’s advantages, particularly its potential higher time resolution and reduced computational burden, making it a valuable tool for high-throughput applications such as laser dynamic compression experiments.

Computer simulation↗

High-resolution 3D-printed plastic scintillators with tertiary dye

Additive manufacturing offers efficient production of plastic scintillators with nontrivial geometries using vat polymerization, allowing fabrication of geometries which would be difficult or even impossible to produce using conventional subtractive manufacturing. This work presents a novel photocurable scintillator formula that includes coumarin 450 as a tertiary dye to enable high-resolution 3D printing via the manipulation of the 405 nm cure light. Bulk photocured and 3D printed (with and without tertiary dye) samples were compared through observational assessment and spectral response. All samples showed pulse shape discrimination between neutron and gamma events. Inclusion of the tertiary dye has minimal impact on emission spectrum and light output, but significant impact on print resolution as shown by comparison of printed high-complexity geometries and feature resolution test objects. With the use of a cure-limiting dye, unsupported features — such as freestanding pillars — were resolvable down to 0.7 mm. Even finer resolution at or below 0.1 mm was achieved in fully supported, integrated structures printed with off-the-shelf 405 nm desktop 3D printer. Scintillators demonstrated a light output up to 50% of EJ-200 with a PSD figure of merit up to 1.35 at 0.9–1.1 MeVee.

36 MATERIALS SCIENCE↗

Droplet bioprinting of acellular and cell-laden structures at high-resolutions

Advances in digital light projection(DLP) based (bio) printers have made printing of intricate structures at high resolution possible using a wide range of photosensitive bioinks. A typical setup of a DLP bioprinter includes a vat or reservoir filled with liquid bioink, which presents challenges in terms of cost associated with bioink synthesis, high waste, and gravity-induced cell settling, contaminations, or variation in bioink viscosity during the printing process. Here, we report a vat-free, low-volume, waste-free droplet bioprinting method capable of rapidly printing 3D soft structures at high resolution using model bioinks and model cells. A multiphase many-body dissipative particle dynamics model was developed to simulate the dynamic process of droplet-based DLP printing and elucidate the roles of surface wettability and bioink viscosity. Process variables such as light intensity, photo-initiator concentration, and bioink formulations were optimized to print 3D soft structures (∼0.4–3 kPa) with a typical layer thickness of 50 µm, an XY resolution of 38 ± 1.5 μm and Z resolution of 237 ± 5.4 µm. To demonstrate its versatility, droplet bioprinting was used to print a range of acellular 3D structures such as a lattice cube, a Mayan pyramid, a heart-shaped structure, and a microfluidic chip with endothelialized channels. Droplet bioprinting, performed using model C3H/10T1/2 cells, exhibited high viability (90%) and cell spreading. Additionally, microfluidic devices with internal channel networks lined with endothelial cells showed robust monolayer formation while osteoblast-laden constructs showed mineral deposition upon osteogenic induction. Overall, droplet bioprinting could be a low-cost, no-waste, easy-to-use, method to make customized bioprinted constructs for a range of biomedical applications.

DLP↗

Super-Resolution Ptychography with Small Segmented Detectors

To overcome the spatial resolution limit set by aperture-limited diffraction in traditional scanning transmission electron microscopy, microscopists have developed ptychography enabled by iterative phase retrieval algorithms and high-dynamic-range pixel array detectors. Current detector designs are limited by the data rate off chip, so a high-pixel-count detector has a proportionally lower frame rate than the few-segment detectors used for differential phase contrast (DPC) imaging. This slower acquisition speed leads to heightened vulnerability to scan noise, drift, and potential sample damage. This creates opportunities for repurposing fast segmented detectors for ptychography by trading a reduction in reciprocal space pixels for an increase in real space pixels. Here, we explore a strategy of oversampling in real space and instead apply detector pixel upsampling during the reconstruction process. Further, we demonstrate the viability of achieving super-resolution ptychography on thin objects using only 2 × 2 detector pixels, surpassing the resolution of integrated DPC (iDPC) imaging. With optimization using simulated datasets and experiments on MoTe 2 /WSe 2 bilayer moiré superlattices, we achieved super-resolution ptychography reconstructions under rapid acquisition conditions (37.5 pA, 1 μs dwell time), yielding over 50% improvements in contrast and information limit compared to annular dark field and iDPC imaging on the same detectors.

2D materials↗

Impact of tracking resolution on 𝜙-meson spin alignment measurements

Measurements of global spin alignment of vector mesons in relativistic heavy-ion collisions can provide unique insights into spin-orbit interactions and vector meson dynamics in the quark-gluon plasma produced in those collisions. The global spin alignment is measured by the 00th coefficient of the spin density matrix, 𝜌 00 , via the polar angle (𝜃*) of the decay-kaon momentum in the parent rest frame with respect to the direction of the orbital angular momentum of the collision. Such measurements are affected by the angular and momentum resolutions of the reconstructed tracks in the experiment. Such effects are nontrivial because of kinematic complications caused by the boost to the parent rest frame, and could be important given that the global spin alignment signal is weak. In this paper, we investigate the effects of experimental tracking resolutions on measurements of the 𝜙 (1020) meson 𝜌 00 . We study these effects for two methods of 𝜌 00 measurements, the conventional method analyzing the 𝜙⁢−meson yield versus cos 2 ⁡𝜃* and the invariant mass (𝑚 inv ) method utilizing ⟨cos 2 ⁡𝜃*⟩ versus 𝑚 inv . Using typical resolution values from experiments, we find that the effect of track resolution on 𝜌 00 is small, well within typical measurement uncertainties.

Relativistic heavy-ion collisions↗

High-luminosity meV-resolution single-shot hard X-ray spectrograph for cavity-based X-ray free-electron lasers

Cavity-based X-ray free-electron lasers (CBXFELs) represent a possible realization of fully coherent hard X-ray sources having high spectral brilliance along with a narrow spectral bandwidth of ∼1–50 meV, a high repetition pulse rate of ∼1 MHz, and good stability. A diagnostic tool is required to measure CBXFEL spectra with meV resolution and high luminosity on a shot-to-shot basis. We have designed a high-luminosity single-shot hard X-ray spectrograph that images 9.831 keV X-rays in a ∼200 meV spectral window with a spectral resolution of a few meV. The spectrograph is designed around angular dispersion of X-rays in Bragg diffraction from crystals. It operates close to design specifications, exhibiting a linear dispersion rate of ∼1.4 µm meV −1 and a ∼200 meV window of high-fidelity spectral imaging. The experimentally demonstrated spectral resolution is ∼20 meV; this resolution is twice as low as expected from theory primarily because the spectrograph is highly sensitive to crystal angular instabilities. The experiment was performed at the bending magnet X-ray optics testing beamline 1-BM at the Advanced Photon Source.

Bragg diffraction↗