Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “regression analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Model results and data for Nontechnical Barriers to Geothermal Development

Data included in this submission support the analysis conducted for the report "Nontechnical Barriers to Geothermal Development" which is linked bellow. These data include information about the power purchase agreements (PPAs) analyzed for the report, inputs and model results for the pro forma economic analysis, and outputs from the regression analysis conducted on PPAs comparing geothermal and other power generation technologies.

15 GEOTHERMAL ENERGY↗

Use of a New Hybrid Heparin-Bonded Nitinol Ring Stent in the Popliteal Artery: Procedural and Mid-term Clinical and Anatomical Outcomes

PurposeTo report the immediate and mid-term clinical and anatomical outcomes of a novel, hybrid, heparin-bonded, nitinol ring stent (TIGRIS; Gore Medical) when used for the treatment of lesions located in the popliteal artery.Materials and MethodsThis was a prospective single-centre registry. Patients eligible for inclusion were individuals suffering from symptomatic popliteal arterial occlusive disease (Rutherford–Becker stage 3–6; P1–P3 segments) and treated with placement of the TIGRIS stent(s). Patients were prospectively scheduled for clinical review and duplex ultrasound follow-up after 6 and 12 months. Outcome measures included immediate technical success, primary vessel patency, in-stent binary restenosis (evaluable by Duplex at 50 % threshold; PSVR > 2.0), freedom from target lesion revascularization (TLR) and amputation-free survival (AFS) estimated by Kaplan–Meier (K–M) survival analysis. Cox proportional-hazards regression analysis was also performed to adjust for confounders and search for independent predictors of outcomes.ResultsFrom August 2012 to March 2014, a total of 54 popliteal TIGRIS stents were implanted in 50 limbs of 48 patients (27 men and 21 women; mean age 76.0 ± 1.7 years). Median Rutherford–Becker stage was five at baseline and 37/50 (74.0 %) were chronic total occlusions. Technical success was achieved in all cases (100 %). Stented lesion length was 114.2 ± 36.9 mm (range 6–20 cm). Median follow-up was 11.8 ± 0.8 months. After 12 months, primary patency of the TIGRIS stent was 69.5 ± 10.2 % with an 86.1 ± 5.9 % freedom from TLR and 87 ± 5.0 % AFS (K–M estimates).ConclusionThe TIGRIS hybrid heparin-bonded nitinol ring stent is a safe and effective endovascular option for complex occlusive disease of the popliteal artery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-P-52: Dose-Volume Toxicity Analysis of Stereotactic Body Radiation Therapy for Hepatocellular Carcinoma

Purpose: To investigate the relationship between physical and biological effective dose (BED) to liver toxicity for SBRT fractionations. Methods: A total of 16 patients (13–10×3Gy, 2–5×10Gy and 1–3×15Gy were selected. Physical dose distributions were converted to voxel based BED values using the linear-quadratic (LQ) and linear-quadratic linear (LQ-L) models for doses per fraction larger than 6Gy. Patients were graded for effective toxicity (post-treatment minus pre-treatment grades) using the RTOG Late Radiation Morbidity Scoring Schema associated with Radiation Induced Liver Disease (RILD). Evaluated physical dose-volume levels consisted of V10Gy, V15Gy, V20Gy, V25Gy and V30Gy which were then converted to BED values corresponding to V16.7Gy3, V30Gy3, V46.7Gy3, V66.7Gy3 and V90Gy3, respectively. All levels were normalized to their respective patient normal liver volumes (NLV) and evaluated for correlation to RILD. Results were measured quantitatively using R-squared regression analysis. Results: Mean Dose Tolerable to Normal Liver (MDTNL) against RILD grade resulted in an R-squared value of 0.0104. NLV-normalized physical dose linear regression fit of V10Gy, V15Gy, V20Gy, V25Gy and V30Gy against RILD yielded R-squared values of 0.1041, 0.0895, 0.0698, 0.0398 and 0.0009 while BED levels of V16.7Gy3, V30Gy3, V46.7Gy3, V66.7Gy3 and V90Gy3 resulted in values of 0.0002, 0.0153, 0.0533, 0.0427 and 0.0072, respectively. The average NLV-normalized V10Gy, V15Gy, V20Gy, V25Gy and V30Gy per grade plotted against RILD grade yielded R-squared correlations of 0.8092, 0.6362, 0.5899, 0.5846 and 0.0224 while the BED levels of V16.7Gy3, V30Gy3, V46.7Gy3, V66.7Gy3 and V90Gy3 resulted in R-squared correlations of 0.0003, 0.3831, 0.8476, 0.678 and 0.076, respectively. Conclusion: Regression analysis between physical dose, BED and RILD showed strong correlation for the V30Gy and V46.7Gy3 dose-levels. Average BED and physical dose per grade both exhibit strong correlations to RILD however, a lack of statistical significance exists due to small patient sample size.

60 APPLIED LIFE SCIENCES↗

Deriving the Intrahepatic Arteriovenous Shunt Rate from CT Images and Biochemical Data Instead of from Arterial Perfusion Scintigraphy in Hepatic Arterial Infusion Chemotherapy

The purpose of the present study was to elucidate a method for predicting the intrahepatic arteriovenous shunt rate from computed tomography (CT) images and biochemical data, instead of from arterial perfusion scintigraphy, because adverse exacerbated systemic effects may be induced in cases where a high shunt rate exists. CT and arterial perfusion scintigraphy were performed in patients with liver metastases from gastric or colorectal cancer. Biochemical data and tumor marker levels of 33 enrolled patients were measured. The results were statistically verified by multiple regression analysis. The total metastatic hepatic tumor volume (V{sub metastasized}), residual hepatic parenchyma volume (V{sub residual}; calculated from CT images), and biochemical data were treated as independent variables; the intrahepatic arteriovenous (IHAV) shunt rate (calculated from scintigraphy) was treated as a dependent variable. The IHAV shunt rate was 15.1 {+-} 11.9%. Based on the correlation matrixes, the best correlation coefficient of 0.84 was established between the IHAV shunt rate and V{sub metastasized} (p < 0.01). In the multiple regression analysis with the IHAV shunt rate as the dependent variable, the coefficient of determination (R{sup 2}) was 0.75, which was significant at the 0.1% level with two significant independent variables (V{sub metastasized} and V{sub residual}). The standardized regression coefficients ({beta}) of V{sub metastasized} and V{sub residual} were significant at the 0.1 and 5% levels, respectively. Based on this result, we can obtain a predicted value of IHAV shunt rate (p < 0.001) using CT images. When a high shunt rate was predicted, beneficial and consistent clinical monitoring can be initiated in, for example, hepatic arterial infusion chemotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-83: CBCT Based Rectum and Bladder Dose Tracking in the Prostate Radiotherapy

Purpose: The aim of this study is to monitor the volume changes of bladder and rectum and evaluate the dosimetric changes of bladder and rectum using daily cone-beam CT for prostate radiotherapy. Methods: The data of this study were obtained from 12 patients, totally 222 CBCTs. All the volume of the bladder and the rectum on the CBCT were normalized to the bladder and the rectum on their own original CT to monitory the volume changes. To evaluate dose delivered to the OARs, volumes that receive 70Gy (V70Gy), 60Gy, 50Gy, 40Gy and 30Gy are calculated for the bladder and the rectum, V20Gy and V10Gy for rectum additionally. And the deviation of the mean dose to the bladder and the rectum are also chosen as the evaluation parameter. Linear regression analysis was performed to identify the mean dose change of the volume change using SPSS 19. Results: The results show that the variances of the normalize volume of the bladder and the rectum are 0.15–0.58 and 0.13–0.50. The variances of V70Gy, V60Gy, V50Gy, V40Gy and V30Gy of bladder are bigger than rectum for 11 patients. The linear regression analysis indicated a negative correlation between the volume and the mean dose of the bladder (p < 0.05). A 10% increase in bladder volume will cause 5.1% (±4.3%) reduction in mean dose. Conclusion: The bladder volume change is more significant than that for rectum for the prostate cancer patient. The volume changes of rectum are not significant except air gap in the rectum. Bladder volume varies will cause significant dose change. The bladder volume monitoring before fractional treatment delivery would be crucial for accuracy dose delivery.

60 APPLIED LIFE SCIENCES↗

Lack of a Dose-Effect Relationship for Pulmonary Function Changes After Stereotactic Body Radiation Therapy for Early-Stage Non-Small Cell Lung Cancer

Purpose: To evaluate the influence of tumor size, prescription dose, and dose to the lungs on posttreatment pulmonary function test (PFT) changes after stereotactic body radiation therapy (SBRT) for early-stage non-small cell lung cancer (NSCLC). Methods and Materials: The analysis is based on 191 patients treated at 5 international institutions: inclusion criteria were availability of pre- and post-SBRT PFTs and dose-volume histograms of the lung and planning target volume (PTV); patients treated with more than 1 SBRT course were excluded. Correlation between early (1-6 months, median 3 months) and late (7-24 months, median 12 months) PFT changes and tumor size, planning target volume (PTV) dose, and lung doses was assessed using linear regression analysis, receiver operating characteristics analysis, and Lyman's normal tissue complication probability model. The PTV doses were converted to biologically effective doses and lung doses to 2 Gy equivalent doses before correlation analyses. Results: Up to 6 months after SBRT, forced expiratory volume in 1 second and carbon monoxide diffusion capacity changed by −1.4% (95% confidence interval [CI], −3.4% to 0) and −7.6% (95% CI, −10.2% to −3.4%) compared with pretreatment values, respectively. A modest decrease in PFTs was observed 7-24 months after SBRT, with changes of −8.1% (95% CI, −13.3% to −5.3%) and −12.4% (95% CI, −15.5% to −6.9%), respectively. Using linear regression analysis, receiver operating characteristic analysis, and normal tissue complication probability modeling, all evaluated parameters of tumor size, PTV dose, mean lung dose, and absolute and relative volumes of the lung exposed to minimum doses of 5-70 Gy were not correlated with early and late PFT changes. Subgroup analysis based on pre-SBRT PFTs (greater or equal and less than median) did not identify any dose-effect relationship. Conclusions: This study failed to demonstrate a significant dose-effect relationship for changes of pulmonary function after SBRT for early-stage non-small cell lung cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Carotid Artery Stenosis at MSCT: Is there a Threshold in Millimeters that Determines Clinical Significance?

Purpose: The purpose of this work was to determine whether it is possible to identify a reliable carotid stenosis threshold-measured in millimeters (mm)-that is associated with cerebrovascular symptoms. Methods: Written, informed consent was obtained for each patient; 149 consecutive patients (98 men; median age, 68 years) were studied for suspected pathology of the carotid arteries by using MDCTA. In each patient, carotid artery stenosis was quantified using the mm-method. Continuous data were described as the mean value {+-} standard deviation (SD), and they were compared by using the Student's t test. A ROC curve was calculated to test the study hypothesis and identify a specific mm-stenosis threshold. Logistic regression analysis was performed to include other MDCTA findings, such as plaque type and ulcerations. A P value < 0.05 was considered to indicate statistical significance. Results: Twenty-six patients were excluded. Of those remaining, 75 patients suffered cerebrovascular symptoms (61%). There was a statistically significant difference (P = 0.0046) in the mm-carotid stenosis between patients with symptoms (1.31 {+-} 0.64 mm SD) and without symptoms (1.68 {+-} 0.79 mm SD). Multiple logistic regression analysis confirmed that symptoms were associated with increased luminal stenosis (P = 0.013) and with the presence of fatty plaques (P = 0.0491). Moreover, the ROC curve (Az = 0.669; {+-}0.051 SD; P = 0.0009) indicated that a threshold of 1.6 mm stenosis was associated with a sensitivity to symptoms of 76%. Conclusions: The results of our study suggest an association between luminal stenosis (measure in mm) and the presence of cerebrovascular symptoms. Luminal stenosis of 1.6 mm is associated, with a sensitivity of 76%, with cerebrovascular symptoms.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Different behavioral effect dose–response profiles in mice exposed to two-carbon chlorinated hydrocarbons: Influence of structural and physical properties

The present study aimed to clarify whether dose–response profiles of acute behavioral effects of 1,2-dichloroethane (DCE), 1,1,1-trichloroethane (TCE), trichloroethylene (TRIC), and tetrachloroethylene (PERC) differ. A test battery involving 6 behavioral endpoints was applied to evaluate the effects of DCE, TCE, TRIC, and PERC in male ICR strain mice under the same experimental conditions. The behavioral effect dose–response profiles of these compounds differed. Regression analysis was used to evaluate the relationship between the dose–response profiles and structural and physical properties of the compounds. Dose–response profile differences correlated significantly with differences in specific structural and physical properties. These results suggest that differences in specific structural and physical properties of DCE, TCE, TRIC, and PERC are responsible for differences in behavioral effects that lead to a variety of dose–response profiles. - Highlights: • We examine effects of 4 chlorinated hydrocarbons on 6 behavioral endpoints in mice. • The behavioral effect dose–response profiles for the 4 compounds are different. • We utilize regression analysis to clarify probable causes of the different profiles. • The compound's physicochemical properties probably produce the different profiles.

60 APPLIED LIFE SCIENCES↗

Efficacy of Salvage Radiotherapy Plus 2-Year Androgen Suppression for Postradical Prostatectomy Patients With PSA Relapse

Purpose: To determine the efficacy of a combined approach of radiotherapy (RT) plus 2-year androgen suppression (AS) as salvage treatment for prostate-specific antigen (PSA) relapse after radical prostatectomy (RP). Methods and Materials: Seventy-five patients with PSA relapse after RP were treated with salvage RT plus 2-year AS, as per a pilot, prospective study. AS started within 1 month after completion of salvage RT and consisted of nilutamide for 4 weeks and buserelin acetate depot subcutaneously every 2 months for 2 years. Relapse-free rate including freedom from PSA relapse was estimated using the Kaplan-Meier method. PSA relapse was defined as a PSA rise above 0.2 ng/mL with two consecutive increases over a minimum of 3 months. A Cox regression analysis was performed to evaluate prognostic factors for relapse. Results: Median age of the cohort was 63 years at the time of salvage RT. Median follow-up from salvage RT was 6.4 years. All achieved initially complete PSA response (< 0.2) with the protocol treatment. Relapse-free rate including the freedom from PSA relapse was 91.5% at 5 years and 78.6% at 7 years. Overall survival rate was 93.2% at both 5 and 7 years. On Cox regression analysis, pT3 stage and PSA relapse less than 2 years after RP were significant prognostic factors for relapse. Conclusion: The combined treatment of salvage RT plus 2-year AS yielded an encouraging result for patients with PSA relapse after RP and needs a confirmatory study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Postoperative weight loss followed by radical cystectomy predicts poor prognosis in patients with muscle-invasive bladder cancer

We aimed to investigate the impact of postoperative weight loss following radical cystectomy (RC) on patients’ prognoses. RC and urinary diversion were performed in 512 consecutive patients with muscle-invasive bladder cancer at our hospitals between May 1996 and July 2018. Demographic clinical information, pre- and postoperative serum albumin, hemoglobin, and weight were evaluated retrospectively at 1 month. We also evaluated the association of weight loss with complications and overall survival (OS) as estimated using the Kaplan–Meier method and compared using the log-rank test. Risk factors for poor OS were determined by Inverse Probability of Treatment Weighted (IPTW)-adjusted Cox regression analysis. In 385 patients who met the study search criteria, median postoperative weight loss from baseline at 1 week and 1 month was 1.1 (− 1.8%) and 3.2 (− 5.4%) kg, respectively. Patients with significant weight loss (defined as ≥ 7.5% at 1 month) had higher-grade complications within 1 month and had significantly shorter OS than those with weight loss of < 7.5%. Type of urinary diversion, loss of serum albumin, and loss of hemoglobin were not significantly associated with weight loss. IPTW-adjusted Cox regression analysis showed that such significant weight loss was an independent risk factor for poor OS. Weight loss followed by radical cystectomy was significantly associated with poor prognosis in patients with muscle-invasive bladder cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MR texture analysis: potential imaging biomarker for predicting the chemotherapeutic response of patients with colorectal liver metastases

Purpose: The purpose of the study was to determine whether the pre-treated MR texture features of colorectal liver metastases (CRLMs) are predictive of therapeutic response after chemotherapy. Methods: The study included twenty-six consecutive patients (a total of 193 liver metastasis) with unrespectable CRLMs at our institution from August 2014 to February 2016. Lesions were categorized into either responding group or non-responding group according to changes in size. Texture analysis was quantified on T2-weighted images by two radiologists with consensus on regions of interest which were manually drawn on the largest cross-sectional area of the lesions. Five histogram features (mean, variance, skewness, kurtosis, and entropy{sup 1}) and five gray level co-occurrence matrix features (GLCM; angular second moment (ASM), entropy{sup 2}, contrast, correlation, and inverse difference moment (IDM)) were extracted. The texture parameters were statistically analyzed to identify the differences between the two groups, and the potential predictive parameters to differentiate the responding group from the non-responding group were subsequently tested using multivariable logistic regression analysis. Results: A total of 107 responding and 86 non-responding lesions were evaluated. A higher variance, entropy{sup 1}, contrast, entropy{sup 2} and a lower ASM, correlation, IDM were independently (P < 0.05) associated with a good response to chemotherapy with the areas under the ROC curves (AUCs) of 0.602–0.784. Variance (P < 0.001) and ASM (P = 0.001) remained potential predictive values to discriminate responding lesions from non-responding lesions when tested using multivariable logistic regression analysis. The highest AUC of the predictors from the association of variance and ASM was 0.814. Conclusion: MR texture features on pre-treated T2 images have the potential to predict the therapeutic response of colorectal liver metastases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Predictive role of PI-RADSv2 and ADC parameters in differentiating Gleason pattern 3 + 4 and 4 + 3 prostate cancer

Purpose: To compare the predictive roles of qualitative (PI-RADSv2) and quantitative assessment (ADC metrics), in differentiating Gleason pattern (GP) 3 + 4 from the more aggressive GP 4 + 3 prostate cancer (PCa) using radical prostatectomy (RP) specimen as the reference standard. Methods: We retrospectively identified treatment-naïve peripheral (PZ) and transitional zone (TZ) Gleason Score 7 PCa patients who underwent multiparametric 3T prostate MRI (DWI with b value of 0,1400 and where unavailable, 0,500) and subsequent RP from 2011 to 2015. For each lesion identified on MRI, a PI-RADSv2 score was assigned by a radiologist blinded to pathology data. A PI-RADSv2 score ≤ 3 was defined as “low risk,” a PI-RADSv2 score ≥ 4 as “high risk” for clinically significant PCa. Mean tumor ADC (ADC{sub T}), ADC of adjacent normal tissue (ADC{sub N}), and ADC{sub ratio} (ADC{sub T}/ADC{sub N}) were calculated. Stepwise regression analysis using tumor location, ADC{sub T} and ADC{sub ratio}, b value, low vs. high PI-RADSv2 score was performed to differentiate GP 3 + 4 from 4 + 3. Results: 119 out of 645 cases initially identified met eligibility requirements. 76 lesions were GP 3 + 4, 43 were 4 + 3. ADC{sub ratio} was significantly different between the two GP groups (p = 0.001). PI-RADSv2 score (“low” vs. “high”) was not significantly different between the two GP groups (p = 0.17). Regression analysis selected ADC{sub T} (p = 0.03) and ADC{sub ratio} (p = 0.0007) as best predictors to differentiate GP 4 + 3 from 3 + 4. Estimated sensitivity, specificity, and accuracy of the predictive model in differentiating GP 4 + 3 from 3 + 4 were 37, 82, and 66%, respectively. Conclusions: ADC metrics could differentiate GP 3 + 4 from 4 + 3 PCa with high specificity and moderate accuracy while PI-RADSv2, did not differentiate between these patterns.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Risk of Positive Sentinel Lymph Node After Neoadjuvant Systemic Therapy in Clinically Node-Negative Breast Cancer: Implications for Postmastectomy Radiation Therapy and Immediate Breast Reconstruction

Background: Residual axillary lymph node involvement after neoadjuvant systemic therapy (NST) is the determining factor for postmastectomy radiation therapy (PMRT). Preoperative identification of patients needing PMRT is essential to enable shared decision-making when choosing the optimal timing of breast reconstruction. We determined the risk of positive sentinel lymph node (SLN) after NST in clinically node-negative (cN0) breast cancer. Methods: All cT1-3N0 patients treated with NST followed by mastectomy and SLNB between 2010 and 2016 were identified from the Netherlands Cancer Registry. Rate of positive SLN for different breast cancer subtypes was determined. Logistic regression analysis was performed to determine correlated clinicopathological variables with positive SLN. Results: In total 788 patients were included, of whom 25.0% (197/788) had positive SLN. cT1-3N0 ER+HER2+, cT1-3N0 ER−HER2+ , and cT1-2N0 triple-negative patients had the lowest rate of positive SLN: 7.2–11.5%, 0–6.3%, and 2.9–6.2%, respectively. cT1-3N0 ER+HER2− and cT3N0 triple-negative patients had the highest rate of positive SLN: 23.8–41.7% and 30.4%, respectively. Multivariable regression analysis showed that cT2 (odds ratio [OR] 1.93; 95% confidence interval [CI] 1.01–3.96), cT3 (OR 2.56; 95% CI 1.30–5.38), grade 3 (OR 0.44; 95% CI 0.21–0.91), and ER+HER2− subtype (OR 3.94; 95% CI 1.77–8.74) were correlated with positive SLN. Conclusions: In cT1-3N0 ER+HER2+, cT1-3N0 ER−HER2+, and cT1-2N0 triple-negative patients treated with NST, immediate reconstruction can be considered an acceptable option due to low risk of positive SLN. In cT1-3N0 ER+HER2− and cT3N0 triple-negative patients treated with NST, risks and benefits of immediate reconstruction should be discussed with patients due to the relatively high risk of positive SLN.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TH-E-BRF-05: Comparison of Survival-Time Prediction Models After Radiotherapy for High-Grade Glioma Patients Based On Clinical and DVH Features

Purpose: Although many outcome prediction models based on dose-volume information have been proposed, it is well known that the prognosis may be affected also by multiple clinical factors. The purpose of this study is to predict the survival time after radiotherapy for high-grade glioma patients based on features including clinical and dose-volume histogram (DVH) information. Methods: A total of 35 patients with high-grade glioma (oligodendroglioma: 2, anaplastic astrocytoma: 3, glioblastoma: 30) were selected in this study. All patients were treated with prescribed dose of 30–80 Gy after surgical resection or biopsy from 2006 to 2013 at The University of Tokyo Hospital. All cases were randomly separated into training dataset (30 cases) and test dataset (5 cases). The survival time after radiotherapy was predicted based on a multiple linear regression analysis and artificial neural network (ANN) by using 204 candidate features. The candidate features included the 12 clinical features (tumor location, extent of surgical resection, treatment duration of radiotherapy, etc.), and the 192 DVH features (maximum dose, minimum dose, D95, V60, etc.). The effective features for the prediction were selected according to a step-wise method by using 30 training cases. The prediction accuracy was evaluated by a coefficient of determination (R{sup 2}) between the predicted and actual survival time for the training and test dataset. Results: In the multiple regression analysis, the value of R{sup 2} between the predicted and actual survival time was 0.460 for the training dataset and 0.375 for the test dataset. On the other hand, in the ANN analysis, the value of R{sup 2} was 0.806 for the training dataset and 0.811 for the test dataset. Conclusion: Although a large number of patients would be needed for more accurate and robust prediction, our preliminary Result showed the potential to predict the outcome in the patients with high-grade glioma. This work was partly supported by the JSPS Core-to-Core Program(No. 23003) and Grant-in-aid from the JSPS Fellows.

60 APPLIED LIFE SCIENCES↗

WE-AB-207B-12: Prospective Study of the Relationship Between Dose-Volume Clinical Toxicity and Patient Reported Outcomes in Lung Cancer Patients Treated with SBRT

Purpose: To determine in a prospective study, the correlation between radiation dose/volume, clinical toxicities and patient-reported, quality of life (QOL) resulting from lung SBRT. Methods: For 106 non-small cell lung cancer (NSCLC) patients receiving SBRT (12 Gy × 4), symptoms including cough, dyspnea, fatigue and pneumonitis were measured at baseline (before treatment), after treatment and 3, 6, and 12 months post-treatment. Toxicity was graded from zero to five. Dosimetric parameters such as the MLD, D10%, D20%, and lung subvolumes (V10 and V20) were obtained from the treatment plan. Dosimetric parameters and number of patients demonstrating toxicity ≥ grade 2 were tabulated. Linear regression analysis was used to calculate correlations between MLD and D10, D20, V10 and V20. Results: The percentages of patients with > grade 2 pneumonitis, fatigue, cough, and dyspnea over 3 to 12 months increased from 0.0% to 3.5%, 3.2% to 10.5%, 4.3% to 8.3%, and 10.8% to 18.8%, respectively. Computed dose indices D10%, D20% were 7.9±4.8 Gy and 3.0±2.3 Gy, respectively. MLD ranged from 0.34 Gy up to 9.9 Gy with overall average 3.0±1.7 Gy. The averages of the subvolumes V10 and V20 were respectively 8.9±5.3% and 3.0±2.4%. The linear regression analysis showed that V10 and D10 demonstrated the strongest correlation to MLD; R2= 0.92 and 0.87, respectively. V20, and D20 were also strongly correlated with MLD; R2 = 0.81 and 0.84 respectively. A correlation was also found to exist between MLD > 2 Gy and ≥ grade 2 cough and dyspnea. Subvolume values for 2Gy MLD were 5.3% for V10 and 2% for V20. Conclusion: Dosimetric indices: MLD ≥ 2Gy, D10 ≥ 5Gy and V10 ≥ 5% of the total lung volume were predictive of > grade 2 cough and dyspnea QOL data. The QOL results are a novel component of this work. acknowledgement of the Varian grant support.

60 APPLIED LIFE SCIENCES↗

Prospective Study Evaluating Postoperative Radiotherapy Plus 2-Year Androgen Suppression for Post-Radical Prostatectomy Patients With Pathologic T3 Disease and/or Positive Surgical Margins

Purpose: To determine the efficacy of a combined approach of postoperative radiotherapy (RT) plus 2-year androgen suppression (AS) for patients with pathologic T3 disease (pT3) and/or positive surgical margins (PSM) after radical prostatectomy (RP). Methods and Materials: A total of 78 patients with pT3 and/or PSM after RP were treated with RT plus 2-year AS, as per a pilot, prospective study. Androgen suppression started within 1 month after the completion of RT and consisted of nilutamide for 4 weeks and buserelin acetate depot subcutaneously every 2 months for 2 years. Relapse-free rate, including freedom from prostate-specific antigen (PSA) relapse, was estimated using the Kaplan-Meier method. A Cox regression analysis was performed to evaluate prognostic factors for relapse. Prostate-specific antigen relapse was defined as a PSA rise above 0.2 ng/mL, with two consecutive increases over a minimum of 3 months. Results: The median age was 61 years at the time of RP. The median interval between RP and postoperative RT was 4.2 months. Forty-nine patients had undetectable PSA (<0.2 ng/mL), and 29 had persistently detectable postoperative PSA at the time of the protocol treatment. Median follow-up from RT was 6.4 years. Relapse-free rates at 5 and 7 years were 94.4% and 86.3%, respectively. Survival rates were 96% at 5 years and 93.1% at 7 years. On Cox regression analysis, persistently detectable postoperative PSA and pT3b-T4 were significant predictors for relapse. Conclusion: The combined treatment of postoperative RT plus 2-year AS yielded encouraging results for patients with pT3 and/or PSM and warrants a confirmatory study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of image guided motion management methods in lung cancer radiotherapy

Purpose: To evaluate the accuracy and reliability of three target localization methods for image guided motion management in lung cancer radiotherapy. Methods: Three online image localization methods, including (1) 2D method based on 2D cone beam (CB) projection images, (2) 3D method using 3D cone beam CT (CBCT) imaging, and (3) 4D method using 4D CBCT imaging, have been evaluated using a moving phantom controlled by (a) 1D theoretical breathing motion curves and (b) 3D target motion patterns obtained from daily treatment of 3 lung cancer patients. While all methods are able to provide target mean position (MP), the 2D and 4D methods can also provide target motion standard deviation (SD) and excursion (EX). For each method, the detected MP/SD/EX values are compared to the analytically calculated actual values to calculate the errors. The MP errors are compared among three methods and the SD/EX errors are compared between the 2D and 4D methods. In the theoretical motion study (a), the dependency of MP/SD/EX error on EX is investigated with EX varying from 2.0 cm to 3.0 cm with an increment step of 0.2 cm. In the patient motion study (b), the dependency of MP error on target sizes (2.0 cm and 3.0 cm), motion patterns (four motions per patient) and EX variations is investigated using multivariant linear regression analysis. Results: In the theoretical motion study (a), the MP detection errors are −0.2 ± 0.2, −1.5 ± 1.1, and −0.2 ± 0.2 mm for 2D, 3D, and 4D methods, respectively. Both the 2D and 4D methods could accurately detect motion pattern EX (error < 1.2 mm) and SD (error < 1.0 mm). In the patient motion study (b), MP detection error vector (mm) with the 2D method (0.7 ± 0.4) is found to be significantly less than with the 3D method (1.7 ± 0.8,p < 0.001) and the 4D method (1.4 ± 1.0, p < 0.001) using paired t-test. However, no significant difference is found between the 4D method and the 3D method. Based on multivariant linear regression analysis, the variances of MP error in SI direction explained by target sizes, motion patterns, and EX variations are 9% with the 2D method, 74.4% with the 3D method, and 27% with the 4D method. The EX/SD detection errors are both < 1.0 mm for the 2D method and < 2.0 mm for the 4D method. Conclusions: The 2D method provides the most accurate MP detection regardless of the motion pattern variations, while its performance is limited by the accuracy of target identification in the projection images. The 3D method causes the largest error in MP determination, and its accuracy significantly depends on target sizes, motion patterns, and EX variations. The 4D method provides moderate MP detection results, while its accuracy relies on a regular motion pattern. In addition, the 2D and 4D methods both provide accurate measurement of the motion SD/EX, providing extra information for motion management.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Long-Term Failure Patterns and Survival in a Randomized Dose-Escalation Trial for Prostate Cancer. Who Dies of Disease?

Purpose: To report long-term failure patterns and survival in a randomized radiotherapy dose escalation trial for prostate cancer. Materials and Methods: A total of 301 patients with Stage T1b-T3 prostate cancer treated to 70 Gy versus 78 Gy now have a median follow-up of 9 years. Failure patterns and survival were compared between dose levels. The cumulative incidence of death from prostate cancer versus other causes was examined and regression analysis was used to establish predictive factors. Results: Patients with pretreatment prostate-specific antigen (PSA) >10 ng/mL or high-risk disease had higher biochemical and clinical failures rates when treated to 70 Gy. These patients also had a significantly higher risk of dying of prostate cancer. Patients <70 years old at treatment died of prostate cancer nearly three times more frequently than of other causes when they were radiated to 70 Gy, whereas those treated to 78 Gy died of other causes more frequently. Patients age 70 or older treated to 70 Gy died of prostate cancer as often as other causes, and those receiving 78 Gy never died of prostate cancer within 10 years of follow-up. In regression analysis, factors predicting for death from prostate cancer were pretreatment PSA >10.5 ng/mL, Gleason score 9 and 10, recurrence within 2.6 years of radiation, and doubling time of <3.6 months at the time of recurrence. Conclusions: Moderate dose escalation (78 Gy) decreases biochemical and clinical failure as well as prostate cancer death in patients with pretreatment PSA >10 ng/mL or high-risk disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗