Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “refrigerators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Toward a life cycle approach for classifying the toxicity of refrigerants

Refrigeration and air conditioning currently account for ~20% of the total electricity consumption in buildings around the world (IEA, 2018). Over the next three decades, as global temperatures are projected to increase, urbanization and economic growth will lead to an increased demand for refrigeration and cooling. While technological advances have led to increased cooling capacity and safer refrigerants over the years, emissions from refrigeration systems can affect the environment by contributing to greenhouse gas emissions or by depleting the ozone layer, depending on the gas emitted. Further, because of ongoing and pending policy and regulatory changes to avert ozone depletion and global climate change, there is an increasing focus on adopting compounds that are efficient at cooling while also reducing emissions and other adverse environmental impacts.

54 ENVIRONMENTAL SCIENCES↗

Virtual refrigerant charge sensing algorithm for residential CO₂ heat pumps

Natural refrigerants are increasingly adopted in next-generation heat pump systems, among which CO₂ heat pumps have attracted significant attention. However, due to their high operating pressures, the leakage risk is higher, resulting in undercharge conditions and degraded heat pump performance. Thus, developing an accurate refrigerant charge level detection technique is necessary to guarantee safe and efficient operation. Although virtual refrigerant charge (VRC) level calculation algorithms for CO₂ heat pumps exist, they typically rely on empirically selected features without a systematic selection framework, leading to multicollinearity and potential overfitting, which limit their prediction accuracy and generalizability. To address these issues, this study proposes a VRC algorithm framework with a systematic feature selection method that identifies physically meaningful and statistically significant features, and is applied using a residential CO₂ heat pump as a case study. The method is extended from previous work on conventional refrigerants to account for charge behavior in CO₂ gas coolers. The selected features include gas cooler outlet density, evaporator pressure, and superheat temperature. The results demonstrate that the proposed feature selection method significantly improves prediction accuracy compared to existing VRC approaches. A relatively small training dataset (∼30 samples) is sufficient for feature identification and model development. The developed algorithm achieves less than 3% prediction error under both undercharge and overcharge conditions, representing reductions of 46.7% and 35.3% compared to two recent reference VRC algorithms for transcritical CO₂ heat pumps reported in the literature. The proposed algorithm and feature selection method enhance leakage detection capability, facilitate the deployment of CO₂ heat pump systems, and contribute to reduced energy waste and maintenance costs.

Guo, Fangzhou [Lawrence Berkeley National Laborato↗

A 1-km photonic link connecting superconducting circuits in two dilution refrigerators

Superconducting quantum processors are a leading platform for implementing practical quantum computation algorithms. Although superconducting quantum processors with hundreds of qubits have been demonstrated, their further scale-up is constrained by the physical size and cooling power of dilution refrigerators. This constraint can be overcome by constructing a quantum network to interconnect qubits hosted in different refrigerators, which requires microwave-to-optical transducers to enable low-loss signal transmission over long distances. Although various designs and demonstrations have achieved high-efficiency and low-added-noise transducers, a coherent photonic link between separate refrigerators has not yet been realized. Here, in this work, we experimentally demonstrate coherent signal transfer between two superconducting circuits housed in separate dilution refrigerators, enabled by a pair of frequency-matched aluminium nitride electro-optic transducers connected via a 1-km telecom optical fibre. The optical frequency matching between two transducers is realized by an asymmetric photonic molecule design, and an overall 80 dB improvement in transduction efficiency over commercial electro-optic modulators is achieved, paving the way towards a fully quantum-enabled link. This work provides critical design guidelines for scalable superconducting quantum networks interconnected by photonic links.

nonlinear optics↗

Cyclic superconducting refrigerators using guided fluxon propagation

We propose cyclic refrigeration in solid state, employing a gas of magnetic field vortices in a type-II superconductor—also known as fluxons—as the cooling agent. Refrigeration cycles are realized by envisioning a racetrack geometry consisting of both adiabatic and isothermal arms, etched into a type-II superconductor. The guided propagation of fluxons in the racetrack is achieved by applying an external electrical current, in a Corbino geometry, through the sample. A gradient of magnetic field is set across the racetrack allowing one to adiabatically cool down and heat up the fluxons, which subsequently exchange heat with the cold and hot reservoirs, respectively. We characterize the steady state of refrigeration cycles thermodynamically for both s -wave and d -wave pairing symmetries, and present their figures of merit such as the cooling power delivered, and the coefficient of performance. Our cooling principle can offer significant cooling for on-chip microrefrigeration purposes, by locally cooling below the base temperatures achievable in a conventional dilution refrigerator. We estimate n W / m m 2 of cooling power per unit area assuming a tunnel coupling with ∼ M Ω µ m 2 specific resistance. Integrating the fluxon fridge to quantum circuits can enhance their coherence time by locally suppressing thermal fluctuations, and improve the efficiency of single photon detectors and charge sensors. Published by the American Physical Society 2024

Karmakar, Tathagata (ORCID:0000000187812017)↗

ANALYSIS OF SUITABLE METHODOLOGIES FOR COMPRESSOR MASS FLOW RATE CORRECTION TO OTHER SUPERHEAT LEVELS AND REFRIGERANTS

This paper investigates the impact of suction conditions and refrigerant on scroll compressor mass flow rate by using calorimeter tests from AHRI-11 and AHRI-21 reports, published by AHRI's Low-GWP Alternative Refrigerants Evaluation program. Two Copeland scroll compressors (20 and 51 cm3) have been analyzed including different suction conditions (SH = 11K, SH = 22K, Ti = 18ºC) and several refrigerants (R134a, R32, R410A, R404A, etc.). Previous studies have explored response surfaces for energy consumption and mass flow rate variables. This study aims to expand the analysis by identifying the optimal approach to extrapolate mass flow rate from specific suction conditions to others SH or suction temperature levels and refrigerants. The current compressor characterization standard relies on the 1981 Dabiri correlation to correct compressor mass flow rate with suction conditions. Thus, this study aims to assess the adequacy of this correction and explore alternative correction methods for improved results.

Marchante Avellaneda, Javier↗

Gray-Box Fault Models and Applications for Low-Carbon Emission CO 2 Refrigeration Systems

CO 2 refrigeration systems have attracted more attentions in recent years because of their zero-carbon emission advantages compared with traditional refrigerants. These systems are widely used in certain commercial buildings such as supermarkets. However, very limited energy studies have been done for such refrigeration systems under faults. This study investigated five common faults for supermarket transcritical CO 2 refrigeration systems with display cases. The following major tasks were implemented for this study. (1) Five fault models (gray-box format) regarding the power consumption and supply air temperature were proposed for low- and high-temperature display cases, respectively. The models cover: ice accumulation on evaporator coil, evaporator fan partial failure, expansion valve failure, display door open, and condenser blockage. (2) These fault models were calibrated with field tests, and the modeling accuracies were in good agreement with measurement datasets. (3) The proposed fault models demonstrated more than 90% of fault detection for Fault Detection and Diagnostics (FDD) purposes for both field measurement and simulated data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building Technologies Office 03.02.02.38 Milestone Report — Technology Options for Low Environmental Impact Air-Conditioning and Refrigeration Systems

Due to increasing concerns about global warming, various environmental regulations will eventually phase out refrigerants used in air conditioning and refrigeration systems (e.g., R-410A, R-404A). Several refrigerants have been proposed as replacements, offering a variety of global warming potential (GWP), levels of energy efficiency and flammability. Some of these options are synthetic HFC/HFO mixtures such as R-454C and R-455A while other are commonly called naturals such as R-290 (Propane) and R-744 (Carbon Dioxide). This study discusses the merits of the leading options for air Conditioning and refrigeration systems. The fundamental requirements (environmental, performance, safety) are employed to fairly evaluate these options. Performance data and Life Cycle analysis results for these options are presented. Overall, this study provides information needed to judge the prospects of getting adequate replacement for R-410A and R-404A in a long-term sustainable basis.

42 ENGINEERING↗

Material Compatibility of 3D Printed Polymer Composites with Low GWP Refrigerants

The recent development of 3D printing brings numerous opportunities to develop polymer heat exchangers with desired configurations and allows access to the new complex engineering design for better performance. To be used in the HVAC&R system, the compatibility of these materials to refrigerants needs to be thoroughly investigated and understood. This study tested the material compatibility of the printed polymer composites according to the ASHRAE Guideline 38 using metal pressure vessels. These printed parts were tested with R-134A, R-1234YF, R-1234ZE, R-1233ZD(E), and 32-3 MAF POE (10 wt.%) was used as the lubricants. The change in volume, mass, hardness, and mechanical properties was studied in detail. Different compatibility of the composites with refrigerants was observed when the composition of the composite changed. After exposure to refrigerants, the morphological and thermal properties were studied with the scanning electron microscope, thermogravimetric analysis, and differential scanning calorimetry to further reveal the influence of these refrigerants.

Li, Kai↗

Optimization of a Residential Air Source Heat Pump using Refrigerants with GWP <150 for Improved Performance and Reduced Emission

Using low-GWP refrigerants can reduce the Green House Gas (GHG) emission of heat pump systems. Heat exchangers and compressors are the key components and have a prominent impact on system performance, significant research is devoted to reducing the cost of the heat exchangers while achieving the same or better system performance with refrigerant charge reduction.To better understand the environmental impacts of optimized systems with low-GWP refrigerants, Life Cycle Climate Performance (LCCP) evaluation method was used to evaluate the direct and indirect emissions of the system over the course of its lifetime from manufacturing to disposal. The DOE/ORNL Heat Pump Design Model (HPDM) is used to evaluate the performance of heat pumps. Multi-objective optimizations using Particle Swarm Optimization (PSO) algorithm are performed on a 3-ton R410A residential air source heat pump on market. Seven R410A alternatives, i.e., R32, R454B, R454C, R455A, R457A, R1234yf and R1234ze(E) are investigated. The last five fluids have GWP lower than 150.As a result, 5.5%-12.8% seasonal energy efficiency ratio 2 (SEER2) improvement is achieved, and the optimized systems reduce life cycle CO2 emission by 8.5%-28.6% with GWP lower than 150 refrigerants. The optimal heat exchangers can fit into the original R410A fan-coil units; therefore, the proposed design method establishes a production and installation path to produce cost-effective low-GWP heat pumps easily accepted by end users.

Li, Zhenning↗

Direct Expansion Heat Pump Using High Glide Low GWP Refrigerant

Next generation of refrigerants require drastically lower global warming potential (GWP). The refrigerant mixtures, with a GWP < 150, e.g., R-457A, etc., tend to have significant temperature glide, which prefer multi-row, cross counter flow configuration. Typical heat pump operation reverses the refrigerant flow direction, compared to the air flow, from cooling mode to heating mode. It is difficult to configurate cross counter-flow heat exchangers in heat pumps. We invented an innovative configuration, having check valve assembly to maintain uniform cross counter flow configuration in both cooling and heat modes, which optimizes the performance of a high temperature slide refrigerant mixture, i.e. R-457A. Based on it, we developed a laboratory prototype, using a 2-stage compressor, achieved a cooling SEER (cooling seasonal energy efficiency rating) of 16.0 (cooling seasonal COP of 4.69) and a heating HSPF (heating seasonal performance factor) > 9.5 (heating seasonal COP of 2.78). The unit was tested in an extensive ambient condition, heating operation from 5˚F to 62˚F (-15˚C to 16.7˚C); cooling operation from 82˚F to 95˚F (27.8˚C to 35˚C). The paper will introduce the system configuration, heat exchanger dimensions and laboratory investigations.

Shen, Bo↗

Experimental Study on Flow Condensation of Low Global Warming Potential Refrigerants in a Micro-fin Aluminum Tube

This study investigates the dynamic shifts in refrigerant technologies driven by environmental regulations, particularly emphasizing low global warming potential (GWP). Moreover, there is a rising trend in the adoption of aluminum tubes with internal axial micro-fin structures in heat exchangers to reduce costs. The research focuses on the condensation process within an expanded axial micro-fin aluminum tube with a 5.96 mm fin-tip diameter. Various refrigerants are analyzed, including both single compounds (R-32, R-1234yf, R-1234ze(E)) and zeotropic mixtures (R-454B, R-454C, R-455A). Experimental procedures cover a range of condensation temperatures (35~45 °C), reduced pressures (0.21~0.55), and mass fluxes (150~350 kg/(m² s)), providing crucial data on heat transfer coefficients (HTC) and frictional pressure gradient (FPG). This data is particularly significant for high-glide refrigerants and is instrumental in the design of advanced air conditioning and refrigeration systems aimed at mitigating global warming.

Hu, Yifeng↗

Theoretical analysis of a refrigerant injection-enhanced air source heat pump with thermal energy storage for extended cold-climate and defrosting operations

This study investigates a conceptual refrigerant injection-enhanced air source heat pump with integrated thermal energy storage (ITES-ASHP) that combines two-phase flash tank injection with phase change material (PCM) thermal energy storage (TES) to extend cold-climate operation and maintain indoor heating during defrost. A steady-state, mode-based thermodynamic cycle model is developed to evaluate heating and defrosting modes with and without refrigerant injection and TES integration over an outdoor temperature range of 8 to −25 °C. The framework is applied to refrigerants R-290, R-454B, R-410 A, and R-32. A parametric study is conducted for an 18-kW system rated for an outdoor temperature of 8 °C, with the compressor frequency scheduled to 150 Hz. The optimal PCM phase-change temperature is identified as 20 °C for R-290, R-454B, and R-410 A, and 15 °C for R-32. At the design condition of −25 °C outdoor temperature, the proposed concept achieves a combined COP of 2.22 for R-290, corresponding to a 60% increase relative to the theoretical single-stage baseline for combined heating and defrosting operation. Safety screening based on compressor discharge temperature (≤ 120 °C) and injection quality (≥ 0.65), together with performance evaluation, indicates that R-290 is the most suitable candidate, followed by R-410 A and R-454B. Under the assumptions and constraints used here, R-32 is found to be less suitable due to excessive discharge temperatures and a higher risk of wet compression.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

COVID 19 vaccine distribution solution to the last mile challenge: Experimental and simulation studies of ultra-low temperature refrigeration system

Most COVID-19 vaccines require ambient temperature control for transportation and storage. Both Pfizer and Moderna vaccines are based on mRNA and lipid nanoparticles requiring low temperature storage. The Pfizer vaccine requires ultra-low temperature storage (between -80 °C and -60 °C), while the Moderna vaccine requires -30 °C storage. Pfizer has designed a reusable package for transportation and storage that can keep the vaccine at the target temperature for 10 days. However, the last stage of distribution is quite challenging, especially for rural or suburban areas, where local towns, pharmacy chains and hospitals may not have the infrastructure required to store the vaccine. Also, the need for a large amount of ultra-low temperature refrigeration equipment in a short time period creates tremendous pressure on the equipment suppliers. In addition, there is limited data available to address ancillary challenges of the distribution framework for both transportation and storage stages. As such, there is a need for a quick, effective, secure, and safe solution to mitigate the challenges faced by vaccine distribution logistics. The study proposes an effective, secure, and safe ultra-low temperature refrigeration solution to resolve the vaccine distribution last mile challenge. Furthermore, the approach is to utilize commercially available products, such as refrigeration container units, and retrofit them to meet the vaccine storage temperature requirement. Both experimental and simulation studies are conducted to evaluate the technical merits of this solution with the ability to control temperature at -30 °C or -70 °C as part of the last mile supply chain for vaccine candidates.

60 APPLIED LIFE SCIENCES↗

Optimization of a Packed Particle Magnetocaloric Refrigerator: A Combined Experimental and Theoretical Study

Magnetocaloric refrigeration has strong potential towards achieving high efficiency hydrogen liquefaction. Optimising parameters such as particle size and operating cycles can have a significant impact on liquefaction performance. Here, this work reports on a room temperature magnetocaloric refrigeration prototype designed with helium as the heat transfer fluid and packed particle Gd 0.8875 Ce 0.1025 Si 0.84 Cr 0.19 as the refrigerant. The temperature spans and cooling power with three different particle sizes at two different operating cycles were measured. A maximum temperature span of 16.7 K and a maximum cooling power of 8.6 W·kg –1 were obtained. Reduction of performance in the faster cycle was observed in larger particles due to insufficient thermal diffusion time and its implications for cryogenic temperatures are discussed. A numerical model was developed based on the experimentally observed variation of the temperature span and cooling power with particle size and cycle duration. This model was then used to study the competing effects of viscous dissipation and thermal diffusion for different particle sizes and cycle durations.

08 HYDROGEN↗

Minimal two-body quantum absorption refrigerator

Here, we study the phenomenon of absorption refrigeration, where refrigeration is achieved by heating instead of work, in two different setups: a minimal set up based on coupled qubits and two nonlinearly coupled resonators. Considering ZZ interaction between the two qubits, we outline the basic ingredients required to achieve cooling. Using local as well as global master equations, we observe that inclusion of an XX type term in the qubit-qubit coupling is detrimental to cooling. We compare the cooling effect obtained in the qubit case with that of nonlinearly coupled resonators (multilevel system) where the ZZ interaction translates to a Kerr-type nonlinearity. For small to intermediate strengths of nonlinearity, we observe that multilevel quantum systems, for example qutrits, give better cooling effect compared to the qubits. Using Keldysh nonequilibrium Green's function formalism, we go beyond first order sequential tunneling processes and study the effect of higher order processes on refrigeration. We find a reduced cooling effect compared to the master equation calculations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Comparative Performance of Low Global Warming Potential (GWP) Refrigerants as Replacement for R-410A in a Regular 2-Speed Heat Pump for Sustainable Cooling

Heat pumps are currently being developed to reduce the energy footprint for residential and commercial building space conditioning and water heating loads in cold climates. To mitigate the nocuous impact of greenhouse gas emissions on the environment, and to create a carbon-neutral building stock, alternate lower-GWP refrigerants must also replace the predominant use of R-410A, without re-engineering the mechanical hardware. In this paper, we analyze the performance of lower-GWP alternative refrigerants (R-32, R-452B, R-454B, and R-466A) relative to the conventional R-410A and draw conclusions on the relative performances to meet cooling loads. The simulations are accomplished using the heat pump design model, a well-known, public-domain design tool with a free web interface and downloadable desktop version to support public use and the HVAC R&D community. The contributions contain detailed, hardware-based heat exchanger and system analyses to provide a comprehensive assessment. The results of the simulation are scrutinized from the first (capacity and energy efficiency) and second laws (exergy analysis) to identify sources of systemic inefficiency, the root cause of lost work. This rigorous approach provides an exhaustive analysis of alternate lower-GWP refrigerants to replace R-410A using the same hardware. The results have practical value in engineering heat pumps in an economy that is compelled to alter by the consequences and uncertainties of climate change, to reduce its anthropogenic carbon footprint.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Virtual refrigerant charge sensor for variable-speed heat pumps based on feature selection

The refrigerant charge level in heat pump systems significantly impacts their energy efficiency. Virtual refrigerant charge (VRC) sensing technology has been comprehensively investigated and well-established due to its lower cost compared to physical sensors. However, the previous VRC research often relied on expert judgment and physical reasoning for their variable selection, which can potentially select redundant (or highly correlated) or insignificant features, and it is also primarily focused on single-speed systems. To address these challenges, this study proposes a VRC algorithm for variable-speed heat pumps that selects features through a rigorous feature selection method in combination with physical insights. We also propose a piecewise linear model structure segmented by subcooling temperature to accurately predict charge levels, particularly when subcooling temperatures are substantially low. The proposed algorithm was evaluated using experimental data of a residential R410A heat pump, and the performance was compared with two baseline VRC algorithms. The results are: (1) The proposed algorithm outperforms for the case with subcooling temperature less than 1 °C. (2) The proposed algorithm achieves a tested mean absolute percentage error (MAPE) of 4.23%, and improves the overall accuracy for cooling conditions by approximately 60%, compared with the two baseline algorithms. (3) The proposed algorithm uses two fewer features and improves the accuracy for undercharge cooling conditions by 68.0%, compared with baseline algorithm 2. These improvements enhance prediction accuracy and prevent overfitting, providing a more reliable refrigerant charge level prediction and helping improve the heat pump energy efficiency.

Liang, Chenjiyu↗

Seasonal performance evaluation of zero-superheat active refrigerant charge control for variable-speed heat pumps

Heat pumps account for a significant portion of electricity consumption in buildings, making their energy efficiency a critical area of research. Control optimization is recognized as an effective approach for enhancing the efficiency of building HVAC systems. Specifically, since the efficiency of heat pumps increases with reduced superheat and the optimal refrigerant charge level varies with operating conditions, zero-superheat active charge control is a promising strategy to maximize the system’s COP. However, due to its complexity, this control strategy remains in the research phase and has only been tested under limited operating conditions. This paper proposes a methodology to evaluate the seasonal performance improvement of zero-superheat active charge control across a full range of heating conditions in buildings. The methodology includes the development of an optimal controller that utilizes an accumulator to store excess refrigerant and manages the active charge level at zero superheat through subcooling control, as well as the creation of a detailed physics-based heat pump model. Targeted a 3-ton variable-speed heat pump with R410A refrigerant, we selected ten U.S. cities representing different climate regions for seasonal performance evaluation. Our simulations indicate that, depending on the climate conditions, the optimal control strategy could achieve energy savings ranging from 5.8 % to 8.0 % over the entire heating season. These results suggest that zero-superheat active charge control, combined with coordinated compressor and fan speeds, could substantially improve the energy efficiency of heat pump systems while maintaining the required heating capacity.

Guo, Fangzhou↗