Zero Boil-Off Methods for Large Scale Liquid Hydrogen Tanks Using Integrated Refrigeration and Storage

NASA has completed a series of tests at the Kennedy Space Center to demonstrate the capability of using integrated refrigeration and storage (IRAS) to remove energy from a liquid hydrogen (LH2) tank and control the state of the propellant. A primary test objective was the keeping and storing of the liquid in a zero boil-off state, so that the total heat leak entering the tank is removed by a cryogenic refrigerator with an internal heat exchanger. The LH2 is therefore stored and kept with zero losses for an indefinite period of time. The LH2 tank is a horizontal cylindrical geometry with a vacuum-jacketed, multi-layer insulation system and a capacity of 125,000 liters. The closed-loop helium refrigeration system was a Linde LR1620 capable of 390W cooling at 20K (without any liquid nitrogen pre-cooling). Three different control methods were used to obtain zero boil-off: temperature control of the helium refrigerant, refrigerator control using the tank pressure sensor, and duty cycling (on/off) of the refrigerator as needed. Summarized are the IRAS design approach, zero boil-off control methods, and results of the series of zero boil-off tests.

ZBO↗

Surface acoustic wave sensor for refrigerant leakage detection

A SAW sensor is optimized for detection of refrigerant leakage in a refrigerant system or other gases, vapors, explosives or chemicals of interest. The SAW sensor includes a piezoelectric substrate; an interdigitated transducer deposited on the piezoelectric substrate, the interdigitated transducer having an input portion that receives input surface acoustic waves and an output portion that emits output surface acoustic waves; and a refrigerant sensor film located between the input portion and the output portion of the interdigitated transducer, the refrigerant sensor film including a sorbent material that is selected for preferential adsorption of a target refrigerant over atmospheric gases. Adsorption of the target refrigerant by the sorbent material results in a frequency shift of a frequency of the output surface acoustic waves relative to a frequency of the input surface acoustic waves. The sorbent material may be a metal organic framework (MOF) material, a covalent organic framework (COF) material, a porous organic cage or organic macrocyles such as calix [n] arene and its related derivatives.

Kunapuli, Raghuit Prasad↗

Multi-stage heat pump with two-phase injection for cold climate applications implementing natural refrigerants

Heat pump adoption in cold climates is limited by various technical challenges, including heat capacity degradation, compressor deterioration, and frost accumulation on the outdoor heat exchanger. Furthermore, wide-spread adoption of heat pumps with high global warming potential presents a possible environmental concern. Thus, we present a heat pump concept termed the “saturation cycle,” which uses numerous compression stages to improve energy efficiency and injects two-phase refrigerant between compression stages to dramatically reduce compressor discharge temperatures. Given the growing interest in heat pumps, there is a need for a straightforward framework for parametric evaluation of natural refrigerants in high-efficiency heat pump cycle architectures, like the saturation cycle, in adverse climates. This work develops a thermodynamic modeling framework and focuses on the application of natural refrigerants to explore the performance trends at extremely cold climates down to −25 °C. This study shows that a two-stage saturation cycle and four-stage saturation cycle can reduce the compressor discharge superheating by up to 51–57 % or 73–80 %, respectively, depending on the refrigerant. Furthermore, at −25 °C, a two-stage R-290 saturation cycle heat pump theoretically can use 25 % less power than a single-stage heat pump or can provide up to 59 % more heating capacity when using the same compressor power as the baseline single-stage heat pump. The exergetic parametric analyses show that two-phase refrigerant injection fundamentally improves the thermodynamic performance of the heat pump, reducing overall exergy destruction by 10 % compared to a vapor-injection heat pump, compared at −25 °C. Thus, the saturation cycle is a promising heat pump cycle architecture for cold climate applications due to its superior energy savings (or capacity improvement) and substantial de-superheating capabilities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impact of refrigerant undercharge faults on building indoor conditions and HVAC system operation in residential Buildings: A simulation study

This study investigates the impact of refrigerant undercharge on indoor temperature and HVAC system performance in residential buildings. Simulation models for typical residential buildings in Orlando, FL and Indianapolis, IN were developed using the ResStock database. A refrigerant undercharge fault model was then applied to the simulations with varying levels of fault intensity. The paper offers an extensive analysis, revealing that variations in supply air temperature, equipment runtime, and cooling energy consumption due to the level of refrigerant undercharge faults are notably significant on a summer representative day. Similarly, on a winter representative day, changes in supply air temperature and runtime are significant as well as changes in supplemental heat energy consumption. We find that occupants may remain oblivious to these faults during the cooling season, particularly when the HVAC system is oversized; in that case, supply air temperature data could help detect a fault. Another challenge is that during the heating season, when the supplemental heater operates, it is difficult to identify a refrigerant undercharge fault using only indoor and supply air temperature data. Finally, this study finds that supply air temperature, equipment runtime, and supplemental heater energy consumption data can help in detecting refrigerant undercharge faults.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Phase change material-to-refrigerant heat exchangers: Experimental validation and uneven melting analysis

Thermal energy storage (TES) using phase change materials (PCMs) enables load shifting and reduces mismatches between the building's thermal demand and the heat pump (HP) system's thermal capacity. While most TES studies have focused on single-phase heat transfer fluids, PCM-to-refrigerant heat exchangers (PRHX), in which the refrigerant undergoes liquid-vapor phase change, remain largely underexplored. Here, to address this gap, this study systematically investigates a shell-and-tube PRHX operating as the condenser in an HP through experiments and simulations. A two-dimensional enthalpy-based finite-volume PRHX model was developed and validated against experimental data, including refrigerant and PCM temperature profiles, PRHX capacity, and system-level performance. Results show three characteristic stages: Stage I, the condenser temperature rapidly increases with PCM in the solid state absorbing sensible heat; Stage II, stable operation during PCM phase change; and Stage III, performance decline once part of the PCM becomes fully melted. Heat transfer analysis revealed that uneven PCM melting along the condenser length was driven primarily by variations in the refrigerant-side heat transfer coefficient, rather than local approach temperature differences. Further study demonstrated that minimizing refrigerant outlet subcooling led to more uniform PCM melting and extended Stages I and II by up to 89%. This paper provides a validated PRHX model, clarifies the mechanisms of uneven PCM melting, and highlights subcooling control as an effective strategy to improve TES performance in HP systems without requiring secondary loops.

Graphite matrix↗

In tube condensation of low global warming potential refrigerants in an axial micro-fin aluminum tube

Environmental regulations have driven the development of refrigerants with low global warming potential (GWP). To design heat exchangers using these new refrigerants, data are needed concerning the heat transfer coefficient and pressure drop in two-phase flow. Another change is the increasing use of aluminum tubes rather than copper tubes to reduce heat exchanger cost. Hence, this study presents an experimental investigation of flow condensation using an expanded axial micro-fin aluminum tube with a fin-tip diameter of 5.96 mm. Here, the experiments included single compounds R-32, R-1234yf, and R-1234ze(E), zeotropic mixtures with low glide (R-454B), and zeotropic mixtures with high-glide (R-454C and R-455A). Experiments were conducted at condensation temperatures ranging from 40 °C to 50 °C, reduced pressures ranging from 0.21 to 0.55, and mass fluxes ranging from 150 to 350 kg/(m 2 s). Data obtained for these refrigerants constitute one of the first reports for high-glide refrigerants using axial micro-fin aluminum tubes. An evaluation of heat transfer degradation of zeotropic mixtures due to mass transfer resistance at the liquid/vapor interface is presented. This information can be used to design heat exchangers for next generation air conditioning and refrigeration systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Guide for Creating a Building-Level Action Plan to Manage Refrigerants in Buildings

The Guide for Creating a Building-Level Action Plan to Manage Refrigerants in Buildings has been developed in response to stakeholder feedback and interest received during the Better Buildings Managing Refrigerants Working Group. This guide includes best practices and a step-by-step guide to create a plan to manage their organization's refrigerants. Stakeholders were interested in guidance for refrigerant management to help reduce costs and protect efficiency of equipment, to mitigate risk related to increased maintenance and operational budgets, and to manage costs of using legacy refrigerants.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Review of Sensing Technologies for New, Low Global Warming Potential (GWP), Flammable Refrigerants

Commercial refrigeration systems currently utilize refrigerants with global warming potential (GWP) values ranging from 1250 to 4000. The advent of low GWP alternatives (GWP <150) is expected to significantly curtail direct emissions from this segment and greatly influence the ongoing electrification and decarbonization efforts. Most of the low GWP alternatives exhibit flammability risk and hence require robust sensing solutions for a reliable and safe operation of the equipment. This review article aims to provide an overview of different sensing mechanisms suitable for potential applications in systems employing flammable refrigerants, particularly those designated as A2L class. A summary of different A2L refrigerants and their properties is provided followed by a broad review of different classes of sensors, their working principle, transduction method, features, advantages, and limitations. Additionally, key performance characteristics of accuracy, selectivity, sensitivity, dynamic characteristic, and durability among other properties are discussed. Finally, areas of improvement and corresponding approaches are suggested for potential sensors in the successful adoption of A2L class refrigerants.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Influence of Thermal Energy Storage Integration Strategy on System Performance and Refrigerant Charge for Small-Scale R290 Heat Pumps

As small-scale (2.5 – 5 kW) heat pumps across the US increase straining the grid during peak hours, integrated heat pump thermal energy storage (HP-TES) systems can assist by load shifting. However, challenges arise when assembling these systems, as direct refrigerant-phase change material (PCM) heat exchangers (HXs) increase refrigerant charge, and indirect secondary loops degrade HP-TES performance. In this work, direct and indirect HP-TES configurations were sized using commercially available HXs to compare the available load shift time and performance at similar refrigerant charges. For the same indirect 5 kW HP-TES refrigerant charge, directly HP-TES can operate up to 72 and 145 minutes in cooling and heating modes, respectively, using small diameter tubes. Using Modelica, COP increases for direct and indirect HP-TES were 22% and 9%, respectively, given the parasitic losses in the indirect HP-TES. Overall, small-scale direct HP-TES can have comparable refrigerant charges with indirect HP-TES maximizing COP improvements.

25 ENERGY STORAGE↗

Condensation heat transfer and pressure drop of low-global warming potential refrigerants in smooth aluminum tubes

In this work we report condensation heat transfer coefficient and pressure drop data for R-454B, R-32, and R-454C. These refrigerants are low Global Warming Potential (GWP) replacements for R-410A. We obtained these data in a smooth 7.2 mm outer diameter (5.94 mm inner diameter) aluminum tube. In these experiments, the key variables were condensation temperature (35 °C ≤ T cond ≤ 50 °C) and refrigerant mass flux (151.1 ≤ G ≤ 347.3 kg m –2 s –1 ). In general, for similar nominal operating conditions, we measured the highest heat transfer coefficients for R-32 and the lowest for R-454C. Among the correlations we used to predict the heat transfer data for all three refrigerants, the one developed by Thome et al. (2003) predicted the data with the greatest accuracy. Deviations between experimental data and predictions of this correlation were 21.7% for R-454B (with SBG correction), 22.0% for R-32, and 18.8% for R-454C (with SBG correction). Experimental pressure gradient data were predicted by the Friedel correlation Friedel (1979) with deviations of 13.8% for R-454B, 9.8% for R-32, and 10.2% for R-454C. In this work, we also compare the predictions of the Cavallini et al. correlation Cavallini et al. (2006) for R-454B and R-32 in smooth copper versus smooth aluminum tubes. To improve this correlation’s predictive capability for aluminum tubes, we have proposed some modifications. After incorporating these modifications, the deviations between the correlation’s predictions and our data were 10% for R-454B (with SBG correction), 8.1% for R-32, and 5.2% for R-454C (with SBG correction). Furthermore, these data and findings will assist the HVAC and refrigeration industry to implement low-GWP refrigerants in condensers using smooth aluminum tubes.

Aluminum tube↗

Evaluation and optimization of flow boiling frictional pressure drop correlations using the data from traditional and next-generation refrigerants in a micro-fin tube

This study presents an experimental evaluation and optimization of flow boiling frictional pressure drop correlations for conventional and next-generation refrigerants in a horizontal micro-fin tube, with particular emphasis on the newly emerging refrigerant blends R-454C and R-455A, for which pressure-drop data in enhanced tubes remain limited. Experiments were conducted with R-410A, R-454C, R-455A, R-134a, R-1234yf, and R-1234ze(E) in a copper micro-fin tube with an inner diameter of 8.468 mm, over mass fluxes ranging from 100 to 300 kg/(m²·s) depending on the refrigerant, and evaporation temperatures of 7, 12, and 14 °C. Frictional pressure gradients were determined from measured total pressure drops after subtracting acceleration pressure drop, and the resulting database was used to assess four existing models: Kuo and Wang (1996), Cavallini et al. (1997), Goto et al. (2001), and Diani et al. (2014). The measured frictional pressure gradient increased with vapor quality and mass flux for all refrigerants and increased further at lower evaporation temperatures, with the overall trend strongly related to liquid viscosity. Among the four correlations, the Goto et al. (2001) model provided the best overall agreement with the measured data before optimization. To further improve prediction accuracy, the Kuo and Wang (1996) and Goto et al. (2001) models were optimized using the complete experimental database. After optimization, both models reduced the overall mean absolute deviation to below 15%, while the optimized Goto et al. (2001) model maintained the best and most consistent overall performance. The results provide new pressure-drop data for next-generation refrigerants and demonstrate that parameter optimization can significantly enhance the applicability of existing micro-fin-tube correlations.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

International review of market trends, technologies and policies for commercial refrigeration equipment and implications for China

This report reviews the latest global and China-specific market trends as well as latest technology and policy trends related to commercial refrigeration equipment, with emphasis on refrigerated display cabinets. Section 2 reviews the global and China market trends for commercial refrigeration equipment. Section 3 presents the latest technology options for improving energy performance and compares global Best Available Technologies (BAT) to regional and China-specific baselines, and discusses low-GWP refrigerant options for commercial refrigeration equipment. Section 4 reviews global energy efficiency standards and labeling programs, and compares international efficiency standard requirements with China’s proposed and existing standard requirements. Section 5 ends with a review of key findings and conclusions.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Quantum Computing – Real-Time Data Processing from a Dilution Refrigerator

This poster presents a real-time data visualization system for monitoring and displaying data from a Bluefors control unit connected to a dilution refrigerator. The goal is to provide an aesthetically pleasing and user-friendly web-based interface that continuously updates and displays critical data such as temperature and flow rates at various points within the refrigerator. Leveraging WebSocket technology, the system establishes multiple connections to the dilution refrigerators, enabling simultaneous monitoring of several units. The interactive webpage dynamically updates the data, providing researchers and operators with instant insights into the system's performance. The system's ability to stream and visualize data in real-time enhances the understanding of the dilution refrigerator's behavior, aiding in optimizing its operation and ensuring efficient scientific experiments. The application's web-based nature makes it easily accessible from any device with internet connectivity, promoting seamless collaboration and remote monitoring capabilities. Overall, this poster offers a comprehensive solution for real-time data visualization and analysis of dilution refrigerators, catering to the needs of researchers and scientists working in low-temperature physics and quantum computing fields.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Solid State Quantum Refrigeration Superconducting, Absorption and Measurement Based (Final Technical Report)

During this DOE grant, DE-SC0017890, in place for the past six years, all proposed research was carried out and published in peer-reviewed papers, as well as other projects that emerged during the research. In that effort the research team accomplished all proposed research, as well as many closely related research projects discovered and conceived of during the grant. These works included “Efficient Quantum Measurement Engines”, a work published in Physical Review Letters, giving a theory of quantum measurement-based engines, which uses quantum measurement as a resource. These engines are designed to efficiently convert energy from the stochastic quantum measurement process into useful work. Further publications include “Experimental Realization of a Quantum Dot Energy Harvester”, a joint theory and experimental work in collaboration with the group of Charles Smith in Cambridge, UK, as well as long time theoretical collaborators, Rafael Sánchez and Björn Sothmann. This work, featured as an Editor’s Suggestion in Physical Review Letters, realized an earlier theoretical proposal of ours, whereby two resonant tunneling quantum dots are connected to a central electronic cavity that is heated by a hot energy source. We also published “Superconducting Quantum Refrigerator: Breaking and Rejoining Cooper Pairs with Magnetic Field Cycles” a work done in collaboration with experimentalist Francesco Giazotto from ENS Pisa, Italy, which also resulted in a patent. This paper, published in Phys. Rev. Applied, advanced the concept of a cyclic fridge based on the normal/superconducting phase transition together with layered materials separated by tunnel junctions. We also completed the proposed research on a heat transistor, publishing “Thermal transistor and thermometer based on Coulomb-coupled conductors”, carried out as a collaboration between my group and theorists Splettstoesser (Lund U., Sweden), Sothmann (U. Duisburg-Essen, Germany), and Sánchez (U. Autónoma de Madrid, Spain). We carried out an analysis of a quantum coupled to a quantum point contact as a sensitive thermometer and heat transistor. We found the optimal statistical estimator for the temperature and compared it with experiments on the same type of devices. We also investigated autonomous quantum absorption refrigerators using quantum dots to cool by using a very hot thermal reservoir to drive heat between two other reservoirs. In the article “Quantifying the quantum heat contribution from a driven superconducting circuit”, we demonstrated that for a driven superconducting circuit, we showed heat flow provided by a hot source to the qubit can be switched on and off by varying external parameters, the frequency and the intensity of the driving. In the work “Stochastic thermodynamic cycles of a mesoscopic thermoelectric engine”, we reconsidered the autonomous thermoelectric heat engine in terms of underlying cycles. Rather than periodic behavior, the cycles were stochastic in nature. Nevertheless, by undertaking a graph theoretical analysis of the elementary transport processed, great quantitative and qualitative insight could be found. We also considered the quantum measurement process and showed that a quantum version of Maxwell’s demon could be related to the work extraction of a quantum system, closely related to arrow-of-time measures for quantum measurement, as described in our article “Thermodynamics of quantum measurement and Maxwell's demon's arrow of time”. This work was selected in Phys. Rev. A as an Editor’s Suggestion. A recent preprint titled “Cyclic Superconducting Quantum Refrigerators Using Guided Fluxon Propagation” accomplished an important piece of this grant: to propose a new kind of quantum refrigerator using the dynamics of fluxons in a type II superconductor. This invention envisioned a race-track type geometry where fluxons are confined. By applying a gradient of magnetic field together with electric current in a Corbino geometry, the circulating fluxons can actively cool a cold reservoir, realizing a new type of cyclic superconducting refrigerator. We also investigated the possibility of thermal control from different points of view. The application of quantum measurement to the system gives a new kind of control on the system of interest – we have pioneered this approach and shown that measurement can boost the thermal power of quantum engines as described in “Continuous measurement boosted adiabatic quantum thermal machines”. The ability to have heat flows on demand is an outstanding challenge, and we have provided new solutions to this problem in Thermal control across a chain of electronic nanocavities” for a chain of electron cavities using gating voltage control. The control methods using qubit/qubit coupling to create absorption fridges at their most fundamental level have also been developed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Charge Reduction and Performance Analysis of a Heat Pump Water Heater Using R290 as a Refrigerant—A Field Study

Heat pump water heaters (HPWHs) are a proven technology for water heating that has been commercialized. The adoption of HPWHs for domestic and commercial water heating is growing rapidly because of their superior performance compared with alternative water heating methods. Whereas most existing systems use R-134a as a working refrigerant, R290 has gained major attention owing to its superior thermodynamic properties. The goal of the current study is to assess the performance of residential HPWH with R290 as a direct refrigerant replacement for R134a. Two units of a 50 gal HPWH were used in this experimental study. A baseline unit contained R134a refrigerant, and a prototype unit contained R290 refrigerant. The prototype unit was developed through the modification of a commercially available HPWH unit to achieve a low charge of R290 refrigerant. Another major modification was the replacement of the baseline compressor with a compressor designed for R290. Tests were conducted in a field environment (a research and demonstration house) using programmed drawn profiles daily. The prototype that reduced the charge by 43–47% provided displayed performance comparable to the baseline unit regarding first-hour rating (FHR) and the uniform energy factor (UEF).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of a refrigeration system for lunar surface and spacecraft applications

An evaluation of refrigeration devices suitable for potential lunar surface and spacecraft applications was performed. The following conclusions were reached: (1) the vapor compression system is the best overall refrigeration system for lunar surface and spacecraft applications and the single phase radiator system is generally preferred for earth orbit applications, (2) the vapor compression cycle may have some application for simultaneous heating and cooling, (3) a Stirling cycle refrigerator was selected for the manned cabin of the space shuttle, and (4) significant increases in payload heat rejection can be obtained by a kit vapor compression refrigerator added to the shuttle R-21 loop. The following recommendations were made: (1) a Stirling cycle refrigerator may be used for food freezer and biomedical sample storage, (2) the best system for a food freezer/experiments compartment for an earth orbit space station has not been determined, (3) a deployed radiator system can be designed for large heat loads in earth orbit.

Copeland, R. J.↗

Life test performance of a Philips rhombic-drive refrigerator with bellows seals

In February 1979, tour Stirling cycle cryogenic refrigerators, developed by Philips Laboratories for the John Hopkins University/Applied Physics Laboratory, were launched into orbit aboard the P78-1 spacecraft. The refrigerators were designed to cool the detectors of two identical gamma-ray spectrometers to 77 K reliably for one year. Since launch, the refrigerators, still in orbit, have individually accumulated from 5,000 to over 20,000 hours of operation. As part of those efforts, a refrigerator identical to those in orbit was built, with one significant modification: flexible metal bellows between the crankcase and the working volume to prevent possible contaminants from migrating into the cold region. During the life test of the modified refrigerator, the temperature increase during the first three month run was 0.022 k/day, a negligible level. As of October 1982, the unit has accumulated over 12,300 hours of operation.

Lindale, E.↗

Magnetic Refrigeration Development

Magnetic refrigeration is being developed to determine whether it may be used as an alternative to the Joule-Thomson circuit of a closed cycle refrigerator for providing 4 K refrigeration. An engineering model 4-15 K magnetic refrigerator has been designed and is being fabricated. This article describes the overall design of the magnetic refrigerator.

Deardoff, D. D.↗