At least 91 records · Page 5

Development Efforts for Detritiating Legacy Heavy Water Moderator

Conclusions • Department of Energy is evaluating reclaiming contaminated heavy water to commercial virgin heavy water specifications • SRNL evaluated leading commercial technologies to detritiate heavy water • To minimize the process hazards, water distillation was proposed as the best candidate • Addition of LPCE and cryogenic distillation can help process 100% of water with little to no waste storage • Significant advances over the past 40 years, but demonstration system needed to prove necessary detritiation factors for heavy water

Angelette, Lucas M. [Savannah River National Labor↗

Vacuum distillation: vapor filtered-catalytic oxidation water reclamation system utilizing radioisotopes

The development of a functional model water reclamation system is discussed. The system produces potable water by distillation from the urine and respiration-perspiration condensate at the normal rate generated by four men. Basic processes employed are vacuum distillation, vapor filtration, vapor phase catalytic oxidation, and condensation. The system is designed to use four 75-watt isotope heaters for distillation thermal input, and one 45-watt isotope for the catalytic oxidation unit. The system is capable of collecting and storing urine, and provides for stabilizing the urine by chemical pretreatment. The functional model system is designed for operation in a weightless condition with liquid-vapor phase separators for the evaporator still, and centrifugal separators for urine collection and vapor condensation. The system provides for storing and dispensing reclaimed potable water. The system operates in a batch mode for 40 days, with urine residues accumulating in the evaporator. The evaporator still and residue are removed to storage and replaced with a fresh still for the next 40-day period.

Honegger, R. J.↗

Automatic mapping of strip mine operations from spacecraft data

The author has identified the following significant results. Computer techniques were applied to process ERTS tapes acquired over coal mining operations in southeastern Ohio on 21 August 1972 and 3 September 1973. ERTS products obtained included geometrically-correct map overlays, at scales from 1:24,000 to 1:250,000, showing stripped earth, partially reclaimed earth, water, and natural vegetation. Computer-generated tables listing the area covered by each land-water category in square kilometers were also produced. By comparing these mapping products, the study demonstrates the capability of ERTS to monitor changes in the extent of stripping and reclamation. NASA C-130 photography acquired on 7 September 1973 when compared with the ERTS products generated from the 3 September 1973 tape established the categorization accuracy to be better than 90%. It is estimated that the stripping and reclamation maps and data were produced from the ERTS CCTs at a tenth of the cost of conventional techniques.

Rogers, R. H.↗

Determine utility of ERTS-1 to detect and monitor area strip mining and reclamation

The author has identified the following significant results. Computer techniques were applied to process ERTS tapes acquired over coal mining operations in southeastern Ohio on 21 August 1972 and 3 September 1973. ERTS products obtained included geometrically correct map overlays showing stripped earth, partially reclaimed earth, water, and natural vegetation. Computer-generated tables listing the area covered by each land-water category in square kilometers and acres were produced. By comparing these mapping products, the study demonstrates the capability of ERTS to monitor changes in the extent of stripping, success of reclamation, and the secondary effects of mining on the environment.

Rogers, R. H.↗

Characterization of spacecraft humidity condensate

When construction of Space Station Freedom reaches the Permanent Manned Capability (PMC) stage, the Water Recovery and Management Subsystem will be fully operational such that (distilled) urine, spent hygiene water, and humidity condensate will be reclaimed to provide water of potable quality. The reclamation technologies currently baselined to process these waste waters include adsorption, ion exchange, catalytic oxidation, and disinfection. To ensure that the baseline technologies will be able to effectively remove those compounds presenting a health risk to the crew, the National Research Council has recommended that additional information be gathered on specific contaminants in waste waters representative of those to be encountered on the Space Station. With the application of new analytical methods and the analysis of waste water samples more representative of the Space Station environment, advances in the identification of the specific contaminants continue to be made. Efforts by the Water and Food Analytical Laboratory at JSC were successful in enlarging the database of contaminants in humidity condensate. These efforts have not only included the chemical characterization of condensate generated during ground-based studies, but most significantly the characterization of cabin and Spacelab condensate generated during Shuttle missions. The analytical results presented in this paper will be used to show how the composition of condensate varies amongst enclosed environments and thus the importance of collecting condensate from an environment close to that of the proposed Space Station. Although advances were made in the characterization of space condensate, complete characterization, particularly of the organics, requires further development of analytical methods.

Muckle, Susan↗

Development of an Additively Manufactured Capacitive Humidity Sensor for the International Space Station

The ability to measure humidity on the International Space Station and other long-duration spaceflight missions is a crucial part of the onboard systems. For example, the Environmental Control and Life Support System (ECLSS) needs to know the amount of humidity in the air to make decisions about whether it should spend power to run the dehumidifier systems to attempt to reclaim that water. Other issues can arise if the humidity reaches too high of levels and condensation builds up on electrical components. With that in mind, it is vital that the spacecraft keeps spare sensors on board or has the ability to manufacture new sensors on demand. An additively manufactured sensor would be additionally beneficial because it would save space onboard that would normally be taken up by spares, save money from costly resupply missions, and allow the sensor to be constantly updated with the most effective design. This Technical Memorandum outlines a development process carried out to design, manufacture, and test an additively manufactured humidity sensor.

Chang, K. T.↗

Microbial distribution in the Environmental Control and Life Support System water recovery test conducted at NASA, MSFC

NASA/MSFC is developing a physical/chemical treatment system to reclaim wastewater for reuse on Space Station Freedom (SSF). Integrated testing of hygiene and potable water subsystems assessed the capability to reclaim water to SSF specifications. The test was conducted from May through July 1990 with a total of 47 days of system test operation. Water samples were analyzed using standard cultural methods employing membrane filtration and spread plate techniques and epifluorescence microscopy. Fatty acid methyl ester and biochemical profiles were used for microbial identification. Analysis of waste and product water produced by the subsystems demonstrated the effective reduction of viable microbial populations greater than 8.0E + 06 colony forming units (CFU) per 100 mL to an average of 5 CFU/100 mL prior to distribution into storage tanks.

Gauthier, J. J.↗

Microbial biofilm studies of the environmental control and life support system water recovery test for Space Station Freedom

NASA is developing a water recovery system (WRS) for Space Station Freedom to reclaim human waste water for reuse by astronauts as hygiene or potable water. A water recovery test (WRT) currently in progress investigates the performance of a prototype of the WRS. Analysis of biofilm accumulation, the potential for microbially influenced corrosion (MIC) in the WRT, and studies of iodine disinfection of biofilm are reported. Analysis of WRT components indicated the presence of organic deposits and biofilms in selected tubing. Water samples for the WRT contained acid-producing and sulfate-reducing organisms implicated in corrosion processes. Corrosion of an aluminum alloy was accelerated in the presence of these water samples; however, stainless steel corrosion rates were not accelerated. Biofilm iodine sensitivity tests using an experimental laboratory scale recycled water system containing a microbial check valve (MCV) demonstrated that an iodine concentration of 1 to 2 mg/L was ineffective in eliminating microbial biofilm. For complete disinfection, an initial concentration of 16 mg/L was required, which was gradually reduced by the MCV over 4 to 8 hours to 1 to 2 mg/L. This treatment may be useful in controlling biofilm formation.

Rodgers, E. B.↗

Factors influencing water quality in surface water and alluvial groundwaters downgradient of a reclaimed surface coal mine in the Powder River Basin of southeastern Montana, USA

Abstract Coal mining and reclamation can have a profound influence on hydrogeologic systems, with clear consequences for groundwater quality, yet their long-term influence on downgradient water quality over time following reclamation is less well documented. Geochemical trends were evaluated in water quality downgradient of a fully reclaimed landscape at the former Big Sky Mine in the Rosebud Creek watershed (southeastern Montana, USA), over a 3-year period (2020–2022), including bond release in 2022. Within 6 km downgradient from the reclaimed area, sulfate concentrations decreased from approximately 3500 to 1800 mg l −1 within the Miller Coulee alluvial aquifer. Major ions, δ 34 S SO4 values, and residence time tracers suggest that the observed decreases in sulfate concentration result from a combination of dilution by mixed-age inflows and incomplete transit of the high salinity plume from the mine boundary. Both bedrock and alluvial aquifers of the Rosebud Creek corridor contained contributions of millennia-old regional groundwater, which may serve to mitigate mine-derived high salinity waters. Rosebud Creek, which traverses the outflow zone of Miller Coulee in the study area, exhibited high sulfate concentrations during low flows and consistent downgradient increases in sulfate concentration. The possibility of plume dynamics in Miller Coulee suggests that the greatest water quality impacts may not yet have reached Rosebud Creek.

Keeshin, Skye I. (ORCID:0009000986449872)↗

A study of alternative methods for reclaiming oxygen from carbon dioxide and water by a solid-electrolyte process for spacecraft applications

Two alternative technical approaches were studied for application of an electrochemical process using a solid oxide electrolyte (zirconia stabilized by yttria or scandia) to oxygen reclamation from carbon dioxide and water, for spacecraft life support systems. Among the topics considered are the advisability of proceeding to engineering prototype development and fabrication of a full scale model for the system concept, the optimum choice of method or approach to be carried into prototype development, and the technical problem areas which exist.

Source record↗

Development of the Second Generation International Space Station (ISS) Total Organic Carbon Analyzer (TOCA)

The second generation International Space Station (ISS) Total Organic Carbon Analyzer s (TOCA) function is to monitor concentrations of Total Organic Carbon (TOC) in ISS water samples. TOC is one measurement that provides a general indication of overall water quality by indicating the potential presence of hazardous chemicals. The data generated from the TOCA is used as a hazard control to assess the quality of the reclaimed and stored water supplies on-orbit and their suitability for crew consumption. This paper details the unique ISS Program requirements, the design of the ISS TOCA, and a brief description of the on-orbit concept-of-operations. The TOCA schematic will be discussed in detail along with specific information regarding key components. The ISS TOCA was designed as a non-toxic TOC analyzer that could be deployed in a flight ready package. This basic concept was developed through laboratory component level testing, two moderate fidelity integrated system breadboard prototypes, a flight-like full scale prototype, as well as lessons learned from the inadequacies of the first unit. The result: a new TOCA unit that is robust in design and includes special considerations to microgravity and the on-orbit ISS environment. TOCA meets the accuracy needs of the ISS Program with a 1,000 to 25,000 g/L range, accurate to within +/-25%.

Clements, Anna L.↗

Water Processor Assembly Technology Development

The International Space Station (ISS) Water Processor Assembly (WPA) produces potable quality water from humidity condensate, carbon dioxide reduction water, water obtained from fuel cells, reclaimed urine distillate, shower, handwash and oral hygiene waste waters. This paper describes the WPA integration into the ISS Node 3. It details the substantial development history supporting the design and describes the WPA System characteristics and its physical layout.

Bagdigian, Robert↗

Processing of combined domestic bath and laundry waste waters for reuse as commode flushing water

An experimental investigation of processes and system configurations for reclaiming combined bath and laundry waste waters for reuse as commode flush water was conducted. A 90-min recycle flow was effective in removing particulates and in improving other physical characteristics to the extent that the filtered water was subjectively acceptable for reuse. The addition of a charcoal filter resulted in noticeable improvements in color, turbidity, and suds elimination. Heating and chlorination of the waste waters were investigated for reducing total organism counts and eliminating coliform organisms. A temperature of 335.9 K (145 F) for 30 min and chlorine concentrations of 20 mg/l in the collection tank followed by 10 mg/l in the storage tank were determined to be adequate for this purpose. Water volume relationships and energy-use rates for the waste water reuse systems are also discussed.

Hypes, W. D.↗

Preventing leaching from lead water pipes with electrochemistry: an exploratory study

Toxic levels of lead leaching from ageing water distribution infrastructure affect over 5000 public drinking water systems in the US. Pipe replacement, the most effective solution to this problem, is prohibitively expensive. Additionally, chemical conditioning of drinking water using orthophosphates, although cost-effective, does not quickly stop lead leaching once it has started. We propose a novel approach to stop lead leaching: to rapidly form an insoluble scale within lead pipes using an external power supply. We report on the feasibility of this approach by first anodizing lead coupons and lead pipes reclaimed from a local water distribution using a phosphate electrolyte and different potentials, pH values, and phosphate concentrations. We subsequently exposed these anodized lead coupons and pipes to synthetic tap water to evaluate their lead leaching rates. We found that polarizing lead coupons in the presence of a 0.05 M phosphate solution decreased lead leaching by up to a 100-fold, relative to leaching from polished bare lead. Similarly, polarizing the reclaimed lead pipes (with a preexisting scale) decreased lead leaching from an average of 36 ppb to 7 ppb. These results were observed when applying potentials that favor Pb(IV) formation, which resulted in the buildup of PbO 2 and Pb 5 (PO 4 ) 3 OH in both lead coupons and pipes. Our findings indicate that this novel technology has the potential to rapidly decrease equilibrium lead levels in tap water below the EPA action limit of 15 ppb, and thus deserves further exploration.

54 ENVIRONMENTAL SCIENCES↗

Phase III Integrated Water Recovery Testing at MSFC - Closed hygiene and potable loop test results and lesson learned

A series of tests has been conducted at the NASA Marshall Space Flight Center (MSFC) to evaluate the performance of a Space Station Freedom (SSF) pre-development water recovery system. Potable, hygiene, and urine reclamation subsystems were integrated with end-use equipment items and successfully operated for a total of 35 days, including 23 days in closed-loop mode with man-in-the-loop. Although several significant subsystem physical anomalies were encountered, reclaimed potable and hygiene water routinely met current SSF water quality specifications. This paper summarizes the test objectives, system design, test activities/protocols, significant results/anomalies, and major lessons learned.

Holder, Donald W., Jr.↗

Phase III integrated water recovery testing at MSFC - Partially closed hygiene loop and open potable loop results and lessons learned

A series of tests has been conducted at the NASA Marshall Space Flight Center (MSFC) to evaluate the performance of a predevelopment water recovery system. Potable, hygiene, and urine reclamation subsystems were integrated with end-use equipment items and successfully operated in open and partially closed-loop modes, with man-in-the-loop, for a total of 28 days. Several significant subsystem physical anomalies were encountered during testing. Reclaimed potable and hygiene water generally met the current Space Station Freedom (SSF) water quality specifications for inorganic and microbiological constituents, but exceeded the maximum allowable concentrations for Total Organic Carbon (TOC). This paper summarizes the test objectives, system design, test activities/protocols, significant results/anomalies, and major lessons learned.

Bagdigian, R. M.↗

Microbiological and corrosion analysis of three urine pretreatment regimes with titanium 6A1-4V

One objective of the water recovery test (WRT) performed at NASA's Marshall Space Flight Center (MSFC) for the environmental control and life support systems (ECLSS) of Space Station Freedom is to determine the ability of the water recovery system to reclaim urine for crew reuse. In the process, raw urine is pretreated using a commercially available oxidant, Oxone (Dupont), and sulfuric acid (to reduce ammonia), and pumped into a urine processing subsystem. A combination of sodium hypochlorite and sulfuric acid were also considered as an alternative pretreatment. The ability of these pretreatments, plus a third pretreatment of ozone, to reduce microbial levels in urine generated during testing of the water recovery system at MSFC was examined. In addition, the corrosion rate of weld and base metal specimens of titanium 6A1-4V, a candidate material for the water system of Space Station Freedom, was monitored in the presence of these pretreatments. Specimen surfaces were examined at completion of the 21-day test using scanning electron microscopy. Change in pH, color, turbidity, and odor were recorded over the course of the test.

Huff, Timothy L.↗