Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “raman”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Processing Raman Spectra of High-Pressure Hydrogen Flames

The Raman Code automates the analysis of laser-Raman-spectroscopy data for diagnosis of combustion at high pressure. On the basis of the theory of molecular spectroscopy, the software calculates the rovibrational and pure rotational Raman spectra of H2, O2, N2, and H2O in hydrogen/air flames at given temperatures and pressures. Given a set of Raman spectral data from measurements on a given flame and results from the aforementioned calculations, the software calculates the thermodynamic temperature and number densities of the aforementioned species. The software accounts for collisional spectral-line-broadening effects at pressures up to 60 bar (6 MPa). The line-broadening effects increase with pressure and thereby complicate the analysis. The software also corrects for spectral interference ("cross-talk") among the various chemical species. In the absence of such correction, the cross-talk is a significant source of error in temperatures and number densities. This is the first known comprehensive computer code that, when used in conjunction with a spectral calibration database, can process Raman-scattering spectral data from high-pressure hydrogen/air flames to obtain temperatures accurate to within 10 K and chemical-species number densities accurate to within 2 percent.

Nguyen, Quang-Viet↗

Enhanced Raman Microprobe Imaging of Single-Wall Carbon Nanotubes

We explore Raman microprobe capabilities to visualize single wall carbon nanotubes (SWCNTs). Although this technique is limited to a micron scale, we demonstrate that images of individual SWCNTs, bundles or their agglomerates can be generated by mapping Raman active elementary excitations. We measured the Raman response from carbon vibrations in SWCNTs excited by confocal scanning of a focused laser beam. Carbon vibrations reveal key characteristics of SWCNTs as nanotube diameter distribution (radial breathing modes, RBM, 100-300 cm(exp -1)), presence of defects and functional groups (D-mode, 1300-1350 cm(exp -1)), strain and oxidation states of SWCNTs, as well as metallic or semiconducting character of the tubes encoded in the lineshape of the G-modes at 1520-1600 cm(exp - 1). In addition, SWCNTs are highly anisotropic scatterers. The Raman response from a SWCNT is maximal for incident light polarization parallel to the tube axis and vanishing for perpendicular directions. We show that the SWCNT bundle shape or direction can be determined, with some limitations, from a set of Raman images taken at two orthogonal directions of the incident light polarization.

Hadjiev, V. G.↗

Simultaneous Conoscopic Holography and Raman Spectroscopy

A new instrument was developed for chemical characterization of surfaces that combines the analytical power of Raman spectroscopy with the three-dimensional topographic information provided by conoscopic holography. The figure schematically depicts the proposed hybrid instrument. The output of the conoscopic holographic portion of the instrument is a topographical map of the surface; the output of the Raman portion of the instrument is hyperspectral Raman data, from which the chemical and/or biological composition of the surface would be deduced. By virtue of the basic principles of design and operation of the instrument, the hyperspectral image data would be inherently spatially registered with the topographical data. In conoscopic holography, the object and reference beams of classical holography are replaced by the ordinary and extraordinary components generated by a single beam traveling through a birefringent, uniaxial crystal. In the basic conoscopic configuration, a laser light is projected onto a specimen and the resulting illuminated spot becomes a point source of diffuse light that propagates in every direction. The laser beam is rasterscanned in two dimensions (x and y) perpendicular to the beam axis (z), and at each x,y location, the pattern of interference between the ordinary and extraordinary rays is recorded. The recorded interferogram constitutes the conoscopic hologram. Of particular significance for the proposed instrument is that the conoscopic hologram contains information on the z coordinate (height) of the illuminated surface spot. Hence, a topographical map of the specimen is constructed point-by-point by rastering the laser beam in the x and y directions and correlating the x and y coordinates with the z information obtained from the interferograms. Conoscopic imaging is an established method, and conoscopic laboratory instruments for surface metrology are commercially available. In Raman spectroscopy of a surface, one measures the spectrum of laser light scattered inelastically from a laser-illuminated spot on the surface. The wavelengths of the inelastically scattered light differ from that of the incident laser beam by amounts that correspond to the energies of molecular vibrations. The resulting vibrational spectrum can be used to identify the molecules. Raman spectroscopy is a standard laboratory technique for identifying mineralogical, biological, and other specific chemical compositions.

Schramm, Harry F.↗

Airborne and Ground-Based Measurements Using a High-Performance Raman Lidar

A high-performance Raman lidar operating in the UV portion of the spectrum has been used to acquire, for the first time using a single lidar, simultaneous airborne profiles of the water vapor mixing ratio, aerosol backscatter, aerosol extinction, aerosol depolarization and research mode measurements of cloud liquid water, cloud droplet radius, and number density. The Raman Airborne Spectroscopic Lidar (RASL) system was installed in a Beechcraft King Air B200 aircraft and was flown over the mid-Atlantic United States during July August 2007 at altitudes ranging between 5 and 8 km. During these flights, despite suboptimal laser performance and subaperture use of the telescope, all RASL measurement expectations were met, except that of aerosol extinction. Following the Water Vapor Validation Experiment Satellite/Sondes (WAVES_2007) field campaign in the summer of 2007, RASL was installed in a mobile trailer for groundbased use during the Measurements of Humidity and Validation Experiment (MOHAVE-II) field campaign held during October 2007 at the Jet Propulsion Laboratory s Table Mountain Facility in southern California. This ground-based configuration of the lidar hardware is called Atmospheric Lidar for Validation, Interagency Collaboration and Education (ALVICE). During theMOHAVE-II field campaign, during which only nighttime measurements were made, ALVICE demonstrated significant sensitivity to lower-stratospheric water vapor. Numerical simulation and comparisons with a cryogenic frost-point hygrometer are used to demonstrate that a system with the performance characteristics of RASL ALVICE should indeed be able to quantify water vapor well into the lower stratosphere with extended averaging from an elevated location like Table Mountain. The same design considerations that optimize Raman lidar for airborne use on a small research aircraft are, therefore, shown to yield significant dividends in the quantification of lower-stratospheric water vapor. The MOHAVE-II measurements, along with numerical simulation, were used to determine that the likely reason for the suboptimal airborne aerosol extinction performance during theWAVES_2007 campaign was amisaligned interference filter. With full laser power and a properly tuned interference filter,RASL is shown to be capable ofmeasuring themain water vapor and aerosol parameters with temporal resolutions of between 2 and 45 s and spatial resolutions ranging from 30 to 330 m from a flight altitude of 8 km with precision of generally less than 10%, providing performance that is competitive with some airborne Differential Absorption Lidar (DIAL) water vapor and High Spectral Resolution Lidar (HSRL) aerosol instruments. The use of diode-pumped laser technology would improve the performance of an airborne Raman lidar and permit additional instrumentation to be carried on board a small research aircraft. The combined airborne and ground-based measurements presented here demonstrate a level of versatility in Raman lidar that may be impossible to duplicate with any other single lidar technique.

Whiteman, David N.↗

Design and Calibration of a Raman Spectrometer for use in a Laser Spectroscopy Instrument Intended to Analyze Martian Surface and Atmospheric Characteristics for NASA

This project's goal is the design of a Raman spectroscopy instrument to be utilized by NASA in an integrated spectroscopy strategy that will include Laser-Induced Breakdown Spectroscopy (LIBS) and Laser-Induced Florescence Spectroscopy (LIFS) for molecule and element identification on Mars Europa, and various asteroids. The instrument is to be down scaled from a dedicated rover mounted instrument into a compact unit with the same capabilities and accuracy as the larger instrument. The focus for this design is a spectrometer that utilizes Raman spectroscopy. The spectrometer has a calculated range of 218 nm wavelength spectrum with a resolution of 1.23 nm. To filter out the laser source wavelength of 532 nm the spectrometer design utilizes a 532 nm wavelength dichroic mirror and a 532 nm wavelength notch filter. The remaining scatter signal is concentrated by a 20 x microscopic objective through a 25-micron vertical slit into a 5mm diameter, 1cm focal length double concave focusing lens. The light is then diffracted by a 1600 Lines per Millimeter (L/mm) dual holographic transmission grating. This spectrum signal is captured by a 1-inch diameter double convex 3 cm focal length capture lens. An Intensified Charge Couple Device (ICCD) is placed within the initial focal cone of the capture lens and the Raman signal captured is to be analyzed through spectroscopy imaging software. This combination allows for accurate Raman spectroscopy to be achieved. The components for the spectrometer have been bench tested in a series of prototype developments based on theoretical calculations, alignment, and scaling strategies. The mounting platform is 2.5 cm wide by 8.8 cm long by 7 cm height. This platform has been tested and calibrated with various sources such as a neon light source and ruby crystal. This platform is intended to be enclosed in a ruggedized enclosure for mounting on a rover platform. The size and functionality of the Raman spectrometer allows for the rover to carry other mission critical devices. This project will be continued at NASA until the requirements are met for the expected initial 2020 launch date.

Lucas, John F.↗

Remote Measurement of Atmospheric Temperatures By Raman Lidar

The Raman shifted return of a lidar, or optical radar, system has been utilized to make atmospheric temperature measurements. These measurements were made along a horizontal path at temperatures between -20 C and +30 C and at ranges of about 100 meters. The temperature data were acquired by recording the intensity ratio of two portions of the Raman spectrum which were simultaneously sampled from a preset range. The lidar unit employed in this testing consisted of a 4 joule-10ppm laser operating at 694.3 nm, a 10-inch Schmidt-Cassegrain telescope, and a system of time-gated detection and signal processing electronics. The detection system processed three return signal wavelength intervals - two intervals along the rotational Raman scattered spectrum and one interval centered at the Rayleigh-Mie scattered wavelength. The wavelength intervals were resolved by using a pellicle beam splitter and three optical interference filters. Raman return samples were taken from one discrete range segment during each test shot and the signal intensities were displayed in digital format. The Rayleigh-Mie techniques. The test site utilized to evaluate this measurement technique encompassed a total path length of 200 meters. Major components of the test site included a trailer-van housing the lidar unit, a controlled environment test zone, and a beam terminator. The control zone which was located about 100 meters from the trailer was 12 meters in length, 2.4 meters in diameter, and was equipped with hinged doors at each end. The temperature of the air inside the zone could be either raised or lowered with respect to ambient air through the use of infrared heaters or a liquid-nitrogen cooling system. Conditions inside the zone were continuously monitored with a thermocouple rake assembly. The test path length was terminated by a 1.2 meter square array of energy absorbing cones and a flat black screen. Tests were initially conducted at strictly ambient conditions utilizing the normal outside air temperatures as a test parameter. These tests provided a calibration of the Raman intensity ratio as a function of' temperature for the particular optical-filter arrangement used in this system while also providing a test of' the theoretical prediction formulated in the design of the system. Later tests utilized zone temperatures above and below ambient to provide temperature gradient data. These tests indicate that ten shots, or one minute of' data acquisition, from a 100 meter range can provide absolute temperature measurements with an accuracy of + 30 C and a range resolution of about 5 meters. Because this measurement accuracy compares well with that predicted for this particular unit, it is suggested that a field-application system could be built with signif'icant improvements in both absolute accuracy and range.

Salzman, Jack A.↗

Implications of Deep UV Raman Spectra of Gypsum and Fe-Bearing Dust Mixtures for Gypsum Detectability by the SHERLOC M2020 Instrument

Key science objectives of the Mars2020 Scanning Habitable Environments with Raman & Luminescence for Organics & Chemicals (SHERLOC) instrument suite include identification and characterization of inorganic and bio-logic phases and investigation of the past habitability of Jezero crater [1, 2]. To fully interpret in situ data received from SHERLOC, databases of deep ultraviolet (DUV) Raman spectra from a wide variety of martian analogue materials are being developed by us and others [e.g., 3]. Ferrous and ferric iron are abundant on the martian surface in bas-alt and, depending on alteration and transport processes, its alteration products. Fe-bearing phases are important to characterize with respect to detect-ability by DUV Raman spectroscopy because they strongly absorb DUV radiation, thereby decreasing Raman peak intensity [3, 4]. Ca-sulfates and Fe-bearing minerals have been commonly detected on the martian surface [5, 6]. In this analogue study, we collected Raman spectra of mechanical mixtures of powders of hematite HMS3 (~120 nm discrete particle diameter [7]), palagonite HWMK919 (<5 μm size fraction [8]) and gypsum WD163 (<150 μm size fraction) t o ex-amine the detectability of gypsum in the presence of relatively finer-grained, Fe bearing material. Be-cause of the difference in particle diameters, hematite and palagonite powders act as surrogates for martian dust, coating at small concentrations and then enveloping larger gypsum particles.

N C Haney↗

Calibration of the SHERLOC Deep Ultraviolet Fluorescence–Raman Spectrometer on the Perseverance Rover

We describe the wavelength calibration of the spectrometer for the scanning of habitable environments with Raman and luminescence for organics and chemicals (SHERLOC) instrument onboard NASA’s Perseverance Rover. SHERLOC utilizes deep ultraviolet Raman and fluorescence (DUV R/F) spectroscopy to enable analysis of samples from the Martian surface. SHERLOC employs a 248.6 nm deep ultraviolet laser to generate Raman-scattered photons and native fluorescence emission photons from near-surface material to detect and classify chemical and mineralogical compositions. The collected photons are focused on a charge-coupled device and the data are returned to Earth for analysis. The compact DUV R/F spectrometer has a spectral range from 249.9 nm to 353.6 nm (200 cm1 to 12, 000 cm1) (with a spectral resolution of 0.296 nm (40 cm1)). The compact spectrometer uses a custom design to project a high-resolution Raman spectrum and a low-resolution fluorescence spectrum on a single charge-coupled device. The natural spectral separation enabled by deep ultraviolet excitation enables wavelength separation of the Raman/fluorescence spectra. The SHERLOC spectrometer was designed to optimize the resolution of the Raman spectral region and the wavelength range of the fluorescence region. The resulting illumination on the charge-coupled device is curved, requiring a segmented, nonlinear wavelength calibration in order to understand the mineralogy and chemistry of Martian materials.

Kyle Uckert↗

Perseverance’s Scanning Habitable Environments with Raman and Luminescence for Organics and Chemicals (SHERLOC) Investigation

The Scanning Habitable Environments with Raman and Luminescence for Organics and Chemicals (SHERLOC) is a robotic arm-mounted instrument on NASA’s Perseverance rover. SHERLOC has two primary boresights. The Spectroscopy boresight generates spatially resolved chemical maps using fluorescence and Raman spectroscopy coupled to microscopic images (10.1 μm/pixel). The second boresight is a Wide Angle Topographic Sensor for Operations and eNgineering (WATSON); a copy of the Mars Science Laboratory (MSL) Mars Hand Lens Imager (MAHLI) that obtains color images from microscopic scales (∼13 μm/pixel) to infinity. SHERLOC Spectroscopy focuses a 40 μs pulsed deep UV neon-copper laser (248.6 nm), to a ∼100 μm spot on a target at a working distance of ∼48 mm. Fluorescence emissions from organics, and Raman scattered photons from organics and minerals, are spectrally resolved with a single diffractive grating spectrograph with a spectral range of 250 to ∼370 nm. Because the fluorescence and Raman regions are naturally separated with deep UV excitation (<250 nm), the Raman region ∼ 800 – 4000 cm−1 (250 to 273 nm) and the fluorescence region (274 to ∼370 nm) are acquired simultaneously without time gating or additional mechanisms. SHERLOC science begins by using an Autofocus Context Imager (ACI) to obtain target focus and acquire 10.1 μm/pixel greyscale images. Chemical maps of organic and mineral signatures are acquired by the orchestration of an internal scanning mirror that moves the focused laser spot across discrete points on the target surface where spectra are captured on the spectrometer detector. ACI images and chemical maps (< 100 μm/mapping pixel) will enable the first Mars in situ view of the spatial distribution and interaction between organics, minerals, and chemicals important to the assessment of potential biogenicity (containing CHNOPS). Single robotic arm placement chemical maps can cover areas up to 7x7 mm in area and, with the < 10 min acquisition time per map, larger mosaics are possible with arm movements. This microscopic view of the organic geochemistry of a target at the Perseverance field site, when combined with the other instruments, such as Mastcam-Z, PIXL, and SuperCam, will enable unprecedented analysis of geological materials for both scientific research and determination of which samples to collect and cache for Mars sample return.

Rohit Bhartia↗

Raman spectroscopy of Ryugu particles and their extracted residues: Fluorescence background characteristics and similarities to CI chondrites

We present here an investigation of Ryugu particles recovered by the Hayabusa2 space mission and their extracted carbonaceous acid residues using Raman spectroscopy. Raman parameters of Ryugu intact grains and their acid residues are characterized by broad D (defect induced) and G (graphite) band widths, indicating the presence of polyaromatic carbonaceous matter with low thermal maturity. Raman spectra of Ryugu particles and CI (type 1) chondrites exhibit stronger laser-induced fluorescence backgrounds compared to Type 2 and Type 3 carbonaceous chondrites. The high fluorescence signatures and wide bandwidths of the D and G bands of Ryugu intact grains are similar to the Raman spectra observed in CI chondrites, reflecting the low structural order of their aromatic carbonaceous matter, and strengthening the link between Ryugu particles and CI chondrites. The high fluorescence background intensity of the Ryugu particles is due to multiple causes, but it is likely that the relative abundance of geometry-bearing macromolecular organic matter in total organic carbon contents makes a large contribution to the fluorescence intensities. Locally observed high fluorescence in the acid-extracted residues of Ryugu is due to nitrogen-bearing outlier phase. The high fluorescence signature is one consequence of the low degree of thermal maturity of the organic matter and supports evidence that the Ryugu particles have escaped significant parent body thermal metamorphism.

Ryugu particles↗

Raman Temperature and Density Measurements in Supersonic Jets

Prediction of flow-field properties in supersonic jets using computational fluid dynamics (CFD) code predictions has become routine; however, obtaining accurate solutions becomes more challenging when there is a significant temperature difference between the jet core and the ambient air and/or compressibility effects are significant. Benchmark sets of flow field property data are required in order to assess current CFD capabilities and develop better modeling approaches for these turbulent flow fields where accurate calculation of temperatures and turbulent heat flux is important. Particle Image Velocimetry (PIV), spontaneous rotational Raman scattering (SRS) spectroscopy and Background Oriented Schlieren (BOS) have been previously used to acquire measurements of the mean and root mean square (rms) velocities, the mean and rms gas temperatures and density gradients in subsonic jet flows and film cooling flows. In this work, the ability to measure density is added to the list of measurands available using the acquired Raman spectra. The suite of measurement techniques are now applied to supersonic jet flows. The computation of the local gas pressure in the potential core of an over-expanded jet is demonstrated using the Raman measured gas temperature and density. Additionally, a unique density feature in temperature matched, perfectly expanded jet flow shear layers identified using BOS was verified using the Raman measurement technique. These non-intrusive flow measurements are compared against RANS predictions of the supersonic jet flow properties as a means of assessing their prediction accuracy.

Raman Spectroscopy↗

Algorithmic Classification of Raman Spectra Biosignatures: Improving Life Detection Confidence

“Agnostic” biosignatures – indicators of life (or the absence of life), independent of a particular biochemistry – are increasingly considered a high standard for life detection. The Ladder of Life Detection (2018) called for investigating how combinations of independent and different potential biosignatures affect confidence. To address this gap, statistical classification of elemental abundances, isotopic fractionation, and reflectance spectroscopy (VNIR) has been implemented. Raman spectroscopy, highly desirable due to its wide availability, has the potential to improve this predictive power. This work implemented biosignature classification algorithms on Raman data alone, in preparation for combination with the other data types. Raman spectroscopy data was collected from published databases and papers as part of a manually curated dataset of “indicative” and “non-indicative of life” samples. These currently include 61 non-indicative samples (meteorites, magnetite); 3 indicative living samples (bacteria); 20 indicative non-living samples (chalk, bone); and 12 indicative mixed (with non-indicative material) samples (soil, microbial mats). Laboratory work is ongoing to characterize additional samples, particularly a greater breadth of mixed systems. Spectra were interpolated, filtered with the Savitzsky-Golay filter, and de-noised. For a preliminary examination, agnostic features were manually extracted including mean intensity, number of peaks, and mean peak width. Different peak prominences and filtering polynomials were used to refine features. Classification algorithms were implemented: k-nearest neighbors (KNN), logistic regression (LR), linear support vector machines (SVM), random forest (RF), Gaussian naïve bayes (GNB). Lastly, Monte Carlo simulations on 1,000 50%-train-test-splits were used to validate classification performance and feature significance. The preliminary feature set achieved its highest AUC of 0.52 with LR, with no strongly discriminatory features. Work to improve feature extraction, such as through deep learning with back propagation, is planned. In future work, the Raman data will be combined with the other data types, and potentially new data types such as enantiomeric excess. This project was partially supported through the NASA Ames Project EXcellence (APEX) incubator program.

Astrobiology↗

In-situ Raman Instrumentation and Measurements in Supercritical Water Oxidation Systems

Due to the advent of recent advances in reactor designs and operational procedures, renewed attention has been given to a host of supercritical water oxidation (SCWO) technology applications. This includes resource recovery, water reclamation, and solid waste destruction. SCWO is often recognized as a “green technology” because of its ability to extract useful energy while producing benign products from environmentally challenging waste streams (e.g., wet organic wastes, pharmaceutical wastes, military wastes). The present work was motivated by NASA’s interests in solid waste management and water recovery for long-duration space missions. To that end, the main focus of this paper is to present work on characterizing the behavior of supercritical water oxidation systems utilizing state of the art laser Raman spectroscopy. The main benefit of Raman diagnostics is its ability to identify chemical composition and to measure concentrations of the compounds involved in the reaction. Two separate Raman systems for SCWO measurements that have been developed for this study will be described. The first system is a 2-D traversing system useful for making in-situ measurements in conditions where spatial gradients of species and temperature are important and has been successfully utilized in making species (ethanol, oxygen, water, nitrogen and carbon dioxide) concentrations and temperature measurements in ethanol hydrothermal jet flames. The second system is a packaged modular Raman probe unit for portable deployment to different reactors and is more suitable for relatively homogeneous systems such as a batch reactor. The design, development, and examples of obtained results from both systems will be presented for various reactant streams. Reaction rate and fuel conversion estimates from chemistry models will also be presented.

supercritical water oxidation↗

The application of laser-Raman light scattering to the determination of sulfate in sea and estuarine waters

Laser-Raman light scattering is a technique for determining sulfate concentrations in sea and estuarine waters with apparently none of the interferences inherent in the gravimetric and titrametric methods. The Raman measurement involved the ratioing of the peak heights of an unknown sulfate concentration and a nitrate internal standard. This ratio was used to calculate the unknown sulfate concentration from a standard curve. The standard curve was derived from the Raman data on prepared nitrate-sulfate solutions. At the 99.7% confidence level, the accuracy of the Raman technique was 7 to 8.6 percent over the concentration range of the standard curve. The sulfate analyses of water samples collected at the mouth of the James River, Hampton, Virginia, demonstrated that in most cases sulfate had a constant concentration relative to salinity in this area.

Bandy, A. R.↗

Measurement of Raman spectra of H2O and SO4(-) in seawater

A study of applying laser Raman spectroscopy to remote sensing of the sulfate ion in sea water is in progress. The SO4 Raman spectrum has been obtained from true sea water samples in the laboratory using a CW laser Raman spectrometric system. Radiometric calculations indicate the feasibility of obtaining usable SO4 Raman signals in a field experiment. One of serious difficulties expected in the field experiment would be from fluorescence of phytoplankton and organics.

Houghton, W. M.↗

Remote sensing of subsurface water temperature by laser Raman spectroscopy

This paper describes experimental remote sensing of subsurface water temperature using the Raman spectroscopic technique. By the use of a pulsed laser and range gating detection techniques, Raman scattering is analyzed as a function of depth in a radar-like echo mode, and thus subsurface profiles of temperature and transmission are obtained. Experiments are described in which Raman data using polarization spectroscopy has been obtained from a ship as a function of depth in ocean water near Grand Bahama Island. A spectral temperature accuracy of + or - 1 C has been obtained from this data in the first two optical attenuation lengths. Raman data obtained from ocean water using the NASA airborne oceanographic lidar is also presented.

Leonard, D. A.↗

Remote Raman measurement techniques

The use of laser Raman measurement techniques in remote sensing applications is surveyed. A feasibility index is defined as a means to characterize the practicality of a given remote Raman measurement application. Specific applications of Raman scattering to the measurement of atmospheric water vapor profiles, methane plumes from liquid natural gas spills, and subsurface ocean temperature profiles are described. This paper will survey the use of laser Raman measurement techniques in remote sensing applications using as examples specific systems that the Computer Genetics Corporation (CGC) group has developed and engineered.

Leonard, D. A.↗

Absorption and resonance Raman spectra of Pb2, Pb3, and Pb4 in xenon matrices

Matrix isolation techniques are used to investigate the spectra of lead molecules and, in particular, to obtain resonance Raman spectra of lead vapors isolated in solid xenon matrices. The presence of Pb2 is confirmed by the visible adsorption, and Raman spectra yield a vibrational frequency for the ground state of 108 per cm and a dissociation energy of 8200 per cm. A second resonance Raman progression indicates a Pb3 species of D3h symmetry. Finally, two additional Raman features at approximately 111 per cm spacing are evidence for a third species, tentatively identified as Pb4.

Stranz, D. D.↗