Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “radiography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Radiography

Radiography is discussed as a method for nondestructive evaluation of internal flaws of solids. Gamma ray and X-ray equipment are described along with radiographic film, radiograph interpretation, and neutron radiography.

Gardner, C. G.↗

Evaluation of ultrasonics and optimized radiography for 2219-T87 aluminum weldments

Ultrasonic studies are described which are specifically directed toward the quantitative measurement of randomly located defects previously found in aluminum welds with radiography or with dye penetrants. Experimental radiographic studies were also made to optimize techniques for welds of the thickness range to be used in fabricating the External Tank of the Space Shuttle. Conventional and innovative ultrasonic techniques were applied to the flaw size measurement problem. Advantages and disadvantages of each method are discussed. Flaw size data obtained ultrasonically were compared to radiographic data and to real flaw sizes determined by destructive measurements. Considerable success was achieved with pulse echo techniques and with 'pitch and catch' techniques. The radiographic work described demonstrates that careful selection of film exposure parameters for a particular application must be made to obtain optimized flaw detectability. Thus, film exposure techniques can be improved even though radiography is an old weld inspection method.

Clotfelter, W. N.↗

Dual Use Corrosion Inhibitor and Penetrant for Anomaly Detection in Neutron/X Radiography

A dual purpose corrosion inhibitor and penetrant composition sensitive to radiography interrogation is provided. The corrosion inhibitor mitigates or eliminates corrosion on the surface of a substrate upon which the corrosion inhibitor is applied. In addition, the corrosion inhibitor provides for the attenuation of a signal used during radiography interrogation thereby providing for detection of anomalies on the surface of the substrate.

Hall, Phillip B.↗

Real-Time Digital Radiography Upgrade

The objective of the task is to upgrade an existing real-time digital radiography system by replacing an aged image intensifier tube with an amorphous silicon digital x-ray imager. The real-time digital radiography system at GSFC is currently fitted with image intensifier tube with a 4 or 2 inch diameter active area with higher resolution at the smaller area. The image intensifier is exhibiting deterioration in sensitivity associated with extended use and is in need of replacement.

Parker, Bradford H.↗

Application of Digital Radiography to Weld Inspection for the Space Shuttle External Fuel Tank

This slide presentation reviews NASA's use of digital radiography to inspect the welds of the external tanks used to hold the cryogenic fuels for the Space Shuttle Main Engines. NASA has had a goal of replacing a significant portion of film used to inspect the welds, with digital radiography. The presentation reviews the objectives for converting to a digital system from film, the characteristics of the digital system, the Probability of detection study, the qualification and implementation of the system.

Ussery, Warren↗

Using Digital Radiography To Image Liquid Nitrogen in Voids

Digital radiography by use of (1) a field-portable x-ray tube that emits low-energy x rays and (2) an electronic imaging x-ray detector has been found to be an effective technique for detecting liquid nitrogen inside voids in thermal-insulation panels. The technique was conceived as a means of investigating cryopumping (including cryoingestion) as a potential cause of loss of thermal insulation foam from space-shuttle external fuel tanks. The technique could just as well be used to investigate cryopumping and cryoingestion in other settings. In images formed by use of low-energy x-rays, one can clearly distinguish between voids filled with liquid nitrogen and those filled with gaseous nitrogen or other gases. Conventional film radiography is of some value, but yields only non-real-time still images that do not show time dependences of levels of liquids in voids. In contrast, the present digital radiographic technique yields a succession of images in real time at a rate of about 10 frames per second. The digitized images can be saved for subsequent analysis to extract data on time dependencies of levels of liquids and, hence, of flow paths and rates of filling and draining. The succession of images also amounts to a real-time motion picture that can be used as a guide to adjustment of test conditions.

Cox, Dwight↗

Terahertz Imaging and Backscatter Radiography Probability of Detection Study for Space Shuttle Foam Inspections

This slide presentation reviews the use of terahertz imaging and Backscatter Radiography in a probability of detection study of the foam on the external tank (ET) shedding and damaging the shuttle orbiter. Non-destructive Examination (NDE) is performed as one method of preventing critical foam debris during the launch. Conventional NDE methods for inspection of the foam are assessed and the deficiencies are reviewed. Two methods for NDE inspection are reviewed: Backscatter Radiography (BSX) and Terahertz (THZ) Imaging. The purpose of the Probability of Detection (POD) study was to assess performance and reliability of the use of BSX and or THZ as an appropriate NDE method. The study used a test article with inserted defects, and a sample of blanks included to test for false positives. The results of the POD study are reported.

Ussery, Warren↗

Corrosion Inhibitors as Penetrant Dyes for Radiography

Liquid/vapor-phase corrosion inhibitors (LVCIs) have been found to be additionally useful as penetrant dyes for neutron radiography (and perhaps also x-radiography). Enhancement of radiographic contrasts by use of LVCIs can reveal cracks, corrosion, and other defects that may be undetectable by ultrasonic inspection, that are hidden from direct optical inspection, and/or that are difficult or impossible to detect in radiographs made without dyes.

Novak, Howard L.↗

Analyzing the Subjectivity of Hole-Type Image Quality Indicators for Radiography

Hole-type penetrameters used as image quality indicators (IQIs) for radiography have an inherent degree of subjectivity to their interpretation. The 1T (one times the thickness of the penetrameter) hole is so small, it can be difficult to distinguish from noise. It is suspected that an operator’s knowledge of the true location of the 1T hole may subconsciously influence a false positive identification of the 1T hole when in fact it cannot be discerned. In the case of computed radiography (CR), the size of the phosphor particles may lead to a noise pattern with features on the scale of the 1T hole. Per NASA-STD-5009, the 1T hole must be detected in order to achieve adequate sensitivity. This is based on the historical understanding that this sensitivity will enable detection of the minimum detectable flaw sizes listed in the standard. It’s important to understand if 1T sensitivity is being achieved, and the associated risk if not. This study sought to determine the true detectability of 1T-sized holes in aluminum and Inconel by creating and inspecting a set of penetrameters with randomly placed holes. Enough holes and vacant zones were created to enable a full probability of detection study with 90% detectability, 95% confidence. Testing is ongoing, but preliminary results have shown poor detectability. The detection rate is slightly better for Inconel than aluminum, slightly better using a micro-focus vs. mini-focus tube, and definitively better for film than CR. One of the key questions of this study is whether historical requirements for film are applicable for CR, and these initial findings suggest they may not be. There is also a requirement in the NASA standard for the minimum contrast-to-noise ratio of the hole. The results have shown that this numerical threshold does not correlate well with visual detection. This raises questions about the true nature of detection, in an age of image processing vs. human judgement. As the results indicate that the detection of 1T holes is unreliable, the next challenge will be determining what sensitivity is really achieved, and what is needed.

Erin Lanigan↗

Analyzing the Subjectivity of Hole-Type Image Quality Indicators for Radiography

Hole-type penetrameters used as image quality indicators (IQIs) for radiography have an inherent degree of subjectivity to their interpretation. The 1T (one times the thickness of the penetrameter) hole is so small, it can be difficult to distinguish from noise. It is suspected that an operator’s knowledge of the true location of the 1T hole may subconsciously influence a false positive identification of the 1T hole when in fact it cannot be discerned. In the case of computed radiography (CR), the size of the phosphor particles may lead to a noise pattern with features on the scale of the 1T hole. Per NASA-STD-5009, the 1T hole must be detected in order to achieve adequate sensitivity. This is based on the historical understanding that this sensitivity will enable detection of the minimum detectable flaw sizes listed in the standard. It’s important to understand if 1T sensitivity is being achieved, and the associated risk if not. This study sought to determine the true detectability of 1T-sized holes in aluminum and Inconel by creating and inspecting a set of penetrameters with randomly placed holes. Enough holes and vacant zones were created to enable a full probability of detection study with 90% detectability, 95% confidence. Testing is ongoing, but preliminary results have shown poor detectability. The detection rate is slightly better for Inconel than aluminum, slightly better using a micro-focus vs. mini-focus tube, and definitively better for film than CR. One of the key questions of this study is whether historical requirements for film are applicable for CR, and these initial findings suggest they may not be. There is also a requirement in the NASA standard for the minimum contrast-to-noise ratio of the hole. The results have shown that this numerical threshold does not correlate well with visual detection. This raises questions about the true nature of detection, in an age of image processing vs. human judgement. As the results indicate that the detection of 1T holes is unreliable, the next challenge will be determining what sensitivity is really achieved, and what is needed.

Erin Lanigan↗

Scalable Detector Design for a High-Resolution Fast-Neutron Radiography Panel

Development of a scalable flat-panel neutron radiography device is needed to meet the nondestructive testing needs of a growing industrial market. Flood field images from a Cs-137 gamma source and a Cf-252 fission neutron source were generated using a detector composed of a 3-mm-thick sheet of EJ-200, and 3-mm-thick sheet of acrylic light spreader, an 8 $\times$ 8 array of SensL MICROFJ-60035-TSV SiPMs, and an IDEAS ROSSPAD readout module. The readout module can be tiled together with similar systems to create a panel of any size, and is only limited by the number of available Ethernet ports in a switching system. A collimated gamma line image demonstrated a 90% spatial resolution of approximately 0.47 line pairs per centimeter and a 10% spatial resolution of approximately 2.32 line pairs per centimeter. A neutron edge image demonstrated a 90% spatial resolution of approximately 0.70 line pairs per centimeter and a 10% spatial resolution of approximately 3.35 line pairs per centimeter. Both of these images show the ability to generate radiographs with sub-SiPM spatial resolution. Using these readout modules, a large-scale radiographic panel can be developed by tiling ROSSPAD modules together.

36 MATERIALS SCIENCE↗

Quantitative proton radiography and shadowgraphy for arbitrary intensities

Charged-particle radiography and shadowgraphy data can be directly inverted to obtain a line-integrated transverse Lorentz force or a line-integrated transverse refractive index gradient if intensity modulations due to scattering and absorption are negligible, and angular deflections are small. We develop a new direct-inversion algorithm based on plasma physics and compare it to a new Monge–Ampère code and an existing power diagram code. The measured or source intensity is represented by electrons subject to drag, and the other intensity by fixed ions. The decrease in kinetic plus electrostatic energy determines convergence. The displacement of the electrons from their initial to their equilibrium positions determines the line-integrated force or refractive index gradient. We have implemented two approaches: PIC (particle in cell) and Lagrangian fluid, in 1-D and 2-D. The PIC code works for arbitrary intensities, can work efficiently in parallel, and can make use of existing codes. The Lagrangian code requires less memory and is faster than the PIC code without massively parallel processing, but fails in 2-D for large intensity modulations. The Monge–Ampère code is by far the fastest in 2-D, without massively parallel processing, but fails for intensities with large voids, high contrast ratios and large deflections across the boundaries, and could not obtain the degree of convergence possible with the PIC code. As a result, the power diagram code was by far the slowest and most memory intensive, and failed for large peaks in the measured intensity.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

An Analysis of Input Parameters for Film-Based Flash X-Ray Radiography

Flash X-ray radiography (flash) is a commonly used diagnostic technique in dynamic experiments. An analysis of the effects of input parameters on resulting metrics of image quality can aid the experimentalist in configuring the X-ray input parameters to produce the highest quality radiograph for a given experiment. Here, a flash X-ray test bed with HS800 film and a LANEX Medium F intensifier screen was used with an L3 450 kVp pulser and Scandiflash X-ray tube for this study. Input parameters including charge voltage, source filtering, and film-pack assembly were investigated for their impact on contrast-to-noise ratio (CNR), contrast, and contrast transfer function (CTF). Using VIDAR’s NDT Pro industrial film digitizer, scanner parameters such as optical density range, pixel spacing, scan mode, and digital bit-depth were also examined for their impact on image quality metrics. The highest CNR values were found with two LANEX intensifiers and no filtering. Charge voltage had no direct impact on CNR values. LANEX screen count and filtering resulted both in direct effects on CNR and interaction effects with each other and CNR value. Uncertainty bounds for CNR comparisons and repeatability of CTF evaluations are also discussed. Finally, the film results are compared with a previous study using other detector types, specifically Carestream INDUSTREX Flex GP, Flex HR, Flex XL Blue, and HPX-DR 3543.

dynamic radiography↗

Detecting keyhole porosity and monitoring process signatures in additive manufacturing: an in situ pyrometry and ex situ X-ray radiography correlation

Creation of pores and defects during laser powder bed fusion (LPBF) can lead to poor mechanical properties and thus must be minimized. Post-build inspection is required to ensure the printed parts contain acceptably low defect concentrations. These inspections are time consuming and costly, especially for large or complex parts. As a potential solution, in situ process monitoring can be used to detect the creation of defects, characterize local material behavior and predict expected component properties. However, the precise relationship between pore creation and in situ process monitoring still needs to be understood. In this work, high-speed infrared diode-based pyrometry and high-speed optical imaging signals were used to monitor LPBF printing of 446 stainless steel 316 L single tracks with varying laser power and velocity. Results indicate an increase in pyrometer signal and melt pool dimensions with increasing laser power and decreasing velocity in agreement with previous work. In addition, careful analysis of pyrometer signal reveals a distinct signature of the conduction-to-keyhole mode transition which was confirmed by metallography. Critically, pore defect initiation as characterized by ex situ X-ray radiography was correlated with in situ thermal monitoring signals to derive the probability of defect creation. Our results show that, in principle, a probabilistic prediction of pore formation can be achieved based on in situ high-speed pyrometry monitoring of the LPBF melt pool.

36 MATERIALS SCIENCE↗

Monitoring steel fibre orientation in self-compacting cementitious composite slabs during pouring with dynamic X-ray radiography

This paper presents a new technique based on dynamic X-ray radiography that can be used to assess fibre orientation during pouring of steel fibre reinforced cementitious composites. Synthetic examples were used to assess the suitability and robustness of the technique, which was shown to provide reliable measurements of fibre orientation even when the signal-to-noise ratio is relatively high. A study was then carried out on the effect of formwork aspect ratio, time/duration of pouring, and rebar placement on the fibre orientation while pouring self-compacting cementitious composite slabs. Results demonstrated the ability of the technique in monitoring the movements of fibres while pouring, and the strong effect of the flow in inducing preferential fibre alignment within the slabs. Fibre orientation was found to vary progressively over time and could take about half of the duration of pouring to fully stabilise.

36 MATERIALS SCIENCE↗

Enhancement of high energy X-ray radiography using compound parabolic concentrator targets

We report an increase in MeV energy bremsstrahlung x-ray production using compound parabolic concentrators (CPC) compared to flat solid targets during relativistic laser-plasma experiments on a 140 J, 150 fs laser system using an f/40 focusing optic. CPC enhanced targets show a > 3x increase in high energy x-ray production over planar foil targets. Furthermore, this enhancement in x-ray energy spectra shows a direct improvement in the radiography of an image quality indicator (IQI) object with a 20 g/cm 2 areal density.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A dual high-energy radiography platform with 15 μ m resolution at the National Ignition Facility

To study matter at extreme densities and pressures, we need mega laser facilities such as the National Ignition Facility as well as creative methods to make observations during timescales of a billionth of a second. To facilitate this, we developed a platform and diagnostic to characterize a new point-projection radiography configuration using two micro-wires irradiated by a short pulse laser system that provides a large field of view with up to 3.6 ns separation between images. In this work, we used tungsten-carbide solid spheres as reference objects and inferred characteristics of the back-lighter source using a forward-fitting algorithm. The resolution of the system is inferred to be 15 μm (using 12.5 μm diameter wires). The bremsstrahlung temperature of the source is 70–300 keV, depending on laser energy and coupling efficiency. By adding the images recorded on multiple stacked image plates, the signal-to-noise of the system is nearly doubled. The imaging characterization technique described here can be adapted to most point-projection platforms where the resolution, spectral contrast, and signal-to-noise are important.

47 OTHER INSTRUMENTATION↗

Simultaneous compression and opacity data from time-series radiography with a Lagrangian marker

Time-resolved radiography can be used to obtain absolute shock Hugoniot states by simultaneously measuring at least two mechanical parameters of the shock, and this technique is particularly suitable for one-dimensional converging shocks where a single experiment probes a range of pressures as the converging shock strengthens. However, at sufficiently high pressures, the shocked material becomes hot enough that the x-ray opacity falls significantly. Additionally, if the system includes a Lagrangian marker such that the mass within the marker is known, this additional information can be used to constrain the opacity as well as the Hugoniot state. In the limit that the opacity changes only on shock heating, and not significantly on subsequent isentropic compression, the opacity of the shocked material can be determined uniquely. More generally, it is necessary to assume the form of the variation of opacity with isentropic compression or to introduce multiple marker layers. Alternatively, assuming either the equation of state or the opacity, the presence of a marker layer in such experiments enables the non-assumed property to be deduced more accurately than from the radiographic density reconstruction alone. An example analysis is shown for measurements of a converging shock wave in polystyrene at the National Ignition Facility.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗