Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “quality”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Effects of Magnetic and Electric Field Uniformity on Coded Aperture Imaging Quality in a Cycloidal Mass Analyzer

Cycloidal mass analyzers are unique sector mass analyzers as they exhibit perfect double focusing, making them ideal for incorporating spatial aperture coding, which can increase the throughput of a mass analyzer without affecting the resolving power. However, the focusing properties of the cycloidal mass analyzer depend on the uniformity of the electric and magnetic fields. In this paper, finite element simulation and charged particle tracing were used to investigate the effect of field uniformity on imaging performance of a cycloidal mass analyzer. For the magnetic field, we evaluate a new permanent magnet geometry by comparing it to a traditional geometry. Results indicate that creating an aperture image in a cycloidal mass spectrometer with the same FWHM as the slit requires less than 1% variation in magnetic field strength along the ion trajectories. The new magnet design, called the opposed dipole magnet, has less than 1% field variation over an area approximately 62 × 65 mm; nearly twice the area available in a traditional design of similar size and weight. This allows ion imaging across larger detector arrays without loss of resolving power. In addition, we compare the aperture imaging quality of a traditionally used cycloidal mass spectrometer electric design with a new optimized design with improved field uniformity. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ATLAS data quality operations and performance for 2015–2018 data-taking

The ATLAS detector at the Large Hadron Collider reads out particle collision data from over 100 million electronic channels at a rate of approximately $100$ kHz, with a recording rate for physics events of approximately 1 kHz. Before being certified for physics analysis at computer centres worldwide, the data must be scrutinised to ensure they are clean from any hardware or software related issues that may compromise their integrity. Prompt identification of these issues permits fast action to investigate, correct and potentially prevent future such problems that could render the data unusable. This is achieved through the monitoring of detector-level quantities and reconstructed collision event characteristics at key stages of the data processing chain. This paper presents the monitoring and assessment procedures in place at ATLAS during 2015-2018 data-taking. Through the continuous improvement of operational procedures, ATLAS achieved a high data quality efficiency, with 95.6% of the recorded proton-proton collision data collected at $\sqrt{s}=13$ TeV certified for physics analysis.

43 PARTICLE ACCELERATORS↗

Getting Beyond Widgets: Performance of Efficient Indoor Air Quality System Retrofit Packages for Schools A report on the modeled energy, greenhouse gas, and cost savings of several multi-measure retrofit packages for energy efficiency and indoor air quality in primary schools

School facilities are often underfunded with aging and poorly maintained HVAC and lighting systems. Most existing school buildings stand to benefit significantly from retrofits in terms of energy, cost, and emissions savings. Ventilation and indoor air quality (IAQ), which are important aspects of a healthy and productive learning environment, can also be enhanced by some energy efficiency measures (EEMs). Packaging energy efficiency and IAQ systems retrofits may represent a golden opportunity to improve performance in this critical building sector.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

White-collar productivity and quality issues; Proceedings of the Symposium on Productivity and Quality: Strategies for Improving Operations in Government and Industry, Washington, DC, September 25, 26, 1984

Techniques for improving the productivity of white-collar workers while maintaining high product quality are examined in reviews and reports. The emphasis is on the application of strategies developed in the private sector to government-agency and aerospace-industry operations. Topics discussed include international competition, organizational attitudes and orientation, management practices, education and training, renewing large organizations, encouraging innovation, national initiatives, employee involvement, management involvement, and applications of new technology.

Gerard, M.↗

Gulf of Mexico Air Quality: CALIPSO Support for Gulf of Mexico Air Quality Relating to the Deepwater Horizon Oil Spill

On April 20, 2010, an oil platform belonging to BP exploded and leaked a huge volume of oil into the Gulf of Mexico. In an effort to control the spread of the oil, BP applied dispersants such as Corexit and conducted in-situ burnings of the oil. This catastrophe created a complex chain of events that affected not only the fragile water and land ecosystems, but the humans who breathe the air every day. Thousands of people were exposed to fumes associated with oil vapors from the spill, burning of the oil, and the toxic mixture of dispersants. While aiding in clean-up efforts, local fishermen were directly exposure to fumes when working on the Gulf. A notable amount of Gulf Coast residents were also exposed to the oil fumes as seasonal southeasterly winds blew vapors toward land. The Volatile Organic Compounds (VOC) found in oil vapors include: benzene, toluene, ethyl benzene, xylene, naphthalene, hydrogen sulfide and particulate matter (PM). Increases in water temperature and sunlight due to the summer season allow for these VOCs and PM to evaporate into the air more rapidly. Aside from the VOCs found in oil vapors, the dispersant being used to break up the oil is highly toxic and is thought to be even more toxic than the oil itself (EPA website, 2010). To protect human health, the environment, and to make informed policy decisions relevant to the spill, the EPA Region 6 has continuously monitored the affected areas carefully for levels of pollutants in the outdoor air that are associated with petroleum products and the burning of oil along the coast. In an effort to prevent, prepare for, and respond to future oil spills that occur in and around inland waters of the United States, the EPA has been working with local, state, and federal response partners. Air quality measurements were collected by the EPA at five active monitoring systems stationed along the coast.

Nguyen, Myngoc T.↗

Operational Use of the Air Quality Monitor on ISS and Potential for Air Quality Monitoring Onboard Submarines

The air quality monitor (AQM) began operations on the International Space Station (ISS) in March 2013 and was validated for operational use in January 2014. The AQM is a gas chromatograph-differential mobility spectrometer that currently monitors 22 target compounds in the ISS atmosphere. Data are collected twice per week, although data collection can be more frequent in contingency situations. In its second year, the AQM has provided data to decision-makers on several ISS contaminant related issues in both air and water. AQM has been used in strictly air incidents, such as a potential ammonia leak, and to investigate air contaminants affecting the water processing (excess ethanol). In the latter case data from water monitors and AQM were compared to understand the issue with the water processor. Additionally, the AQM has been moved to different ISS modules to determine whether air is sufficiently mixed between modules so that a central LAB module location is representative of the entire ISS atmosphere. Historic data on the ISS atmosphere in different modules from archival samples (ground lab analysis) suggest that the atmosphere is usually homogenous. This presentation will briefly describe the technical aspects of the AQM operations and summarize the validation results. The main focus of the presentation will be to discuss the results from the AQM survey of the ISS modules and to show how the AQM data has contributed to an understanding of environmental issues that have arisen on ISS. Presentation of a potential ammonia leak (indicated by an alarm) in 2015 will illustrate the use and value of the AQM in such situations.

Limero, Thomas↗

San Joaquin Valley Health & Air Quality II: Assessing Urban Heat Island Distribution and its Intersections with Air Quality to Understand Converging Vulnerabilities

The city of Stockton, California, located within the San Joaquin Valley (SJV), is a major hub for agricultural production and has endured the continuous threat to community health from nitrogen dioxide (NO 2 ) and increasing temperatures. The convergence of these issues occurs within historically segregated communities that are disproportionately facing health risks related to heat and air quality. Little Manila Rising (LMR), a social and environmental justice (EJ) advocacy non-profit, partnered with NASA DEVELOP for a second term project to evaluate county wide urban heat islands, sociodemographic vulnerability, landcover classification, and the convergence of these variables. We utilized Landsat 8 Thermal Infrared Sensor (TIRS) and Operational Land Imager (OLI) data to produce a land surface temperature (LST) and Normalized Difference Vegetation Index map. They added Centers for Disease Control (CDC) socioeconomic data from 2020 to identify which communities in Stockton were more susceptible to these environmental factors. Additionally, we used NAIP imagery to create a landcover map differentiating developed infrastructure from tree canopy cover. We discovered that south Stockton, where LMR resides, had the worst convergence of heat, air pollution, low canopy coverage and sociodemographic vulnerability compared to northern and rural parts of the city. This was further substantiated by statistical analysis showing a strong positive relationship between areas of high LST and low vegetation. The results provided LMR with compelling evidence to use in their EJ advocacy, and in their efforts to inform state officials of the discriminatory issues they face.

Urban Heat Islands↗

Hydrogen fuel quality analyzer with self-humidifying electrochemical cell and methods of testing fuel quality

A fuel quality analyzer for detecting contaminants in a fuel supply includes an anode flow field plate defining a first fuel flow field channel and a fuel inlet port, a cathode flow field plate defining a second fuel flow field channel and a fuel outlet port, a polymer electrolyte membrane between the anode and cathode flow field plates, a first electrode between the anode flow field plate and the polymer electrolyte membrane, and a second electrode between the cathode flow field plate and the polymer electrolyte membrane. The second electrode has a higher platinum loading than the first electrode. A reservoir volume is defined by the anode and cathode flow field plates. At least a portion of the polymer electrolyte membrane extends into the reservoir volume. The reservoir volume is configured to retain water to humidify the polymer electrolyte membrane.

08 HYDROGEN↗