Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pumps”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Experimental study of R452B and R454B as drop-in replacement for R410A in split heat pumps having tube-fin and microchannel heat exchangers

The objective of this study is to experimentally evaluate two residential split heat pumps using low-GWP refrigerants, i.e., R452B and R454B, and compare the results against R410A. In this work, each heat pump used the same model of two-speed scroll compressor, the same indoor blower and outdoor fan. However, they were distinguished by the indoor and outdoor heat exchanger types: tube-fin heat exchangers (TFHXs) in one case, and microchannel heat exchangers (MCHXs) in the other. The two heat pumps were extensively evaluated following the test conditions for two-speed SEER (cooling seasonal energy efficiency rating)/HSPF (heating seasonal performance factor) ratings.In general, these results show that R452B and R454B are good replacement candidates for R410A for heat pump using tube-fin heat exchangers and microchannel heat exchangers. R452B and R454B led to lower capacities. In the TFHX heat pump, on average, compared to the performance of R410A, the cooling capacity of R452B is 96%; the heating capacity of R452B is 91%; the cooling capacity of R454B is 95%, the heat capacity of R454B is 89%. In the MCHX heat pump, the cooling capacity of R452B is 97%; the heating capacity of R452B is 97%; the cooling capacity of R454B is 98%, the heat capacity of R454B is 97%. With respect to cooling and heating seasonal performances, in the TFHX heat pump, the SEERs of R452B and R454B are 1.5% lower than R410A. HSPFs of the three refrigerants are identical. In the MCHX heat pump, R454B has 7% higher SEER, and R452B has 2% higher SEER than R410A; in heating mode, R454B has the same HSPF as R410A, while R452B is 4% more efficient. The compressor lubricant overheating issue of R452B and R454B, at low ambient heating condition, high stage, should be noticed.

42 ENGINEERING↗

Advances in supervisory control strategies for a heat pump centric HVAC system − a comprehensive review on applications

There is an increase in research investigating the development and deployment of supervisory controllers that enable high efficiency electrically driven vapor compression heat pumps operating within grid interactive efficient buildings to provide demand side management. This paper reviews over sixty relevant case studies within this domain that focus on commercial off-the-shelf heat pumps whose primary task is providing space conditioning. The concept of a heat pump-centric heating, ventilation, and air-conditioning system is introduced, accompanied by a detailed overview of various kinds of electric heat pumps and building-level thermal energy storage configurations. Additionally, the different types of supervisory controller designs, including rule-based control and model predictive control, are discussed, along with the various methods for communication between a supervisory controller and a downstream heat pump’s local controller. A comparative analysis is conducted in order to categorize the reviewed case studies based on their system design, supervisory control algorithm, and validation methodology. This detailed analysis allows the review to establish current research trends, identify potential gaps, and suggest future directions for the development of this technology. Overall, the authors recommend that more future research be devoted to low-cost practical retrofits that allow for easy integration of active thermal energy storage within heat pump-centric heating, ventilation, and air-conditioning system systems that utilize direct expansion heat pumps. We also suggest more research into the development and deployment of supervisory controllers that can properly communicate with commercial off-the-shelf heat pump local controller available control inputs, e.g., zone temperature setpoint. Lastly, more rigorous experimental demonstrations of advanced supervisory control within real and or closed-loop, transient/ quasi-steady state environments are necessary to reduce industry wide skepticism of this technology.

Demand side management↗

Validation of density pump-out by pedestal-foot magnetic island formation prior to ELM suppression in KSTAR and DIII-D tokamaks

Abstract TM1 nonlinear two-fluid simulations reveal key characteristics of density pump-out caused by pedestal-foot island formation when applying resonant magnetic perturbation (RMP). These characteristics include a bifurcation in pump-out with a low RMP coil current threshold, a sensitivity of pump-out magnitude to q 95 , and the magnitude of pump-out scaling as the square root of the RMP coil current. Dedicated experiments are carried out in the KSTAR and DIII-D tokamaks to validate these features and show that: (1) a staircase bifurcation in density pump-out is observed when slowly ramping up the n = 1 RMP current, and the density fluctuations are found to be slightly decreased from the pedestal-foot to the pedestal-top; (2) the magnitude of density pump-out becomes weaker when decreasing q 95 from 5.5 to 4.9, and a partial recovery of density pump-out is observed when q 95 is ramped down to lower than 4.9; and (3) analysis of a DIII-D database of n = 3 RMP edge-localized mode control experiments finds that the magnitude of density pump-out is proportional to the square root of RMP coil current Δ n e / n e ∝ I RMP 0.5 . These experimental observations are consistent with TM1 simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Size Up or Size Down? National Analysis of Heat Pump Sizing and Impacts

Electrification of on-site fossil fuel combustion in buildings is recognized as a key component of achieving global greenhouse gas emissions targets. Air-source heat pumps are an efficient approach for space heating electrification. However, a major barrier to heat pump adoption is the high installation cost relative to furnaces and air conditioners. Because the installation cost of heat pumps - especially cold climate models - is dependent on their size, it is important to understand the distribution of heat pump sizes using different sizing methods and factors that impact heat pump sizing. In this study, we use sub-hourly physics simulations of 550,000 statistically representative dwelling units to analyze the distribution of heat pump size in the U.S. for three different efficiency levels of heat pumps, with and without building insulation and air sealing upgrades. We will present results from the national analysis of different factors affecting heat pump sizing along with the impact of sizing decisions on upgrade costs and operating costs.

electrification↗

Volumetric efficiency and pressure pulsations of a triplex reciprocating supercritical CO 2 pump

A reciprocating triplex pump has been integrated into a closed-loop supercritical carbon dioxide test facility. The pump is designed to compress liquid or supercritical carbon dioxide and has a maximum volumetric flow rate of 51 L/min. A sweep across the pump’s speed range of 100–1000 rev/min was performed with inlet conditions between 60 and 160 bar. The volumetric efficiency was found to increase as pump speed increased from 10 to 40 % before it plateaued at higher pump speeds. The mechanical efficiency increased linearly with pump speed and was not affected by system pressure. Pressure pulsations caused by the plungers and valves were also measured at each speed. Additionally, a 35-liter buffer volume, connected near the pump’s discharge was isolated at each speed to determine its effectiveness as a pulsation dampener. Overall the reciprocating pump was shown to perform exceptionally with liquid or supercritical inlet conditions applicable to many supercritical fluid applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluating Transfer and Pumping of Slurries from Pulsed Jet Mixed Vessels

Due to gravity, solids in slurries will settle if density differences between the solids and liquid are positive (i.e., particle has a negative buoyant force) unless rheological properties and flow conditions are adequate to overcome the gravitational effects. The rate of settling depends on the force balance of the particle, which includes the surface forces associated with fluid rheology. Given the same fluid and solid properties, particles that are larger and denser tend to settle faster. When pumping slurry into a vessel at concentrations precluding hindered settling with insufficient mixing, particle and density distributions can result in preferential settling, creating stratification in the solids concentration within the vessel. For vessels with transfer line inlets located in the lower portion of the tank, the stratified solids concentration may be detrimental to the transfer system performance. Elevated concentrations of solids in the slurry entrained at the inlet to the transfer line can result in the effective viscosity or slurry bulk density exceeding the design limits of the pump. These conditions could result in plugging of the transfer line or onset of cavitation of the pumps because of excessive pressure drop. These conditions can be exacerbated with periodic inlet conditions existing at the transfer line inlet. Periodic conditions can result when vessel mixing is intermittent such as with pulsed jet mixers (PJM). The transfer line inlet conditions are impacted by the periodic nature of the PJM operations with respect to suspension of solids and their transport to the inlet of the transfer line. A scaling approach is presented, and corresponding test requirements are developed for assessing the prevention of plugging the pipeline. Line plugging mechanisms are addressed that do not include plugging due to steady-state high-density slurry entering the transfer line and reducing the net positive suction head available (NPSHA) at the pump inlet to below that required for pump operation. Items considered include the transition to reduced relative flow velocities, such that the critical pipe velocity for solids deposition, Ucd, is not maintained, and segregation of heavy solids during the transport. The recommended requirements to prevent plugging include: • Limits for viscosity and density for entrained slurry to prevent the pressure drop in the pipeline from exceeding pump capacity. • Limits for viscosity and density for entrained slurry to prevent the net positive suction head available (NPSHA) from falling below the net positive suction head required (NPSHR) for operating the pump. • Transfer line velocity and flow rate requirements to maintain solids in suspension, while avoiding line plugging that results from deposition of solids within the transfer line. This paper describes the development of the scaling and testing requirements to verify that proposed approaches for transfer and pump out are appropriately developed

periodic flow, mixing, pipeline plugging, scaling,↗

Cost-Optimized Cold Climate Heat Pump Development and Field Test

Cold climate heat pumps (CCHPs) expand the heat pump market to climates where heating demand is dominant. They can achieve more than 70% energy savings compared with electric resistance heating and operate at lower cost than using tank-stored propane to fuel a furnace. A high-efficiency heat pump with a heating seasonal performance factor (HSPF)—as defined by the Air-Conditioning, Heating, and Refrigeration Institute (AHRI 2008)—greater than 10.0 would be more efficient than gas heating in terms of source energy. However, developing a cost-effective CCHP involves some challenges. A typical single-speed, air-source heat pump (ASHP) with an HSPF of 7.7 Btu/Wh does not work well under cold outdoor temperature conditions typical of cold climate locations for four major reasons: 1. Discharge temperature is too high—The low suction pressure and high compression pressure ratio at low ambient temperatures causes high compressor discharge temperatures in excess of the maximum limit for many of the compressors on the market. Furthermore, system charge of a heat pump is usually optimized in the cooling mode, which leads to overcharge conditions in the heating mode, further increasing the discharge temperature. 2. Heating capacity is insufficient if sized to meet the building design cooling load— Heating capacity of a single-speed heat pump decreases with ambient temperature. The heating capacity at -13°F (-25°C) typically decreases to 20%–40% of the rated heating capacity at 47°F (8.3°C) (~equivalent to the rated cooling capacity at 95°F [35°C]). Therefore, a single-speed heat pump, typically sized to match the building design cooling load, cannot provide adequate heating capacity to match the building heating load at low ambient temperatures. The capacity deficit is filled by inefficient resistance heat, thus lowering the system efficiency and significantly increasing power demand. 3. Cyclic loss is significant if sized to meet the building design heating load—If a single-speed heat pump is sized to meet the heating load, it will be significantly oversized relative to the cooling load in many cold climates. This will cause excessive on/off cyclic loss during the cooling and heating operations at moderately low ambient temperatures. Thus, capacity modulation capability (e.g., using a variable-speed or multi-stage compressor) is necessary for a CCHP, which uses its full capacity to meet the peak heating load and partial capacity to meet the cooling and part-load heating loads. 4. Coefficient of performance (COP) is low—Heating COP degrades significantly at low ambient temperatures owing to the large temperature difference between the heat source and sink. A target CCHP should be sized to meet the building design heating load while minimizing the cyclic loss for the cooling and heating operations at moderate ambient temperatures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Perform Life Cycle Energy and GHG Emission Analysis, Select Candidate Refrigerant(s), Developing Heat Pump by Using Low-GWP Refrigerants and 5 mm Diameter Tubes

Reducing environmental impacts from the energy conversion systems has been an important research topic due to recent severe global climate changes. In residential buildings, the space heating and cooling are main energy consumers, which are relying on vapor compression based heat pumps. To mitigate the environmental impacts of residential systems, the heat pumps using low-GWP refrigerants and 5mm-tube heat exchangers are proposed to replace the conventional 9 mm or 7 mm tube heat exchangers. This research uses a simulation-based design method to optimize the refrigerant circuitries of a 5-ton low-GWP refrigerant heat pumps whose indoor and outdoor heat exchangers adopt 5 mm tubes. Heat pump systems using four commercially available low-GWP refrigerants (R454A, R454C, ARM20A and ARM20B) are optimized and compared with the baseline R410A system. The results indicate that directly replacing 9 mm tubes into 5mm tubes in the baseline systems induces heat pump performance degradation; by optimizing the 5 mm tube heat pumps with added tube rows, the system refrigerant charge is reduced up to 33% compared with the baseline; the optimized low-GWP 5 mm tube heat pumps offer the same or higher performance under both cooling and heating mode; that under cooling mode, the EER improvement is up to 10.7% and under heating mode the COP improvement is up to 3.4%; and a smart flow control device to maintain counter-flow circuitry pattern on both operating modes can improve the heating performance of 5 mm tube optimized system by up to 3.0%. In an effort to better understand the environmental impacts of these systems, life cycle climate performance (LCCP) evaluation method is used to assess the baseline and optimized systems. LCCP considers the direct and indirect emissions of the system over the course of its lifetime from manufacturing to disposal. Our analyses indicate that the optimized systems using 5mm tubes and low-GWP refrigerants can reduce life-cycle CO 2 emission significantly. And improving system efficiency is the most effective way to reduce the emission of low-GWP refrigerant systems. This report shows that using 5 mm diameter tubes in heat exchangers is a feasible approach to develop heat pumps with low-GWP refrigerants. Using the proposed design approach can yield higher system efficiency with lower environmental impact.

42 ENGINEERING↗

DOE Cold Climate Heat Pump Challenge: Development, Metrics, and Early Field Observations

Space heating in residential buildings is a major contributor of Greenhouse Gas (GHG) emissions in the United States. New, advanced electric heat pumps are poised to provide a low carbon alternative to traditional fossil-based heating, especially in colder climates. Widespread deployment of cold climate heat pumps could help address the significant portion of building emissions and primary energy used in American households, but these gains will require broader acceptance from consumers and decision makers. As part of the “Energy, Emissions, and Equity” (E3) initiative, the U.S. Department of Energy launched the Cold Climate Heat Pump Challenge (CCHP) in 2021 to accelerate the deployment of the next generation of air source heat pumps. The Challenge is currently focused on residential, centrally ducted, electric heat pumps, with a nominal cooling capacity greater than or equal to 24,000 Btu/h (2 tons) and less than or equal to 65,000 Btu/h (5 tons). The Challenge specifications represent a best-in-class heat pump product that provides high-efficiency heating performance in cold climates, employs environmentally friendly low-Global Warming Potential (GWP) refrigerants, and is designed to be grid interactive. Spearheaded by DOE in partnership with the US Environmental Protection Agency (EPA) and Natural Resources Canada (NRCan), the CCHP Challenge brings together numerous major heat pump manufacturers and key stakeholders including utilities and state agencies across the country. In addition to performance testing in a laboratory environment, a key component of this research is evaluating the in-field performance of the prototype heat pumps developed as part of the Challenge. This paper will discuss the development of the CCHP Challenge, key performance specifications, and the energy and non-energy metrics that will be evaluated through the field study. The types of data that are being collected from the units installed in homes across North America as part of the field validation will be described, including details about the sensors and data acquisition system. Data cleaning and analysis methodologies will be discussed, along with early observations from the winter 2022-2023, spring and summer performance periods, and an assessment of non-energy metrics through pre- and post-installation homeowner surveys. Challenges uncovered and lessons learned throughout the process will also be discussed. Finally, the paper will discuss next steps for the second winter assessment period, areas needing additional research, and potential applications of the data collected and analyzed through this work.

Mendon, Vrushali V.↗

Simulation of a PCM Integrated Heat Pump Using Time-of-Use Utility Structure based Control Strategy for Demand Response

To mitigate the variation in demand on the electric grid, thermal energy storage (TES) is an alternative to electric batteries and constructing new peaking power plants. The aggressive carbon reduction goals of the United States are accelerating the electrification of building equipment. If space heating and cooling in the US were electrified using conventional heat pump technologies, the winter electric grid peak would approximately double. Integrating TES with heat pump (HP) enables electrification of space cooling and heating devices without overtaxing the grid.This paper evaluates the benefits of a novel phase change material (PCM) integrated heat pump configuration via simulation. A one-dimensional PCM heat exchanger model which discretizes the PCM tank and refrigerant tubes into small control volumes is developed. Each control volume can have different PCM temperatures, PCM properties, and heat transfer coefficients. The PCM tank is charged by a wrapped tank condenser and discharged by an internal refrigerant coil. The PCM heat exchanger model is integrated into DOE/ORNL Heat Pump Design Model for heat pump system simulation.To demonstrate the performance of the PCM integrated heat pump, a case study in Chicago was performed. A Time-of-Use utility structure-based control strategy is implemented to schedule the PCM tank charging and discharging mode switching. Compared with a conventional electric heat pump, the PCM integrated heat pump shows superior performance on load shifting and utility cost reduction. As a result, the proposed system demonstrates 24.6% utility saving for cooling application and 25.8% utility saving for heating application.

Li, Zhenning↗

Field Demonstration and Adoption Impacts of an Affordable Thermoelectric Heat Pump

This study presents the design, field validation, and utility impacts of an air source heat pump that uses thermoelectric (TE) technology to provide supplemental heating at outside air temperatures below 17°F. Conventional heat pumps experience reduced heating capacity and COP at low outdoor temperatures due to the temperature difference between the source and demand sides of the vapor compression cycle. Consequently, during colder months, supplemental heating such as electric resistance or natural gas furnace is often needed to provide additional warmth, which increases the overall equipment and energy costs. To address this challenge, a TE subcooler (an array of solid-state, thermoelectric modules that provides heat pumping using non-vapor compression technique) is fabricated and integrated with the vapor compression cycle of a conventional air-source heat pump. In colder ambient conditions, TE subcooler exchanges heat with the refrigerant to provide additional subcooling, thereby enhancing the capacity of the heat pump. The operation of thermoelectric-integrated heat pump was demonstrated in an occupied single-family home in Nashville, TN. The TE subcooler increased the system’s heating capacity at 15°F outdoor temperature by 25–30% and reduced electricity demand by 10%. It also met the heating load in the house without supplemental electric resistance down to 5°F outdoors, delivering the additional heat at nearly 80% greater efficiency compared to electric resistance heating. With a modest first cost increment of 10–15% over conventional single-speed heat pumps, this approach offers a promising, energy-efficient solution to accelerate residential heat pump adoption in the U.S.

KRISHNAMOORTHY, Sreenidhi [Electric Power Research↗

Numerical study of the effect of propped surface area and fracture conductivity on shale gas production: Application for multi-size proppant pumping schedule design

Hydraulic fracturing is a technique extensively used in the oil and gas industry, where water, proppant (sand) and additives are injected into unconventional reservoirs to enhance the recovery of shale hydrocarbon. Although some previous studies have developed pumping schedules that maximize gas production for a single-size proppant, there are very few studies that consider the effect of varying proppant diameters across pumping stages on shale gas production. Motivated by this, we carried out an extensive sensitivity analysis to determine the effect of different proppant diameters on the average fracture conductivity (FC), average propped surface area (PSA) and cumulative shale gas production volume. We found out that the cumulative shale gas production volume depends on both the average PSA and average FC. We also found out that small-diameter proppant resulted in higher average PSA and lower average FC, whereas large-diameter proppant resulted in lower average PSA and higher average FC. Hence, we designed a multi-size proppant pumping schedule considering both of these parameters into account for simultaneously propagating multiple fractures to maximize shale gas production from unconventional reservoirs. Since the size of injected proppant particles determines the average PSA and average FC for the propped hydraulic fractures, we developed a novel framework called Sequentially Interlinked Modeling Structure (SIMS) to predict the average PSA, average FC and cumulative shale gas production volume at the end of 10 years for a given pumping schedule. Then, we used this SIMS framework to obtain a multi-size proppant pumping schedule that maximizes shale gas production. In closing, we demonstrated that the obtained pumping schedule gives a cumulative shale gas production volume greater than the values obtained from the existing pumping schedules.

03 NATURAL GAS↗

Development of High Temperature (>700°C) molten Salt Pump Technology for Gen3 Solar Power Tower Systems

Generation 3 Concentrating Solar Power (CSP) Systems require thermal energy storage that can efficiently receive solar heat and deliver it to a working fluid at temperatures greater than 700°C. For liquid systems, the thermal transfer fluid must be phase stable over large temperature ranges. High temperature molten salts meet this criteria, but are difficult liquids to handle. The high heat and salt content can be very corrosive to several different materials that are wetted by the liquid salt. For power tower collectors, the molten salt must be pumped under high pressure to the top of the collector tower. These pumps have impellers and shafts as part of their rotating elements, and under load, require bearings to control shaft movement while rotating. These high temperature pumps require submerged bearings, and thus bearing materials that can withstand the temperature and molten salt contact over long periods of time. This is essential for keeping pump maintenance costs low, and downtime to a minimum. Long running bearing materials is an enabling technology for integrated liquid systems in Generation 3 CSP Systems. Keeping costs low and systems reliable are critical for the broad adoption of Gen 3 CSP Systems. Hayward Tyler, Inc (HTI) proposed development of journal bearing materials for use in vertical pumps designed for pumping high temperature molten salt on both the hot and cold sides of the solar power tower. To complete this objective, HTI utilized the testing capabilities of Oak Ridge National Laboratory (ORNL) and High Temperature System Design (HTSD). Materials would first be selected for static corrosion testing, then downselected for tribological testing. Successful tribologically tested materials would then be downselected for use in additional test regimes. Ten samples were selected for static corrosion testing. Three passed the static testing regime. Two of these materials were downselected for ball material in tribological testing against three metallic alloys: Sintered Y2O3 Partially Stabilized Zirconia YTZP and Silicon Nitride, Grade 147-31N. HTI also proposed collecting data from a thorough bearing test regime using a test rig designed and built as part of this project, and also a conceptual design for a high temperature molten salt vertical pump. HTI withdrew from the project prior to completion of this work and this report reflects only the work completed prior to withdrawal. The completed work produced two papers, one manuscript submitted for publication, and one paper published in the journal Solar Energy Materials and Solar Cells. The papers are: “Tribological behavior of ceramic-alloy bearing contacts in molten salt lubrication for concentrating solar power” and “Material Selection and Corrosion Studies Of Candidate Bearing Materials For Use In Molten Chloride Salt."

14 SOLAR ENERGY↗

Cold Climate Field Study of the Effect of Defrost Controls on the Integrated Performance of a Ductless Air-Source Heat Pump

Residential heat pumps have advanced over the past decade to allow for operation at colder temperatures. However, the challenges of frost accumulation and defrosting the outdoor coil remain. The goal of this study was to evaluate the impact of the control algorithms that determine when a heat pump needs to defrost and when the base pan heater runs on the overall heating efficiency of the heat pump. In this study, which occurred during the 2023–2024 heating season, we measured the performance of a ductless air-source heat pump installed in Fairbanks, Alaska, USA. The heat pump was instrumented to measure the electrical input and the thermal output, as well as selected internal variables and indoor and outdoor environmental conditions. The heat pump was first operated with factory default control algorithms associated with the initiation of defrost and control of the base pan heater. These factory default algorithms focused on aggressively defrosting the outdoor coil and keeping the base pan ice-free. In the middle of the winter, these algorithms were changed to focus on reducing defrost cycles and increasing efficiency, while the heat pump continued to be operated and monitored. The results showed that significant increases in efficiency are possible by improving the defrost and base pan heater control algorithms.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

BENEFIT with Northeastern University: HVAC Hardware-in-the-Loop Experimental Testing of a Heat Pump and Air Conditioner

This dataset includes HVAC Hardware-in-the-Loop (HIL) experimental results for a single stage, SEER 16, HSPF 9.5, 3-ton single-speed air source heat pump with 15 kW of backup auxiliary heating tested in both cooling and heating mode, and a two stage, SEER 21, 2-ton central air conditioner tested in cooling mode for a set of outdoor temperatures and indoor setpoint temperatures. In addition to these tests, experimental tests focused on the operation of auxiliary heating for the heat pump for winter condition were also conducted. The laboratory experiments for transient testing of the heat pump and air conditioner were conducted using the two HIL systems in the Systems Performance Laboratory (SPL) at NREL’s Energy Systems Integration Facility (ESIF). Further information on laboratory design and capabilities of the SPL along with the architecture of HVAC HIL system can be found in: Sparn, B. F. 2018. Laboratory Resources and Techniques to Evaluate Smart Home Technology (No. NREL/CP-5500-71696). National Renewable Energy Laboratory (NREL), Golden, CO (United States). https://www.nrel.gov/docs/fy18osti/71696.pdf and the experimental setup and validation of HVAC HIL platform can be found in: Ramaraj, S. and Sparn, B. 2022. Validation of HVAC Hardware-In-the-Loop Simulation for Advanced Control Strategies in Smart Homes (No. NREL/CP-5500-82562). National Renewable Energy Lab (NREL), Golden, CO (United States). https://www.nrel.gov/docs/fy22osti/82562.pdf. These experimental results can be used to validate how we currently model the cycling behavior of heat pumps and air conditioners. Additionally, many demand response programs implement heat pump and air conditioner control by changing the thermostat set point – these data may also be used to verify our models for heat pump and air conditioner demand response control are implemented correctly. The Test_Matrix file describes all the indoor and outdoor test conditions for heat pump and air conditioner and the file names of data sets include information about the test conditions. A wide range of outdoor air temperatures were chosen to accommodate summer and winter conditions. In addition to operating the HVAC equipment with different outdoor temperatures, we also operate the system with different indoor temperature set points to represent different grid signals or different operating conditions. For cooling conditions, the baseline set point is 72°F. To represent Load Up signals, the setpoint is changed to 68°F. The Load Shed set point is 76°F. For heating conditions, the baseline set point was assumed to be 68°F. The Load add set point is 72°F and the Load shed set point is 64°F. The starting indoor temperature for cooling conditions was set ~2°F above the indoor setpoint temperature so that the equipment turned on quickly. Similarly, the initial indoor temperature was set ~2°F lower than setpoint for heating mode tests to ensure that heating began quickly. The return air temperature was assumed to be equal to the indoor setpoint temperature in all cases. The experimental data are sampled at 1-second intervals. The data from ecobee thermostat at 5-minute interval are resampled and added to the corresponding file. The content of each data set is as follows: • T_Return (C): Measured return air temperature [C] • T_Return_SP (C): Return air temperature setpoint from E+ model, sent to HIL [C] • T_Supply (C): Measured supply air temperature at evaporator outlet [C] • T_Outdoor (C): Measured outdoor air temperature [C] • T_Outdoor_SP (C): Outdoor air temperature setpoint from weather file, sent to HIL [C] • T_Indoor (C): Measured indoor air temperature [C] • T_Indoor_SP (C): Indoor air temperature setpoint from E+ model, sent to HIL [C] • Outdoor Unit Power (W): Measured power of the outdoor unit [W] • Indoor Unit Power (W): Measured power of the indoor unit [W] • Evaporator Airflow Rate (CFM): Measured evaporator or indoor unit airflow rate sent to E+ model [CFM] • Cooling/Heating Capacity (kW): Calculated cooling/heating capacity sent to E+ model [kW] • T_SP_Thermostat (C): Thermostat cooling/heating setpoint temperature [C] • T_Indoor_Thermostat (C): Thermostat indoor air temperature [C]

24 POWER TRANSMISSION AND DISTRIBUTION↗

Virtual refrigerant charge sensing algorithm for residential CO₂ heat pumps

Natural refrigerants are increasingly adopted in next-generation heat pump systems, among which CO₂ heat pumps have attracted significant attention. However, due to their high operating pressures, the leakage risk is higher, resulting in undercharge conditions and degraded heat pump performance. Thus, developing an accurate refrigerant charge level detection technique is necessary to guarantee safe and efficient operation. Although virtual refrigerant charge (VRC) level calculation algorithms for CO₂ heat pumps exist, they typically rely on empirically selected features without a systematic selection framework, leading to multicollinearity and potential overfitting, which limit their prediction accuracy and generalizability. To address these issues, this study proposes a VRC algorithm framework with a systematic feature selection method that identifies physically meaningful and statistically significant features, and is applied using a residential CO₂ heat pump as a case study. The method is extended from previous work on conventional refrigerants to account for charge behavior in CO₂ gas coolers. The selected features include gas cooler outlet density, evaporator pressure, and superheat temperature. The results demonstrate that the proposed feature selection method significantly improves prediction accuracy compared to existing VRC approaches. A relatively small training dataset (∼30 samples) is sufficient for feature identification and model development. The developed algorithm achieves less than 3% prediction error under both undercharge and overcharge conditions, representing reductions of 46.7% and 35.3% compared to two recent reference VRC algorithms for transcritical CO₂ heat pumps reported in the literature. The proposed algorithm and feature selection method enhance leakage detection capability, facilitate the deployment of CO₂ heat pump systems, and contribute to reduced energy waste and maintenance costs.

Guo, Fangzhou [Lawrence Berkeley National Laborato↗

Stirring and peristaltic pumping alter flow electrode particle size and morphology

Flowable carbon-based electrodes are widely studied in electrochemical systems for energy storage and water treatment. Most laboratory- and pilot-scale studies employ active mixing for slurry preparation and handling and use peristaltic pumps for slurry circulation. Magnetic stirring is the most prevalent mixing method at the laboratory scale, and the combination of magnetic mixing and peristaltic pumping is favored for convenience and compatibility with particulate suspensions. However, these methods can strongly affect particle size and morphology (and therefore cell performance). In this study, we evaluate how mixing and pumping influence particle degradation in two commonly used carbon materials: spherical carbon black (CB) beads and powdered activated carbon (AC). We performed 24 h stirring-only experiments using magnetic, orbital, and overhead stirring. Separately, we conducted 32 h circulation experiments using a commercial peristaltic pump. Particle morphology and size were analyzed using optical microscopy and laser diffraction. The initially spherical CB beads (~580 μm, 1.5 wt%) exhibit rapid and extensive breakdown under both peristaltic pumping and magnetic stirring. By comparison, AC particles (initially ~31 μm) tested at 1.5 and 15 wt% showed measurable size reductions of up to ~25 % under either stirring or pumping. In conclusion, these findings highlight the need to account for and quantify morphological changes caused by both stirring and pumping in the design and associated evaluation of flowable electrode systems.

Chemistry↗

Influence of pump laser fluence on ultrafast myoglobin structural dynamics

High-intensity femtosecond pulses from an X-ray free-electron laser enable pump–probe experiments for the investigation of electronic and nuclear changes during light-induced reactions. On timescales ranging from femtoseconds to milliseconds and for a variety of biological systems, time-resolved serial femtosecond crystallography (TR-SFX) has provided detailed structural data for light-induced isomerization, breakage or formation of chemical bonds and electron transfer. However, all ultrafast TR-SFX studies to date have employed such high pump laser energies that nominally several photons were absorbed per chromophore. As multiphoton absorption may force the protein response into non-physiological pathways, it is of great concern whether this experimental approach allows valid conclusions to be drawn vis-à-vis biologically relevant single-photon-induced reactions. Here we describe ultrafast pump–probe SFX experiments on the photodissociation of carboxymyoglobin, showing that different pump laser fluences yield markedly different results. In particular, the dynamics of structural changes and observed indicators of the mechanistically important coherent oscillations of the Fe–CO bond distance (predicted by recent quantum wavepacket dynamics) are seen to depend strongly on pump laser energy, in line with quantum chemical analysis. Our results confirm both the feasibility and necessity of performing ultrafast TR-SFX pump–probe experiments in the linear photoexcitation regime. We consider this to be a starting point for reassessing both the design and the interpretation of ultrafast TR-SFX pump–probe experiments such that mechanistically relevant insight emerges.

59 BASIC BIOLOGICAL SCIENCES↗