Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “probe counts”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Modelling galaxy cluster triaxiality in stacked cluster weak lensing analyses

Counts of galaxy clusters offer a high-precision probe of cosmology, but control of systematic errors will determine the accuracy of this measurement. Using Buzzard simulations, we quantify one such systematic, the triaxiality distribution of clusters identified with the redMaPPer optical cluster finding algorithm, which was used in the Dark Energy Survey Year-1 (DES Y1) cluster cosmology analysis. We test whether redMaPPer selection biases the clusters’ shape and orientation and find that it only biases orientation, preferentially selecting clusters with their major axes oriented along the line of sight. Modelling the richness–mass relation as log-linear, we find that the log-richness amplitude ln (A) is boosted from the lowest to highest orientation bin with a significance of 14σ, while the orientation dependence of the richness-mass slope and intrinsic scatter is minimal. We also find that the weak lensing shear-profile ratios of cluster-associated dark haloes in different orientation bins resemble a ‘bottleneck’ shape that can be quantified with a Cauchy function. We test the correlation of orientation with two other leading systematics in cluster cosmology – miscentering and projection – and find a null correlation. The resulting mass bias predicted from our templates confirms the DES Y1 finding that triaxiality is a leading source of bias in cluster cosmology. However, the richness-dependence of the bias confirms that triaxiality does not fully resolve the tension at low-richness between DES Y1 cluster cosmology and other probes. Our model can be used for quantifying the impact of triaxiality bias on cosmological constraints for upcoming weak lensing surveys of galaxy clusters.

79 ASTRONOMY AND ASTROPHYSICS↗

Nonlinearly realized extended supergravity

We provide a nonlinear realization of supergravity with an arbitrary number of supersymmetries by means of coset construction. The number of gravitino degrees of freedom counts the number of supersymmetries, which will possibly be probed in future experiments. We also consider Goldstino embedding in the construction to discuss the relation to nonlinear realizations with rigid supersymmetries.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Data-Acquisition System For Rotor Vibrations

New system trades hardware for software to reduce cost. Composite train of interspersed blade-detection pulses produced by gates at four probe ports on data-acquisition board. Pulses latch count from high-speed wraparound clock counter and initiate writing of count onto current address of memory. Result: time corresponding to each blade passage stamped into memory.

Posta, Stephen J.↗

Deep imaging of the field of the z = 4.9 quasar PC 1247+3406, and faint galaxy counts in the K band with the Keck telescope

We present deep images in the K(sub s) band of the field of the quasar PC 1247+3406 at z = 4.897, obtained using the near-infrared camera on the W. M. Keck telescope. A number of faint sources have been detected, some of which appear to be quite red. Their nature and redshifts remain uncertain at this time. These data are combined with deep Keck infrared images of five additional fields and present galaxy counts reaching down to K(sub s) = 22 mag, comparable to the deepest K-band surveys to date. The data presented here are in good agreement with the Hawaii Deep Survey and represent the first independent verification of those results. The slope of the log N-log S relation derived from these data agrees well with the Hawaii Deep Survey, while the counts are slightly higher, especially at the faintest levels probed here. This may be due to a presence of groups or clusters around the target objects at high redshifts.

Soifer, B. T.↗

The SRG/eROSITA All-Sky Survey: Dark Energy Survey year 3 weak gravitational lensing by eRASS1 selected galaxy clusters

Context. Number counts of galaxy clusters across redshift are a powerful cosmological probe if a precise and accurate reconstruction of the underlying mass distribution is performed – a challenge called mass calibration. With the advent of wide and deep photometric surveys, weak gravitational lensing (WL) by clusters has become the method of choice for this measurement. Aims. We measured and validated the WL signature in the shape of galaxies observed in the first three years of the Dark Energy Survey (DES Y3) caused by galaxy clusters and groups selected in the first all-sky survey performed by SRG (Spectrum Roentgen Gamma)/eROSITA (eRASS1). These data were then used to determine the scaling between the X-ray photon count rate of the clusters and their halo mass and redshift. Methods. We empirically determined the degree of cluster member contamination in our background source sample. The individual cluster shear profiles were then analyzed with a Bayesian population model that self-consistently accounts for the lens sample selection and contamination and includes marginalization over a host of instrumental and astrophysical systematics. To quantify the accuracy of the mass extraction of that model, we performed mass measurements on mock cluster catalogs with realistic synthetic shear profiles. This allowed us to establish that hydrodynamical modeling uncertainties at low lens redshifts (z < 0.6) are the dominant systematic limitation. At high lens redshift, the uncertainties of the sources’ photometric redshift calibration dominate. Results. With regard to the X-ray count rate to halo mass relation, we determined its amplitude, its mass trend, the redshift evolution of the mass trend, the deviation from self-similar redshift evolution, and the intrinsic scatter around this relation. Conclusions. The mass calibration analysis performed here sets the stage for a joint analysis with the number counts of eRASS1 clusters to constrain a host of cosmological parameters. We demonstrate that WL mass calibration of galaxy clusters can be performed successfully with source galaxies whose calibration was performed primarily for cosmic shear experiments, opening the way for the cluster cosmological exploitation of future optical and NIR surveys like Euclid and LSST.

79 ASTRONOMY AND ASTROPHYSICS↗

Combining cluster number counts and galaxy clustering

The abundance of clusters and the clustering of galaxies are two of the important cosmological probes for current and future large scale surveys of galaxies, such as the Dark Energy Survey. In order to combine them one has to account for the fact that they are not independent quantities, since they probe the same density field. It is important to develop a good understanding of their correlation in order to extract parameter constraints. We present a detailed modelling of the joint covariance matrix between cluster number counts and the galaxy angular power spectrum. We employ the framework of the halo model complemented by a Halo Occupation Distribution model (HOD). We demonstrate the importance of accounting for non-Gaussianity to produce accurate covariance predictions. Indeed, we show that the non-Gaussian covariance becomes dominant at small scales, low redshifts or high cluster masses. We discuss in particular the case of the super-sample covariance (SSC), including the effects of galaxy shot-noise, halo second order bias and non-local bias. We demonstrate that the SSC obeys mathematical inequalities and positivity. Using the joint covariance matrix and a Fisher matrix methodology, we examine the prospects of combining these two probes to constrain cosmological and HOD parameters. We find that the combination indeed results in noticeably better constraints, with improvements of order 20% on cosmological parameters compared to the best single probe, and even greater improvement on HOD parameters, with reduction of error bars by a factor 1.4-4.8. This happens in particular because the cross-covariance introduces a synergy between the probes on small scales. We conclude that accounting for non-Gaussian effects is required for the joint analysis of these observables in galaxy surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

Simplicity Beneath Complexity: Counting Molecular Electrons Reveals Transients and Kinetics of Photodissociation Reactions

Abstract Time‐resolved pump–probe gas‐phase X‐ray scattering signals, extrapolated to zero momentum transfer, provide a measure of the number of electrons in a system, an effect that arises from the coherent addition of elastic scattering from the electrons. This allows to identify reactive transients and determine the chemical reaction kinetics without the need for extensive scattering simulations or complicated inversion of scattering data. We examine the photodissociation reaction of trimethylamine and identify two reaction paths upon excitation to the 3p state at 200 nm: a fast dissociation path out of the 3p state to the dimethyl amine radical (16.6±1.2 %) and a slower dissociation via internal conversion to the 3s state (83.4±1.2 %). The time constants for the two reactions are 640±130 fs and 74±6 ps, respectively. Additionally, it is found that the transient dimethyl amine radical has a N−C bond length of 1.45±0.02 Å and a C−N−C bond angle of 118°±4°.

Ruddock, Jennifer M.↗

Simplicity Beneath Complexity: Counting Molecular Electrons Reveals Transients and Kinetics of Photodissociation Reactions

Time-resolved pump–probe gas-phase X-ray scattering signals, extrapolated to zero momentum transfer, give a measure of the number of electrons in a system, an effect that arises from the coherent addition of elastic scattering from the electrons. This allows to identify reactive transients and determine the chemical reaction kinetics without the need for extensive scattering simulations or complicated inversion of scattering data. We investigate the photodissociation reaction of trimethylamine and identify two reaction paths upon excitation to the 3p state at 200 nm: a fast dissociation path out of the 3p state to the dimethyl amine radical (16.6±1.2 %) and a slower dissociation via internal conversion to the 3s state (83.4±1.2 %). The time constants for the two reactions are 640±130 fs and 74±6 ps, respectively. Additionally, it is found that the transient dimethyl amine radical has a N-C bond length of 1.45±0.02 Å and a C-N-C bond angle of 118°±4°.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Calibration of a Neutron Hydroprobe for Moisture Measurements in Small-Diameter Steel-Cased Boreholes

Computation of soil moisture content from thermalized neutron counts for the T-Farm Interim cover requires a calibration relationship but none exists for 2-in tubes. A number of calibration options are available for the neutron probe, including vendor calibration, field calibration, but none of these methods were deemed appropriate for the configuration of interest. The objective of this work was to develop a calibration relation for converting neutron counts measured in 2-in access tubes to soil water content. The calibration method chosen for this study was a computational approach using the Monte Carlo N-Particle Transport Code (MCNP). Model calibration was performed using field measurements in the Hanford calibration models with 6-in access tubes, in air and in the probe shield. The bet-fit model relating known water content to measured neutron counts was an exponential model that was essentially equivalent to that currently being used for 6-in steel cased wells. The MCNP simulations successfully predicted the neutron count rate for the neutron shield and the three calibration models for which data were collected in the field. However, predictions for air were about 65% lower than the measured counts . This discrepancy can be attributed to uncertainties in the configuration used for the air measurements. MCNP-simulated counts for the physical models were essentially equal to the measured counts with values. Accurate prediction of the response in 6-in casings in the three calibration models was motivation to predict the response in 2-in access tubes. Simulations were performed for six of the seven calibration models as well as 4 virtual models with the entire set covering a moisture range of 0 to 40%. Predicted counts for the calibration models with 2-in access tubes were 40 to 50% higher than in the 6-inch tubes. Predicted counts for water were about 60% higher in the 2-in tube than in the 6-in tube. The discrepancy between the 2-in and 6-in tube can be attributed to the smaller air gap between the probe and the 2-in access tube. The best-fit model relating volumetric water content to count ratio (CR) is of the form e^A x CR^B with A=0.3596 ± 0.0216 and B=0.4629 ± 0.0629 and r^2= 0.9998. It is recommended that the calibration function based on the count ratio, rather than raw counts, be used to avoid the effects of electronic noise in the probe that may arise due to the conditions at the time of measurement. These results suggest that the MCNP code can be used to extend calibrations for the neutron probe to different conditions including access tube size as well as composition without the need to construct additional physical models.

36 MATERIALS SCIENCE↗

Photon-Counting Interferometry to Detect Geontropic Space-Time Fluctuations with GQuEST

The gravity from the quantum entanglement of space-time (GQuEST) experiment uses tabletop-scale Michelson laser interferometers to probe for fluctuations in space-time. We present a practicable interferometer design featuring a novel photon-counting readout method that provides unprecedented sensitivity, as it is not subject to the interferometric standard quantum limit. We evaluate the potential of this design to measure space-time fluctuations motivated by recent “geontropic” quantum gravity models. The accelerated accrual of Fisher information offered by the photon-counting readout enables GQuEST to detect the predicted quantum gravity phenomena within measurement times at least 100 times shorter than equivalent conventional interferometers. The GQuEST design, thus, enables a fast and sensitive search for signatures of quantum gravity in a laboratory-scale experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Identification and quantification of distinct active sites in Hf-Beta zeolites for transfer hydrogenation catalysis

Despite the significant progress made in characterizing different framework heteroatom sites that exist in Lewis acidic zeolites with probe molecule adsorption and spectroscopy, methods to reliably quantify site counts remain indefinite and have been primarily limited to Sn and Ti Lewis acid sites. Here, methods to quantify framework Lewis acidic Hf 4+ sites in zeolite Beta (Hf-Beta) with two Lewis base titrants (pyridine, deuterated acetonitrile) were developed using infrared (IR) spectroscopy. Lewis acid site counts for Hf-Beta zeolites were validated by measuring integrated molar extinction coefficients (IMECs; ε, cm μmol –1 ) on Sn-Beta zeolites using identical Lewis base titrants to benchmark site counts with established literature procedures to quantify Lewis acid sites in Beta zeolites from IR spectra. Highlighting the importance of benchmarking active site counts against well-established experimental protocols, IMECs of CD 3 CN bound to open (ε(Sn; 2316 cm –1 ): 1.80 ± 0.25) and closed (ε(Sn; 2308 cm –1 ): 3.76 ± 0.33) Sn sites were ~1.8x larger than those previously reported while total Lewis acid site counts agreed with those measured by pyridine (ε(Sn; 1451 cm –1 ): 1.58 ± 0.16) on six different Sn-Beta zeolites. IMECs measured for IR peaks reflecting pyridine bound to Lewis acidic Hf sites (ε(Hf; 1448 cm –1 ): 1.54 ± 0.21) and CD 3 CN bound to open (ε(Hf; 2313 cm –1 ): 2.40 ± 0.22) and closed (ε(Hf; 2307 cm –1 ): 3.55 ± 0.41) Hf sites, gave similar counts for the total number of Lewis acidic sites across six Hf-Beta zeolites (Si/Hf = 100–413). Consistent with previous reports with Sn-Beta catalysts where open Sn sites are responsible for catalytic turnover, apparent first and zero-order MPVO rate constants (0.01–1 M cyclohexanone in 2-butanol; per total Hf, 373 K) correlated with the total number of open Hf sites, per total Hf, but not with the total number of closed Hf sites or total Lewis acid site counts. Measured initial MPVO rates (0.1 M cyclohexanone in 2-butanol, per open Hf, 373 K) were ~25x higher on hydrophobic Hf-Beta-F than on hydrophilic Hf-Beta-OH zeolites. Overall, the apparent first-order MPVO rate constants (2-butanol solvent, per open Hf, 373 K) were ~6x higher on Hf-Beta-F than on Hf-Beta-OH zeolites. The characterization methods reported here enable normalization of MPVO turnover rates on Sn- and Hf-Beta zeolites by their number of open sites. Finally, this enables performing quantitative rate comparisons across Lewis acid zeolites of varying active site identity, solvation, and pore topology used in liquid-phase catalysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Poisson vs. Gaussian statistics for sparse X-ray data: Application to the soft X-ray spectrometer

Abstract Reliable results when fitting X-ray data require proper consideration of the statistics involved. We probe the impact of Gaussian versus Poisson statistics at low count levels using both the standard χ2 method and maximum likelihood based on Poisson (C) statistics. The difference is studied and quantified through simulated spectra with known properties. We then test the results through analysis of Mn Kα calibration data taken with the flight spare microcalorimeter for the Hitomi soft X-ray spectrometer. Through comparison with simulations, our results show that the χ2 method tends to give overly optimistic estimates of the detector energy resolution, in particular when there are few counts. Given an energy resolution of ∼5 eV and a line with about 100 photons, the line width becomes ∼10% lower in the χ2 method than in Poisson statistics. This is a consequence of the uncertainties being dominated by counting statistics, and therefore highlights the need to choose the appropriate fit statistic.

79 ASTRONOMY AND ASTROPHYSICS↗

Quantum-Enhanced Sensing of Axion Dark Matter with a Transmon-Based Single Microwave Photon Counter

We report an axion dark matter search with a haloscope equipped with a microwave photon counter. The haloscope is a tunable high quality factor three-dimensional microwave cavity placed in a magnetic field. The photon counter, operated cyclically, maps an incoming microwave photon onto the state of a superconducting transmon qubit. The measurement protocol continuously monitors the power emitted by the haloscope cavity as well as the dark count background and enables tuning of the cavity frequency to probe different axion masses. With this apparatus, we enhance by a factor of 20 the search speed that can be reached with quantum-limited linear amplifiers and set a new standard for probing the existence of axions with resonant detectors above 5 GHz. Published by the American Physical Society 2025

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Ni partitioning between diopside and silicate melt - A redetermination by ion microprobe and recognition of an experimental complication

The capabilities of and potential problems with ion microprobe analysis are illustrated in the determination of Ni distribution between silicate melt and diopside as a function of concentration. Samples of diopside and a melt in the albite-anorthite-diopside system were doped with Ni to levels of 5.22 and 1.08 wt % and 1060, 138, 42 and 30 ppm, and with 3 ppm of Ni-63, and characterized by both electron and ion microprobe techniques. Measurements of Ni-62 distribution by the ion probe method give a ratio of 1.87 for the ratio of count rates in the diopsides with the glass, which is slightly lower than the value of 2.05 obtained from beta-track mapping. The measurements required the secondary ion signal to be linear with concentration in the range measured, and a calibration to correct for differential secondary ion yields from different phases. It is found, however, that partition coefficients measured for Ni-58 and Ni-60 are not constant with Ni concentration, probably due to Ni migration during crystallization. The results thus show ion microprobe analyses to be feasible for simultaneous measurements of distributions of more than one element, and of elements inappropriate for beta-track mapping or electron probe analysis.

Steele, I. M.↗

Poisson vs. Gaussian statistics for sparse X-ray data: Application to the soft X-ray spectrometer

Reliable results when fitting X-ray data require proper consideration of the statistics involved. We probe the impact of Gaussian versus Poisson statistics at low count levels using both the standard χ^(2) method and maximum likelihood based on Poisson (C) statistics. The difference is studied and quantified through simulated spectra with known properties. We then test the results through analysis of Mn Kα calibration data taken with the flight spare microcalorimeter for the Hitomi soft X-ray spectrometer. Through comparison with simulations, our results show that the χ^(2) method tends to give overly optimistic estimates of the detector energy resolution, in particular when there are few counts. Given an energy resolution of ∼5 eV and a line with about 100 photons, the line width becomes ∼10% lower in the χ^(2) method than in Poisson statistics. This is a consequence of the uncertainties being dominated by counting statistics, and therefore highlights the need to choose the appropriate fit statistic.

Shinya Yamada↗

Number of surface sites and turnover frequencies for oxide catalysts

Unlike for metal catalysts where selective chemisorption probes (H 2 , O 2 , CO and N 2 O) have been successfully applied to count the number of active surface sites and allow determination of TOF values, the analogous situation for oxide catalysts has developed very slowly. The reason for the sluggish development of selective chemisorption probes for oxides is that the same chemisorption probes that work well with metals aren’t compatible with oxides since these chemical probes weakly adsorb on oxides. Methanol, however, is a very reactive molecule that has been found to readily chemisorb on oxides and allows for quantitative determination of the number of active surface sites (Ns). Here, in this mini-review, the determination of the number of active sites by methanol chemisorption is reviewed with examples for pure oxides (one-component oxides), supported oxides (submonolayer, monolayer and above monolayer) and bulk mixed oxides (surface enriched oxide present in submonolayer, monolayer and in excess of monolayer coverages).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Simplicity beneath Complexity: Counting Molecular Electrons Reveals Transients and Kinetics of Photodissociation Reactions

Time-resolved pump-probe gas phase X-ray scattering signals, extrapolated to zero momentum transfer, provide a measure of the number of electrons in a system, an effect that arises from the coherent addition of elastic scattering from the electrons. This allows for the identification of reactive transients and the determination of the chemical reaction kinetics without the need for extensive scattering simulations or complicated inversion of scattering data. We examine the photodissociation reaction of trimethyl amine, and identify two reaction paths upon excitation to the 3p state at 200 nm: a fast dissociation path out of the 3p state to the dimethyl amine radical (16.6±1.2%), and a slower dissociation via internal conversion to the 3s state (83.4±1.2%). The time constants for the two reactions are 640±130 fs and 74±6 ps, respectively. In addition, it is found that the transient dimethyl amine radical has a N-C bond length of 1.45±0.02 Å and a CNC bond angle of 118°±4°.

Minitti, Michael P↗

The response of a fast scintillator screen (YAP:Ce) to low energy ions (0-40 keV) and its use to detect fast-ion-loss in stellarator TJ-II

A systematic study of scintillation materials was undertaken to improve the time resolution of the fast ion diagnostic currently installed at TJ-II stellarator. It was found that YAP:Ce (formula YAlO{sub 3}:Ce, Yttrium Aluminum Perovskite doped with Cerium) ionoluminescence offers better sensitivity and time response compared to the standard detector material, SrGa{sub 2}S{sub 4}:Eu (TG-Green), currently used in TJ-II. A comparison between both materials was carried out by irradiating them with H{sup +} ions of up to 40 keV using a dedicated laboratory setup. It is found that for the low energy ions of interest at TJ-II, YAP:Ce offers 20 times higher sensitivity than TG-Green and much faster decay time, 27 ns versus 540 ns. It is expected that the use of YAP:Ce in combination with a faster data acquisition and an ion counting software as part of the TJ-II ion luminescent probe will provide 20 times faster data on ion loss.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗