Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “predictor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Predictors of Local Control After Single-Dose Stereotactic Image-Guided Intensity-Modulated Radiotherapy for Extracranial Metastases

Purpose: To report tumor local control after treatment with single-dose image-guided intensity-modulated radiotherapy (SD-IGRT) to extracranial metastatic sites. Methods and Materials: A total of 126 metastases in 103 patients were treated with SD-IGRT to prescription doses of 18-24 Gy (median, 24 Gy) between 2004 and 2007. Results: The overall actuarial local relapse-free survival (LRFS) rate was 64% at a median follow-up of 18 months (range, 2-45 months). The median time to failure was 9.6 months (range, 1-23 months). On univariate analysis, LRFS was significantly correlated with prescription dose (p = 0.029). Stratification by dose into high (23 to 24 Gy), intermediate (21 to 22 Gy), and low (18 to 20 Gy) dose levels revealed highly significant differences in LRFS between high (82%) and low doses (25%) (p < 0.0001). Overall, histology had no significant effect on LRFS (p = 0.16). Renal cell histology displayed a profound dose-response effect, with 80% LRFS at the high dose level (23 to 24 Gy) vs. 37% with low doses ({<=}22 Gy) (p = 0.04). However, for patients who received the high dose level, histology was not a statistically significant predictor of LRFS (p = 0.90). Target organ (bone vs. lymph node vs. soft tissues) (p = 0.5) and planning target volume size (p = 0.55) were not found to be associated with long-term LRFS probability. Multivariate Cox regression analysis confirmed prescription dose to be a significant predictor of LRFS (p = 0.003). Conclusion: High-dose SD-IGRT is a noninvasive procedure resulting in high probability of local tumor control. Single-dose IGRT may be effectively used to locally control metastatic deposits regardless of histology and target organ, provided sufficiently high doses (> 22 Gy) of radiation are delivered.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Preoperative Chemoradiotherapy (CRT) Followed by Laparoscopic Surgery for Rectal Cancer: Predictors of the Tumor Response and the Long-Term Oncologic Outcomes

Purpose: We have evaluated the predictors of a tumor response to chemoradiotherapy (CRT) and the long-term oncologic outcomes of preoperative CRT and laparoscopic surgery for patients who suffer from rectal cancer. Methods and Materials: The study involved 274 patients with locally advanced rectal cancer and who had been treated with preoperative CRT and curative laparoscopic total mesorectal excision between January 2003 and January 2009. We assessed the long-term oncologic outcomes, in terms of recurrence and survival, of the treated patients. Results: Forty-two (15.3%) of the 274 patients had complete pathologic responses (pCR). The pre-CRT carcinoembryonic antigen level was the only significant predictor of a pCR on the multivariate analysis (p = 0.01). The overall survival at 5 years was 73.1%, with a mean survival period of 59.7 months (95% CI, 57.1-62.3). The disease-free survival at 5 years was 67.3% with a mean survival period of 54.7 months (95% CI, 51.7-57.8). The pCR group had a higher rate of overall survival at 5 years than did the non-pCR group, and the difference was significant (86.0% vs. 71.2%; hazard ratio = 0.87; 95% CI, 0.78-0.96; p = 0.03). The cumulative incidences of local and distant recurrences at 5 years were 5.8% and 28.3%, respectively. A total of 84.5% (234 of 274) of the patients had their anal sphincters preserved. Grade 3 or 4 acute and long-term toxic effects occurred in 22.2% and 8.4% of the patients, respectively. Conclusion: Preoperative CRT and laparoscopic surgery seems safe and feasible with favorable long-term outcomes and a high rate of sphincter preservation for the patients with low-lying tumors of the rectum.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Primary Tumor Volume Is an Important Predictor of Clinical Outcomes Among Patients With Locally Advanced Squamous Cell Cancer of the Head and Neck Treated With Definitive Chemoradiotherapy

Purpose: The tumor volume has been established as a significant predictor of outcomes among patients with head-and-neck cancer undergoing radiotherapy alone. The present study attempted to add to the existing data on tumor volume as a prognostic factor among patients undergoing chemoradiotherapy. Methods and Materials: A total of 78 patients who had undergone definitive chemoradiotherapy for Stage III-IV squamous cell cancer of the hypopharynx, oropharynx, and larynx were identified. The primary tumor volumes were calculated from the treatment planning computed tomography scans, and these were correlated to the survival and tumor control data obtained from the retrospective analysis. Results: The interval to progression correlated with the primary tumor volume (p = .007). The critical cutoff point for the tumor volume was identified as 35 cm{sup 3}, and patients with a tumor volume <35 cm{sup 3} had a significantly better prognosis than those with a tumor volume >35 cm{sup 3} at 5 years (43% vs. 71%, p = .010). Longer survival was also correlated with smaller primary tumor volumes (p = .022). Similarly, patients with a primary tumor volume <35 cm{sup 3} had a better prognosis in terms of both progression-free survival (61% vs. 33%, p = .004) and overall survival (84% vs. 41%, p = < .001). On multivariate analysis, the primary tumor volume was the best predictor of recurrence (hazard ratio 4.7, 95% confidence interval 1.9-11.6; p = .001) and survival (hazard ratio 10.0, 95% confidence interval 2.9-35.1; p = < .001). In contrast, the T stage and N stage were not significant factors. Analysis of variance revealed that tumors with locoregional failure were on average 21.6 cm{sup 3} larger than tumors without locoregional failure (p = .028) and 27.1-cm{sup 3} larger than tumors that recurred as distant metastases (p = .020). Conclusion: The results of our study have shown that the primary tumor volume is a significant prognostic factor in patients with advanced cancer of the head and neck undergoing definitive chemoradiotherapy and correlated with the treatment outcomes better than the T or N stage.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Predictors of Toxicity After Image-guided High-dose-rate Interstitial Brachytherapy for Gynecologic Cancer

Purpose: To identify predictors of grade 3-4 complications and grade 2-4 rectal toxicity after three-dimensional image-guided high-dose-rate (HDR) interstitial brachytherapy for gynecologic cancer. Methods and Materials: Records were reviewed for 51 women (22 with primary disease and 29 with recurrence) treated with HDR interstitial brachytherapy. A single interstitial insertion was performed with image guidance by computed tomography (n = 43) or magnetic resonance imaging (n = 8). The median delivered dose in equivalent 2-Gy fractions was 72.0 Gy (45 Gy for external-beam radiation therapy and 24 Gy for brachytherapy). Toxicity was reported according to the Common Toxicity Criteria for Adverse Events. Actuarial toxicity estimates were calculated by the Kaplan-Meier method. Results: At diagnosis, the median patient age was 62 years and the median tumor size was 3.8 cm. The median D90 and V100 were 71.4 Gy and 89.5%; the median D2cc for the bladder, rectum, and sigmoid were 64.6 Gy, 61.0 Gy, and 52.7 Gy, respectively. The actuarial rates of all grade 3-4 complications at 2 years were 20% gastrointestinal, 9% vaginal, 6% skin, 3% musculoskeletal, and 2% lymphatic. There were no grade 3-4 genitourinary complications and no grade 5 toxicities. Grade 2-4 rectal toxicity was observed in 10 patients, and grade 3-4 complications in 4; all cases were proctitis with the exception of 1 rectal fistula. D2cc for rectum was higher for patients with grade 2-4 (68 Gy vs 57 Gy for grade 0-1, P=.03) and grade 3-4 (73 Gy vs 58 Gy for grade 0-2, P=.02) rectal toxicity. The estimated dose that resulted in a 10% risk of grade 2-4 rectal toxicity was 61.8 Gy (95% confidence interval, 51.5-72.2 Gy). Discussion: Image-guided HDR interstitial brachytherapy results in acceptable toxicity for women with primary or recurrent gynecologic cancer. D2cc for the rectum is a reliable predictor of late rectal complications. Three-dimensional-based treatment planning should be performed to ensure adequate tumor coverage while minimizing the D2cc to the rectum.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Biopsy Specimens Obtained 7 Days After Starting Chemoradiotherapy (CRT) Provide Reliable Predictors of Response to CRT for Rectal Cancer

Purpose: Preoperative chemoradiation therapy (CRT) significantly decreases local recurrence in locally advanced rectal cancer. Various biomarkers in biopsy specimens obtained before CRT have been proposed as predictors of response. However, reliable biomarkers remain to be established. Methods and Materials: The study group comprised 101 consecutive patients with locally advanced rectal cancer who received preoperative CRT with oral uracil/tegafur (UFT) or S-1. We evaluated histologic findings on hematoxylin and eosin (H and E) staining and immunohistochemical expressions of Ki67, p53, p21, and apoptosis in biopsy specimens obtained before CRT and 7 days after starting CRT. These findings were contrasted with the histologic response and the degree of tumor shrinkage. Results: In biopsy specimens obtained before CRT, histologic marked regression according to the Japanese Classification of Colorectal Carcinoma (JCCC) criteria and the degree of tumor shrinkage on barium enema examination (BE) were significantly greater in patients with p21-positive tumors than in those with p21-negative tumors (P=.04 and P<.01, respectively). In biopsy specimens obtained 7 days after starting CRT, pathologic complete response, histologic marked regression according to both the tumor regression criteria and JCCC criteria, and T downstaging were significantly greater in patients with apoptosis-positive and p21-positive tumors than in those with apoptosis-negative (P<.01, P=.02, P=.01, and P<.01, respectively) or p21-negative tumors (P=.03, P<.01, P<.01, and P=.02, respectively). The degree of tumor shrinkage on both BE as well as MRI was significantly greater in patients with apoptosis-positive and with p21-positive tumors than in those with apoptosis-negative or p21-negative tumors, respectively. Histologic changes in H and E-stained biopsy specimens 7 days after starting CRT significantly correlated with pathologic complete response and marked regression on both JCCC and tumor regression criteria, as well as with tumor shrinkage on BE and MRI (P<.01, P<.01, P<.01, P<.01, and P=.03, respectively). Conclusions: Immunohistochemical expressions of p21 and apoptosis together with histologic changes on H and E-stained biopsy specimens obtained 7 days after starting CRT are strong predictors of the response to CRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Predictors of Radiation Therapy Noncompliance in an Urban Academic Cancer Center

Purpose: To quantify the frequency of patient noncompliance in an urban radiation oncology department and identify predictors of noncompliance. Methods and Materials: We identified patients treated with external beam radiation therapy (RT) with curative intent in our department from 2007 to 2012 for 1 of 7 commonly treated malignancies. Patients who missed 2 or more scheduled RT appointments were deemed “noncompliant.” An institutional database was referenced to obtain clinical and demographic information for each patient, as well as a quantitative estimate of each patient's socioeconomic status. Logistic regression was used to identify factors associated with RT noncompliance. Results: A total of 2184 patients met eligibility criteria. Of these, 442 (20.2%) were deemed “noncompliant.” On multivariate analysis, statistically significant predictors of noncompliance included diagnosis of head-and-neck, cervical, or uterine cancer, treatment during winter months, low socioeconomic status, and use of a long treatment course (all P<.05). Conclusion: This is the first large effort examining patient noncompliance with daily RT. We have identified demographic, clinical, and treatment-related factors that can be used to identify patients at high risk for noncompliance. These findings may inform future strategies to improve adherence to prescribed therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Temporal Evolution and Dose-Volume Histogram Predictors of Visual Acuity After Proton Beam Radiation Therapy of Uveal Melanoma

Purpose: To perform an in-depth temporal analysis of visual acuity (VA) outcomes after proton beam radiation therapy (PBRT) in a large, uniformly treated cohort of uveal melanoma (UM) patients, to determine trends in VA evolution depending on pretreatment and temporally defined posttreatment VA measurements; and to investigate the relevance of specific patient, tumor and dose-volume parameters to posttreatment vision loss. Methods and Materials: Uveal melanoma patients receiving PBRT were identified from a prospectively maintained database. Included patients (n=645) received 56 GyE in 4 fractions, had pretreatment best corrected VA (BCVA) in the affected eye of count fingers (CF) or better, with posttreatment VA assessment at specified post-PBRT time point(s). Patients were grouped according to the pretreatment BCVA into favorable (≥20/40) or unfavorable (20/50-20/400) and poor (CF) strata. Temporal analysis of BCVA changes was described, and univariate and forward stepwise multivariate logistic regression analyses were performed to identify predictors for VA loss. Results: Median VA follow-up was 53 months (range, 3-213 months). At 60-month follow up, among evaluable treated eyes with favorable pretreatment BCVA, 45% retained BCVA ≥20/40, whereas among evaluable treated eyes with initially unfavorable/poor BCVA, 21% had vision ≥20/100. Among those with a favorable initial BCVA, attaining BCVA of ≥20/40 at any posttreatment time point was associated with subsequent maintenance of excellent BCVA. Multivariate analysis identified volume of the macula receiving 28GyE (P<.0001) and optic nerve (P=.0004) as independent dose-volume histogram predictors of 48-month post-PBRT vision loss among initially favorable treated eyes. Conclusions: Approximately half of PBRT-treated UM eyes with excellent pretreatment BCVA assessed at 5 years after treatment will retain excellent long-term vision. 28GyE macula and optic nerve dose-volume histogram parameters allow for rational treatment planning optimization that may lead to improved visual outcomes. The detailed temporal analysis with intermediate as well as long-term functional prognosis, and the relationship of outcomes with clinical and treatment planning parameters, is critical for informed care of UM patients before and after PBRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hierarchical-embedding autoencoder with a predictor as efficient architecture for learning time-evolution in multi-scale turbulent flows

We introduce a scale-aware, data-driven deep learning modeling framework for accurately predicting the time evolution of multi-scale turbulent plasma and liquid flows. The approach is motivated by the idea of scale separation. Structures of vastly different length scales emerge in these systems, and interactions between these structures occur only locally. To exploit this structure, the flow state is transformed by a hierarchical, fully convolutional autoencoder, not into a single embedding layer as in conventional convolutional surrogate models, but into a series of embedding layers. A stepwise training strategy ensures that fine-scale features are encoded on a high-resolution grid, while larger structures are represented on progressively coarser layers. The time evolution predictor advances all embedding layers in sync, capturing local interactions between features at the same scale as well as between all scales. This approach enables efficient modeling of multi-scale systems since negligible interactions between distant, small-scale structures do not need to be directly modeled. Our hierarchical-embedding autoencoder with a predictor framework is evaluated on canonical examples of multi-scale turbulence: two-dimensional Kolmogorov flow and Hasegawa–Wakatani plasma turbulence. In both cases, the proposed framework significantly improves predictive accuracy relative to conventional convolutional network architectures. A significant improvement in prediction accuracy was observed for crucial statistical characteristics of the Hasegawa–Wakatani plasma as well as for individual trajectories of the Kolmogorov flow turbulence. Importantly, the model's rollout for the Hasegawa–Wakatani problem demonstrates a four-order-of-magnitude speedup compared to traditional numerical solvers.

Khrabry, Alexander I. [Princeton Univ., NJ (United↗

The ASHRAE Great Energy Predictor III competition: Overview and results

In late 2019, ASHRAE hosted the Great Energy Predictor III (GEPIII) machine learning competition on the Kaggle platform. This launch marked the third energy prediction competition from ASHRAE and the first since the mid-1990s. In this updated version, the competitors were provided with over 20 million points of training data from 2,380 energy meters collected for 1,448 buildings from 16 sources. This competition’s overall objective was to find the most accurate modeling solutions for the prediction of over 41 million private and public test data points. Furthermore, the competition had 4,370 participants, split across 3,614 teams from 94 countries who submitted 39,403 predictions. In addition to the top five winning workflows, the competitors publicly shared 415 reproducible online machine learning workflow examples (notebooks), including over 40 additional, full solutions. This paper gives a high-level overview of the competition preparation and dataset, competitors and their discussions, machine learning workflows and models generated, winners and their submissions, discussion of lessons learned, and competition outputs and next steps. The most popular and accurate machine learning workflows used large ensembles of mostly gradient boosting tree models, such as LightGBM. Similar to the first predictor competition, preprocessing of the data sets emerged as a key differentiator.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A NEW EIGHT-STEP SYMMETRIC EMBEDDED PREDICTOR-CORRECTOR METHOD (EPCM) FOR ORBITAL PROBLEMS AND RELATED IVPs WITH OSCILLATORY SOLUTIONS

A new multistep predictor-corrector (PC) pair form is introduced for the numerical integration of second-order initial-value problems. Using this form, a new eight-step symmetric embedded predictor-corrector method is constructed. The new PC method is based on the multistep symmetric method of Quinlan and Tremaine, with eight steps and eighth algebraic order, and is constructed to solve numerically the N-body problem. The new integrator has algebraic order 10 and it can be used to solve problems, for which the frequency is not known. We investigate the behavior of the new algorithm by integrating the five outer-planet problem and the two-body problem with various eccentricities. Regarding the five outer-planet problem, we calculate the error of the integrator in the solution, the Hamiltonian, and the phase after forward and backward integration over various intervals that are multiples of the period of Jupiter.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-G-TeP1-11: Predictors of Cardiac and Lung Dose Sparing in DIBH for Left Breast Treatment

Purpose: This retrospective study of left sided whole breast radiation therapy (RT) patients investigates possible predictive parameters correlating to cardiac and left lung dose sparing by deep inspiration breath-hold (DIBH) technique compared to free-breathing (FB). Methods: Thirty-one patients having both DIBH and FB CT scans were included in the study. All patients were planned with a standard step-and-shoot tangential technique using MV photons, with prescription of 50Gy or 50.4Gy. The displacement of the breath hold sternal mark during DIBH, the cardiac contact distances of the axial (CCDax) and parasagittal (CCDps) planes, and lateral-heart-to-chest (LHC) distance on FB CT scans were measured. Lung volumes, mean dose and dose-volume histograms (V5, V10 and V20) were analyzed and compared for heart and left lung for both FB and DIBH techniques. Correlation analysis was performed to identify the predictors for heart and left lung dose sparing. Two-tailed Student’s t-test and linear regression were used for data analysis with significance level of P≤0.05. Results: All dosimetric metrics for the heart and left lung were significantly reduced (P<0.01) with DIBH. Breath hold sternal mark displacement ranged from 0.4–1.8 cm and correlated with mean (P=0.05) and V5 (P=0.02) of heart dose reduction by DIBH. FB lung volume showed correlation with mean lung dose reduction by DIBH (P<0.01). The FB-CCDps and FB-LHC distance had strong positive and negative correlation with FB mean heart dose (P<0.01) and mean heart dose reduction by DIBH (P<0.01), respectively. FB-CCDax showed no correlation with dosimetric changes. Conclusion: DIBH technique has been shown to reduce dose to the heart and left lung. In this patient cohort, FB-CCDps, FB-LHC distance, and FB lung volume served as significant predictors for heart and left lung. These parameters can be further investigated to be used as a tool to better select patients who will benefit from DIBH.

60 APPLIED LIFE SCIENCES↗

Electrical capacitance as a predictor of root dry weight in shrub willow ( Salix ; Salicaceae) parents and progeny

Premise of the study: Root biomass is an important trait often disregarded in woody perennial selection due to the challenge and expense of accurately and efficiently measuring large populations. In this study, we aim to develop a simple method that can predict root dry weight within a diverse shrub willow ( Salix ) breeding population representing species hybrids and their parents using root electrical capacitance (REC). Methods: The REC method was tested on plants started from cuttings and grown in pots with potting mix in the greenhouse for 11 wk to assess the relationship of REC with 24 biomass traits and its usefulness in allometric models for root and stem dry biomass. Results: Strong linear and positive correlations were found between REC and root dry biomass ( r = 0.88). The total proportion of variance of root and stem dry biomass explained by predictors in multiple regression was 85% and 69%, respectively. The relative importance of predictor variables in allometric models was dominated by the contribution of REC. Discussion: This work provides an efficient and nondestructive technique to indirectly quantify root biomass of genetically diverse shrub willow progeny, which has great promise for selection of genotypes with varying root biomass and for the accurate estimation of belowground carbon sequestration.

59 BASIC BIOLOGICAL SCIENCES↗

What is Important? Morphological Asymmetries are Useful Predictors of Star Formation Rates of Star-forming Galaxies in SDSS Stripe 82

The morphology and structure of galaxies reflect their star formation and assembly histories. We use the framework of mutual information (MI) to quantify the interdependence among several structural variables and to rank them according to their relevance for predicting the specific star formation rate (SSFR) by comparing the MI of the predictor variables with the SSFR and penalizing variables that are redundant. We apply this framework to study ~3700 face-on star-forming galaxies (SFGs) with varying degrees of bulge dominance and central concentration and with stellar mass $M$ * ≈ 10 9 $M$ ⊙ at redshift $z$ = 0.02–0.12. We use the Sloan Digital Sky Survey (SDSS) Stripe 82 deep $i$-band imaging data, which improve measurements of asymmetry and bulge dominance indicators. We find that star-forming galaxies are a multiparameter family. In addition to $M$ * , asymmetry emerges as the most powerful predictor of SSFR residuals of SFGs, followed by bulge prominence/concentration. Star-forming galaxies with higher asymmetry and stronger bulges have higher SSFR at a given $M$ * . In conclusion, the asymmetry reflects both irregular spiral arms and lopsidedness in seemingly isolated SFGs and structural perturbations by galaxy interactions or mergers.

79 ASTRONOMY AND ASTROPHYSICS↗

Analysis of a VTOL hover task with predictor displays using an optimal control model of the human operator

The influence of different types of predictor displays in a longitudinal VTOL hover task is analyzed in a theoretical study. It was assumed that pitch angle and position are presented to the pilot in separate displays namely the artificial horizon and position display. The predictive information is calculated by means of a Taylor series. From earlier experimental studies it is well known that predictor displays improve human and system performance and result in reducing human workload. In this study, an optimal control model is used to prove this effect theoretically. Several cases with differing amounts of predictive and rate information are compared.

Johannsen, G.↗

An analysis of the human as a predictor model

A hybrid sampled data-continuous impulse response of a preview tracker using a fast time model predictor aid is derived. The model can accept transient and nontransient imputs and is suitable for studying a human preview tracker using an internalized or externalized predictor display. The model is shown to behave reasonably in a simple example and its implications for modeling studies are discussed.

Kreifeldt, J. G.↗

An estimator-predictor approach to PLL loop filter design

An approach to the design of digital phase locked loops (DPLLs), using estimation theory concepts in the selection of a loop filter, is presented. The key concept is that the DPLL closed-loop transfer function is decomposed into an estimator and a predictor. The estimator provides recursive estimates of phase, frequency, and higher order derivatives, while the predictor compensates for the transport lag inherent in the loop. This decomposition results in a straightforward loop filter design procedure, enabling use of techniques from optimal and sub-optimal estimation theory. A design example for a particular choice of estimator is presented, followed by analysis of the associated bandwidth, gain margin, and steady state errors caused by unmodeled dynamics. This approach is under consideration for the design of the Deep Space Network (DSN) Advanced Receiver Carrier DPLL.

Statman, J. I.↗

Satellite orbit predictor

An analog aid to determine satellite coverage of Emergency Locator Transmitters Emergency Position Indicating Radio Beacon (ELT/EPIRB) distress incidence is discussed. The satellite orbit predictor is a graphical aid for determining the relationship between the satellite orbit, antenna coverage of the spacecraft and coverage of the Local User Terminal. The predictor allows the user to quickly visualize if a selected position will probably be detected and is composed of a base map and a satellite track overlay for each satellite.A table of equator crossings for each satellite is included.

Friedman, Morton l.↗

COSPAS-SARSAT Satellite Orbit Predictor. Volume 3

The satellite orbit predictor is a graphical aid for determining the relationship between the satellite (SARSAT or COSPAS) orbit, antenna coverage of the spacecraft and coverage of the LUTs. The predictor allows the user to quickly visualize if a selected position will probably be detected and is composed of a base map and a satellite track overlay for each satellite. Additionally, a table of equator crossings for each satellite is included.

Friedman, Morton L.↗