Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “precision”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Precision spectroscopy and laser-cooling scheme of a radium-containing molecule

Molecules containing heavy radioactive nuclei are predicted to be extremely sensitive to violations of the fundamental symmetries of nature. The nuclear octupole deformation of certain radium isotopes massively boosts the sensitivity of radium monofluoride molecules to symmetry-violating nuclear properties. Moreover, these molecules are predicted to be laser coolable. In this article, we report measurements of the rovibronic structure of radium monofluoride molecules, which allow the determination of their laser cooling scheme. We demonstrate an improvement in resolution of more than two orders of magnitude compared to the state of the art. Our developments allowed measurements of minuscule amounts of hot molecules, with only a few hundred per second produced in a particular rotational state. The combined precision and sensitivity achieved in this work offer opportunities for studies of radioactive molecules of interest in fundamental physics, chemistry and astrophysics.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Interacting dark sector and precision cosmology

We consider a recently proposed model in which dark matter interacts with a thermal background of dark radiation. Dark radiation consists of relativistic degrees of freedom which allow larger values of the expansion rate of the universe today to be consistent with CMB data (H 0 -problem). Scattering between dark matter and radiation suppresses the matter power spectrum at small scales and can explain the apparent discrepancies between ΛCDM predictions of the matter power spectrum and direct measurements of Large Scale Structure LSS (σ 8 -problem). We go beyond previous work in two ways: 1. we enlarge the parameter space of our previous model and allow for an arbitrary fraction of the dark matter to be interacting and 2. we update the data sets used in our fits, most importantly we include LSS data with full k-dependence to explore the sensitivity of current data to the shape of the matter power spectrum. We find that LSS data prefer models with overall suppressed matter clustering due to dark matter - dark radiation interactions over ΛCDM at 3-4 σ. However recent weak lensing measurements of the power spectrum are not yet precise enough to clearly distinguish two limits of the model with different predicted shapes for the linear matter power spectrum. In two Appendices we give a derivation of the coupled dark matter and dark radiation perturbation equations from the Boltzmann equation in order to clarify a confusion in the recent literature, and we derive analytic approximations to the solutions of the perturbation equations in the two physically interesting limits of all dark matter weakly interacting or a small fraction of dark matter strongly interacting.

79 ASTRONOMY AND ASTROPHYSICS↗

Precision benchmark calculations for four particles at unitarity

The unitarity limit describes interacting particles where the range of the interaction is zero and the scattering length is infinite. We present precision benchmark calculations for two-component fermions at unitarity using three different ab initio methods: Hamiltonian lattice formalism using iterated eigenvector methods, Euclidean lattice formalism with auxiliary-field projection Monte Carlo methods, and continuum diffusion Monte Carlo methods with fixed and released nodes. We have calculated the ground-state energy of the unpolarized four-particle system in a periodic cube as a dimensionless fraction of the ground-state energy for the noninteracting system. We obtain values of 0.211(2) and 0.210(2) using two different Hamiltonian lattice representations, 0.206(9) using Euclidean lattice formalism, and an upper bound of 0.212(2) from fixed-node diffusion Monte Carlo methods. Released-node calculations starting from the fixed-node result yield a decrease of less than 0.002 over a propagation of 0.4E{sub F}{sup -1} in Euclidean time, where E{sub F} is the Fermi energy. We find good agreement among all three ab initio methods.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Precision measurement of the top-quark mass in lepton+jets final states

We measure the mass of the top quark in lepton$+$jets final states using the full sample of $p\bar{p}$ collision data collected by the D0 experiment in Run II of the Fermilab Tevatron Collider at $\sqrt s=1.96 $TeV, corresponding to $9.7 {\rm fb}^{-1}$ of integrated luminosity. We use a matrix element technique that calculates the probabilities for each event to result from $t\bar t$ production or background. The overall jet energy scale is constrained in situ by the mass of the $W$ boson. We measure $m_t=174.98\pm0.76$ GeV. In conclusion, this constitutes the most precise single measurement of the top-quark mass.

43 PARTICLE ACCELERATORS↗

A priori precision estimation for neutron triples counting

The nondestructive assay of Plutonium bearing items for criticality, safety, security, safeguards, inventory balance, process control, waste management and compliance is often undertaken using correlated neutron counting. In particular Multiplicity Shift Register analysis allows one to extract autocorrelation parameters from the pulse train which can, within the framework of a simple interpretational model, be related to the effective {sup 240}Pu spontaneous fission mass present. The effective {sup 240}Pu mass is a weighted sum of the {sup 238}Pu, {sup 240}Pu and {sup 242}Pu masses so if the relative isotopic composition of the Pu can be established from the measured {sup 240}Pu effective mass one can estimate the total Pu mass and also the masses of the individual isotopes, example the fissile species {sup 239}Pu and {sup 241}Pu. In multiplicity counting three counting rates are obtained. These are the Singles, Doubles and Triples rates. The Singles rate is just the gross, totals or trigger rate. The Doubles and Triples rates are calculated from factorial moments of the observed signal triggered neutron multiplicity distributions following spontaneous fission in the item and can be thought of as the rate of observed coincident pairs and coincident triplets on the pulse train. Coincident events come about because the spontaneous fission and induced fission chains taking place in the item result in bursts of neutrons. These remain time correlated during the detection process and so retain information, through the burst size distribution, about the Pu content. In designing and assessing the performance of a detector system to meet a given goal it is necessary to make a priori estimates of the counting precision for all three kinds of rates. This is non-trivial because the counting does not obey the familiar rules of a Poissonian counting experiment because the pulse train has time correlated events on it and the train is sampled by event triggered gates that may overlap. For Singles and Doubles simple approximate analytical empirical rules for how to estimate the variance have been developed guided by theory and refined by experiment. However, for Triples no equivalent rules have been put forward and tested until now. In this work we propose an analytical expression, the CSH relation, for the variance on the Triples count and exercise it against experimental data gathered for Pu items measured in the Los Alamos National Laboratory's Epithermal Neutron Multiplicity Counter (ENMC). Preliminary results are encouraging and reasonable agreement with observation, considered fit for scoping studies, is obtained. We have also looked at the behavior using Monte Carlo simulations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

High-precision measurements of the compressibility and the electrical resistivity of bulk g-As{sub 2}Te{sub 3} glasses at a hydrostatic pressure up to 8.5 GPa

High-precision studies of the volume and the electrical resistivity of g-As{sub 2}Te{sub 3} glasses at a high hydrostatic pressure up to 8.5 GPa at room temperature are performed. The glasses exhibit elastic behavior in compression only at a pressure up to 1 GPa, and a diffuse structural transformation and inelastic density relaxation (logarithmic in time) begin at higher pressures. When the pressure increases further, the relaxation rate passes through a sharp maximum at 2.5 GPa, which is accompanied by softening the relaxing bulk modulus, and then decreases, being noticeable up to the maximum pressure. When pressure is relieved, an unusual inflection point is observed in the baric dependence of the bulk modulus near 4 GPa. The polyamorphic transformation is only partly reversible and the residual densification after pressure release is 2%. In compression, the electrical resistivity of the g-As{sub 2}Te{sub 3} glasses decreases exponentially with increasing pressure (at a pressure up to 2 GPa); then, it decreases faster by almost three orders of magnitude in the pressure range 2–3.5 GPa. At a pressure of 5 GPa, the electrical resistivity reaches 10{sup –3} Ω cm, which is characteristic of a metallic state; this resistivity continues to decrease with increasing pressure and reaches 1.7 × 10{sup –4} Ω cm at 8.1 GPa. The reverse metal–semiconductor transition occurs at a pressure of 3 GPa when pressure is relieved. When the pressure is decreased to atmospheric pressure, the electrical resistivity of the glasses is below the initial pressure by two–three orders of magnitude. Under normal conditions, both the volume and the electrical resistivity relax to quasi-equilibrium values in several months. Comparative structural and Raman spectroscopy investigations demonstrate that the glasses subjected to high pressure have the maximum chemical order. The glasses with a higher order have a lower electrical resistivity. The polyamorphism in the As{sub 2}Te{sub 3} glasses is caused by both structural changes and chemical ordering. The g-As{sub 2}Te{sub 3} compound is the first example of glasses, where the reversible metallization under pressure has been studied under hydrostatic conditions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A High-Precision Instrument for Mapping of Rotational Errors in Rotary Stages

A rotational stage is a key component of every X-ray instrument capable of providing tomographic or diffraction measurements. To perform accurate three-dimensional reconstructions, runout errors due to imperfect rotation (e.g. circle of confusion) must be quantified and corrected. A dedicated instrument capable of full characterization and circle of confusion mapping in rotary stages down to the sub-10 nm level has been developed. A high-stability design, with an array of five capacitive sensors, allows simultaneous measurements of wobble, radial and axial displacements. The developed instrument has been used for characterization of two mechanical stages which are part of an X-ray microscope.

36 MATERIALS SCIENCE↗