Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power system relaying”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Pulsed radio frequency interference effects on data communications via satellite transponder

Power-limited communication links may be susceptible to significant degradation if intentional or unintentional pulsed high level radio frequency interference (RFI) is present. Pulsed RFI is, in fact, of current interest to NASA in studies relating to its Tracking and Data Relay Satellite System (TDRSS). The present paper examines the impact of pulsed RFI on the error probability performance of a power-limited satellite communication link: the assumed modulation scheme is PN coded binary PSK. The composite effects of thermal noise, pulsed CW and pulsed Gaussian noise are analyzed, where RFI arrivals are assumed to follow Poisson statistics. Under the assumption that the satellite repeater is ideal and that integrate and dump filtering is employed at the ground receiver, an exact error probability expression and associated approximations are derived. Computed results are generated using an arbitrarily specified RFI model.

Weinberg, A.↗

Major RFI conditions effecting TDRSS

An evaluation of the radio frequency interference (RFI) conditions which would affect operating frequency band selections and data communications equipment design approaches for the Tracking Data Relay Satellite System (TDRSS) is presented. The subjects discussed are: (1) the scope of the investigation, (2) relative RFI in the frequency bands considered, (3) radar RFI power and duty factor, (4) radio relay communications RFI, (5) radio frequency band usage recommendations, and (6) radar RFI impact areas.

Lyttle, J. D.↗

Incipient fault detection and power system protection for spaceborne systems

A program was initiated to study the feasibility of using advanced terrestrial power system protection techniques for spacecraft power systems. It was designed to enhance and automate spacecraft power distribution systems in the areas of safety, reliability and maintenance. The proposed power management/distribution system is described as well as security assessment and control, incipient and low current fault detection, and the proposed spaceborne protection system. It is noted that the intelligent remote power controller permits the implementation of digital relaying algorithms with both adaptive and programmable characteristics.

Russell, B. Don↗

Circuit Stops Prelasing In A Q-Switched Laser

Protective shutdown circuit stops prelasing in Q-switched laser operating at pulse-repetition rate of about 10 Hz. During normal operation, Q-switch prevents emission of light from laser cavity during application of Q-switch-trigger pulse. When circuit detects prelasing, it triggers relay turning off laser power supply. Circuit integrated into almost any Q-switched-laser system, provided one gains access to laser light, Q-switch-trigger pulse, and safety-interlock line of laser power supply.

Lockard, George E.↗

Low Power Transceiver

One of the FREESTAR experiments, the Low Power Transceiver (LPT) experiment is a low-power, lightweight software programmable transceiver prototype technology demonstration that is being developed by NASA as a low-cost S-band spacecraft navigation and communication device. The LPT prototype receives Global Positioning System (GPS) satellite signals for spacecraft navigation support and provides both forward and return, low-rate data communications links to the Merritt Island (MILA) and Dryden Flight Research Facility (DFRC) ground stations and to the Tracking and Data Relay Satellite System (TDRSS). The experiment is designed to demonstrate the system's ability to do simultaneous communications and navigation, as well as multi-mode communications and reconfiguration. LPT is managed by NASA's Goddard Space Flight Center and sponsored by NASA/HQ Code M. The LPT experiment consists of one thermally conductive box containing the electronics stack, three S-band antennas and one L-band antenna. The LPT payload uses general Orbiter services, including power control, command, and telemetry provided through the HHC avionics. On-orbit, the LPT payload will be primarily operated via direct communications between LPT and ground stations (MILA, WLPS, or DFRC) and/or TDRSS, with backup command and telemetry capability provided via the hitchhiker avionics and remote Payload Operations Control Center. During operations, LPT will utilize high Sband frequencies for communications. The LPT TDRSS (and GN) forward link (uplink) frequency is 2106.40625 MHz and their TDRSS (and GN) return link (downlink) frequency is 2287.5 MHz (utilizing Left-handed Circular Polarization to work with the TDRSS MA system). Two standard switch panel switches will be utilized to prohibit inadvertent operation of the antenna. An additional inhibit will be provided through the HH avionics power relay to the LPT.

Source record↗

Cloud-based Testbed for Adaptive Under-Frequency Load Shedding with High DER Penetration

Increasing penetration of distributed energy resources and behind-the-meter renewables may soon disrupt the efficacy of critical protection schemes, such as under-frequency load shedding (UFLS). Improved data exchange and coordination across the transmission-distribution boundary will be required to maintain reliability of bulk electric system. Standards-based data integration platforms using agreed-upon semantic vocabularies, such as the Common Information Model, will be key to enabling adaptive protection schemes requiring synthesized data from both the bulk power system and behind-the-meter resources. This paper introduces a cloud-based open-source data integration environment and UFLS clustering algorithm being developed to enable adaptive relay coordination between transmission and distribution utilities in the state of Vermont.

Anderson, Alexander A.↗

Wireless Instrumentation System and Power Management Scheme Therefore

A wireless instrumentation system enables a plurality of low power wireless transceivers to transmit measurement data from a plurality of remote station sensors to a central data station accurately and reliably. The system employs a relay based communications scheme where remote stations that cannot communicate directly with the central station due to interference, poor signal strength, etc., are instructed to communicate with other of the remote stations that act as relays to the central station. A unique power management scheme is also employed to minimize power usage at each remote station and thereby maximize battery life. Each of the remote stations prefembly employs a modular design to facilitate easy reconfiguration of the stations as required.

Perotti, Jose↗

Behavior of Single-Line-Ground Faults in Inverter-Based Resource Dominated Grids Explained

It has been observed by protection engineers that it is difficult for a protective relay to identify the faulted phase during a single-line-ground (SLG) fault in a power system with a high ingression of inverter-based resources (IBR) using currents (phase or sequence). Further studies using electromagnetic transient (EMT) simulation show that the initial operating conditions of the IBRs influence the response of phase currents during an SLG fault. In this letter, we conduct a quantitative analysis using sequence components. We find that the pre-fault condition determines the relative position of the current contributed by the grid versus that from the IBR, and further dictates which phase has the largest magnitude during an SLG condition. Finally, this finding is further verified by the EMT simulation results.

electromagnetic transient simulation↗

Television broadcast relay system, volume 2

A statistical analysis of propagation characteristics at 12 GHz for the design of a worldwide communication satellite system is reported. High power spaceborne TV transmitter design and the development of a low cost, low noise ground receiver for domestic reception are considered most important for implementation of a TVBS system.

Graf, E. R.↗

Multipath study for a low altitude satellite utilizing a data relay satellite system

Technical considerations associated with a low altitude satellite operating in conjuction with a data relay satellite system are reported. Emphasis was placed on the quantitative characterization of multipath phenomenon and determination of power received via both the direct and earth reflection paths. Attempts were made to develop a means for estimating the magnitude and nature of the reflected power.

Eggert, D.↗

The Relay spacecraft

Structure, power, communications, telemetry, tracking, and command for Relay I spacecraft

COMMAND SYSTEM↗

Solid state power controllers

Solid state power controllers (SSPC's) are to be considered for use as replacements of electromechanical relays and circuit breakers in future spacecraft and aircraft. They satisfy the combined function of both the relay and circuit breaker and can be remotely controlled by small signals, typically 10 mA, 5 to 28 v(dc). They have the advantage over conventional relay/circuit breaker systems in that they can be located near the utilization equipment and the primary ac or dc bus. The low level control, trip indication and status signals can be circuited by small gauge wire for control, computer interface, logic, electrical multiplexing, onboard testing, power management, and distribution purposes. This results in increased system versatility at appreciable weight saving and increased reliability. Conventional systems require the heavy gage load wiring and the control wiring to be routed from the bus to the load to other remote relay contacts, switches, sensors, etc. and to the circuit breaker located in the flight engineer's compartment for purposes of manual reset.

Gibbs, R. S.↗

High-power dual-directional coupler

Water-cooled coupler installed in S-band polarization diversity (SPD) cone is used to calibrate receiving-station relay. Coupler operates without arcing at 400 kw and permits accurate calibration of entire system below antenna feed horn. Device has good directivity, contributes less than 0.01 K to system noise temperature, and eliminates saturation of ground station and spacecraft receivers during high-power operation.

Otoshi, T. Y.↗

Post-Event Fault Identification with Machine Learning for Protection System Validation

Power system protection devices have transitioned over the past few decades from mechanical to analog devices, then to solid state and finally digital. Relays and their associated critical network of equipment have significantly increased in complexity. Even internally, relays have gained significant intricacy, with relatively simple overcurrent or differential functions now being assisted by a myriad of other functions. This is necessary as the grid becomes more complex, but it brings increased difficulty in monitoring and upkeep. Misoperation caused by accidental improper relay settings or deliberate malicious actions is a constant challenge faced by all utilities. These improper settings can be difficult to identify and may require exhaustive post-mortem analysis, typically after a major outage event has already occurred. A mechanism is needed for monitoring the behavior of protection systems to validate that their performance falls within expectations. Relays that fail to isolate a fault or trip when there is no system disturbance can be flagged for settings review in situations where this behavior may not have been noticed due to manual restoration or backup protection operations. This work presents a concept for a machine learning (ML) system capable of validating the performance of protection systems by identifying fault events and characterizing protection system responses based solely on available current and voltage measurements. As a first step in its development, an experimental dataset is generated, and a random forest model is implemented with high accuracy in distinguishing four power system scenarios.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Low-Voltage Protection For Volatile Computer Memories

Short-circuit current provides minimum memory power. Protective circuit includes dc-to-dc converter that supplies keep-alive voltage to memories when short circuit occurs in any of system loads. Converter powered by lowvoltage across two of three series diodes generated by short-circuit bus current. Relay switch is in open (short-circuit-detected) position. Protective circuit useful wherever necessary to improve reliability of volatile memories or other circuits that must not lose power.

Detwiler, R. C.↗

Modeling of dynamic effects of a low power laser beam

Methods of modeling some of the dynamic effects involved in laser beam propagation through the atmosphere are addressed with emphasis on the development of simple but accurate models which are readily implemented in a physical optics code. A space relay system with a ground based laser facility is considered as an example. The modeling of such characteristic phenomena as laser output distribution, flat and curved mirrors, diffraction propagation, atmospheric effects (aberration and wind shear), adaptive mirrors, jitter, and time integration of power on target, is discussed.

Lawrence, George N.↗

Protection System Validation Using Post-Event Anomaly Classification with Machine Learning

Power system protection devices have transitioned over the past few decades from mechanical to analog devices, then to solid state and finally digital. Relays and their associated critical network of equipment have significantly increased in complexity. Even internally, relays have gained significant intricacy, with relatively simple overcurrent or differential functions now being assisted by a myriad of other functions. This is necessary as the grid becomes more complex, but it brings increased difficulty in monitoring and upkeep. Misoperation caused by improper relay settings or malicious actions is a constant challenge faced by all utilities. These improper settings can be difficult to identify and may require exhaustive post-mortem analysis, typically after a major outage event has already occurred. A mechanism is needed for monitoring the behavior of protection systems to validate that they act and perform as expected. This work presents a concept for a machine learning (ML) system capable of validating the performance of protection systems by classifying anomalous events and characterizing protection system responses based solely on available current and voltage measurements. As a first step in its development, an experimental dataset is generated, and a random forest model is implemented with high accuracy in distinguishing four power system scenarios.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Protection System Validation with Machine Learning Anomaly Classification

A poster for the Early Career Poster Session. Power system protection devices have transitioned over the past few decades from mechanical to analog devices, then to solid state and finally digital. Relays and their associated critical network of equipment have significantly increased in complexity. Even internally, relays have gained significant intricacy, with relatively simple overcurrent or differential functions now being assisted by a myriad of other functions. This is necessary as the grid becomes more complex, but it brings increased difficulty in monitoring and upkeep. Misoperation caused by improper relay settings or malicious actions is a constant challenge faced by all utilities. These improper settings can be difficult to identify and may require exhaustive post-mortem analysis, typically after a major outage event has already occurred. A mechanism is needed for monitoring the behavior of protection systems to validate that they act and perform as expected. This work presents a concept for a machine learning (ML) system capable of validating the performance of protection systems by classifying anomalous events and characterizing protection system responses based solely on available current and voltage measurements. As a first step in its development, an experimental dataset is generated, and a random forest model is implemented with high accuracy in distinguishing four power system scenarios.

24 - POWER TRANSMISSION AND DISTRIBUTION↗