Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power system faults”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Distributed Ledger Technology for Fault Tolerant Distribution Grid Operations

This paper explores the potential of distributed ledger technology (DLT) to improve fault-tolerant grid operations by leveraging its core features as an immutable, decentralized ledger, a distributed, consensus-based agreement process, and a distributed state-replication engine. Distribution power systems deliver electricity to millions of customers; however, they are susceptible to various threats that can result in customer interruptions. These include faults caused by adverse weather conditions, natural disasters, vegetation growth, equipment failure, and malicious attacks. To minimize the effects of these faults, fault-handling approaches rely on network knowledge to isolate affected areas and reconnect unaffected areas, reducing the number of affected customers while maintaining safety. Here, we present a trusted data-sharing architecture that enables independent, distributed actors to reconstruct the pre-fault system state by enabling distributed resources to make appropriate decisions with limited network/system information. Although the process requires some data sharing between switch-delimited areas, the approach limits the amount of private information shared, preserving customers' privacy and business-sensitive information. We include three use cases that form a foundation for third parties to develop functional solutions that can eventually be deployed in the field. The gross error detection method used within switch-delimited areas can identify sensor errors and accurately detect circuit breaker states. The evaluation of possible reconnection while preserving data ownership resulted in a voltage magnitude difference smaller than 0.001% from the OpenDSS power flow solution that has full system knowledge, which is below the expected power flow tolerance. The approach offers a promising opportunity for improving fault-tolerant distribution grid operations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Simulation and power quality analysis of a Loose-Coupled bipolar DC microgrid in an office building

With distributed generation and battery storage technologies thriving in microgrids, the use of direct current (DC) microgrids in the building sector offers multiple advantages in energy efficiency and power quality compared with alternating current (AC) systems. This study developed a new concept of a loose-coupled bipolar DC building power system. In this work, the concept was used to design a real-world office building in Shenzhen, China. A power system model was developed to study the stability and control of the DC power system and to verify DC power quality. The design and modeling of the DC power control system is discussed in detail. The study developed a few common fault scenarios in DC building microgrids that were simulated in the MATLAB-Simulink environment to validate the design of a loose-coupled bipolar DC system. The results indicate that the proposed loose-coupled bipolar DC system schema, when implemented with proper control algorithms, can achieve good fault-tolerant performance with reliable power quality, even during disruptive system events.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

WBG-Enabled Current-Source Inverters for Integrated PM Motor Drives

This project takes advantage of the special capabilities of wide-bandgap (WBG) power semiconductor devices to develop innovative power electronics in the form of new current-source inverters (CSIs) that offer promising advantages over the dominant voltage-source inverter (VSI) topology. These CSIs, in turn, are extremely well-suited for integration into the housings of permanent magnet synchronous machines (PMSMs) to form integrated motor drives (IMDs). These new IMDs offer great promise for achieving major energy savings in a wide variety of applications that benefit from adjustable-speed control, including air conditioners, laundry appliances, industrial pumps/compressors, electric vehicles, and aerospace drives. WBG devices play a critical enabling role in these new IMDs because of their transformative features including much higher switching frequencies, lower losses, and compatibility with high operating temperatures. When incorporated into new CSI-based IMDs with PM machines, these WBG switches open the door to achieving major increases in power density, drive system efficiency, and fault tolerance, as well as substantial reductions in electromagnetic interference (EMI), manufacturing cost, and temperature-induced failures. The higher operating temperature capability of WBG devices compared to conventional silicon power devices is very appealing in IMD applications because the power electronics is mounted in close proximity to the motors which typically operate at temperatures well above the maximum limits of today’s silicon-based power electronics. This project has succeeded in designing, building, and testing multiple prototype versions of this CSI-IMD that have overcome many technical challenges in order to demonstrate the impressive performance improvements that can be achieved by the WBG-enabled CSI-IMD. The preliminary demo and bench-top versions of the current-source inverter developed during the first two years of the project were critical to laying the technical foundations for the 3 kW prototype CSI-IMD unit that was successfully built and tested during the third year. This prototype CSI-IMD unit was designed to fit within the housing envelope of the original permanent magnet (PM) synchronous machine in order to meet the demanding power density requirements that were set at the beginning of the project. All of the remaining performance objectives set for the prototype CSI-IMD unit including efficiency and electromagnetic interference (EMI) were also met. The last 18 months of the project were devoted to developing further enhancements of the WBG-enabled CSI-IMD technology that better prepare it for commercial production. More specifically, an upgraded version of the prototype CSI-IMD unit was developed that moved the power electronics into the same machine housing chamber as the motor, substantially raising the thermal demands on the power electronics. Tests with five different combinations of motor enclosure types and air cooling configurations were evaluated. Importantly, this work confirmed that the power electronics can deliver its full rated power and still operate well within its maximum temperature limits even for worst-case conditions when the housing is “totally-enclosed” without any openings for air to enter or exit the enclosure, and no blower/fan is provided to blow air over the outside surface of the enclosure. Reaching the full performance and energy-savings potential of this disruptive CSI-IMD motor drive technology is highly consistent with ARPA-E’s stated mission to “enhance the economic and energy security of the United States” while also supporting its commitment to “ensure that the U.S. maintains a technological lead in developing and deploying advanced energy technologies”. Follow-on projects are under way to explore the scalability of WBG-enabled CSI-IMD technology to 100 kW (peak) electric vehicle traction drives and fault-tolerant modular motor drives for future electrified aircraft propulsion applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advanced Sensor Deployment for Distribution System State Estimation and Fault Identification

Distribution systems are currently facing steep operational challenges as a result of the rapidly increasing integration of renewables and other distributed energy resources (DERs) at both the primary and secondary circuit levels. Distribution utilities and system operators have traditionally had some visibility of their primary circuits using low-frequency supervisory control and data acquisition systems, and they have had very poor if not zero visibility of the secondary circuits where the presence of DERs is constantly increasing. Therefore, this paper presents simulation studies to demonstrate the benefits of an advanced, high-fidelity sensor technology, called as the Meta-Alert System (MAS), developed by Electrical Grid Monitoring, Ltd. (EGM), on the distribution grid. First, a reliable model of the EGM sensors is developed, and then two use cases, distribution system state estimation (DSSE) and fault identification are simulated to evaluate the performance of the MAS technology. Simulation results on the Electric Power Research Institute J1 feeder demonstrate that the MAS can effectively participate in system-level DSSE programs and can detect and locate faults faster than traditional distribution protection schemes.

distribution system↗

Post-Event Fault Identification with Machine Learning for Protection System Validation

Power system protection devices have transitioned over the past few decades from mechanical to analog devices, then to solid state and finally digital. Relays and their associated critical network of equipment have significantly increased in complexity. Even internally, relays have gained significant intricacy, with relatively simple overcurrent or differential functions now being assisted by a myriad of other functions. This is necessary as the grid becomes more complex, but it brings increased difficulty in monitoring and upkeep. Misoperation caused by accidental improper relay settings or deliberate malicious actions is a constant challenge faced by all utilities. These improper settings can be difficult to identify and may require exhaustive post-mortem analysis, typically after a major outage event has already occurred. A mechanism is needed for monitoring the behavior of protection systems to validate that their performance falls within expectations. Relays that fail to isolate a fault or trip when there is no system disturbance can be flagged for settings review in situations where this behavior may not have been noticed due to manual restoration or backup protection operations. This work presents a concept for a machine learning (ML) system capable of validating the performance of protection systems by identifying fault events and characterizing protection system responses based solely on available current and voltage measurements. As a first step in its development, an experimental dataset is generated, and a random forest model is implemented with high accuracy in distinguishing four power system scenarios.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Simulating Distributed Energy Resource Responses to Transmission System-Level Faults Considering IEEE 1547 Performance Categories on Three Major WECC Transmission Paths

This study performs a large quantity of transmission and distribution simulations for three regions in the Western Interconnection along with final transmission simulations informed by distribution simulation results. Results find that the type of ride-through implemented by distributed energy resources (DERs) is a significant factor to the overall power system response to transmission-level faults. This impact is particularly high for transmission-level faults that depress voltage levels for high numbers of substations (i.e., for cases that experience large regional voltage sags). Because of the programmed nature of the ride-through of IEEE 1547-compliant DERs, the potential for large reductions in real power injection is possible based on IEEE 1547 interpretation and specific implementation. In this study, we made a first attempt to determine the quantity of DERs affected by a variety of transmission-level faults as well as a granular response of distribution-simulated DERs to a few types of IEEE 1547-2003 interpretations and IEEE 1547-2018 voltage ride-through categories. The distribution-informed transmission studies show that the category of IEEE 1547 adherence, particularly with the new 2018 standard, can have a significant impact on the amount of DER-based generation lost following transmission-level fault events.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Explaining System-Level Prognostics with Established Machine Learning Methods

System-level prognostics is crucial for ensuring reliability and enabling predictive maintenance in complex systems with interconnected components. This study presents a framework that integrates data-driven methods to predict the remaining useful life (RUL) of a subsystem under multiple and concurrent faults within a nuclear power plant system with explainable artificial intelligence (XAI). A nuclear power plant (NPP) operation was simulated to model the degradation behavior of NPP components, and four machine learning models—Gradient Boosting Regressor (GBR), Support Vector Regressor (SVR), Fully Connected Neural Network (FCNN), and Long Short-Term Memory (LSTM)—were evaluated for prognostics with a novel system RUL parameter. The LSTM model demonstrated potential superior repeatability, while SHAP (SHapley Additive exPlanations) for explainability provided consistent and trustworthy global explanations. In contrast, LIME (Local Interpretable Model-agnostic Explanations) offered localized interpretability but showed reduced stability for sequential data. Key findings include the interplay between component-level degradation and system-wide performance, with LSTM effectively capturing these dynamics through sequence-level predictions. The XAI techniques enhanced transparency by identifying critical features influencing model predictions and aligning with domain knowledge. Furthermore, this framework has significant implications for improving trust and understanding in predictive maintenance, particularly in safety-critical industries like nuclear energy.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Blockchain for Fault-Tolerant Grid Operations

Distribution system fault/failure has a direct impact on customers. Distribution systems are not designed with the contingency of one or more elements failing as the transmission system, however, distribution systems are more likely to have faults in comparison to transmission and generation systems. Most of the distribution systems have a radial design with the protection system assumption of unidirectional power flow. The radial design results in the disconnection of customers for any given component failure. The rapid deployment of distributed energy resources conflicts with the assumption of unidirectional power flow. To maintain/improve the distribution system fault tolerance for a grid with high penetration of distributed energy resources requires improvement. Blockchain can add value to improve fault-tolerant grid operations. That can be achieved using blockchain’s core features of distributed consensus-based decision-making process and immutability. In the process of preparing for an event or system restoration, there is a need for reliable data and system situational awareness. The system situational awareness enables accurate planning for possible scenarios and system restoration after an event, an area where blockchain’s distributed architecture can help. The value of blockchain for a fault-tolerant grid operation is elaborated with three use cases: 1) fault location, isolation, and service restoration; 2) topology identification; and 3) data configuration. These use cases demonstrate how blockchain-based architecture can facilitate bridging the vulnerabilities of the existing implementation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electrical substation grid testbed for DLT applications of electrical fault detection, power quality monitoring, DERs use cases and cyber-events

Electrical utilities continue to deploy more intelligent electronic devices (IEDs) inside and outside electrical substation, and are associated with customer-owned distributed energy resources (DERs). The integrity and confidentiality of data from these IEDs, like power meters and protective relays, is crucial. Blockchain technology could improve the resilience of microgrids by improving the security of data sharing. The penetration of customer-owned DERs (renewable energy sources) and the increasing deployment of IEDs can lead to integrate power system applications with Distributed Ledger Technology (DLT). In this study, we implemented the electrical faulted phase detection and power quality monitoring algorithms with a Cyber Grid Guard (CGG) system using DLT. In addition, the DERs (wind turbine farms) use case and protective relay cyber-event tests were assessed, by using the CGG system with DLT. In the experimental model, the testbed was created by using a real-time simulator and CGG system with power meters/ protective relays in-the-loop. The data collected from the CGG system and IEDs were compared with the same time stamp source. These results had shown the successful assessment of protection, control and monitoring applications using a CGG system with DLT. In the future, the ESGT with DERs and the CGG system will be used in other power system applications, based on implementing smart contracts between electrical utilities with customer-owned DERs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A physics-based parametric regression approach for feedwater pump system diagnosis

Here in this paper, we assessed the performance of a model-based approach for fault diagnosis of a nuclear power plant feedwater pump system. Physics-based models were constructed to monitor the performance of the system components. Plant data were used for the calibration of the models and subsequently in the diagnosis of abnormal events. We considered two real-time events representing scenarios of a pump fault and component performance degradation. The two events were correctly diagnosed, and the results demonstrated the high detection sensitivity of the physics-based models. Various sensor fault scenarios were simulated to show the capability of the approach to detect and uniquely identify sensor faults. Results for a scenario in which the plant operated in flexible power mode also showed that the diagnostic approach is insensitive to changes of operating conditions, which is one of the advantages of the model-based approach using physics-based models over purely data-driven approach.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Live State of Health Monitoring of Inverter Subsystems

This presentation talks about different failure modes and corresponding detection schemes of PV panels, PV inverters, electric machines such as motors and power converter. Several novel techniques have been presented that are capable of measuring degradation as well as detecting faults in various location in a PV based power system.

ENGINEERING,SOLAR ENERGY↗

Control, Fault Management, and Grid Support Functionality of an MV AC-DC Solid State Transformer based EV Extreme Fast Charging Station

Electric vehicles (EVs) have become increasingly popular in recent times while revolutionizing the consumer and commercial transportation market. The development of charging infrastructure has become one of the priorities for increasing the adoption of EVs. Extreme fast charging (XFC) technology can reduce the so-called ’range anxiety’ of consumers as they significantly reduce the charging time. With the advent of wide band-gap (WBG) power devices and improvement in power electronic converters, medium voltage (MV) solid state transformer (SST) based XFC system has the potential to replace the traditional XFC stations because of the lower footprint, ease of installation, enhanced control feature, and better system efficiency. The control system design is one of the critical aspects of the SST development process. Careful consideration and detailed analysis are required to find out suitable control method for the SST based on its topology among different centralized and decentralized control architectures. Also, the control parameters selection and potential improvement to the transient response of the controller ought to be investigated. Another major concern of the SST is different types of internal fault which reduces the overall reliability of the XFC system. As a result, designing a robust protection system is essential. Among different fault modes, open circuit switch faults have received significant attention as an active research area because of their likelihood and severe effects on converters. Therefore, the power stages used in the XFC system require functional and accurate open circuit switch fault management methods. An equally significant aspect of this SST based XFC is its compatibility in a microgrid where there is no synchronous generator present. When the grid is not available, the XFC SSTs can provide grid forming capability and continue supplying the critical loads in islanded mode. The transition between grid connected and islanded mode, especially the grid resynchronization process has to be carefully performed for the safety of the microgrid components. The challenges posed by the aforementioned issues have inspired the work done in this dissertation. Here, a 13.2 kV, 1 MVA, AC/DC SST for the XFC system is examined and a comparative analysis is conducted to select the control architecture based on feasibility of implementation and performance. A detailed control parameter design process is demonstrated considering the sensor dynamics and delay. The selected decentralized control method is augmented by introducing a novel sensor-less load current feedforward method to provide better voltage regulation at the DC bus during a change of load. Next, in the fault management section, a hierarchical failure mode effect analysis (FMEA) is proposed to enable a systematic design of the internal fault protection of the XFC SST as there are limited examples in the literature regarding the analysis of the safety and design of the protection of a power electronic converter system. Novel open circuit switch fault management methods for the converters in the system are presented. Finally, XFC SST based MV microgrid operations in grid connected mode and islanded mode are explored. A secondary control method for grid resynchronization is presented and a design process of control parameters is shown to ensure the stability of the secondary voltage and frequency regulation.

30 DIRECT ENERGY CONVERSION↗

Protection settings optimizer

SAND2023-06672O The Protection Settings Optimizer (PSO) uses system and fault data as inputs to formulate the problem of calculating relay settings as a mixed integer, nonlinear optimization problem (MINLP). The MINLP is solved using a genetic algorithm-based optimizer that attempts to find settings to reduce the relay operating times. The PSO protects the power system by using the steady-state fault voltages and currents, which then calculates the optimal device setting to protect the power system. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Patel, Trupal↗

Spread Spectrum Time Domain Reflectivity for String Monitoring in PV Power Plants (Final Technical Report)

This final report describes the methods and results of applying Spread Spectrum Time Domain Reflectivity (SSTDR) for String Monitoring in PV Power Plants for DE-EE0008169. The project created a new system for both detecting and locating electrical faults in photovoltaic systems. In this work, we address photovoltaic electric faults that are both common and costly. Based on interviews with photovoltaic power plant owners, operators, and maintainers, three types of faults are common and of significant interest: disconnects, ground faults, and arc faults. Disconnects can originate from many sources. They are often due to everyday events, such as lawnmowing (accidentally running over a cable), animals eating through the cables, or degradation that occurs over time due to corrosion or general degradation. Ground faults occur when the cables (for example, due to frayed insolation) connect to the ground, relaying current into the ground. These faults are particularly problematic since the ground faults are often intermittent. That is, ground faults commonly appear during rain storms due to a change in soil conductivity and then disappear when the rain ends. This makes the ground fault difficult to find because while current systems can detect the overall change in voltage and current associated with a ground fault, technicians are necessary to locate the fault. As a result, ground faults may disappear before the technician arrives at the power plant. Hence, locating and fixing ground faults often require multiple trips. We also study arc faults, which can result when nearby conductors create an arc of electrical current through the air. While less common, arc faults can be extremely dangerous. The energetic electrical arc can cause fires and destroy equipment, costing significant damage. Overall all three types of faults cost owners and operators money, either from the destruction of equipment or from technician time. Furthermore, while devices exist for detecting ground faults (ground fault circuit interrupters) and arc faults (arc fault circuit interrupter), these systems only search patterns of electrical current that correspond to each fault. This information cannot be used to locate the fault. In addition, these protection systems experience nuisance trips due to nearby electromagnetic interference, such as from a lawn mower or other motors that produce significant amounts of electromagnetic radiation. Hence, the overall goal of this project is to create an SSTDR tool that provides photovoltaic power plants with more reliable fault detection in addition to the localization of faults. SSTDR works by transmitting electrical signals into the photovoltaic string. Those signals reflect from impedance discontinuities (i.e., disconnects, ground faults, and arc faults). These faults are then detected by measuring the presence of a reflection at the SSTDR and can be located by identifying the location of that reflection in time. In addition, unlike current protection systems, these systems do not experience nuisance trips since their low amplitude, high frequency, and coded signal can by analyzed without interference from the regular operational voltage on the photovoltaic string.

14 SOLAR ENERGY↗

Model Agnostic Bayesian Framework for Online Anomaly/Event Detection in PMU Data

Phasor measurement units (PMU) are integral to the modernization and automation plan of the electric power industry. A PMU data signature contains system-level events (e.g., faults, generation/load change, etc.) and any measurement/device-related errors. Therefore, the reliable and resilient operation of power systems is equivalent to the quality of the PMU data and the situation awareness provided by its data signature. Despite recent progress, current state-of-the-art methods are not fool-proof and have certain limitations tracing an error/abnormality to sensor sub-components and grid systems. This is because of technical challenges imposed by the scarcity of the labeled information, loss of data quality, and non-stationarity of data. In this paper, we consider the online PMU data stream as an output of a stochastic process and pose the anomaly/event detection as a changepoint detection problem dealing with detecting parameter changes in the underlying stochastic processes. The proposed model-agnostic framework relies on: (a) feature extraction utilizing the minimum volume enclosing ellipsoids (MVEE) method from raw PMU observations and (b) a Bayesian framework of changepoint detection. The validity of the proposed methodology is discussed through numerical experiments on real-world utility-scale PMU data.

Hossain, Ramij Raja↗

Influence of Inverter-Based Resources on Microgrid Protection: Part 1: Microgrids in Radial Distribution Systems

Microgrids are being deployed at a rising rate, primarily as a means of increasing power system resilience. Commonly, a microgrid today includes at least some inverter-based resources (IBRs), and many microgrids have modes or conditions under which they are entirely energized by IBRs. Also, most microgrids today are deployed on radial distribution circuits, but it is conceivable that they could also be considered for deployment on secondary network systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Power Electronics Based Self-Monitoring and Diagnosing for Photovoltaic Systems

Faults in photovoltaic (PV) systems can seriously affect the efficiency, energy yield, cost, safety, and reliability of PV plants. Condition monitoring of PV plants is, therefore, a very important approach to estimating the health condition of PV modules and power electronics in the system. However, additional hardware for PV system monitoring adds cost to the system's operation; delayed maintenance service also causes additional energy production loss. The Center for Power Electronics Systems (CPES) at the Virginia Polytechnic Institute and State University and Siemens Cooperate Research developed the online impedance measurement for a PV panel self-monitoring and diagnosing technology using the DC-DC converter connected to the panel. Small-signal impedances of a monocrystalline silicon PV panel were modeled and simulated to reflect fault conditions such as the short-circuit, hot-spot, and junction box faults. Modeling and simulation results were validated firstly using a test setup consisting of a solar simulator, a network analyzer, small-signal injectors, and a monocrystalline PV panel rated at 300 W.

14 SOLAR ENERGY↗

Inter-Area Oscillation Damping with Type-5 Wind Power Plant: Preprint

This paper investigates the potential of using brushless excitation (BLE) for not only riding through the fault but also to damp inter-area power oscillation with the help of a synchronous generator (SG) used in Type 5 Wind Power Plant (WPP). In BLE, an auxiliary synchronous generator (ASG) behaving like an exciter is coupled and driven by the rotor of the main SG. The BLE's field current's ASG is fed by two separate loops of the automatic voltage regulator (AVR) and Power System Stabilizer (PSS). The AVR system implements a control loop to regulate the generator terminal voltage, VT. For the PSS, the kinetic energy of the wind turbine is utilized according to the estimated rotational speed of the synchronous generator shaft of the SG. It mitigates the necessity of any curtailment of active power for damping. The effectiveness of the proposed control scheme is verified with a three-phase short circuit fault in a two-area power system.

brushless↗