Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power pc”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Laser-heated capillary discharge plasma waveguides for electron acceleration to 8 GeV

A plasma channel created by the combination of a capillary discharge and inverse Bremsstrahlung laser heating enabled the generation of electron bunches with energy up to 7.8 GeV in a laser-driven plasma accelerator. The capillary discharge created an initial plasma channel and was used to tune the plasma temperature, which optimized laser heating. Although optimized colder initial plasma temperatures reduced the ionization degree, subsequent ionization from the heater pulse created a fully ionized plasma on-axis. The heater pulse duration was chosen to be longer than the hydrodynamic timescale of ≈ 1 ns, such that later temporal slices were more efficiently guided by the channel created by the front of the pulse. Here, simulations are presented which show that this thermal self-guiding of the heater pulse enabled channel formation over 20 cm. The post-heated channel had lower on-axis density and increased focusing strength compared to relying on the discharge alone, which allowed for guiding of relativistically intense laser pulses with a peak power of 0.85 PW and wakefield acceleration over 15 diffraction lengths. Electrons were injected into the wake in multiple buckets and times, leading to several electron bunches with different peak energies. To create single electron bunches with low energy spread, experiments using localized ionization injection inside a capillary discharge waveguide were performed. A single injected bunch with energy 1.6 GeV, charge 38 pC, divergence 1 mrad, and relative energy spread below 2% full-width half-maximum was produced in a 3.3 cm-long capillary discharge waveguide. This development shows promise for mitigation of energy spread and future high efficiency staged acceleration experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Real-time sensor measurements to evaluate impacts of load cycling on high-temperature fire-side corrosion in a PC boiler

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. This project leveraged the existing electrochemical noise-based monitoring system and the new sensor design is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data is transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, the three mMPMS were installed at a full-scale pulverized coal-fired plant, PacifiCorp’s Hunter 3. The systems were demonstrated over 20,000 hours at the plant during regular operation. Also, the sensor data was fed to the plant’s advanced process control system to evaluate the corrosion control by the operation changes and utilized to understand the impacts of load cycling with different ramping up and down speeds. At the end of the project, the systems were converted to the permanent installation at the power plant to be used with the advanced process control system installed at the plant.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

High-Temperature Multi-Process Sensor Development for a PC-Fired Unit

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. This project leveraged the existing electrochemical noise-based monitoring system and the new sensor design is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data is transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, the three mMPMS were installed at a full-scale pulverized coal-fired plant, PacifiCorp’s Hunter 3. The systems were demonstrated over 20,000 hours at the plant during regular operation. Also, the sensor data was fed to the plant’s advanced process control system to evaluate the corrosion control by the operation changes and utilized to understand the impacts of load cycling with different ramping up and down speeds. At the end of the project, the systems were converted to the permanent installation at the power plant to be used with the advanced process control system installed at the plant.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

Full-scale Demonstration of Multi-process Sensor at a Cycling PC-fired Boiler

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. This project leveraged the existing electrochemical noise-based monitoring system and the new sensor design is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data is transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, the three mMPMS were installed at a full-scale pulverized coal-fired plant, PacifiCorp’s Hunter 3. The systems were demonstrated over 20,000 hours at the plant during regular operation. Also, the sensor data was fed to the plant’s advanced process control system to evaluate the corrosion control by the operation changes and utilized to understand the impacts of load cycling with different ramping up and down speeds. At the end of the project, the systems were converted to the permanent installation at the power plant to be used with the advanced process control system installed at the plant.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

High-Temperature Multi-Process Sensor Development and Demonstration at a Full-scale PC Combustion System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. This project leveraged the existing electrochemical noise-based monitoring system and the new sensor design is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data is transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, the three mMPMS were installed at a full-scale pulverized coal-fired plant, PacifiCorp’s Hunter 3. The systems were demonstrated over 20,000 hours at the plant during regular operation. Also, the sensor data was fed to the plant’s advanced process control system to evaluate the corrosion control by the operation changes and utilized to understand the impacts of load cycling with different ramping up and down speeds. At the end of the project, the systems were converted to the permanent installation at the power plant to be used with the advanced process control system installed at the plant.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

Substation Secondary Asset Health Monitoring and Management System (SSHM)

Electric Power Group, LLC (EPG) was awarded DOE OE0000850 to design, develop, and demonstrate a real-time software application for substation secondary equipment health monitoring and management at host utility American Electric Power (AEP), a cost share partner. This project addresses the need for monitoring substation equipment health and providing operators with tools to identify and take pre-emptive action to avoid catastrophic equipment failure. By monitoring synchrophasor data in real time, data anomalies that indicate potential asset failure can be detected and alerts can be sent to operators in time to take corrective actions. EPG developed two data driven algorithms to identify abnormal equipment signature patterns as well as a method using substation linear state estimation (SLSE). The software has been deployed on hardened PC’s and tested and validated for cost share partner AEP’s substations - 138kV and 765 kV. The SSHM software has been accepted by AEP and final demonstration of DOE - OE0000850 for AEP and DOE was successfully completed on March 17th, 2020. EPG developed the Substation Secondary Asset Health Monitoring (SSHM) Platform to analyze equipment failure signatures in PMU data and alert substation personnel when pre-emptive inspection, repairs and other actions are warranted to prevent potential catastrophic failures. This is the first system that automatically monitors the health of substation secondary assets and alerts users to emerging failures using synchrophasor measurements. SSHM uses high resolution PMU data from PTs, CTs, and CCVTs to analyze equipment signatures and identify anomalies that are precursor indicators of potential equipment failure. When an anomaly is detected, there is a likelihood of potential failure of monitored equipment, the system alerts the user with visual alarms including alarm trend charts and indicator lights on a oneline diagram of the substation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Discovery of a Nearby Young Brown Dwarf Disk

We report the discovery of the youngest brown dwarf with a disk at 102 pc from the Sun, WISEA J120037.79−784508.3 (W1200−7845), via the Disk Detective citizen science project. We establish that W1200−7845 is located in the 3.7{sub −1.4}{sup +4.6} Myr old ε Cha association. Its spectral energy distribution (SED) exhibits clear evidence of an infrared (IR) excess, indicative of the presence of a warm circumstellar disk. Modeling this warm disk, we find the data are best fit using a power-law description with a slope α = −0.94, which suggests that it is a young, Class II type disk. Using a single blackbody disk fit, we find T{sub eff,disk}=521 K and L{sub IR}/L{sub ∗}=0.14. The near-IR spectrum of W1200−7845 matches a spectral type of M6.0 γ ± 0.5, which corresponds to a low surface gravity object, and lacks distinctive signatures of strong Paβ or Brγ accretion. Both our SED fitting and spectral analysis indicate that the source is cool (T {sub eff} = 2784–2850 K), with a mass of 42–58 M {sub Jup}, well within the brown dwarf regime. The proximity of this young brown dwarf disk makes the system an ideal benchmark for investigating the formation and early evolution of brown dwarfs.

79 ASTRONOMY AND ASTROPHYSICS↗

High-Temperature Multi-Process Sensor Development and Demonstration at a Full-scale PC Combustion System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution of wall conditions in utility boilers. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of a coal-fired utility boiler in this project but can be applied to many other industries and applications as well. The new sensor design, leveraging the existing electrochemical noise-based monitoring system, is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data can be transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, five mMPMS were installed at a full-scale pulverized coal-fired plant, Basin Electric Power Cooperative’s Leland Olds Unit 1. The systems were demonstrated over a 6-week period during typical operation. Sensor measurements of deposit thickness were validated during the demonstration and subsequently leveraged to determine sensor-based boiler cleaning strategies. These strategies have the benefit of reduced thermal stresses on boiler tubes from over-cleaning and improved boiler water management. At the end of the project, continued development of the sensor technology was carried out at PacifiCorp’s Hunter Station. REI leveraged the permanent installation of the mMPMS in Unit 3 made possible by DOE funding on a separate program. The work at Hunter Plant focused on application of machine learning and artificial intelligence-based models for integration of sensor signals into control and optimization of Hunter Unit 3 processes.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

A mechanistic study of mesoporous TiO 2 nanoparticle negative electrode materials with varying crystallinity for lithium ion batteries

Nanoscale oxide-based negative electrodes are of great interest for lithium ion batteries due to their high energy density, power density and enhanced safety. In this work, we conducted a case study on mesoporous TiO 2 nanoparticle negative electrodes with uniform size and varying crystallinity in order to investigate the trend in the electrochemical properties of oxide-based nanoscale negative electrodes with varying crystallinity. Furthermore, mesoporous solid spherical TiO 2 nanoparticles with a uniform particle size and varying crystallinity, i.e. , amorphous TiO 2 (A-TiO 2 ), partially crystalline TiO 2 (PC-TiO 2 ) and fully crystalline TiO 2 (FC-TiO 2 ) nanoparticles were studied. At low current rate (quasi steady-state), the specific capacity of the samples drops with the decrease of crystallinity. Ex situ synchrotron pair distribution function analysis reveals that the 1D zigzag Li ion diffusion pathway becomes expanded with the increase of crystallinity, which promotes ion mobility and charge storage. At high current rates (away from equilibrium states), however, the A-TiO 2 sample demonstrates slightly larger capacity than the FC-TiO 2 sample, both of which show larger capacities than that of the PC-TiO 2 sample. Both A-TiO 2 and FC-TiO 2 samples exhibit higher capacitive contribution to the charge storage and larger Li + diffusivity than those of the PC-TiO 2 sample, which explains their better rate capability. Moreover, the larger Li + diffusivity of the A-TiO 2 sample leads to the slightly larger specific capacity than the FC-TiO 2 sample at the highest current rate.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Unraveling the Photovoltaic, Mechanical, and Microstructural Properties and Their Correlations in Simple Poly(3‐pentylthiophene) Solar Cells

Abstract The power conversion efficiency of polythiophene organic solar cells is constantly refreshed. Despite the renewed device efficiency, very few efforts have been devoted to understanding how the type of electron acceptor alters the photovoltaic and mechanical properties of these low‐cost solar cells. Herein, the authors conduct a thorough investigation of photovoltaic and mechanical characteristics of a simple yet less‐explored polythiophene, namely poly(3‐pentylthiophene) (P3PT), in three different types of organic solar cells, where ZY‐4Cl, PC 71 BM, and N2200 are employed as three representative acceptors, respectively. Compared with the reference poly(3‐hexylthiophene) (P3HT)‐based solar cells, P3PT‐based devices, all perform more efficiently. Particularly, the P3PT:ZY‐4Cl blend exhibits the highest efficiency (ca. 10%) among the six combinations and outperforms the prior top‐performance system P3HT:ZY‐4Cl. Furthermore, the blend films based on N2200 exhibit a high crack‐onset strain of ∼38% on average, which is approximately 15‐ and 17‐times higher than those of ZY‐4Cl and PC 71 BM, respectively. The microstructural origins for the above difference are well elucidated by detailed grazing incidence X‐ray scattering and microscopy analysis. This work not only underlines the potential of P3PT in prolific solar cell research but also demonstrates the superior tensile properties of polythiophene‐based all‐polymer blends for the preparation of stretchable solar cells.

Polymer Science↗

Identifying RR Lyrae Variable Stars in Six Years of the Dark Energy Survey

We present a search for RR Lyrae stars using the full six-year data set from the Dark Energy Survey covering ∼5000 deg2 of the southern sky. Using a multistage multivariate classification and light-curve template-fitting scheme, we identify RR Lyrae candidates with a median of 35 observations per candidate. We detect 6971 RR Lyrae candidates out to ∼335 kpc, and we estimate that our sample is >70% complete at ∼150 kpc. We find excellent agreement with other wide-area RR Lyrae catalogs and RR Lyrae studies targeting the Magellanic Clouds and other Milky Way satellite galaxies. We fit the smooth stellar halo density profile using a broken-power-law model with fixed halo flattening (q = 0.7), and we find strong evidence for a break at with an inner slope of and an outer slope of . We use our catalog to perform a search for Milky Way satellite galaxies with large sizes and low luminosities. Using a set of simulated satellite galaxies, we find that our RR Lyrae-based search is more sensitive than those using resolved stellar populations in the regime of large (r h ≳ 500 pc), low-surface-brightness dwarf galaxies. A blind search for large, diffuse satellites yields three candidate substructures. The first can be confidently associated with the dwarf galaxy Eridanus II. The second has a distance and proper motion similar to the ultrafaint dwarf galaxy Tucana II but is separated by ∼5 deg. The third is close in projection to the globular cluster NGC 1851 but is ∼10 kpc more distant and appears to differ in proper motion.

79 ASTRONOMY AND ASTROPHYSICS↗

Low Temperature Aggregation Transitions in N3 and Y6 Acceptors Enable Double‐Annealing Method That Yields Hierarchical Morphology and Superior Efficiency in Nonfullerene Organic Solar Cells

Abstract Thermal transition of organic solar cells (OSCs) constituent materials are often insufficiently researched, resulting in trial‐and‐error rather than rational approaches to annealing strategies to improve domain purity to enhance the power conversion efficiency. Despite the potential utility, little is known about the thermal transitions of the modern high‐performance acceptors Y6 and N3. Here, by using an optical method, it is discovered that the acceptor N3 has a clear solid‐state aggregation transition at 82 °C. This unusually low transition not only explains prior optimization protocols, but the transition informs and enables a double‐annealing method that can fine‐tune aggregation and the device morphology. Compared with 16.6% efficiency for PM6:N3:PC 71 BM control devices, higher efficiency of 17.6% is obtained through the improved protocol. Morphology characterization with x‐ray scattering methods reveals the formation of a multilength scale morphology. Moreover, the double‐annealing method is illustrated and easily transferred and validated with Y6‐based devices, using the transition of Y6 at 102 °C. As a result, the PCE improved from 16.0% to 16.8%. Design of high‐performance acceptors with yet lower aggregation transitions might be required for OSCs to successfully transition to low thermal budget industrial processing methods where annealing temperatures on plastic substrates have to be kept low.

Qin, Yunpeng↗

Surfactant Engineering and Its Role in Determining the Performance of Nanoparticulate Organic Photovoltaic Devices

The fabrication of organic photovoltaics (OPVs) from non-hazardous nanoparticulate (NP) inks offers considerable promise for the development of ecofriendly large-scale printed solar modules. However, the typical NP core-shell morphology (driven by the different donor/acceptor affinities for the surfactant used in NP synthesis) currently hinders the photovoltaic performance. As such, surfactant engineering offers an elegant approach to synthesizing a more optimal intermixed NP morphology and hence an improved photovoltaic performance. In this work, the morphology of conventional sodium dodecyl sulfate (SDS) and 2-(3-thienyl) ethyloxybutylsulfonate (TEBS)-stabilized poly(3-hexylthiophene) (P3HT) donor:phenyl-C 61 -butyric acid methyl ester (PC 61 BM) acceptor NPs is probed using scanning transmission X-ray microscopy, UV-vis spectroscopy, grazing-incidence X-ray diffraction, and scanning electron microscopy. While the SDS-stabilized NPs exhibit a size-independent core-shell morphology, this work reveals that TEBS-stabilized NPs deliver an intermixed morphology, the extent of which depends on the particle size. Consequently, by optimizing the TEBS-stabilized NP size and distribution, NP-OPV devices with a power conversion efficiency that is ~50% higher on average than that of the corresponding SDS-based NP-OPV devices are produced.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Toward Emittance Measurements at 11.7 GHz Short-Pulse High-Gradient RF Gun

A short pulse high gradient RF gun has been recently tested at Argonne Wakefield Accelerator (AWA) facility. The carried-out test showed that the 1,5-cell gun was able to inject 3 MeV, up to 100 pC bunches at room tem-perature being fed by 9 ns up to 300 MW 11.7 GHz puls-es. The cathode field was as high as about 400 MV/m. So high field is aimed to mitigate repealing Coulomb forces substantially. In accordance with simulations the emit-tance could be as low as less than 0.2 mcm. To obtain so low emittance in the experiment, the gun is assumed to be equipped with a downstream linac to be fed from the same power extractor as the gun itself. Here we report design of the RF power distribution system splitting RF power among the gun and the linac, results of low-power tests, and emittance measurement plans for upcoming new experiment at AWA.

43 PARTICLE ACCELERATORS↗

Multiple Functional Bonds Integrated Interphases for Long Cycle Sodium-Ion Batteries

Sodium-ion batteries (SIBs) have garnered significant interest as one of the most promising energy suppliers for power grid energy storage. However, the poor electrode/electrolyte interfacial stability leads to continual electrolyte decomposition and transition metal dissolution, resulting in rapid performance degradation of SIBs. In this work, we propose a strategy integrating multiple functional bonds to regulate electrode/electrolyte interphase by triple-coupling of succinonitrile (SN), sodium hexafluorophosphate (NaPF 6 ) and fluorinated ethylene carbonate (FEC). Theoretical calculation and experiment results show that the solvation structure of Na + and ClO 4 – is effectively reconfigured by the solvated FEC, SN and PF 6 – in PC-based carbonate electrolyte. The newly developed electrolyte demonstrates increased Na + -FEC coordination, weakened interaction of Na + -PC and participation of SN and PF 6 – anions in solvation, resulting in the formation of a conformal interfacial layer comprising of sodium oxynitrides (NaN x O y ), sodium fluoride (NaF) and phosphorus oxide compounds (NaP x O y ). Consequently, a 3 Ah pouch full cell of hard carbon//NaNi 1/3 Fe 1/3 Mn 1/3 O 2 exhibits an excellent capacity retention of 90.4 % after 1000 cycles. Detailed postmortem analysis of interface chemistry is further illustrated by multiple characterization methods. Finally, this study provides a new avenue for developing electrolyte formulations with multiple functional bonds integrated interphases to significantly improve the long-term cycling stability of SIBs.

25 ENERGY STORAGE↗

Hard X-Ray Emission from the Eastern Jet of SS 433 Powering the W50 “Manatee” Nebula: Evidence for Particle Reacceleration

We present a broadband X-ray study of W50 (the “Manatee” nebula), the complex region powered by the microquasar SS 433, that provides a test bed for several important astrophysical processes. The W50 nebula, a Galactic PeVatron candidate, is classified as a supernova remnant but has an unusual double-lobed morphology likely associated with the jets from SS 433. Using NuSTAR, XMM-Newton, and Chandra observations of the inner eastern lobe of W50, we have detected hard nonthermal X-ray emission up to ~30 keV, originating from a few-arcminute-sized knotty region (“Head”) located ≲18' (29 pc for a distance of 5.5 kpc) east of SS 433, and constrained its photon index to 1.58 ± 0.05 (0.5–30 keV band). The index gradually steepens eastward out to the radio “ear” where thermal soft X-ray emission with a temperature kT ~ 0.2 keV dominates. The hard X-ray knots mark the location of acceleration sites within the jet and require an equipartition magnetic field of the order of ≳12 μG. The unusually hard spectral index from the “Head” region challenges classical particle acceleration processes and points to particle injection and reacceleration in the subrelativistic SS 433 jet, as seen in blazars and pulsar wind nebulae.

79 ASTRONOMY AND ASTROPHYSICS↗

Inferring the Energy and Distance Distributions of Fast Radio Bursts Using the First CHIME/FRB Catalog

Abstract Fast radio bursts (FRBs) are brief, energetic, typically extragalactic flashes of radio emission whose progenitors are largely unknown. Although studying the FRB population is essential for understanding how these astrophysical phenomena occur, such studies have been difficult to conduct without large numbers of FRBs and characterizable observational biases. Using the recently released catalog of 536 FRBs published by the Canadian Hydrogen Intensity Mapping Experiment/Fast Radio Burst (CHIME/FRB) collaboration, we present a study of the FRB population that also calibrates for selection effects. Assuming a Schechter function, we infer a characteristic energy cut-off of E char = 2.38 − 1.64 + 5.35 × 10 41 erg and a differential power-law index of γ = − 1.3 − 0.4 + 0.7 . Simultaneously, we infer a volumetric rate of [ 7.3 − 3.8 + 8.8 (stat.) − 1.8 + 2.0 ( sys . ) ] × 10 4 Gpc −3 yr −1 above a pivot energy of 10 39 erg and below a scattering timescale of 10 ms at 600 MHz, and find we cannot significantly constrain the cosmic evolution of the FRB population with star-formation rate. Modeling the host’s dispersion measure (DM) contribution as a log-normal distribution and assuming a total Galactic contribution of 80 pc cm −3 , we find a median value of DM host = 84 − 49 + 69 pc cm −3 , comparable with values typically used in the literature. Proposed models for FRB progenitors should be consistent with the energetics and abundances of the full FRB population predicted by our results. Finally, we infer the redshift distribution of FRBs detected with CHIME, which will be tested with the localizations and redshifts enabled by the upcoming CHIME/FRB Outriggers project.

79 ASTRONOMY AND ASTROPHYSICS↗

Young but fading radio sources: searching for remnants among compact steep-spectrum radio sources

The incidence of young but fading radio sources provides important information on the life cycle of radio emission in radio-loud active galactic nuclei. Despite its importance for constraining the models of radio source evolution, there are no systematic studies of remnants in complete samples of young radio sources. We report results of the study of 18 compact steep-spectrum (CSS) radio sources, selected from the statistically complete B3-VLA (Very Large Array) CSS sample, characterized by a steep optically thin spectrum (α ≥ 1.0) and no core detection in earlier studies. Our deep multifrequency VLA, pc-scale Very Long Baseline Array, and enhanced Multi Element Remotely Linked Interferometer Network (e-MERLIN) observations allowed us to locate the core component in 10 objects. In three CSS sources, there is no clear evidence of present-time active regions, suggesting that they are likely in a remnant phase. Among sources with core detection, we find three objects that have no clear active regions (hotspots) at the edges of the radio structure, suggesting that the radio emission may have just restarted. Our results support a power-law distribution of the source ages, although the poor statistics prevents us from setting solid constraints on the percentage of remnants and restarted sources in subpopulations of radio sources.

79 ASTRONOMY AND ASTROPHYSICS↗