Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power consumption”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Load-Responsive Motor Controller

New circuit controls voltage applied to a three-phase induction motor in response to magnitude of current, so as to reduce power consumption when the motor is idling or operating at less than full load. Control circuit decreases rms applied voltage to match decreases in motor load over entire torque range. This considerably decreases power consumption in motors operating at a fraction of their rated torques.

Edge, T. M.↗

An Integrated Circuit for Radio Astronomy Correlators Supporting Large Arrays of Antennas

Radio telescopes that employ arrays of many antennas are in operation, and ever larger ones are being designed and proposed. Signals from the antennas are combined by cross-correlation. While the cost of most components of the telescope is proportional to the number of antennas N, the cost and power consumption of cross-correlationare proportional to N2 and dominate at sufficiently large N. Here we report the design of an integrated circuit (IC) that performs digital cross-correlations for arbitrarily many antennas in a power-efficient way. It uses an intrinsically low-power architecture in which the movement of data between devices is minimized. In a large system, each IC performs correlations for all pairs of antennas but for a portion of the telescope's bandwidth (the so-called "FX" structure). In our design, the correlations are performed in an array of 4096 complex multiply-accumulate (CMAC) units. This is sufficient to perform all correlations in parallel for 64 signals (N=32 antennas with 2 opposite-polarization signals per antenna). When N is larger, the input data are buffered in an on-chipmemory and the CMACs are re-used as many times as needed to compute all correlations. The design has been synthesized and simulated so as to obtain accurate estimates of the IC's size and power consumption. It isintended for fabrication in a 32 nm silicon-on-insulator process, where it will require less than 12mm2 of silicon area and achieve an energy efficiency of 1.76 to 3.3 pJ per CMAC operation, depending on the number of antennas. Operation has been analyzed in detail up to N = 4096. The system-level energy efficiency, including board-levelI/O, power supplies, and controls, is expected to be 5 to 7 pJ per CMAC operation. Existing correlators for the JVLA (N = 32) and ALMA (N = 64) telescopes achieve about 5000 pJ and 1000 pJ respectively usingapplication-specific ICs in older technologies. To our knowledge, the largest-N existing correlator is LEDA atN = 256; it uses GPUs built in 28 nm technology and achieves about 1000 pJ. Correlators being designed for the SKA telescopes (N = 128 and N = 512) using FPGAs in 16nm technology are predicted to achieve about 100 pJ.

ASIC↗

Evaluation of Pulse Counting for the Mars Organic Mass Analyzer (MOMA) Ion Trap Detection Scheme

The Mars Organic Mass Analyzer is being developed at Goddard Space Flight Center to identify organics and possible biological compounds on Mars. In the process of characterizing mass spectrometer size, weight, and power consumption, the use of pulse counting was considered for ion detection. Pulse counting has advantages over analog-mode amplification of the electron multiplier signal. Some advantages are reduced size of electronic components, low power consumption, ability to remotely characterize detector performance, and avoidance of analog circuit noise. The use of pulse counting as a detection method with ion trap instruments is relatively rare. However, with the recent development of high performance electrical components, this detection method is quite suitable and can demonstrate significant advantages over analog methods. Methods A prototype quadrupole ion trap mass spectrometer with an internal electron ionization source was used as a test setup to develop and evaluate the pulse-counting method. The anode signal from the electron multiplier was preamplified. The an1plified signal was fed into a fast comparator for pulse-level discrimination. The output of the comparator was fed directly into a Xilinx FPGA development board. Verilog HDL software was written to bin the counts at user-selectable intervals. This system was able to count pulses at rates in the GHz range. The stored ion count nun1ber per bin was transferred to custom ion trap control software. Pulse-counting mass spectra were compared with mass spectra obtained using the standard analog-mode ion detection. Prelin1inary Data Preliminary mass spectra have been obtained for both analog mode and pulse-counting mode under several sets of instrument operating conditions. Comparison of the spectra revealed better peak shapes for pulse-counting mode. Noise levels are as good as, or better than, analog-mode detection noise levels. To artificially force ion pile-up conditions, the ion trap was overfilled and ions were ejected at very high scan rates. Pile-up of ions was not significant for the ion trap under investigation even though the ions are ejected in so-called 'ion-micro packets'. It was found that pulse counting mode had higher dynamic range than analog mode, and that the first amplification stage in analog mode can distort mass peaks. The inherent speed of the pulse counting method also proved to be beneficial to ion trap operation and ion ejection characterization. Very high scan rates were possible with pulse counting since the digital circuitry response time is so much smaller than with the analog method. Careful investigation of the pulse-counting data also allowed observation of the applied resonant ejection frequency during mass analysis. Ejection of ion micro packets could be clearly observed in the binned data. A second oscillation frequency, much lower than the secular frequency, was also observed. Such an effect was earlier attributed to the oscillation of the total plasma cloud in the ion trap. While the components used to implement pulse counting are quite advanced, due to their prevalence in consumer electronics, the cost of this detection system is no more than that of an analog mode system. Total pulse-counting detection system electronics cost is under $250

Van Amerom, Friso H.↗

Custom Unit Pump Design and Testing for the EVA PLSS

This paper describes the effort by the Texas Engineering Experiment Station (TEES) and Honeywell for NASA to design and test a pre-flight prototype pump for use in the Extra-vehicular activity (EVA) portable life support subsystem (PLSS). Major design decisions were driven by the need to reduce the pump s mass, power, and volume compared to the existing PLSS pump. In addition, the pump must accommodate a much wider range of abnormal conditions than the existing pump, including vapor/gas bubbles and increased pressure drop when employed to cool two suits simultaneously. A positive displacement, external gear type pump was selected because it offers the most compact and highest efficiency solution over the required range of flow rates and pressure drops. An additional benefit of selecting a gear pump design is that it is self priming and capable of ingesting non-condensable gas without becoming air locked. The chosen pump design consists of a 28 V DC, brushless, sealless, permanent magnet motor driven, external gear pump that utilizes a Honeywell development that eliminates the need for magnetic coupling. Although the planned flight unit will use a sensorless motor with custom designed controller, the pre-flight prototype to be provided for this project incorporates Hall effect sensors, allowing an interface with a readily available commercial motor controller. This design approach reduced the cost of this project and gives NASA more flexibility in future PLSS laboratory testing. The pump design was based on existing Honeywell designs, but incorporated features specifically for the PLSS application, including all of the key features of the flight pump. Testing at TEES verified that the pump meets the design requirements for range of flow rates, pressure drop, power consumption, working fluid temperature, operating time, gas ingestion , and restart capability under both ambient and vacuum conditions. The pump operated between 40 and 240 lbm/hr flowrate, 35 to 100 F pump temperature range, and 5 to 10 psid pressure rise. Power consumption of the pump controller at the nominal operating point in both ambient and vacuum conditions was 9.5 W, which was less than the 12 W predicted. Gas ingestion capabilities were tested by injecting 100 cc of air into the fluid line; the pump operated normally throughout this test. The test results contained a number of anomalies, specifically power increases and a few flow stoppages, that prompted TEES and Honeywell to disassemble and inspect the pump. Inspection indicated contamination in the pump and fit issues may have played roles in the observed anomalies. Testing following reassembly indicated that the performance of the pump 1) matched both the predicted performance values, 2) the performance values measured prior to disassembly, and 3) was free of the anomalies noted in the pre-disassembly testing.

Schuller, Michael↗

Custom Unit Pump Development for the EVA PLSS

This paper describes the effort by the Texas Engineering Experiment Station (TEES) and Honeywell for NASA to design and test a pre-flight prototype pump for use in the Extra-vehicular activity (EVA) portable life support subsystem (PLSS). Major design decisions were driven by the need to reduce the pump s mass, power, and volume compared to the existing PLSS pump. In addition, the pump must accommodate a much wider range of abnormal conditions than the existing pump, including vapor/gas bubbles and increased pressure drop when employed to cool two suits simultaneously. A positive displacement, external gear type pump was selected because it offers the most compact and highest efficiency solution over the required range of flow rates and pressure drops. An additional benefit of selecting a gear pump design is that it is self priming and capable of ingesting non-condensable gas without becoming air locked. The chosen pump design consists of a 28 V DC, brushless, seal-less, permanent magnet motor driven, external gear pump that utilizes a Honeywell development that eliminates the need for magnetic coupling. The pump design was based on existing Honeywell designs, but incorporated features specifically for the PLSS application, including all of the key features of the flight pump. Testing at TEES verified that the pump meets the design requirements for range of flow rates, pressure drop, power consumption, working fluid temperature, operating time, gas ingestion, and restart capability under both ambient and vacuum conditions. The pump operated at 40 to 240 lbm/hr flow rate, 35 to 100 oF pump temperature, and 5 to 10 psid pressure rise. Power consumption of the pump controller at the nominal operating point in both ambient and vacuum conditions was 9.5 W, which was less than the 12 W predicted. Gas ingestion capabilities were tested by injecting 100 cc of air into the fluid line; the pump operated normally throughout this test.

Schuller, Michael↗

Single Spatial-Mode Room-Temperature-Operated 3.0 to 3.4 micrometer Diode Lasers

Compact, highly efficient, 3.0 to 3.4 m light emitters are in demand for spectroscopic analysis and identification of chemical substances (including methane and formaldehyde), infrared countermeasures technologies, and development of advanced infrared scene projectors. The need for these light emitters can be currently addressed either by bulky solid-state light emitters with limited power conversion efficiency, or cooled Interband Cascade (IC) semiconductor lasers. Researchers here have developed a breakthrough approach to fabrication of diode mid-IR lasers that have several advantages over IC lasers used for the Mars 2009 mission. This breakthrough is due to a novel design utilizing the strain-engineered quantum-well (QW) active region and quinternary barriers, and due to optimization of device material composition and growth conditions (growth temperatures and rates). However, in their present form, these GaSb-based laser diodes cannot be directly used as a part of sensor systems. The device spectrum is too broad to perform spectroscopic analysis of gas species, and operating currents and voltages are too high. In the current work, the emitters were fabricated as narrow-ridge waveguide index-guided lasers rather than broad stripe-gain guided multimode Fabry-Perot (FP) lasers as was done previously. These narrow-ridge waveguide mid-IR lasers exhibit much lower power consumptions, and can operate in a single spatial mode that is necessary for demonstration of single-mode distributed feedback (DBF) devices for spectroscopic applications. These lasers will enable a new generation of compact, tunable diode laser spectrometers with lower power consumption, reduced complexity, and significantly reduced development costs. These lasers can be used for the detection of HCN, C2H2, methane, and ethane.

Frez, Clifford F.↗

Application of fiber optics in spacecraft

The unique requirements placed on an optical fiber data system in space are briefly reviewed in this paper. These include temperature extremes, particle radiation, and, in some cases, a stringent electrical power budget. An overriding need is for the best possible reliability. Results related to the power consumption of a fiber terminal pair are reported, with the conclusion that a 32-port transmission star bus configuration could be operated error-free at 10 Mbits/s on 1/8 watt per transmitting terminal. The design of a transmitter terminal optimized for low idling power consumption is discussed. Although the electronic elements on a spacecraft are protected, the fiber cable may be subjected to large temperature extremes. Measured effects of temperature on fibers and cables are discussed and related to bus design. Radiation effects are briefly reviewed, with special reference to the long-duration low dose rate environment of a spacecraft.

Johnston, A. R.↗

Electronically Variable Pressure Regulator (EVPR)

A new programmable electronically variable pressure regulator (EVPR) concept accurately controls the local outlet or remote system pressure. It uses an integral pulse width modulated rare earth permanent magnet motor operating in response to redundant pressure transducer feedback signals. The EVPR is a simple single stage device that does not use dynamic seals or pilot valving. Conversion of partial revolution motor torque to poppet lifting force is accomplished by pure flexure action to avoid using bearings. The flexure drive (called the ROTAX) has a variable lead to minimize motor weight and power consumption. Breadboard tests were completed successfully on two critical design elements of the EVPR: the ROTAX and the motor. The ROTAX cable system was tested for 250,000 cycles without failure. The breadboard motor met the basic design requirements including the design torque and power consumption. Prototype parts were fabricated, and testing of the prototype EVPR has started. It is PC computer controlled to facilitate programming, data acquisition and analysis. A lightweight dedicated microprocessor is planned for the flightweight EVPR.

Reinicke, R. H.↗

Analysis of an initial lunar outpost life support system preliminary design

A preliminary design of a life-support system (LSS) was developed as part of an ongoing comprehensive trade study of advanced processor technologies and system architectures for an initial lunar outpost. The design is based on a mission scenario requiring intermittent occupation of a lunar-surface habitat by a crew of four. It incorporates physiochemical process technologies that were considered for Space Station Freedom. A system-level simulation model of the design was developed to obtain steady-state material balances for each LSS processor. The mass-flow rate predictions were used to obtain estimates of the LSS mass, volume, and power consumption by means of processor-sizing correlations that were extrapolated from Space Station Freedom processor designs. The results were used to analyze the impacts of varying crew size, mission duration, processor-operation strategy, and crew-cabin loads on the LSS mass, average power consumption, volume, periodic resupply mass, and waste-accumulation rates. The merits of the design were quantified relative to an open-loop LSS, and the implications of this assessment for future LSS research and technology development were identified.

Ballin, Mark G.↗

Scattering Efficiency of High-Voltage Tethers in Space

Several concepts have been proposed to remediate the effect of artificial Radiation Belts (RB) in Space Plasma. Among them is the high-voltage electrostatic tether remediation technique. Preliminary analysis that has been carried out later by several groups showed, that this technique could be very efficient and is able to control relativistic electron energies of artificial RB population. The relativistic electron population is the one of the most important topic of US Space Weather studies and very dangerous to many civilian and military space assets, it is also important to study some fundamentals of scattering efficiency of high-voltage tethers in space plasma. There are several fundamental issues that should be examined in order to validate high-voltage tether artificial RB remediation concept. The most critical among them are: power consumption, the size and stability of the plasma sheath around the tether, and scattering efficiency of this high-voltage system that is ultimately related with the plasma sheath size. This study would be focused on the scattering process itself and artificial RB remediation assuming that power consumption and the size of the plasma sheath are known.

Krivorutsky, E. N.↗

Flight computers and sequencers

At present, the most common method of increasing reliability of a system against permanent random component failures is to triplicate the entire system and use voters. This method, though it enhances the reliability, does exact a heavy toll in weight and power consumption which increase by about 225%. In the future, computers will be required to perform complex tasks under adverse conditions on surfaces of planets for long periods of time (6 months or more), without any human intervention. At the same time there will be severe limitations on the weight and power consumption of these computers. For such systems it is obvious that simple triple-redundancy will not do. A more efficient and sophisticated design in redundancy has to evolve. This study has been directed toward that goal. It is understood that the initial design of such a system will be too complex and expensive to be used in a commercial computer; but for a space computer, reduction in weight (without reducing reliability) of every ounce means a great deal.

REDUNDANCY↗

Performance of a Borehole X-ray Fluorescence Spectrometer for Planetary Exploration

We have designed and constructed a borehole X-ray Fluorescence Spectrometer (XRFS) as part of the Mars Subsurface Access program [1]. It can be used to determine the composition of the Mars regolith at various depths by insertion into a pre-drilled borehole. The primary requirements and performance metrics for the instrument are to obtain parts-per-million (ppm) lower limits of detection over a wide range of elements in the periodic table (Magnesium to Lead). Power consumption during data collection was also measured. The prototype instrument is complete and preliminary testing has been performed. Terrestrial soil Standard Reference Materials were used as the test samples. Detection limits were about 10 weight ppm for most elements, with light elements being higher, up to 1.4 weight percent for magnesium. Power consumption (excluding ground support components) was 12 watts.

Kelliher, Warren C.↗

A low-cost, CCD solid state star tracker

Applied Research Corporation (ARC) has developed an engineering model of a multi-star CCD-based tracker for space applications requiring radiation hardness, high reliability and low power consumption. The engineering unit compared favorably in functional performance tests to the standard NASA single-star tracker. Characteristics of the ARC star tracker are: field of view = 10 deg x 7.5 deg, sensitivity range of -1 to +5 star magnitude, NEA = 3 in x 3 in, linearity = 5 in x 5 in, and power consumption of 1-3 W (operating mode dependent). The software is upgradable through a remote link. The hardware-limited acquisition rate is 1-5 Hz for stars of +2 to +5 magnitude and 10-30 Hz for -1 to +2 magnitude stars. Mechanical and electrical interfaces are identical to the standard NASA star tracker.

Chmielowski, M.↗

Performance of a Borehole XRF Spectrometer for Planetary Exploration

We have designed and constructed a borehole XRF Spectrometer (XRFS) as part of the Mars Subsurface Access program. It will be used to determine the composition of the Mars regolith at various depths by insertion into a pre-drilled borehole. The primary performance metrics for the instrument are the lower limits of detection over a wide range of the periodic table. Power consumption during data collection was also measured. The prototype instrument is complete and preliminary testing has been performed. Terrestrial soil Standard Reference Materials were used as the test samples. Detection limits were about 10 weight parts-per-million for most elements, with light elements being higher, up to 1.4 weight percent for magnesium. Power consumption (excluding ground support components) was 12 watts.

Kelliher, Warren C.↗

The Biolink Implantable Telemetry System

Most biotelemetry applications deal with the moderated data rates of biological signals. Few people have studied the problem of transcutaneous data transmission at the rates required by NASA's Life Sciences-Advanced BioTelemetry System (LS-ABTS). Implanted telemetry eliminate the problems associated with wire breaking the skin, and permits experiments with awake and unrestrained subjects. Our goal is to build a low-power 174-216MHz Radio Frequency (RF) transmitter suitable for short range biosensor and implantable use. The BioLink Implantable Telemetry System (BITS) is composed of three major units: an Analog Data Module (ADM), a Telemetry Transmitter Module (TTM), and a Command Receiver Module (CRM). BioLink incorporates novel low-power techniques to implement a monolithic digital RF transmitter operating at 100kbps, using quadrature phase shift keying (QPSK) modulation in the 174-216MHz ISM band. As the ADM will be specific for each application, we focused on solving the problems associated with a monolithic implementation of the TTM and CRM, and this is the emphasis of this report. A system architecture based on a Frequency-Locked Loop (FLL) Frequency Synthesizer is presented, and a novel differential frequency that eliminates the need for a frequency divider is also shown. A self sizing phase modulation scheme suitable for low power implementation was also developed. A full system-level simulation of the FLL was performed and loop filter parameters were determined. The implantable antenna has been designed, simulated and constructed. An implant package compatible with the ABTS requirements is also being proposed. Extensive work performed at 200MHz in 0.5um complementary metal oxide semiconductors (CMOS) showed the feasibility of integrating the RF transmitter circuits in a single chip. The Hajimiri phase noise model was used to optimize the Voltage Controlled Oscillator (VCO) for minimum power consumption. Two test chips were fabricated in a 0.5pm, 3V CMOS process. Measured phase noise for a 1.5mW, 200MHz ring oscillator VCO is -80dBc/Hz at 100KHZ offset, showing good agreement with the theory. We also propose a novel superregenerative receiver architecture for implementing the command receiver. The superregenerative receiver's simplicity, low cost, and low power consumption has made it the receiver of choice for short-distance data communications, remote control and home automation. We present the design of a superregenerative AM receiver implemented in a 0.5um CMOS technology that operates at 433.92MHz and dissipates only 300uW. Further work entails detailed transistor-level design of the FLL and superregenerative receiver and a monolithic implementation of an implantable transceiver in 0.5um CMOS technology.

Betancourt-Zamora, Rafael J.↗

Low-Power Temperature-Swing Adsorption for Mars Atmosphere Acquisition

The promise of ISRU-based mission architectures for Mars surface exploration will begin to be realized during the next decade as robotic spacecraft sent to Mars carry components and whole chemical plants for producing propellants from the planet's atmosphere. These chemical plants will need to perform three primary operations: acquisition of atmospheric carbon dioxide, reactions to transform the gas into oxygen and possibly fuel, and storage of the products. This presentation focuses on development of technologies at NASA Ames Research Center for the first of these operations, carbon dioxide acquisition. The carbon dioxide acquisition component for a propellant production plant has several general, top level requirements. It has a stringent requirement for minimal power consumption; a critical need for long-term reliability over the period of time the chemical plant must operate (say, 500 days); a production rate requirement for carbon dioxide; and a state point requirement (particularly pressure) for the CO2 produced. The first two requirements help determine the best technological approach, while the latter two generally define the characteristics (e.g., size and power consumption) of the device. Mass and volume must be minimized, as usual.

Finn, J. E.↗

Air Stripping Designs and Reactive Water Purification Processes for the Lunar Surface

Air stripping designs are considered to reduce the presence of volatile organic compounds in the purified water. Components of the wastewater streams are ranked by Henry's Law Constant and the suitability of air stripping in the purification of wastewater in terms of component removal is evaluated. Distillation processes are modeled in tandem with air stripping to demonstrate the potential effectiveness and utility of these methods in recycling wastewater on the Moon. Scaling factors for distillation and air stripping columns are presented to account for the difference in the lunar gravitation environment. Commercially available distillation and air stripping units which are considered suitable for Exploration Life Support are presented. The advantages to the various designs are summarized with respect to water purity levels, power consumption, and processing rates. An evaluation of reactive distillation and air stripping is presented with regards to the reduction of volatile organic compounds in the contaminated water and air. Among the methods presented, an architecture is presented for the evaluation of the simultaneous oxidation of organics in air and water. These and other designs are presented in light of potential improvements in power consumptions and air and water purities for architectures which include catalytic activity integrated into the water processor. In particular, catalytic oxidation of organics may be useful as a tool to remove contaminants that more traditional distillation and/or air stripping columns may not remove. A review of the current leading edge at the commercial level and at the research frontier in catalytically active materials is presented. Themes and directions from the engineering developments in catalyst design are presented conceptually in light of developments in the nanoscale chemistry of a variety of catalyst materials.

Boul, Peter J.↗

Space-qualified submillimeter radiometer

The purpose of this research was to develop a reliable submillimeter wave spectrometer for space-borne high frequency spectral line work. The emphasis was on improving the efficiency of frequency multipliers to limit the system components to rugged, low power consumption solid-state devices. This research has allowed Millitech to develop increased efficiency and performance in Millitech's existing line of submillimeter components and systems. Millitech has fabricated and tested a complete solid-state spectrometer front end for use at 560 GHz (the 1(sub 10) to 1(sub 01) transition of water vapor). The spectrometer was designed with the rigors of flight conditions in mind. The spectrometer uses a phase-locked, solid-state Gunn diode oscillator as the local oscillator, employing a tripler to produce about 3 mW of power at 285 GHz, and a low noise second harmonic waveguide mixer which requires less than 2 mW of LO power. The LO (and the signal) is injected into the mixer by means of a quasioptical diplexer. The measured system noise temperature is 2800 K (DSB) over 400 MHz. The whole spectrometer front end is compact (21 cm by 21 cm by 24 cm), light (7.4 kg), and has a power consumption of less than 8 W. Other topics explored in this work include compact frequency agile phase lock loops, optical filters, and InP Gunn oscillators for low noise applications. As a result of this research, the improvement in the design of multipliers and harmonic mixers will allow their use as the LO power for a variety of satellite-borne receivers operating in the 200 to 600 GHz frequency range.

Huguenin, G. R.↗