Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “poroelasticity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Modeling-Based Assessment of Deep Seismic Potential Induced by Geologic Carbon Storage

Induced seismicity is an inherent risk associated with geologic carbon storage (GCS) in deep rock formations that could contain undetected faults prone to failure. Modeling-based risk assessment has been implemented to quantify the potential of injection-induced seismicity, but typically simplified multiscale geologic features or neglected multiphysics coupled mechanisms because of the uncertainty in field data and computational cost of field-scale simulations, which may limit the reliable prediction of seismic hazard caused by industrial-scale CO 2 storage. The degree of lateral continuity of the stratigraphic interbedding below the reservoir and depth-dependent fault permeability can enhance or inhibit pore-pressure diffusion and corresponding poroelastic stressing along a basement fault. In conclusion, this study presents a rigorous modeling scheme with optimal geological and operational parameters needed to be considered in seismic monitoring and mitigation strategies for safe GCS.

58 GEOSCIENCES↗

Computational Analysis of Coupled Geoscience Processes in Fractured and Deformable Media

Prediction of flow, transport, and deformation in fractured and porous media is critical to improving our scientific understanding of coupled thermal-hydrological-mechanical processes related to subsurface energy storage and recovery, nonproliferation, and nuclear waste storage. Especially, earth rock response to changes in pressure and stress has remained a critically challenging task. In this work, we advance computational capabilities for coupled processes in fractured and porous media using Sandia Sierra Multiphysics software through verification and validation problems such as poro-elasticity, elasto-plasticity and thermo-poroelasticity. We apply Sierra software for geologic carbon storage, fluid injection/extraction, and enhanced geothermal systems. We also significantly improve machine learning approaches through latent space and self-supervised learning. Additionally, we develop new experimental technique for evaluating dynamics of compacted soils at an intermediate scale. Overall, this project will enable us to systematically measure and control the earth system response to changes in stress and pressure due to subsurface energy activities.

58 GEOSCIENCES↗

Interpretation of borehole strain measurements using surrogate modeling-based optimization

Interpreting strain data measured during well testing requires inverting poroelastic forward models set up to represent an aquifer or reservoir. One approach is to use stochastic methods to conduct the inversion. Subsurface parameters such as elastic modulus, permeability, and geometry of heterogeneities are estimated by searching the parameter space. This is feasible, but cumbersome, requiring more than a week of computation using many hundreds of computer nodes in one of our earlier analyses. This motivated us to consider alternative methods, including an artificial neural network (ANN) as a surrogate model.

Roudini, Soheil↗

Field Results from New Tensor Borehole Optical Fiber Strainmeter Installations in Oklahoma and Utah

The time evolving strain field contains a wealth of information that can be used to interpret subsurface behavior. For example, injecting or removing fluids from reservoirs or aquifers causes deformation that can be used as a diagnostic signal in some cases, while it can interfere with geodetic interpretations in other cases. We've previously demonstrated the feasibility of measuring the strain tensor at a depth of 30m caused by injection into a reservoir at 530m. The observed strain signals were interpreted using four independent analytic and numerical methods that resulted in estimates of the poroelastic properties and geometry of the reservoir that was consistent with data from well logs. However, studies like these are only possible if these deformations can be reliably measured. Years of lab and field work has culminated in the development of a novel borehole strainmeter capable of resolving multiple components of strain using embedded optical fibers configured as Michelson interferometers. It features four horizontal gauges separated by 45° to resolve the horizontal strain tensor as well as a vertical strain gauge and a sixth null component for state-of-health monitoring. The downhole sensing package also includes an open pipe through its center for grout circulation during single-trip deployments and a fully welded stainless steel exterior for robustness and longevity. These instruments have a resolution of 2x10-13 strain that can easily measure the solid earth tides. Preliminary data are available from four strainmeters in shale at our Oklahoma site and four in compacted sand and gravel in Utah. These are deployed from 40-60m, except one of the strainmeters in Oklahoma is deployed at 500m. The data include strains from the initial grout curing, comparisons to predicted earth tide models and in-situ calibration results, barometric pressure admittances and spectral analyses as well as signals from underground injections and surface waves from teleseismic events. Preliminary analyses indicate behavior consistent with other strainmeter deployments, and comparison to data from a Gladwin strainmeter at the Oklahoma site validate the performance of the new design. Analyses from a suite of six well tests at the Oklahoma site show for the first time how the strain tensor field varies with location during well testing.

DeWolf, Scott↗

DECOVALEX-2023: Task E Final Report

This is the Task E final report for DECOVALEX-2023. Task E is focused on understanding thermal, two-phase hydrological, and mechanical (TH2M) processes, especially related to predicting brine migration in the excavation damaged zone around a heated excavation in salt. Salt is attractive as a disposal medium for radioactive waste because it is self-healing and is essentially impermeable and essentially non-porous in the far field (away from excavations). Investigation of the short-term (days to years) near-field (centimeters to tens of meters) behavior of salt is important for radioactive waste disposal because this early period strongly controls the amount of brine in a salt repository. Brine leads to corrosion of waste forms and waste packages, and possible dissolution of radionuclides with brine transport being a potential transport vector to the accessible environment. The main test case used in Task E is the ongoing Brine Availability Test in Salt (BATS) heater test located underground at the Waste Isolation Pilot Plant (WIPP) near Carlsbad, New Mexico, USA. The Task was divided into a series of Steps. Step 0 was an introduction to processes in salt, that included matching historical unheated brine inflow data from boreholes at WIPP and matching temperature observations during BATS heater test 1a. Step 1 included validation of models against a thermo-poroelastic analytical solution relevant to heated boreholes in salt, and two-phase flow around an excavation in salt. Step 2 required all the individual components covered in steps 0 and 1 to come together to match observed brine inflow behavior during the BATS 1a heater test. There were a range of approaches from the teams, from mechanistic to prescriptive. Given the uncertainties in the problem, some teams used one- or two-dimensional models of the processes, while other teams included more geometrical complexity in three-dimensional models. The key learning points from Task E have been: • Heat conduction through salt typically requires non-linear thermal conductivity (as a function of temperature), but most models do a good job matching observations, given appropriate adjustments to the applied power and some thermocouple locations. • Thermal pressurization requires coupled thermal-hydrological-mechanical (THM) responses that consider the thermal expansion of the fluid and solid phases. • Initialization of two-phase flow models around a borehole or excavation in salt are more realistically represented as “wetting up”, rather than “drying down” (i.e., the initial state after excavation is mostly dry, rather than mostly wet). • The BATS 1a heater test includes a significant release of brine after the end of heating, which requires a large increase in permeability to recreate. Task E has been a great learning experience for all the teams involved, and feedback from the modeling teams has led to changes in the design of follow-on BATS experiments, which are now ongoing underground at WIPP. There was a balance throughout the task between freedom to model phenomena how each team saw fit, and prescriptiveness in problem design to bring the modeling teams closer together to allow attribution of smaller differences between models to different modeling choices. The modeling approaches seem to go through two phases: an early phase of discovery or testing, and a later phase of refinement and improvement. In future modeling efforts, different field data could be used (e.g., BATS 2) and more time should be included in the processes for teams to make multiple model refinement or even significant changes to their conceptual model or setup, based on lessons learned from the modeling exercise.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Technical Report on Subsurface Monitoring of the Brady Hot Spring Geothermal Site, Nevada, based upon Full Waveform Inversion

Abilities to accurately characterize the subsurface in a geothermal setting is key to assess and support production. An important element of geothermal reservoir monitoring is also the ability to investigate fluid transport within fracture network. This report focuses on improving subsurface imaging and monitoring in geothermal settings using full waveform inversion based on the adjoint method and time-lapse imaging. To assess our method, we rely on a dense seismic dataset collected in 2016 at the Brady Hot Springs geothermal site in Nevada for the DOE-funded project Poroelastic Tomography by Adjoint Inverse Modeling of Data from Seismology, Geodesy, and Hydrology. This dataset captures subsurface changes across four stages of geothermal power plant operations, which involve varying rates of fluid injection and extraction. Two velocity models were previously derived from this dataset using different methods: one based on travel times and another on sweep interferometry. Our first step is to refine these models using adjoint tomography, which has been applied successfully at global and regional-scales but is less common at the reservoir-scale. Two approaches are then explored for time-lapse analysis: directly comparing refined tomographic models from different stages or backpropagating waveform differences relative to a baseline tomographic model. The main take away is that both approaches highlight similar reservoir behaviors, but the latter approach is more computationally effective in capturing small-scale changes in subsurface properties. For this work, we leverage the use of Salvus (www.mondaic.com), an end-to-end seismic imaging solution, relying on the spectral element method to compute forward and adjoint simulations, and developed by Mondaic Ltd. It includes integrated workflow management that handles waveform and metadata, launches simulations, computes waveform misfits and adjoint sources, and iterates for model updates by nonlinear optimization.

15 GEOTHERMAL ENERGY↗

Identification of Faults Susceptible to Induced Seismicity (Final Report)

Central to the work documented in this report is the capability of geocellular models to represent the geologic conceptual model updated with fault identification from machine learning and joint inversion modeling of microseismic data measured and recorded as a consequence of CO 2 injection at a field demonstration site: the Illinois Basin - Decatur Project (IBDP). This work required seven unique geocellular models with 100s of simulated variations to gain a very high degree of confidence in the identification of geologic features present that contributed to induced microseismicity at IBDP. All forward modeling: pressure modeling, stress modeling, and seismic modeling used the same geologic conceptual model and representations of that model at different scales. The pressure modeling and poroelastic modeling created “snapshots” of pore pressure and stress field changes at different times during CO 2 injection, in which microseismic events were clustered (in time). These pressure and stress snapshots, within the framework and architecture of the geologic conceptual model via the geocellular model, informed the single fault and fault network models to ascertain the likelihood of fault movement (seismic or aseismic). The outcomes of the pressure, stress, and fault/fault network (seismic) modeling confirmed that the faults in the geologic conceptual model in Task 2 were likely the source of microseismic events measured at IBDP and acted as conduits for pressure to be transmitted from the injection interval into the Precambrian crystalline basement rock. This closely coordinated and integrated unique modeling approach was conducted to prove the viability of our proposed workflow 1) to better resolve crystalline basement faults, 2) detect subseismic faults that could be activated by injection, 3) increase the certainty in fault detection and their susceptibility to release seismic energy, and 4) understand transmission of pressure vertically from the well to the underlying fractured crystalline basement. The proposed methodology was effective in guiding an iterative process of calibrating forward modeling results based on similar geocellular models while honoring the geologic conceptual model (i.e., characterization data and knowledge of regional geology); this led to higher level of certainty in the identification of fault/faults zones to control seismicity and transmission of pressure to the regions of recorded and located injection induced seismicity.

58 GEOSCIENCES↗

In-Situ Stress Measurements at the Utah Frontier Observatory for Research in Geothermal Energy (FORGE) Site

A scientific injection campaign was conducted at the Utah Frontier Observatory for Research in Geothermal Energy (FORGE) site in 2017 and 2019. The testing included pump-in/shut-in, pump-in/flowback, and step rate tests. Various methods have been employed to interpret the in-situ stress from the test dataset. This study focuses on methods to interpret the minimum in-situ stress from step rate, pump-in/extended shut-in tests data obtained during the stimulation of two zones in Well 58-32. This well was drilled in low-permeability granitoid. A temperature of 199 °C was recorded at the well’s total depth of 2297 m relative to the rotary Kelly bushing (RKB). The lower zone (Zone 1) consisted of 46 m of the openhole at the toe of the well. Fractures in the upper zone (Zone 2) were stimulated between 2123–2126 m measured depths (MD) behind the casing. The closure stress gradient variation depended on the depth and the injection chronology. The closure stress was found to increase with the pumping rate/volume. This stress variation could indicate that poroelastic effects (“back stress”) and the presence of adjacent natural fractures may play an important role in the interpretation of fracture closure stress. Further, progressively increasing local total stresses may, consequently, have practical applications when moderate volumes of fluid are injected in a naturally fractured or high-temperature reservoir. The alternative techniques that use pump-in/flowback tests and temperature signatures provide a valuable perspective view of the in-situ stress measurements.

15 GEOTHERMAL ENERGY↗

Multi‐scale simulation of rock compaction through breakage models with microstructure evolution

Abstract. Regional subsidence due to fluid depletion includes the interaction among multiple physical processes. Specifically, rock compaction is governed by coupled hydro-mechanical feedbacks involving fluid flow, effective stress change and pore collapse. Although poroelastic models are often used to explain the delay between depletion and subsidence, recent evidence indicates that inelastic effects could alter the rock microstructure, thus exacerbating coupling effects. Here, a constitutive law built within the framework of Breakage Mechanics is proposed to account for the inherent connection between rock microstructure, hydraulic conductivity, and pore compaction. Furthermore, it is embedded into a 1-D hydromechanical coupled finite element analysis (FEA) to explore the effects of micro-structure rearrangement on the development of reservoir compaction. Numerical examples with the proposed model are compared with simulations under constant hydraulic conductivity to illustrate the model capability to capture the non-linear processes of reservoir compaction induced by fluid depletion.

Buscarnera, Giuseppe↗

A finite element method for the thermochemical decomposition of polymeric materials. I - Theory

The governing differential equations are developed to model the thermomechanical behavior of chemically decomposing, polymeric materials. These equations account for thermal and gaseous diffusion through a poroelastic, transversely isotropic solid. The Bubnov-Galerkin finite element method is applied to the governing equations to cast the coupled set into a single matrix equation. A method for solving these equations simultaneously at each time step is discussed.

Sullivan, R. M.↗

A finite element method for the thermochemical decomposition of polymeric materials. II - Carbon phenolic composites

A previously developed formulation for modeling the thermomechanical behavior of chemically decomposing, polymeric materials is verified by simulating the response of carbon phenolic specimens during two high temperature tests: restrained thermal growth and free thermal expansion. Plane strain and plane stress models are used to simulate the specimen response, respectively. In addition, the influence of the poroelasticity constants upon the specimen response is examined through a series of parametric studies.

Sullivan, R. M.↗

Measurements of Acoustic Properties of Porous and Granular Materials and Application to Vibration Control

For application of porous and granular materials to vibro-acoustic controls, a finite dynamic strength of the solid component (frame) is an important design factor. The primary goal of this study was to investigate structural vibration damping through this frame wave propagation for various poroelastic materials. A measurement method to investigate the vibration characteristics of the frame was proposed. The measured properties were found to follow closely the characteristics of the viscoelastic materials - the dynamic modulus increased with frequency and the degree of the frequency dependence was determined by its loss factor. The dynamic stiffness of hollow cylindrical beams containing porous and granular materials as damping treatment was measured also. The data were used to extract the damping materials characteristics using the Rayleigh-Ritz method. The results suggested that the acoustic structure interaction between the frame and the structure enhances the dissipation of the vibration energy significantly.

Park, Junhong↗

A fiber matrix model for fluid flow and streaming potentials in the canaliculi of an osteon

A theoretical model is developed to predict the fluid shear stress and streaming potential at the surface of osteocytic processes in the lacunar-canalicular porosity of an osteon when the osteon is subject to mechanical loads that are parallel or perpendicular to its axis. The theory developed in Weinbaum et al. (31) for the flow through a proteoglycan matrix in a canaliculus is employed in a poroelastic model for the osteon. Our formulation is a generalization of that of Petrov et al. (17). Our model predicts that, in order to satisfy the measured frequency dependence of the phase and magnitude of the SGP in macroscopic bone samples, the fiber spacing in the fluid annulus must lie in the narrow range 6-7 nm typical of the spacing of GAG sidechains along a protein monomer. The model predictions for the local SGP profiles in the osteon agree with the experimental observations of Starkebaum et al. (24). The theory predicts that the pore pressure relaxation time, tau d, for a 150-300 microns diameter osteon with the foregoing matrix structure is approximately 0.03-0.13 sec, and that the amplitude of the mean fluid shear stress on the membrane of the osteocytic process at the mean areal radius of the osteon has a maximum at 28 Hz if tau d = 0.06 sec. This maximum, which is independent of the magnitude of the loading, could be important in vivo since the recent experiments of Turner et al. (28) and McLeod et al. (15) have a peak in the strain frequency spectrum between 20 and 30 Hz that also appears to be independent of the type (magnitude) of loading. Numerical predictions for the amplitude of the average fluid shear stress on the osteocytic membrane at the mean areal radius of the osteon show that the fluid shear stress associated with the low amplitude 20-30 Hz spectral strain component is at least as large as the average fluid shear stress associated with the high amplitude 1 Hz stride component, although the latter loading is an order of magnitude larger, and has a magnitude that lies within the middle of the range, 6-30 dynes/cm2, where fluid shear stresses in tissue culture studies with osteoblast monolayers have elicited an intracellular Ca++ response (31). The implications of these results for intracellular electrical communication are discussed.

Non-NASA Center↗

Development of Acoustic Mufflers for Cabin Noise Reduction in Orion Spacecraft

Controlling cabin acoustic noise levels in the Crew Module (CM) of the Orion spacecraft is critical to ensure adequate speech intelligibility, to avoid fatigue, and prevent any possibility of temporary and permanent hearing loss to the crew. The primary source of cabin noise for the on-orbit phase of the mission is from the Environmental Control and Life Support System (ECLSS) which recycles and conditions breathing air and maintains cabin pressurization through its duct network and components. Unfortunately, as a side effect, noise from the ECLSS fans propagates through theses ducts and emanate into the cabin habitable volume via the ECLSS inlet and outlets. To mitigate excessive duct-borne noise, two ECLSS mufflers have been designed to provide significant acoustic transmission loss (TL) so that the cabin noise requirements can be met. Each muffler is meant to be installed in the ducting of the ECLSS air inlet and outlet sides, respectively. Packaging constraints and tight volume requirements necessitated the mufflers to be of complex geometry and compatible with the bends of the ECLSS duct layout. To design and characterize the acoustic performance of the inlet and outlet mufflers, computational acoustic models were developed using the Finite Element Method (FEM) with 𝑤𝑎𝑣𝑒଺ vibroacoustic software. Characterization of the acoustic material and perforations in the mufflers were addressed with poroelastic theory. Once the mufflers were designed on paper and its TL predicted, prototypes of these mufflers were created using additive manufacturing. The muffler prototypes were subsequently tested for acoustic TL in the laboratory with various con-figurations of acoustic materials. Comparing the analytical predictions to the test performance yielded excellent correlation for acoustic TL and demonstrated significant broadband noise attenuation. The ECLSS mufflers are currently scheduled to be installed on the Artemis II Crew Module (CM) of the Orion spacecraft and will provide significant cabin comfort to crew during the mission.

Indranil Dandaroy↗

Local Ultrasonic Resonance Spectroscopy of Lithium Metal Batteries for Aerospace Applications

As next-generation aircraft and vehicles continue to develop, so do their associated energy demands. Lithium metal batteries are a leading candidate to fulfill this energy requirement, but these batteries are prone to internal dendrite defects that can lead to catastrophic thermal runaway events. Current battery management systems are capable of mitigating such risks, but are unable to detect such defects until thermal runaway has already begun. Various nondestructive evaluation (NDE) techniques, particularly ultrasonic NDE, can directly monitor internal battery parameters giving them the potential to detect critical defects prior to catastrophic failure. However, most of the current battery NDE research has focused on improved battery state-of-charge (SOC) and stateof- health (SOH) monitoring with little emphasis on critical defect detection. Thus, a measurement technique sensitive to subtle battery defects is needed. In addition, the complex mechanics of ultrasound in porous, thin, multilayered batteries prompt the use of physics-based simulation to guide inspections. In this work, an ultrasonic NDE technique has been developed utilizing frequency domain analysis of local battery resonances to detect the presence of battery defects. This technique is a practical extension of local ultrasonic resonance spectroscopy (LURS) – which previously required non-contact laser ultrasonics – to measurements with piezoelectric contact and immersion scan transducers. To extend the technique to work with piezoelectric transducers, ultrasonic battery measurements were compared to a sans-battery calibration measurement. Then, a linear systems deconvolution was used to eliminate the transfer functions of extraneous factors such as the transducer and electronics, leaving only the frequency-dependent battery reflection coefficient. The LURS technique was first validated on stainless steel and aluminum plates, producing reflection coefficients in line with analytical and numerical finite element modeling (FEM) results. Functioning Li-metal pouch cells were then seeded with lithium chip defects prior to LURS measurements. The presence of these defects is shown to cause a measurable shift in the battery’s through-thickness local resonances. 2D, frequency-domain poroelastic models of ultrasonic propagation in a single-cell lithium metal pouch battery were created and corroborated these findings. Thus, this work has both extended and proven the feasibility of the LURS technique in the detection of local battery defects.

Ultrasound↗

Material Property Estimation in Thin Battery Components Using Guided Wave Measurement, Experimental Dispersion Curve Extraction and Finite Element Modeling

At NASA, we are investigating nondestructive evaluation (NDE) and structural health monitoring (SHM) techniques to detect precursors of thermal runaway failure in lithium metal based lithium ion batteries (LIB). The approach is centered on computational simulation models to guide inspection and aid in interpretation of results. Since lithium metal LIBs have combinations of solid and fluid-filled porous materials, obtaining accurate material properties is both challenging and critical for successful simulation of battery inspection. To this end, we investigated a multi-verification approach for material characterization of thin battery components. First, a laser Doppler vibrometer (LDV) was used to measure guided wave fields in thin (microns-thick) battery components subject to broadband excitation. The time-space wavefield data was converted to frequency-wave number data to extract guided wave dispersion curves. A data visualization and post processing graphics user interface (GUI) was developed at NASA to aid the data exploration and analysis. Due to the thinness of the samples, low frequency-thickness-product plate wave approximations allowed for the calculation of closed-form solutions for material elastic property estimation. These approximations were then verified by calculating the Lamb wave solutions using the previously obtained material properties. Finally, the estimated elastic material properties were implemented in a COMSOL simulation model, and dispersion curves were extracted from simulation results. The dispersion curves and derived material properties were then compared to the analysis results from the experimental data. These comparisons informed on the accuracy of the measured material properties and helped demonstrate the accuracy of the finite element analysis (FEA) computational models. This assessment will prove vital when we start simulating more complex multi-layer components and poroelastic media. This paper gives a brief background of the problem space, outlines the workflow for data analysis and verification, shows results from the workflow, and gives an overview of future plans for simulation of lithium metal LIB inspection.

Peter Juarez↗

The EGS Collab Project: Learnings from Experiment 1

The primary objective of the EGS Collab Project sponsored by DOE is to increase the understanding needed to efficiently implement enhanced geothermal systems (EGS). One goal of the EGS Collab project is to create a collaborative research environment in which to study stimulation of crystalline rock at the 10 meter scale. Key to this effort is the collection of high quality data to allow comparison to numerical coupled process models in an effort to build confidence in the codes and modeling techniques used. In response to this, the EGS Collab team has created an underground test bed at the Sanford Underground Research Facility (SURF) in Lead SD at a depth of approximately 1.5 km to examine hydraulic fracturing (Experiment 1). We are currently designing a second test bed aimed at investigating shear stimulation (Experiment 2). At the Experiment 1 location, we have characterized our host rock using laboratory testing and numerous field-based geophysical and geological techniques, and created a well-instrumented test bed to allow us to carefully monitor stimulation events and flow tests. In addition to the installed geophysical sensors, we have used tracer tests, differences in the ambient microbial communities at flow collection locations, and cold water injection to inform us about dynamic flow pathways. In Experiment 1, we have hydraulically stimulated the host rock in a number times at several locations in one well, creating new fractures that connect to existing fractures between the injection and production boreholes. We have performed long-term ambient and chilled water injection tests as an analog to EGS, and have monitored system changes resulting from these water injections through geophysical monitoring, flow and pressure measurements, tracer tests, and microbiology. Here, we summarize the tests performed, issues identified including poroelastic and thermoelastic effects, Joule-Thomson effects, restarting effects, indications of flow channeling, and the primary learnings from Experiment 1.

Enhanced Geothermal Systems, EGS Collab, stimulati↗

A Novel Technique for Distributed Measuring of Strain in the Vadose Zone

Characterizing water content and pressure changes in the vadose zone is important to understanding a variety of geologic processes, ranging from permeability, to evapotranspiration, and aquifer recharge. Changes in water content, or pressure, cause strain in the solid porous medium of the vadose zone, and it is possible that measuring those strains could be used a characterization tool. The Coherence-length-gated Microwave Photonics Interferometry (CMPI) technique measures strain at high resolution along many intervals defined by pairs of reflectors distributed along an optical fiber. This technique has recently been developed at Clemson University, and it has the spatial, and temporal resolution to characterize the strains that are expected to occur with hydrologic changes in the vadose zone. However, the technique has never been used to measure strain in porous media, so its capabilities remain uncertain. The objective of this thesis is to evaluate the ability of using CMPI to measure strain changes in the vadose zone. The research approach consists of conducting laboratory tests using a column filled with sand that was subjected to changes in water content and pressure. An optical fiber with CMPI reflectors was deployed in a high surface area ribbon and used to measure strain along the axis of the column. The column was made from 8-inch, Schedule 40 PVC pipe (75 cm tall, 20 cm inner diameter) and filled with medium-grained sand (K = 2.5x10-6 m/s, porosity = 0.28, Coefficient of Uniformity = 2, van Genuchten (n = 4.34 and  = 0.00039 m-1), Young’s Modulus = 18 – 47 MPa). Five pressure and four temperature sensors attached to probes inserted into the wall. The optical fiber includes five reflectors spaced 10 cm apart on the inside and outside of the column along the vertical axis. Strain measurements are made between pairs of reflectors. The reflectors are created in 250-micron-diameter acrylate-coated single mode Corning SMF28e+ optical fiber using a femtosecond laser. The optical fiber was laminated between two pieces of polyester film creating a large surface area to transfer strain from the porous media to the optical fiber. The experiments were conducted by filling the column from the bottom or infiltrating water from the top. The water was allowed to equilibrate to room temperature prior to each test in order to limit thermoelastic strain. Five injection tests with a rate of 250 ml/min and three infiltration tests at varying rates were conducted, and the results show patterns of strain and pressure are generally similar. Hydrologic conditions define three zones based on the pressure magnitude and distribution. 1.) Ambient Zone where the pressure heads are quasi-static and the pressure gradient is roughly unity (head gradient of zero). This is the uppermost zone and is characterized by negative pressures. 2.) Transition Zone where the pressures increase from ambient to zero, are changing relatively rapidly and the pressure gradient is relatively steep (pressure head gradients of 2). The Transition zone is 10 to 15 cm thick. 3.) Positive Pressure Zone where the pressure is positive, the rate of change is slower than in the transition zone and the gradient is flatter (pressure head gradient 1.1 to 1.2). This is the lowest zone in the column. Injection of water causes the pressure to increase and the three zones to move upward. The Transition zone moves at a rate of approximately 0.0002 m/s +/- .00005, according to analyses of pressure profiles. This is the same as the average velocity of the water calculated as volumetric flux/effective porosity =5.4x10-5 m/s/0.28. Strain signals in the range of 10s  were observed with a noise level of generally less than 0.1  (signal to noise ratio of greater than 100) during injection and drainage. The spatial and temporal distributions of strain caused by injection depend on the location of the moving pressure zones. The locations of the different pressure zones were determined from pressure profiles at different times and these data were transferred to strain time series. This showed that strain in the Ambient pressure zone is either unchanged or slightly compressive, whereas strain in Transition zone is tensile and roughly proportional to the pressure change, and strain ranges from tensile to compressive in the Positive Pressure zone. In general, the strain is variable at the top of the Positive Pressure zone, but it appears to be consistently tensile lower in the zone. The spatial distribution of strain causes three distinct stages in the strain times series measured between pairs of CMPI reflectors. The strain is unchanged or slightly compressive during Stage 1, it increases (positive strain is tensile) approximately linearly at a rate of 0.02 to 0.03 μ/s during the Stage 2, and then flattens out in Stage 3. The strain increases again during Stage 4 of the time series. The pressure also changes in stages. It is unchanged during Stage 1 and then increases relatively rapidly at a rate of between 4 and 10 Pa/s during Stage 2 and continues to increase during Stages 3 and 4, but at a rate slightly slower than during Stage 2 (from 2.5 to 3.5 Pa/s). The rates of pressure and strain change are consistent with basic analyses. The rate of pressurization is similar to the calculated velocity of flow in the saturated zone, and this is similar to the measured velocity of the strain increase. The ratio of the pressurization rate and strain rate during Stage 2 (2.5 (Pa/s) /0.03 (μ/s)) is 80 MPa, which is approximately equal to the upper range expected considering the uniaxial compression and the Young’s Modulus of the sand. An interesting effect occurs when the upper surface of the sand becomes saturated. Significant compression (several 10s of ) occurs as the pressure and saturation increase at the upper surface. Compression occurs throughout the column, but the effect is greatest at the top of the column. The rate of compression is fastest slightly before ponding occurs, but it slows markedly and nearly stops when water starts to accumulate at the surface (ponding). This effect reverses when the surface of the sand is drained, resulting in tension throughout the column. The compression caused by this effect can be as large or larger than the tensile strain that accumulated during filling. This effect was unexpected because increasing pressure is normally associated with tensile strain. Nevertheless, this effect was observed consistently in all tests where the pressure changes at the upper surface, including tests where water was injected from below or infiltrated from above. This effect behaves as if the pore pressure at the upper surface of the sand exerts a normal force on the boundary (increasing pore pressure exerts a downward compression on the boundary). The results of these laboratory experiments indicate that CMPI can measure strain caused by fluid pressure changes in the vadose zone with a signal to noise ratio of 100 or more. Injection and drainage cause a strain signal that is complex, but repeatable. The magnitudes of the strain signal are consistent with magnitudes that are expected based on poroelastic calculations using independently measured properties of the sand. These results indicate that the CMPI technique with an optical fiber laminated in a polyester ribbon generates data that represent the strain distribution during hydrologic processes of imbibition and drainage in variably saturated sand. This suggests that distributed strain measurements using CMPI could be a viable approach for evaluating processes in the vadose zone, laying the groundwork for future field implementation.

47 OTHER INSTRUMENTATION↗