Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “polarimeters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Development of land based radar polarimeter processor system

The processing subsystem of a land based radar polarimeter was designed and constructed. This subsystem is labeled the remote data acquisition and distribution system (RDADS). The radar polarimeter, an experimental remote sensor, incorporates the RDADS to control all operations of the sensor. The RDADS uses industrial standard components including an 8-bit microprocessor based single board computer, analog input/output boards, a dynamic random access memory board, and power supplis. A high-speed digital electronics board was specially designed and constructed to control range-gating for the radar. A complete system of software programs was developed to operate the RDADS. The software uses a powerful real time, multi-tasking, executive package as an operating system. The hardware and software used in the RDADS are detailed. Future system improvements are recommended.

Kronke, C. W.↗

Vector magnetic field observations with the Haleakala polarimeter

Several enhancements were recently made to the Haleakala polarimeter. Linear array detectors provide simultaneous resolution over a 3-A wavelength range, with spectral resolution of 40 mA. Optical fibers are now used to carry the intensity-modulated light from the rotating quarter-wave plate polarimeter to the echelle spectrometer, permitting its removal from the spar to a more stable environment. These changes, together with improved quarter-wave plates, reduced systematic errors to a few parts in 10,000 for routine observations. Examples of Stokes profiles and derived magnetic field maps are presented.

Mickey, D. L.↗

Fabrication of optical components for the ultraviolet spectrometer and polarimeter on the Solar Maximum Mission

The Solar Maximum Mission (SMM) satellite was launched in February 1980 into a 573 km high circular orbit. It contains X-ray, UV, and optical instruments for the simultaneous observation of solar flares. The ultraviolet spectrometer and polarimeter (UVSP) is one of these instruments. The objectives of the UVSP require the employment of a raster scanning telescope to study the spatial dynamics of flares, the use of a high resolution spectrometer to select and scan spectral lines for temperature and velocity diagnostics, and the utilization of a polarimeter to measure magnetic fields in the solar transition zone. The present paper has the objective to provide a description of the optical fabrication techniques developed for the instrument. Attention is given to telescope mirrors, metering rods, the Ebert mirror, grating blanks, a four-mirror polarizer, beam splitter assemblies, beam splitter fabrication, deflector mirrors, and shipping containers.

Spencer, R. S.↗

Design of the polarimeter for the Solar Activity Measurements Experiments (SAMEX) vector magnetograph

A design concept developed for a polarimeter on the vector magnetograph of the SAMEX satellite that would be very sensitive to solar vector magnetic fields is described. A description of the Poincare sphere is presented, along with the instrument scientific requirements, to provide an understanding of how the polarimeter design has been selected. It is shown that the design goal of a polarimetric sensitivity of 0.0001 can be achieved in the linear measurements using a hybrid analyzer. It is also noted that the systematic errors that produce linear crosstalk into the circular measurement will require the use of the redundant polarization measurements for in-flight calibrations and corrections of the data.

West, E. A.↗

Bragg crystal polarimeters

A Bragg crystal oriented at 45 deg to an incoming beam of X-rays acts as a polarization analyzer. This crystal geometry preferentially reflects those X-rays that satisfy the Bragg condition and whose electric vectors are perpendicular to the plane defined by the incident and reflected photons. X-rays with electric vectors parallel to this plane of incidence are photoelectrically absorbed. The energy bandwidth of nearly perfect crystals is extremely small, which makes them very inefficient X-ray polarimeters. This limitation is particularly acute for observations of the relatively weak X-ray continuum of stellar sources. The bandwidth can be greatly increased by employing mosaic or ideally imperfect crystals. Mosaic crystals possess a high integrated reflectivity, which results in a large increase in the reflection of continuum radiation. A review of the theory and performance characteristics of crystal polarimeters designed for observations of cosmic X-ray sources is presented.

Silver, E.↗

Study of the polarization dependence of the photoelectric effect in the soft X-ray band - A focal plane photoelectric stellar X-ray polarimeter for the Spectrum-X-Gamma mission

An experimental study of the polarization dependence of the photoelectric effect in cesium iodide in the soft X-ray band was started (Heckler et al., 1989). At a grazing angle of 10 degrees and a photon energy of 2.6 keV, it is found that the photoelectric yield from a thin layer of evaporated cesium iodide varies by 12.4 percent as the polarization vector of the incident X-ray beam is rotated about the line-of-sight. The rotation angle corresponding to the maximum photoyield is displaced by 16 degrees from the normal to the photocathode. This modulation and phase shift are in good agreement with the results recently reported by Fraser, et al. (1989) It is shown that a focal plane stellar X-ray polarimeter based on this photoelectric effect will be substantially more efficient than convential X-ray polarimeters such as those based on either Bragg reflection or scattering from low atomic number targets.

Heckler, A.↗

Solar flare X-ray polarimeter utilizing a large area thin beryllium scattering disk

A model of a solar flare X-ray polarimeter utilizing a large-area thin beryllium scattering disk was developed using Monte Carlo techniques for several classes of solar flares. The solar-flare polarimeter consists of a 30-cm-diam Be disk of about 1/3 of a scattering length thickness, which is surrounded by a cylindrical detector composed of six segmented panels of NaI scintillators, each coupled to 15 photomultiplier tubes. The instrument is sensitive to X-rays from 10 to 100 keV. For a class-M-2 solar flare observed for 10 sec from a balloon at an altitude of 150,000 ft, the minimum detectable polarization at the 99 percent statistical confidence level was found to be 1-6 percent over the energy range 20-100 keV.

Gotthelf, E.↗

Earth Observing Scanning Polarimeter (EOSP), phase B

Evaluations performed during a Phase B study directed towards defining an optimal design for the Earth Observing Scanning Polarimeter (EOSP) instrument is summarized. An overview of the experiment approach is included which provides a summary of the scientific objectives, the background of the measurement approach, and the measurement method. In the instrumentation section, details of the design are discussed starting with the key instrument features required to accomplish the scientific objectives and a system characterization in terms of the Stokes vector/Mueller matrix formalism. This is followed by a detailing of the instrument design concept, the design of the individual elements of the system, the predicted performance, and a summary of appropriate instrument testing and calibration. The selected design makes use of key features of predecessor polarimeters and is fully compatible with the Earth Observing System spacecraft requirements.

Source record↗

On the performance of the scattering and crystal polarimeters for the Spectrum-X-Gamma mission

X-ray scattering from a lithium disk and Bragg reflection from a mosaic graphite crystal can be exploited to measure the linear polarization of radiation emitted from cosmic X-ray sources. The sensitivity is enhanced if the polarimeters are placed at the focus of an X-ray telescope. Such devices form two of the components of the Stellar X-ray Polarimeter experiment scheduled to fly on the Spectrum-X-Gamma mission. The expected on-axis performance of the two components is described based on detailed Monte Carlo simulations. The polarimetry experiment is expected to provide sensitive measurements of linear polarization for many cosmic X-ray sources. The nature and utility of such observations is described for pulsing X-ray sources such as the Crab pulsar and Her X-1.

Elsner, R. F.↗

Imaging proportional counters for the stellar X-ray polarimeter

The xenon-filled IPCs being developed for the Stellar X-ray Polarimeter are described. The requirements placed on the IPCs by the design of the polarimeter are discussed and results on the performance of prototype counters are presented. The design of a prototype of the IPCs is described. Finally, the performance of the prototype is reported. Due to the extremely low count rates encountered in X-ray polarimetry, efficient background rejection is the most critical parameter of the IPCs. Using a background rejection scheme employing anticoincidence and pulse shape discrimination, a rejection efficiency of 99 percent has been achieved for Co-60-induced events over an energy range of 2 to 15 keV while retaining more than 80 percent of the X-ray efficiency.

Watkins, R. B., Jr.↗

Solar maximum mission/ultraviolet spectrometer and polarimeter studies

This final report for NASA Contract No. NAS8-35921 describes various studies performed for the Ultraviolet Spectrometer and Polarimeter (UVSP) experiment, one of several instruments on the Solar Maximum Mission (SMM) satellite which was launched on 14 February 1980. The UVSP consisted primarily of a Gregorian telescope and an Ebert-Fastie spectrometer with a polarimeter that could be inserted into the light path. The spacecraft and most of the instruments, including the UVSP, operated successfully until 23 November 1980, when part of the SMM attitude control system (fine pointing control) failed. The UVSP was then unable to observe the Sun until 18 April 1984, when the SMM was visited by the space shuttle and the attitude control module was replaced by astronauts. The SMM mission ended when the spacecraft reentered the atmosphere of the Earth and was thereby destroyed on 2 December 1989. The topics covered in this report include the following: (1) ultraviolet stellar polarimetry (probably the first such attempted measurement); no polarization as detected and the upper limits, based on the sensitivity as determined by the observed count rate, are rather high; (2) an investigation into the possible position of the UVSP wavelength drive after it became stuck on 26 April 1985; (3) fast timing tests for sit-and-state observations involving one or two detectors; (4) development of computer subroutines to allow the calculation of the component of the SMM spacecraft orbital velocity along the line of sight to the Sun at any desired time during the 1984/1985 period when the UVSP wavelength drive was operating properly; (5) listing of published research papers; (6) description of the UVSP catalog of observations; and (7) description of UVSP calibration report and data users guide.

Henze, William, Jr.↗

Status of the Stellar X-Ray Polarimeter for the Spectrum-X-Gamma mission

The Stellar X-Ray Polarimeter (SXRP) uses the polarization sensitivity of a graphite Bragg crystal and a lithium Thomsom scattering target to measure the polarization of X-rays from astrophysical sources. The SXRP is a focal plane detector for the Soviet-Danish SODART telescopes which will be launched on the Soviet Spectrum-X-Gamma mission. The SXRP will be the third orbiting stellar X-ray polarimeter, and should provide an order of magnitude increase in polarization sensitivity over its predecessors.

Kaaret, P.↗

SXRP - An X-ray polarimeter for the SPECTRUM-X-Gamma mission

The Stellar X-ray Polarimeter (SXRP) is a focal plane instrument which will be flown on the SPECTRUM-X-Gamma mission in 1993. The polarimeter is composed of two separate instruments: the first exploits the dependence on the polarization of the Bragg reflection from a graphite crystal, and of the Thomson scattering from a metallic lithium target. The second instrument makes use of the recently discovered polarization dependence of X-ray photoemission from CsI. The SXRP will permit sensitive measurements of several classes of galactic X-ray sources, such as X-ray pulsars, black-hole candidates and supernova remnants. Moreover, and for the first time, SXRP will be able to perform highly sensitive measurements of the brightest extragalactic sources.

Costa, E.↗

Ultraviolet Spectrometer and Polarimeter (UVSP) catalog of observations. Volume 3: Experiments 63058-99771 (February 1988 - November 1989)

A catalog of a observations (experiments) obtained by the Ultraviolet Spectrometer and Polarimeter (UVSP) on the Solar Maximum Mission (SMM) from Nov. 1980 to Nov. 1989 is provided. The information for each entry includes the time of each observation, the observed position of the Sun, the spacecraft roll angle, the slit used, and instrument parameters such as raster size, pixel spacing, wavelength, polarimeter usage, gate time, etc. The document is split into three volumes: Volume 1 contains experiments 1-30719 (Feb. 1980 - Apr. 1985); Volume 2 contains experiments 30720-63057 (Apr. 1985 - Feb. 1988); and Volume 3 contains experiments 63058-99771 (Feb. 1988 - Nov. 1989).

Henze, William, Jr.↗

Ultraviolet spectrometer and polarimeter (UVSP) catalog of observations. Volume 1: Experiments 1-30719, February 1980 - April 1985

A catalog of observations (experiments) obtained by the Ultraviolet Spectrometer and Polarimeter (UVSP) on the Solar Maximum Mission (SMM) from Feb. 1980 to Nov. 1989 is presented. The information for each entry includes the time of each observation, the observed position of the Sun, the spacecraft roll angle, the slit used, and instrument parameters such as raster size, pixel spacing, wavelength, polarimeter usage, gate time, etc. The document is split into three volumes: Volume 1 contains experiments 1-30719 (February 1980-April 1985); Volume 2 contains experiments 30720-63057 (April 1985-February 1988); and Volume 3 contains experiments 63058-99771 (February l988-November 1989).

Henze, William, Jr.↗

Ultraviolet spectrometer and polarimeter (UVSP) catalog of observations. Volume 2: Experiments 30720-63057, April 1985 - February 1988

A catalog of observations (experiments) obtained by the Ultraviolet Spectrometer and Polarimeter (UVSP) on the Solar Maximum Mission (SMM) from Feb. 1980 to Nov. 1989 is presented. The information for each entry includes the time of each observation, the observed position of the Sun, the spacecraft roll angle, the slit used, and instrument parameters such as raster size, pixel spacing, wavelength, polarimeter usage, gate time, etc. The document is split into three volumes: Volume 1 contains experiments 1-30719 (February 1980-April 1985); Volume 2 contains experiments 30720-63057 (April 1985-February 1988); and Volume 3 contains experiments 63058-99771 (February 1988-November 1989).

Henze, William, Jr.↗

A Polarimeter for SOFIA: Summary of Research

The purpose of this research was to study designs for a far-infrared polarimeter for SOFIA that would greatly surpass the performance of the earlier polarimeter, Stokes, used on the Kuiper Airborne Observatory. Specifically we wished to gain the sensitivity to observe much fainter objects, to provide a choice of passbands, to reduce systematic errors, and to improve the efficiency. All of these objectives were successfully addressed. The gain in sensitivity will be achieved in part by the superior capabilities of SOFIA but to an even greater extent by the incorporation of new-technology detector arrays. We are developing superconducting transition-edge detectors using the "pop-up" design conceived by Dr. Harvey Moseley. The choice of passbands is achieved by providing three alternative optical paths, each with its own spectral filter, half-wave plate, and pupil tens. A new investigation has shown that multiwavelength observations provide an essential feature of far-infrared polarimetry. The principal source of systematic errors in observations of extended objects has been unknown polarization in the reference beams. We have developed a strategy for estimating these errors.

Hildebrand, Roger H.↗

A Focal Plane Stellar X-Ray Polarimeter for SXG

The Stellar X-Ray Polarimeter (SXRP) is the only X-ray polarimeter designed to view astrophysical sources that is currently scheduled to be flown. The SXRP is one of eight astronomical X-ray instruments that intended to be flown at the focal plane of the two SODART large-area metal-foil grazing-incidence X-ray telescopes on the Russian Spectrum-Roentgen-Gamma (SRG) mission. The engineering model of the SXRP was delivered to Russia in February 1994. Construction of the flight model (FM) is complete. The SXRP-FM is currently in storage at the Smithsonian Astrophysical Observatory and will be delivered when required.

Kaaret, P.↗