Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “plug load equipment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

85 records · Page 5

Using Public Participation to Improve MELs Energy Data Collection

Miscellaneous Electric Loads (MELs) have proliferated in the last decade, and comprise an increasing share of building energy consumption. Because of the diversity of MELs and our lack of understanding about how people use them, large-scale data collection is needed to inform meaningful energy reduction strategies. Traditional methods of data collection, however, usually incur high labor and metering equipment expenses. As an alternative, this paper investigates the feasibility of crowdsourcing data collection to satisfy at least part of the data collection needs with acceptable accuracy. This study assessed the reliability and accuracy of crowdsourced data, by recruiting over 20 volunteers (from the 2012 Lawrence Berkeley Lab, Open House event) to test our crowdsourcing protocol. The protocol asked volunteers to perform the following tasks for three test products with increasing complexity - record power meter and product characteristics, identify all power settings available, and report the measured power. Based on our collected data and analysis, we concluded that volunteers performed reasonably well for devices with functionalities with which they are familiar, and might not produce highly accurate field measurements for complex devices. Accuracy will likely improve when participants are measuring the power used by devices in their home which they know how to operate, by providing more specific instructions including instructional videos. When integrated with existing programs such as the Home Energy Saver tool, crowdsourcing data collection from individual homeowners has the potential to generate a substantial amount of information about MELs energy use in homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Field Study of Nonintrusive Load Monitoring Devices and Implications for Load Disaggregation

Evaluations of nonintrusive load monitoring (NILM) algorithms and technologies have mostly occurred in constrained, artificial environments. However, few field evaluations of NILM products have taken place in actual buildings under normal operating conditions. This paper describes a field evaluation of a state-of-the-art NILM product, tested in eight homes. The match rate metric—a technique recommended by a technical advisory group—was used to measure the NILM’s success in identifying specific loads and the accuracy of the energy consumption estimates. A performance assessment protocol was also developed to address common issues with NILM mislabeling and ground-truth comparisons that have not been sufficiently addressed in past evaluations. The NILM product’s estimates were compared to the submetered consumption of eight major appliances. Overall, the product had good performance in disaggregating the energy consumption of the electric water heaters, which included both electric resistance and heat-pump water heaters, but only a fair accuracy with refrigerators, dryers, and air conditioners. The performance was poor for cooking equipment, furnace fans, clothes washers, and dishwashers. Moreover, the product was often unable to detect major loads in homes. Typically, two or more appliances were not detected in a home. At least two dryers, furnace fans, and air conditioners went undetected across the eight homes. On the other hand, the dishwasher was detected in all homes where available or monitored. The key findings were qualitatively compared to those of past field evaluations. Potential areas for improvement in NILM product performance were determined along with areas where complementary technologies may be able to aid in load-disaggregation applications.

47 OTHER INSTRUMENTATION↗

User-Loaded SlipChip for Equipment-Free Multiplexed Nanoliter-Scale Experiments

This paper describes a microfluidic approach to perform multiplexed nanoliter-scale experiments by combining a sample with multiple different reagents, each at multiple mixing ratios. This approach employs a user-loaded, equipment-free SlipChip. The mixing ratios, characterized by diluting a fluorescent dye, could be controlled by the volume of each of the combined wells. The SlipChip design was validated on an {approx}12 nL scale by screening the conditions for crystallization of glutaryl-CoA dehydrogenase from Burkholderia pseudomallei against 48 different reagents; each reagent was tested at 11 different mixing ratios, for a total of 528 crystallization trials. The total consumption of the protein sample was {approx}10 {micro}L. Conditions for crystallization were successfully identified. The crystallization experiments were successfully scaled up in well plates using the conditions identified in the SlipChip. Crystals were characterized by X-ray diffraction and provided a protein structure in a different space group and at a higher resolution than the structure obtained by conventional methods. In this work, this user-loaded SlipChip has been shown to reliably handle fluids of diverse physicochemical properties, such as viscosities and surface tensions. Quantitative measurements of fluorescent intensities and high-resolution imaging were straighforward to perform in these glass SlipChips. Surface chemistry was controlled using fluorinated lubricating fluid, analogous to the fluorinated carrier fluid used in plug-based crystallization. Thus, we expect this approach to be valuable in a number of areas beyond protein crystallization, especially those areas where droplet-based microfluidic systems have demonstrated successes, including measurements of enzyme kinetics and blood coagulation, cell-based assays, and chemical reactions.

59 BASIC BIOLOGICAL SCIENCES↗

Long-Term Carbon Injection Field Test for 90% Mercury Removal for a PRB Unit a Spray Dryer and Fabric Filter

The power industry in the U.S. is faced with meeting regulations to reduce the emissions of mercury compounds from coal-fired plants. Injecting a sorbent such as powdered activated carbon (PAC) into the flue gas represents one of the simplest and most mature approaches to controlling mercury emissions from coal-fired boilers. The purpose of this test program was to evaluate the long-term mercury removal capability, long-term mercury emissions variability, and operating and maintenance (O&M) costs associated with sorbent injection on a configuration being considered for many new plants. Testing was conducted by ADA Environmental Solutions (ADA) at Rocky Mountain Power’s (RMP) Hardin Station through funding provided by DOE/NETL, RMP, and other industry partners. The Hardin Station is a new plant rated at 121 MW gross that was first brought online in April of 2006. Hardin fires a Powder River Basin (PRB) coal and is configured with selective catalytic reduction (SCR) for NOx control, a spray dryer absorber (SDA) for SO2 control, and a fabric filter (FF) for particulate control. Based upon previous testing at PRB sites with SCRs, very little additional mercury oxidation from the SCR was expected at Hardin. In addition, based upon results from DOE/NETL Phase II Round I testing at Holcomb Station and results from similarly configured sites, low native mercury removal was expected across the SDA and FF. The main goal of this project was met—sorbent injection was used to economically and effectively achieve 90% mercury control as measured from the air heater (AH) outlet to the stack for a period of ten months. This goal was achieved with DARCO® Hg-LH, Calgon FLUEPAC®-MC PLUS and ADA Power PAC PREMIUM brominated activated carbons at nominal loadings of 1.5–2.5 lb/MMacf. An economic analysis determined the twenty-year levelized cost to be 0.87 mills/kW-hr, or $15,000/lb Hg removed. No detrimental effects on other equipment or plant operations were observed. The results of this project also filled a data gap for plants firing PRB coal and configured with an SCR, SDA, and FF, as many new plants are being designed today. Another goal of the project was to evaluate, on a short-term basis, the mercury removal associated with coal additives and coal blending with western bituminous coal. The additive test showed that, at this site, the coal additive known as KNX was affective at increasing mercury removal while decreasing sorbent usage. Coal blending was conducted with two different western bituminous coals, and West Elk coal increased native capture from nominally 10% to 50%. Two additional co-benefits were discovered at this site. First, it was found that native capture increased from nominally 10% at full load to 50% at low load. The effect is believed to be due to an increase in mercury oxidation across the SCR caused by a corresponding decrease in ammonia injection when the plant reduces load. Less ammonia means more active oxidation sites in the SCR for the mercury. The second co-benefit was the finding that high ammonia concentrations can have a negative impact on mercury removal by powdered activated carbon. For a period of time, the plant operated with a high excess of ammonia injection necessitated by the plugging of one-third of the SCR. Under these conditions and at high load, the mercury control system could not maintain 90% removal even at the maximum feed rate of 3.5 lb/MMacf (pounds of mercury per million actual cubic feet). The plant was able to demonstrate that mercury removal was directly related to the ammonia injection rate in a series of tests where the ammonia rate was decreased, causing a corresponding increase in mercury removal. Also, after the SCR was refurbished and ammonia injection levels returned to normal, the mercury removal performance also returned to normal. Another goal of the project was to install a commercial-grade activated carbon injection (ACI) system and integrate it with new-generation continuous emissions monitors for mercury (Hg-CEMs) to allow automatic feedback control on outlet mercury emissions. This was accomplished and the plant can now be operated to control carbon injection based on either the overall mercury removal or an outlet mercury emission rate. By integrating these systems, it was determined that the plant could reduce powdered activated carbon consumption, especially at low load, because, at Hardin, native mercury capture increases from less than 20% to about 50% at low load and the carbon injection rate can be decreased accordingly. Currently, the plant is operating to automatically control emissions to below 0.9 lb/TBtu (pounds of mercury per million British thermal units) at carbon loadings of 0.5 to 1.5 lb/MMacf. During the final phase of the Long-Term test, the ACI system was operated by plant personnel. The estimated O&M cost for a single Hg-CEM system is $15,500/yr. The Hg-CEMs performed well throughout the project. This project began shortly after Thermo Fisher first offered the Mercury Freedom System™ on a commercial basis and progressed though several iterations, improvements, and upgrades to the hardware and software. Indeed, there was a ten-fold increase in the precision and accuracy of the units during the course of the project due to several successful upgrades. In their present condition, the Hg-CEMs measure mercury to a precision of about ± 0.05 μg/wscm (micrograms of mercury per wet standard cubic meter of gas), and only require occasional fine-tuning of the calibration coefficients. The quality assurance/quality control (QA/QC) protocol required to keep the units operating at their optimal performance was also developed and perfected during the course of the project. ADA Environmental Solutions (ADA) developed a daily calibration procedure that surpasses the requirements specified in the Clean Air Mercury Rule (CAMR), and a weekly diagnostic program that ensures that the systems are operating properly and receive the necessary maintenance. For the most part, the systems passed the daily, weekly, and quarterly QA/QC requirements as well as four performance verification tests using the Ontario Hydro (O-H) and Sorbent Trap Methods (STM) for the first test and the EPA Method 30A (M30A) procedure for the remaining three. However, some improvements are still necessary before the system can meet all of the requirements. These involve tests that challenge the system with oxidized mercury (Hg+2). These tests could not be passed at Hardin in spite of trying several improvements suggested by ADA or Thermo Fisher.

20 FOSSIL-FUELED POWER PLANTS↗

VersiCharge-SG - Smart Grid Capable Electric Vehicle Supply Equipment (EVSE) for Residential Applications

In his 2011 State of the Union address, President Obama called for one million electric vehicles on the road by 2015 [1]. With large-scale Electric Vehicle (EV) or Plug-in Electric Vehicle (PEV or EV for short) or Plug-in Hybrid Electric Vehicle (PHEV) penetration into the US market, there will be drastic reduction in fossil fuel consumption, thus significantly reducing our dependency on foreign oil [2-6]. There will also be significant reduction on Green House Gas (GHG) emissions and smog in the major US cities [3, 7, 8]. Similar studies have also been done other industrial counties [9]. For the fuel cost, with the home electricity rate around $0.13 per kWh, it would cost about $0.05 per mile for DC operation and $0.03 cents per mile for AC operation. But, assuming 25 miles per gallon for a typical vehicle and $4 per gallon, fossil fuel will cost $0.16 per mile [10]. The overall lifecycle cost of PEVs will be several folds lower than the existing fossil fueled vehicles. Despite the above advantages of the EVs, the current cost of EVSE is not affordable for the average consumer. Presently, the cost of installing state-of-the-art residential EVSE ranges from $1500 to $2500 [11]. Low priced EVSE technology, which is easy to install, and affordable to operate and maintain by an average consumer, is essential for the large-scale market penetration of EVs. In addition, the long-term success of this technology is contingent on the PEVs having minimal excessive load and shift impact on the grid, especially at peak times. In a report [2] published by the Pacific Northwest National Laboratory (PNNL), the exiting electric power generation infrastructure, if used at its full capacity 24 hours a day, would support up to 84% of the nation’s cars, pickup trucks and SUVs for an average daily drive of 33 miles. This mileage estimate is certainly much below what an average driver would drive his/her vehicle per day. Another report [3] by the National Renewable Energy Laboratory (NREL) shows that an increased PEV penetration would significantly increase pressure on the peak generation, if no controlled charging strategy was put in place. Investigations from Oak Ridge National Laboratory (ORNL) show that in many regions, additional power generation facilities must be put in place and operate in evening times to recharge the EVs [12]. By all accounts, large PEV penetration will bring to the power grid enormous challenges due to the excessive and stochastic demand, and can entirely change the peak time distribution and behavior, perhaps, into a bi-modal distribution capable of exhausting primary, secondary and even reserves (spinning or non-spinning). To minimize the infrastructure upgrade costs and risks to the grid, and to ensure that power quality and reliability remain within the set standards, the demand for EV plug-ins must then be controlled and coordinated locally and at regional levels. Novel control techniques must be devised to allow for close collaboration between neighboring plug-in requestors, between neighboring communities, and between these and more central power authorities. The concept of electric drive vehicle is not new. The development of electric vehicle has been around since 19th century [13]. But due to a number of reasons and practical limitations at the time, including lower cost of gasoline compared to electricity, excessive refueling times, and abundance of gasoline, the automobile industry embraced gasoline-powered vehicles worldwide [13]. With the global warming, ever reducing reservoirs of fossil oil around the world and increasing political pressure to reduce the national dependency on foreign oil, the last decade of the 20th century witnessed major technological breakthroughs in Alternative Fueled Vehicle (AFV) technologies, including electric vehicles. With GHG emissions and carbon footprint in the minds of many more consumers and politicians, the first decade of the 21stCentury witnessed more breakthroughs with some real life experimentation and sporadic deployment of these technologies [14]. By many accounts, the second decade of the 21st Century is expected to be the time when mass volume production and popular usage of these AFV technologies, especially EV, will materialize. The current DOE request for proposals recognizes the need for major technological changes to ensure that the above national goal is realizable. Two major challenges have been identified: (1) major reduction in the cost of ownership of EVSEs, and (2) managing additional EV loads in the power grid while maintaining power quality, reliability, and affordability. We note that the two challenges are closely linked – A holistic approach to true lifecycle cost of EVSE ownership will certainly include any taxes and surcharges that can be put in place for major potential investments in the grid, and higher electricity charges in case of more frequent and longer peak periods. From a societal perspective, this cost could also include the lost GDP (computed on a local basis) and revenue for businesses at local and regional levels when the grid is no longer capable of meeting the demand and unexpected outages occur. A typical end-point electrical distribution system delivers power to a residential EVSE from the neighborhood distribution pole, as shown in Fig.1. This pole has a transformer (neighboring step-down transformer) that steps down the utility medium voltage to dual 120VAC single phase (also called 240VAC split phase). This voltage is fed through a meter into the residential load control center. The load control center consists of branch circuit breakers and distributes the power supply within various areas of the residential unit. One of the branch circuits from the load control center feeds EV charging station for the unit. An electric vehicle charger is plugged into the socket of the EV charging station and other end of this charger is connected to the vehicle during charging. Figure 1 illustrates a typical configuration of the power grid. The left side of the figure shows the power grid from the power generation to the neighboring step-down transformer, while the right side of the figure shows multiple EVs with the respective charging stations. The typical step-down transformer has an upper limit representing the maximum load that can be requested from these neighboring houses altogether (typically 24 kW). In case the total load increases beyond the supported limit, the protection system (e.g. a circuit breaker) attached to the step-down transformer gets activated automatically.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Py MILab: Capturing, Analyzing and Storing Test Data

Integrated Computational Materials Engineering (ICME) has recently received widespread attention due to its promises in reducing dependence on physical testing for engineering design by relying on simulation, reducing both time and cost to market for various applications. ICME however requires validated multiscale material models, which is heavily dependent on available test data with full material and test pedigree, including material processing, test and measurement equipment, raw data collection, and analysis methodology and results. Populating searchable information management systems with such rich data sets is often burdensome for data producers, resulting in a lack of findable data for modelers to validate and verify their models. To overcome these cultural barriers to ICME, NASA has developed of various database-integration toolsets that perform both data management activities within the organization’s best practices with additional functionality that relieves the effort of the data producer and promotes adoption of information management system. One such tool currently under development is Py MILab, an automatic framework for automatic capturing, analysis, maintenance, and storage of material test data. Py MILab uses a modular approach for capturing raw data, analyzing the data, and storing the data in a database, interfaced by neutral file structures, to promote plug-and-play capabilities for various analysis types. TMAnalysis is a Python-based tool that performs automatic data reduction and analysis of uniaxial thermomechanical test data. The TMAnalysis toolset can be implemented within the Analysis module of Py MILab, and thus requires a populated neutral file form the Raw Data Module of Py MILab and outputs a Analysis neutral file compatible with the Database Module of Py MILab. TMAnalysis is able to perform automatic segmentation of multistage tests and perform data analysis and reduction, including determination of point-wise properties in tension, compression, and shear, analysis of stress relaxation tests, creep analysis and zone identification, and combination of these stage types for tests with complex loading histories. The TMAnalysis code is accompanied with a graphical user interface (GUI) that allows users to easily analyze test data in bulk, verify the automatic, consistent analysis performed by the backend code, and edit stage segmentation if necessary before producing the output neutral files, ensuring data is properly analyzed and maintained with full traceability.

Data management↗

Design of P-3 Nadir Port

This project details the design and analysis of a structure to replace the interface of the P-3B nadir port with an optimized interface for science installations. A new nadir port plug has been designed to replace the OEM (Original Equipment Manufacturer) plug (Lockheed PN 910169) currently used in Nadir ports 1 and 2 on the NASA P-3B aircraft. The plug consists of a milled frame that can be outfitted with customizable flat plates to meet a broad range of science needs. The frame slides into place using the existing P-3B rail system using a lever and tie-rod assembly. The seal interface will contact the Fuselage skin of the aircraft and consists of a bulb E-seal that is riveted around the perimeter of the frame. The flat plate (20 inches x 31 inches) provides a large profile that can be outfitted based on science mission goals and requirements to attach multiple instruments. This is a significant increase to the aircraft capability. Previously, the OEM plug had to be modified to hold very small plates, windows, or instruments limiting the use of the ports.There were several challenges for this project that included a constrained schedule, lack of historical references, and reverse engineering. The unusually tight schedule for design, manufacture, and install limited potential approaches. In addition, design of a new interface to replace the existing plug, on an aircraft designed in the 1960's by Lockheed for the Navy with little to no documentation, required substantial reverse engineering. In order to accomplish this, a suitable method to determine interface requirements with the aircraft had to be solved. After several iterations, the solution was to implement laser scanning techniques to scan the aircraft and the OEM plug and generate a 3D model to capture the design envelope. The structure is designed to maintain a positive margin of safety when subjected to the inertial, pressure, and aerodynamic load requirements for an external installation on the P-3B, as described in the Wallops' P-3B Design Requirements 548-RQMT-0001 Rev. A . A finite element model is created in FEMAP (Finite Element Modeling And Postprocessing) and is run through NX Nastran solver to analyze the structure. After several iterations of analysis, the structure was enveloped to hold 115 pounds evenly distributed on the plate.

Chance, Monica↗

NASA Tech Briefs, September 2012

Topics covered include: Beat-to-Beat Blood Pressure Monitor; Measurement Techniques for Clock Jitter; Lightweight, Miniature Inertial Measurement System; Optical Density Analysis of X-Rays Utilizing Calibration Tooling to Estimate Thickness of Parts; Fuel Cell/Electrochemical Cell Voltage Monitor; Anomaly Detection Techniques with Real Test Data from a Spinning Turbine Engine-Like Rotor; Measuring Air Leaks into the Vacuum Space of Large Liquid Hydrogen Tanks; Antenna Calibration and Measurement Equipment; Glass Solder Approach for Robust, Low-Loss, Fiber-to-Waveguide Coupling; Lightweight Metal Matrix Composite Segmented for Manufacturing High-Precision Mirrors; Plasma Treatment to Remove Carbon from Indium UV Filters; Telerobotics Workstation (TRWS) for Deep Space Habitats; Single-Pole Double-Throw MMIC Switches for a Microwave Radiometer; On Shaft Data Acquisition System (OSDAS); ASIC Readout Circuit Architecture for Large Geiger Photodiode Arrays; Flexible Architecture for FPGAs in Embedded Systems; Polyurea-Based Aerogel Monoliths and Composites; Resin-Impregnated Carbon Ablator: A New Ablative Material for Hyperbolic Entry Speeds; Self-Cleaning Particulate Prefilter Media; Modular, Rapid Propellant Loading System/Cryogenic Testbed; Compact, Low-Force, Low-Noise Linear Actuator; Loop Heat Pipe with Thermal Control Valve as a Variable Thermal Link; Process for Measuring Over-Center Distances; Hands-Free Transcranial Color Doppler Probe; Improving Balance Function Using Low Levels of Electrical Stimulation of the Balance Organs; Developing Physiologic Models for Emergency Medical Procedures Under Microgravity; PMA-Linked Fluorescence for Rapid Detection of Viable Bacterial Endospores; Portable Intravenous Fluid Production Device for Ground Use; Adaptation of a Filter Assembly to Assess Microbial Bioburden of Pressurant Within a Propulsion System; Multiplexed Force and Deflection Sensing Shell Membranes for Robotic Manipulators; Whispering Gallery Mode Optomechanical Resonator; Vision-Aided Autonomous Landing and Ingress of Micro Aerial Vehicles; Self-Sealing Wet Chemistry Cell for Field Analysis; General MACOS Interface for Modeling and Analysis for Controlled Optical Systems; Mars Technology Rover with Arm-Mounted Percussive Coring Tool, Microimager, and Sample-Handling Encapsulation Containerization Subsystem; Fault-Tolerant, Real-Time, Multi-Core Computer System; Water Detection Based on Object Reflections; SATPLOT for Analysis of SECCHI Heliospheric Imager Data; Plug-in Plan Tool v3.0.3.1; Frequency Correction for MIRO Chirp Transformation Spectroscopy Spectrum; Nonlinear Estimation Approach to Real-Time Georegistration from Aerial Images; Optimal Force Control of Vibro-Impact Systems for Autonomous Drilling Applications; Low-Cost Telemetry System for Small/Micro Satellites; Operator Interface and Control Software for the Reconfigurable Surface System Tri-ATHLETE; and Algorithms for Determining Physical Responses of Structures Under Load.

Source record↗

Research, Development and Demonstration of Micro-CHP Systems for Residential Applications - Phase I

The objective of the Micro-CHP Phase I effort was to develop a conceptual design for a Micro-CHP system including: Defining market potential; Assessing proposed technology; Developing a proof-of-principle design; and Developing a commercialization strategy. TIAX LLC assembled a team to develop a Micro-CHP system that will provide electricity and heating. TIAX, the contractor and major cost-share provider, provided proven expertise in project management, prime-mover design and development, appliance development and commercialization, analysis of residential energy loads, technology assessment, and market analysis. Kohler Company, the manufacturing partner, is a highly regarded manufacturer of standby power systems and other residential products. Kohler provides a compellingly strong brand, along with the capabilities in product development, design, manufacture, distribution, sales, support, service, and marketing that only a manufacturer of Kohler's status can provide. GAMA, an association of appliance and equipment manufacturers, provided a critical understanding of appliance commercialization issues, including regulatory requirements, large-scale market acceptance issues, and commercialization strategies. The Propane Education & Research Council, a cost-share partner, provided cost share and aided in ensuring the fuel flexibility of the conceptual design. Micro-CHP systems being commercialized in Europe and Japan are generally designed to follow the household thermal load, and generate electricity opportunistically. In many cases, any excess electricity can be sold back to the grid (net metering). These products, however, are unlikely to meet the demands of the U.S. market. First, these products generally cannot provide emergency power when grid power is lost--a critical feature to market success in the U.S. Even those that can may have insufficient electric generation capacities to meet emergency needs for many U.S. homes. Second, the extent to which net metering will be available in the U.S. is unclear. Third, these products are typically not designed for use in households having forced hot-air heating, which is the dominant heating system in the U.S. The U.S. market will also require a major manufacturer that has the reputation and brand recognition, low-cost manufacturing capability, distribution, sales, and service infrastructure, and marketing power to achieve significant market size with a previously unknown and unproven product. History has proven time and time again that small-to-medium-size manufacturers do not have the resources and capabilities to achieve significant markets with such products. During the Phase I effort, the Team developed a conceptual design for a Micro-CHP system that addresses key DOE and U.S. market needs: (1) Provides emergency power adequate for critical household loads, with none of the key drawbacks associated with typical, low-cost emergency generators, such as liquid fuel storage, inability to power ''hard-wired'' loads, need to run temporary extension cords for plug loads, manual set up required, susceptibility to overload, and risk of failure due to lack of maintenance and infrequent operation; (2) Requires no special skills to install--plumbers, electricians and HVAC technicians will typically have all necessary skills; (3) Can be used with the major residential fuels in the U.S., including natural gas and propane, and can be easily adapted to fuel oil as well as emerging fuels as they become available; and (4) Significantly reduces household energy consumption and energy costs.

02 PETROLEUM↗

Plug-in Electric Vehicle Interactions with a Small Office Building: An Economic Analysis using DER-CAM

It is generally believed that plug-in electric vehicles (PEVs) offer environmental and energy security advantages compared to conventional vehicles. Policies are stimulating electric transportation deployment, and PEV adoption may grow significantly. New technology and business models are being developed to organize the PEV interface and their interaction with the wider grid. This paper analyzes the PEVs' integration into a building's Energy Management System (EMS), differentiating between vehicle to macrogrid (V2M) and vehicle to microgrid (V2m) applications. This relationship is modeled by the Distributed Energy Resources Customer Adoption Model (DER-CAM), which finds optimal equipment combinations to meet microgrid requirements at minimum cost, carbon footprint, or other criteria. Results derive battery value to the building and the possibility of a contractual affiliation sharing the benefit. Under simple annual fixed payments and energy exchange agreements, vehicles are primarily used to avoid peak demand charges supplying cheaper off-peak electricity to the building during workdays.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integrated Waste Treatment Unit (IWTU) Input Coal Analyses and Off-Gass Filter (OGF) Content Analyses

A full engineering scale Fluidized Bed Steam Reformer (FBSR) system is being used at the Idaho Nuclear Technology and Engineering Center (INTEC) to stabilize acidic Low Activity Waste (LAW) known as Sodium Bearing Waste (SBW). The INTEC facility, known as the Integrated Waste Treatment Unit (IWTU), underwent an Operational Readiness Review (ORR) and a Technology Readiness Assessment (TRA) in March 2014. The IWTU began non-radioactive simulant processing in late 2014 and by January, 2015 ; the IWTU had processed 62,000 gallons of simulant. The facility is currently in a planned outage for inspection of the equipment and will resume processing simulated waste feed before commencing to process 900,000 gallons of radioactive SBW. The SBW acidic waste will be made into a granular FBSR product (carbonate based) for disposal in the Waste Isolation Pilot Plant (WIPP). In the FBSR process calcined coal is used to create a CO2 fugacity to force the waste species to convert to carbonate species. The quality of the coal, which is a feed input, is important because the reactivity, moisture, and volatiles (C,H,N,O, and S) in the coal impact the reactions and control of the mineralizing process in the primary steam reforming vessel, the Denitration and Mineralizing Reformer (DMR). Too much moisture in the coal can require that additional coal be used. However since moisture in the coal is only a small fraction of the moisture from the fluidizing steam this can be self-correcting. If the coal reactivity or heating value is too low then the coal feed-rate needs to be adjusted to achieve the desired heat generation. Too little coal and autothermal heat generation in the DMR cannot be sustained and/or the carbon dioxide fugacity will be too low to create the desired carbonate mineral species. Too much coal and excess S and hydroxide species can form. Excess sulfur from coal that (1) is too rich in sulfur or (2) from overfeeding coal can promote wall scale and contribute to corrosion in process piping and materials, in excessive off-gas absorbent loading, and in undesired process emissions. The ash content of the coal is important as the ash adds to the DMR and other vessel products which affect the final waste product mass and composition. The amount and composition of the ash also affects the reaction kinetics. Thus ash content and composition contributes to the mass balance. In addition, sodium, potassium, calcium, sulfur, and maybe silica and alumina in the ash may contribute to wall-scale formation. Sodium, potassium, and alumina in the ash will be overwhelmed by the sodium, potassium, and alumina from the feed but the impact from the other ash components needs to be quantified. A maximum coal particle size is specified so the feed system does not plug and a minimum particle size is specified to prevent excess elutriation from the DMR to the Process Gas Filter (PGF). A vendor specification was used to procure the calcined coal for IWTU processing. While the vendor supplied a composite analysis for the 22 tons of coal (Appendix A), this study compares independent analyses of the coal performed at the Savannah River National Laboratory (SRNL) and at the National Energy Technology Laboratory (NETL). Three supersacks a were sampled at three different heights within the sack in order to determine within bag variability and between bag variability of the coal. These analyses were also compared to the vendor’s composite analyses and to the coal specification. These analyses were also compared to historic data on Bestac coal analyses that had been performed at Hazen Research Inc. (HRI) between 2004-2011.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analytical Modeling of Biomass Transport and Feeding Systems

The processing of biomass solids in a biorefinery consists of pretreatment, enzyme hydrolysis / concurrent fermentation of sugars to ethanol, product recovery, and drying. Sustainable operation requires a front end that transforms wet solids into a pumpable slurry. Otherwise the biorefinery will suffer unscheduled shut-downs and inefficient operation due to solids that obstruct pumps and other equipment and resist mixing in a bioreactor. Downtime in pioneer biorefineries due to interruptions from materials handling problems has been 50% or more, leading to unsustainable manufacturing processes. This work addresses new technology, predictive computational models, and definition of operational conditions that result in formation of slurries of corn stover at up to 300 g/L using low enzyme loadings (1 to 3 FPU cellulase/g) before the biomass (corn stover) enters the pretreatment step. A team of researchers from Purdue University, Idaho National Laboratory (INL), Forest Concepts, AdvanceBio, Argonne National Laboratory, and DOE BETO have combined their knowledge in agricultural and biological engineering, bioprocess engineering, mechanical engineering, chemical engineering, agricultural economics, materials engineering and enzyme and microbial technology to address the challenge of making lignocellulose flow. This team effort has resulted in the development and validation of conditions that employ low levels of commercial enzyme in an agitated bioreactor to which corn stover pellets are added resulting in formation of slurries at high solids loadings, before pretreatment. This approach overcomes challenges caused by handling of dry, particulate biomass materials at the front end of the biorefinery. The subsequent materials handling issues cause obstruction at pumps, pipes and valves. Formation of high loadings slurries with low yield stress, as reported here, significantly decreases the potential for process interruption and enhances plant operability. Key advances in the knowledge of how slurry formation occurs is reported here and in recently published journal papers. We found that pellets are needed to achieve high solids loading, and that commercial enzymes are effective in forming slurries of corn stover particles from pellets that have not been pretreated. Our work has resulted in models that predict solids behavior for formation of compressed solids and pellets that in turn facilitate slurries made of high concentrations of corn stover particles. A computational model was developed that gives mechanistic insights into properties of particles and mixing process that gives the slurry rheology needed to facilitate pumping. Hence, the corn stover may be pumped into a pretreatment reactor in place of auguring in solids against high pressure which is a root cause of interruptions at the front end of a biorefinery. Subsequent mixing in enzyme and microbial bioreactors results in conversion of lignocellulose to sugars in a biorefinery in agitated bioreactors, with flows in and out of the vessels being less likely to be interrupted due to plugging or materials handling problems. The obtained data coupled to process models, techno-economic assessment (TEA) and Life Cycle Analysis (LCA) were used to assess whether this approach is practical. These results are based on a foundation of laboratory characterization and pilot runs. The NREL biochemical sugar model was utilized to carry out techno-economic analysis of enzyme catalyzed liquefaction followed by enzyme hydrolysis. The minimum sugar selling price was between 17.5 and 18.3 ¢/pound or about the same as calculated by the NREL model for dilute acid pretreatment followed by enzyme hydrolysis. Life cycle analysis (LCA) based on Argonne’s Greet Model showed the enzyme catalyzed route had the lowest greenhouse gas emissions of the three combinations studied (i.e., enzyme, enzyme mimetic, and enzyme + mimetic combined). GHG emissions for enzyme-based corn stover liquefaction step, alone, were about 21 g CO 2 -equivalent/kg of liquefied slurry. We believe this approach will further enhance operability of a pioneer biorefinery, and bring large-scale conversion of lignocellulosic biomass to low carbon footprint biofuels closer to implementation.

09 BIOMASS FUELS↗

Idling Reduction for Long-Haul Trucks: An Economic Comparison of On-Board and Wayside Technologies

Reducing the idling of long-haul heavy-duty trucks has long been recognized as a particularly low-hanging fruit of fuel efficiency and emissions reduction. The displacement of about 10 hours of diesel idling every day, for most days of the year, for as many as a million long-haul trucks has very clear benefits. This report considers the costs and return on investment (ROI) for idling reduction (IR) equipment for both truck owners and electrified parking space (EPS) equipment owners. For the truck owners, the key variables examined are idling hours to be displaced (generally 1,000 to 2,000 hours per year) and the price of fuel ($0 to $5/gal). The ideal IR option would provide complete services in varied climates in any location and offer the best ROI on trucks that log many idling hours. For trucks that have fewer idling hours, options with a fixed cost per hour (i.e., EPS) might be most attractive if they were available to all, or even most, truck drivers. EPS, however, is particularly cost effective for trucks on prescribed routes with a need for regular, extended stops at terminals. (EPS is also called truck stop electrification, or TSE.) The analysis shows that all IR options save money when fuel costs more than $2/gal. For trucks requiring bunk heat, a simple heater (plug-in or diesel) is almost always the most costeffective way to provide heat, even if the truck is equipped with an auxiliary power unit (APU) or is parked at a single-system EPS location. For trucks requiring bunk air-conditioning, the use of single-system EPS is most cost effective for those logging fewer idling hours. Even for trucks with higher idling hours, the cost of EPS may be about the same as that for on-board air-conditioning. Clearly, trucks’ locations and seasonal factors—and the availability of EPS— are significant in the choice of “best fit” IR equipment for truck owners. This report also considers costs and payback for owners of EPS infrastructure. An industry that 5 years ago had at least five players has been narrowed to two companies—one in single-system EPS (IdleAir) and the other in dual-system EPS (Shorepower Technologies). Use of EPS by truck drivers has not met initial expectations for a variety of reasons. One area where EPS has particular promise, however, is in the cost-effective provision of reliable air-conditioning. This analysis is focused strictly on cost and fuel savings; it does not consider the important benefits of reduced emissions (i.e., greenhouse gases and criteria pollutants). It is important to note that all IR options provide some emissions benefits. Even where an IR option may not have a rapid ROI, the emissions-reduction benefit may be considerable. Finally, as the U.S. Environmental Protection Agency (EPA) and the U.S. Department of Transportation’s National Highway Traffic Safety Administration (NHTSA) set stricter standards to reduce greenhouse gas emissions and improve the fuel efficiency of medium- and heavy-duty vehicles, the emissions benefits of IR strategies will become increasingly important.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗