Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pixel detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Measurement of the fractional radiation length of a pixel module for the CMS Phase-2 upgrade via the multiple scattering of positrons

High-luminosity particle collider experiments such as theones planned at the High-Luminosity Large Hadron Collider requireever-greater vertexing precision of the tracking detectors,necessitating reductions in the material budget of the detectors.Traditionally, the fractional radiation length (x/X$_{0}$) ofdetectors is either estimated using known properties of theconstituent materials, or measured in dedicated runs of the finaldetector. In this paper, we present a method of direct measurementof the material budget of a CMS prototype module designed for thePhase-2 upgrade of the CMS detector using a 40–65 MeV positronbeam. A total of 630 million events were collected at the PaulScherrer Institut PiE1 experimental area using a three-planetelescope consisting of the prototype module as the central plane,surrounded by two MALTA monolithic pixel detectors. Fractionalradiation lengths were extracted from scattering angle distributionsusing the Highland approximation for multiple scattering. Astatistical technique recovered runs suffering from triggerdesynchronisation, and several corrections were introduced tocompensate for local inefficiencies related to geometric and beamshape constraints. Two regions of the module were surveyed andyielded average x/X$_{0}$ values of (0.72 ± 0.05)% and(0.95 ± 0.09)%, which are compatible with empirical estimatesfor these regions computed from known material properties of 0.753%and 0.892%, respectively. Two types of higher-granularity maps ofthe fractional radiation length were produced, subdivided eitherinto rectangular regions of uniform size, or polygonal-shapedregions of uniform material composition. The results bode well forthe CMS Phase-2 upgrade modules, which will play a key role in theminimisation of the material of the upgraded detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Predicting Missing Regions in Charged Particle Tracks Using a Sparse 3D Convolutional Neural Network

The 2x2 Demonstrator is a prototype of ND-LAr, the liquid argon time-projection chamber of the Deep Underground Neutrino Experiment’s Near Detector complex. Both the 2x2 Demonstrator and ND-LAr are modular detectors that will have pixelated charge readouts and inactive regions wherein there is no sensitivity to charge deposition and light signals that arise from charged particle interactions with liquid argon. In the 2x2, these inactive regions are located in between the active detector modules, which introduces the challenge of inferring what charge signals ought to look like in these regions. This study explores the use of a Sparse 3D Convolutional Neural Network (ConvNet) to infer missing regions in charged particle tracks. Hits corresponding to energy depositions are voxelized into a three-dimensional grid for each track. Voxels that fall into predefined inactive regions are removed to simulate the lack of detector output. The model is trained to infer the topology of the missing track voxels, with the ultimate goal of inferring the missing charge or energy values in these voxels as well. Results indicate that this approach shows promise in prediction of missing track regions with some accuracy.

Utaegbulam, Hilary↗

An extreme thermal cycling reliability test of ATLAS ITk Strips barrel modules

At the end of Run 3 of the Large Hadron Collider (LHC), the accelerator complex will be upgraded to the High-Luminosity LHC (HL-LHC) in order to increase the total amount of data provided to its experiments. To cope with the increased rates of data, radiation, and pileup, the ATLAS detector will undergo a substantial upgrade, including a replacement of the Inner Detector with a future Inner Tracker, called the ITk. The ITk will be composed of pixel and strip sub-detectors, where the strips portion will be composed of 17,888 silicon strip detector modules. During the HL-LHC running period, the ITk will be cooled and warmed a number of times from about -35°C to room temperature as part of the operational cycle, including warm-ups during yearly shutdowns. To ensure ITk Strips modules are functional after these expected temperature changes, and to ensure modules are mechanically robust, each module must undergo ten thermal cycles and pass a set of electrical and mechanical criteria before it is placed on a local support structure. This paper describes the thermal cycling Quality Control (QC) procedure, and results from the barrel pre-production phase (about 5% of the production volume). Additionally, in order to assess the headroom of the nominal QC procedure of 10 cycles and to ensure modules don't begin failing soon after, four representative ITk Strips barrel modules were thermally cycled 100 times — this study is also described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Results from a synthetic model of the ITER XRCS-Core diagnostic based on high-fidelity x-ray ray tracing

A high-fidelity synthetic diagnostic has been developed for the ITER core x-ray crystal spectrometer diagnostic based on x-ray ray tracing. This synthetic diagnostic has been used to model expected performance of the diagnostic, to aid in diagnostic design, and to develop engineering tolerances. The synthetic model is based on x-ray ray tracing using the recently developed xicsrt ray tracing code and includes a fully three-dimensional representation of the diagnostic based on the computer aided design. The modeled components are: plasma geometry and emission profiles, highly oriented pyrolytic graphite pre-reflectors, spherically bent crystals, and pixelated x-ray detectors. Plasma emission profiles have been calculated for Xe 44+ , Xe 47+ , and Xe 51+ , based on an ITER operational scenario available through the Integrated Modelling & Analysis Suite database, and modeled within the ray tracing code as a volumetric x-ray source; the shape of the plasma source is determined by equilibrium geometry and an appropriate wavelength distribution to match the expected ion temperature profile. All individual components of the x-ray optical system have been modeled with high-fidelity producing a synthetic detector image that is expected to closely match what will be seen in the final as-built system. Particular care is taken to maintain preservation of photon statistics throughout the ray tracing allowing for quantitative estimates of diagnostic performance.

47 OTHER INSTRUMENTATION↗

Image Alignment and Flat-Field Correction of Film and Computed Radiography Images on the LLNL Flash Testbed

Computed radiography (CR) imaging plates and film are used in HEAF firing tanks and in the NDE group. The imaging plates allow for the creation of high-resolution digital images with flash X-ray (FXR). A typical treatment of flash X-ray radiographs is flat-field correction, where the image from an experiment is normalized by a “flat-field” or “bright-field” image. This flat-field image is taken in an identical configuration to the experimental image, but without the object or experiment in the field of view (FOV). This treatment reduces spatial effects from the FXR spot size and detector misalignment, as each pixel value in the corrected image represents a ratio of collected radiation with the object in FOV to the collected radiation without the object in FOV. One challenge in the creation of a corrected image is the misalignment of the CR plate or film pack between capturing the flat-field image and the experimental image. Fiducial structures can remedy this issue. Small (3.18mm) stainless steel ball bearings serve as good fiducial structures due to their small size and high radiographic contrast. Spheres are view-agnostic geometry, always presenting a circular cross section no matter the orientation. This process was developed for images from the flash X-ray testbed. The flash testbed was used to compare the X-ray transmission at different thicknesses of aluminum and copper step wedges. Each step wedge section is a rectangular shape, so evaluation is made much simpler if the rectangles are not rotated with respect to the image. This alignment process aligns the object and flat-field images together and leaves the rectangles of each step aligned with the image.

36 MATERIALS SCIENCE↗

Characterization of EJ-270 and Ce-doped LiCAF scintillators for the development of high-rate neutron reflectometer detectors

The Second Target Station of the Spallation Neutron Source at Oak Ridge National Laboratory is anticipated to provide a neutron source with ∼20 times increase in peak brightness than the First Target Station. The neutron reflectometers currently in operation at the First Target Station need to be upgraded due to the increased neutron flux. A prototype neutron detector module based upon a pixelated scintillator array readout by silicon photomultipliers is being developed to address the high-rate challenge faced with future neutron reflectometer instruments at the Second Target Station. Two types of scintillator materials were considered for this detector development, i.e., 6 Li-loaded EJ-270 plastic scintillator and Ce-doped LiCAF single crystal. This paper reports the scintillator characterization results, including light yield, pulse shape discrimination performance, capability to detect thermal neutrons in a high γ-ray field, and γ-ray sensitivity. The number of photons produced per neutron capture by EJ-270 and LiCAF:Ce was measured to be 2176 ± 91 and 2651 ± 108, respectively. EJ-270 demonstrated a good capability to discriminate between neutrons and γ-rays by employing the commonly used charge comparison method (figure-of-merit: 1.13 ± 0.01 for an energy cut of 292–426 keVee) and a reasonable performance when using the time-over-threshold techniques; however, no discrimination was observed from LiCAF:Ce regardless of the pulse shape discrimination approaches utilized, making pulse height discrimination necessary for LiCAF:Ce to differentiate between neutrons and γ-rays. Both EJ-270 and LiCAF:Ce exhibited an acceptable capacity to detect thermal neutrons at high exposure rates up to approximately 584 mR/h. Furthermore, the γ-ray sensitivities measured with a 60 Co source at an exposure rate of around 1145 mR/h were determined to be (6.11 ± 0.87) × 10 −6 and (7.64 ± 1.08) × 10 −7 for EJ-270 and LiCAF:Ce, respectively.

EJ-270↗

Evaluation of the absolute single-photon detection efficiency of HRPPD

Pixelated High Rate Picosecond Photon Detectors (HRPPDs) by Incom Inc. are promising photosensors for use in Ring Imaging CHerenkov (RICH) detectors, where a high gain, sub-mm position resolution and sub-100ps timing resolution are required in a single photon mode. Quantum Efficiency (QE) has been measured for the first batch of EIC HRPPDs both by Incom and EIC research groups at Jefferson Lab and Brookhaven Lab, with peak values at ∼365 nm typically exceeding 30%. Furthermore, in this study, we present a first direct measurement of Photon Detection Efficiency being equal to (17.1 ± 0.1 [stat] ± 0.3 [sys])% at 398.6 nm, for a pixel near the center of HRPPD, in a photoelectron pulse counting mode using a picosecond diode laser. HRPPD QE at the same spot and at the same wavelength was evaluated to be (24.4 ± 0.1 [stat] ± 0.3 [sys])%, leading to a Collection Efficiency estimate of (70.3 ± 1.6)%, which is consistent with the expectations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Opportunities and challenges to study solar neutrinos with a Q-Pix pixel readout

The study of solar neutrinos presents significant opportunities in astrophysics, nuclear physics, and particle physics. However, the low-energy nature of these neutrinos introduces considerable challenges to isolate them from background events, requiring detectors with low-energy threshold, high spatial and energy resolutions, and low data rate. We present the study of solar neutrinos with a kiloton-scale liquid argon detector located underground, instrumented with a pixel readout using the Q-Pix technology. We explore the potential of using volume fiducialization, directional topological information, light signal coincidence, and pulse-shape discrimination to enhance solar neutrino sensitivity. We find that discriminating neutrino signals below 5 MeV is very difficult. However, we show that these methods are useful for the detection of solar neutrinos when external backgrounds are sufficiently understood and when the detector is built using low-background techniques. When building a workable background model for this study, we identify 𝛾 background from the cavern walls and from capture of 𝛼 particles in radon decay chains as both critical to solar neutrino sensitivity and significantly underconstrained by existing measurements. Finally, we highlight that the main advantage of the use of Q-Pix for solar neutrino studies lies in its ability to enable the continuous readout of all low-energy events with minimal data rates and manageable storage for further off-line analyses.

multi-purpose particle detectors↗

Neutron detector development for high-rate neutron reflectometry at the Second Target Station of Oak Ridge National Laboratory

The Second Target Station (STS) at the Oak Ridge National Laboratory Spallation Neutron Source (SNS) is expected to produce a neutron source that is the brightest in the world, having a significantly higher peak brightness compared to the First Target Station (FTS), where the reflectometry instruments already fall short of being able to handle the highest available flux by a factor of ~100. The neutron reflectometers at the SNS FTS are not suitable for the reflectometers planned for the SNS STS because of its unprecedentedly high peak brightness and the already limited capabilities of these instruments at high count rates. Furthermore, the high rate instruments that are now under development are expected to underperform with regard to gamma sensitivity, meaning that signal-to-noise will be reduced and they will be unable to measure weaker reflectance phenomena in the presence of the significant prompt gamma flash at SNS. To address these challenges, we conducted research to advances associated instruments, techniques, and capabilities for the SNS STS reflectometers. More specifically, we investigated the development of a scalable, 2-D positive-sensitive, pixelated, scintillator-based neutron detector module based on a newly developed scintillator. The work has potential for impact on future neutron reflectometry instruments and neutron science performed at the SNS STS. In particular, the improved background rejection capability of the developed detector could extend the available experimental dynamic Q range, allowing it to measure weak reflectance phenomena.

reflectometry, radiation instrumentation, neutron ↗

First Direct-Detection Results on Sub-GeV Dark Matter Using the SENSEI Detector at SNOLAB

Here, we present the first results from a dark matter search using six Skipper-CCDs in the SENSEI detector operating at SNOLAB. We employ a bias-mitigation technique of hiding approximately 46% of our total data and aggressively mask images to remove backgrounds. Given a total exposure after masking of 100.72 gram-days from well-performing sensors, we observe 55 two-electron events, 4 three-electron events, and no events containing 4–10 electrons. The two-electron events are consistent with pileup from one-electron events. Among the 4 three-electron events, 2 appear in pixels that are likely impacted by detector defects, although not strongly enough to trigger our “hot-pixel” mask. We use these data to set world-leading constraints on sub-GeV dark matter interacting with electrons and nuclei.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scalable dark matter searches using integrated photonics

Dark matter (DM) with masses of order an electronvolt or below can have a nonzero coupling to electromagnetism while being compatible with cosmological observations. In these models, the ambient DM behaves as a new classical source in Maxwell’s equations, which can excite potentially detectable electromagnetic (EM) fields in the laboratory. We propose a new integrated-photonics–based approach to search for dark matter candidates in the 0.1–few eV mass range. This approach offers a wide range of wavelength-scale devices like resonators and wave guides that are readily fabricated in large quantities, enabling a scalable and novel search. In particular, we demonstrate that refractive index-modulated resonators, such as etched/grooved microrings, or patterned slabs, support EM modes with efficient coupling to DM. When excited by DM, these modes are read out by coupling the resonators to a wave guide that terminates on a micron-scale–sized single photon detector, such as a single pixel of a low-noise charge-coupled device or a superconducting nanowire. We then estimate the sensitivity of this experimental concept in the context of axionlike particle and dark photon models of DM, demonstrating that nanophotonic confinement and scalability can extend dark matter sensitivity into previously unexplored parameter space.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The 4D Camera: An 87 kHz Direct Electron Detector for Scanning/Transmission Electron Microscopy

We describe the development, operation, and application of the 4D Camera—a 576 by 576 pixel active pixel sensor for scanning/transmission electron microscopy which operates at 87,000 Hz. The detector generates data at ~480 Gbit/s which is captured by dedicated receiver computers with a parallelized software infrastructure that has been implemented to process the resulting 10–700 Gigabyte-sized raw datasets. The back illuminated detector provides the ability to detect single electron events at accelerating voltages from 30 to 300 kV. Through electron counting, the resulting sparse data sets are reduced in size by 10--300× compared to the raw data, and open-source sparsity-based processing algorithms offer rapid data analysis. The high frame rate allows for large and complex scanning diffraction experiments to be accomplished with typical scanning transmission electron microscopy scanning parameters.

47 OTHER INSTRUMENTATION↗

Results from the DUNE ND-LAr 2x2 Demonstrator Run 2

The Deep Underground Neutrino Experiment (DUNE) is a cutting-edge, long-baseline experiment under construction in the United States, based on large liquid-argon time projection chambers (LArTPCs). The DUNE Near Detector LArTPC (ND-LAr) will employ a novel modular architecture using a pixelated LArPix charge readout. To validate this design and characterize detector response, the 2×2 demonstrator—an array of eight optically isolated LArTPC modules—was deployed at Fermilab in 2024. During winter 2025, the 2x2 demonstrator was operated for a second data-taking campaign (Run 2) with the aim of studying the low-energy response of the detector. Run 2 focused on calibration and response studies using a suite of deployed radioactive sources. Gamma sources (²²Na, ⁶⁰Co, and ⁸⁸Y) were used to probe module-to-module performance variations, energy resolution, and calibrations. Neutron sources (AmBe and a pulsed neutron generator) enabled studies of neutron interactions in liquid argon, including inelastic scatters and neutron capture signals, relevant for low-energy backgrounds and detector modeling. In addition, the detector was doped with ²²⁰Rn, providing Bi–Po coincidence signals that allow precise calibration of the charge and scintillation response. This poster will present results from these calibration campaigns. These studies provide critical validation of the ND-LAr modular LArTPC concept and inform calibration and reconstruction strategies for the full DUNE near detector.

Mora-Lepin, Luis [Florida State U.] (ORCID:0000000↗

Understanding Formation of Irradiation-Induced Defects through 4D-STEM, Electron Tomography, and WBDF-STEM

A major challenge in advancing nuclear materials for next-generation fission and proposed fusion reactors is to comprehensively understand the formation of irradiation-induced defects. Here it is essential to correlate the evolution of irradiation-induced defects and the degradation of mechanical properties, as they collectively dictate the material's lifespan and ensure nuclear safety. Scanning transmission electron microscopy (STEM) based techniques have emerged as indispensable tools for irradiation-induced defect characterization, offering high spatial resolution imaging and chemical analysis, such as electron energy loss spectroscopy (EELS) and energy dispersive X-ray spectroscopy (EDXS). These techniques have been effectively used to obtain an atomic-scale view of the defect structure. Recent advances in electron microscopy, particularly in 4D-STEM, offer detailed insight into microstructural evolution by capturing full 2D diffraction patterns at every pixel position. Using high-speed direct electron detectors, this technology generates a four-dimensional dataset, overcoming the limitations of traditional STEM imaging.

36 MATERIALS SCIENCE↗

Evaluation of an event-driven 3FI ASIC for spectroscopic X-ray detection with synchrotron radiation

The novel design and evaluation on the NSLS-II beamline of the 3FI application-specific integrated circuit (ASIC) bump-bonded to a simple, planar, 2D segmented silicon sensor are presented. The ASIC was developed for full-field fluorescence spectral X-ray imaging (3FI). It is a small-scale prototype that features a square array of 32 × 32 pixels, and the size of the pixels is 100 µm × 100 µm. The ASIC was implemented in a 65 nm CMOS integrated circuit fabrication process. Each pixel incorporates a charge-sensitive amplifier, a shaping filter, a discriminator, a peak detector and a sample-and-hold circuit, allowing detection of events and storage of signal amplitudes. The system operates in a frameless event-driven readout mode, outputting analog values for threshold-triggered events, allowing high-speed multi-element X-ray fluorescence data acquisition. The 3FI ASIC achieves per-channel spectrometric performance at a power consumption of only 200 µW per pixel, with nearly all dissipation confined to the analog front-end. An energy resolution is measured at the level of 308 eV full width at half-maximum (FWHM) at 8.04 keV (Cu Kα), and 138 eV FWHM at 3.69 keV (Ca Kα). This per-pixel capability makes the prototype suitable for in situ trace element microanalysis in biological and environmental studies. Moreover, the frameless architecture of the detector is designed to address limitations of conventional X-ray fluorescence microscopy, which typically requires mechanical scanning, by enabling continuous high-throughput data acquisition in future full-field implementations.

47 OTHER INSTRUMENTATION↗

Beam test performance studies of CMS Phase-2 Outer Tracker module prototypes

A new tracking detector will be installed as part of thePhase-2 upgrade of the CMS detector for the high-luminosity LHC era.This tracking detector includes the Inner Tracker, equipped withsilicon pixel sensor modules, and the Outer Tracker, consisting ofmodules with two parallel stacked silicon sensors. The Outer Trackerfront-end ASICs will be able to correlate hits from chargedparticles in these two sensors to perform on-module discriminationof transverse momenta (p$_{T}$). The p$_{T}$information is generated at a frequency of 40 MHz and will be usedin the Level-1 trigger decision of CMS. Prototypes of theso-called 2S modules were tested at the Test Beam Facility at DESYHamburg between 2019 and 2020. These modules use the finalfront-end ASIC, the CMS Binary Chip (CBC), and for the firsttime the Concentrator Integrated Circuit (CIC), optical readoutand on-module power conversion. In total, seven modules were tested,one of which was assembled with sensors irradiated with protons. Animportant aspect was to show that it is possible to read out modulessynchronously. A cluster hit efficiency of about 99.75 % wasachieved for all modules. The CBC p$_{T}$ discriminationmechanism has been verified to work together with the CIC andoptical readout. The measured module performance meets therequirements for operation in the upgraded CMS tracking detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Deuteron Evaporation from N = Z Compound Nuclei

Deuteron evaporation was observed from the N = Z compound nuclei 52 Fe ⋆ , 56 Ni ⋆ , and 64 Ge ⋆ in an experiment conducted at Argonne National Laboratory, USA. The experiment included a novel combination of two highly pixelated double-sided Si-strip detectors inside the Microball chargedparticle detection array, allowing for unequivocal discrimination of evaporated deuterons from protons and α particles. In conjunction with the Gammasphere array, Neutron Shell, and additional ancillary detectors, decay paths into various residual nuclei were investigated. The study provides insights into the competition of deuteron vs. proton-neutron evaporation as a function of available excitation energy and populated angular momentum. Results are interpreted using a statistical evaporation formalism for multiple subsequent particle emissions. The decisive factor in the comparison appears to be the available excitation energy in the residual system, with single nucleon evaporation preferred over deuteron evaporation for higher excitation energies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗