Interferometric observations of an artificial satellite.

Very-long-baseline interferometric observations of radio signals from the TACSAT synchronous satellite, even though extending over only 7 hours, have enabled an excellent orbit to be deduced. Precision in differential delay and delay-rate measurements reached 0.15 nanosecond and 0.05 picosecond per second, respectively. The results from this initial three-station experiment demonstrate the feasibility of using the method for accurate satellite tracking and for geodesy.

Preston, R. A.↗

University of Hawaii Lure Observatory

The University of Hawaii's Institute for Astronomy is currently constructing a lunar laser ranging observatory at the 3050-meter summit of Mt. Haleakala, Hawaii. The Nd YAG laser system to be employed provides three pulses per second, each pulse being approximately 200 picoseconds in duration. The energy contained in one pulse at 5320 A lies in the range from 250 to 350 millijoules. Details of observatory construction are provided together with transmitter design data and information concerning the lunastat, the feed telescope, the relative pointing system, the receiver, and the event timer system.

Carter, W. E.↗

Heating of solid targets with laser pulses

Analytical and numerical solutions to the heat-conduction equation are obtained for the heating of absorbing media with pulsed lasers. The spatial and temporal form of the temperature is determined using several different models of the laser irradiance. Both surface and volume generation of heat are discussed. It is found that if the depth of thermal diffusion for the laser-pulse duration is large compared to the optical-attenuation depth, the surface- and volume-generation models give nearly identical results. However, if the thermal-diffusion depth for the laser-pulse duration is comparable to or less than the optical-attenuation depth, the surface-generation model can give significantly different results compared to the volume-generation model. Specific numerical results are given for a tungsten target irradiated by pulses of different temporal durations and the implications of the results are discussed with respect to the heating of metals by picosecond laser pulses.

Bechtel, J. H.↗

Space-resolved spectra of laser-produced plasmas in the XUV

The design and imaging properties of an XUV (extreme ultraviolet, 200-550 A) normal-incidence slitless spectrograph, the spectrum obtained from laser-generated plasmas, and the monochromatic plasma images are described. The electron temperature of the plasmas, electron density as a function of position in the plasma, and the thickness of material penetrated by the laser pulse are determined. Elements from Z = 6 to Z = 28 were investigated, in addition to Nb. Secondary plasma-emission regions were observed 2-3 mm from the flat (thick or thin) targets. Time-integrated photographs of the expanding plasmas were recorded by the slitless spectrograph. A technique for obtaining time-resolved images of the plasmas in picosecond time intervals is proposed, and problems in the design of a stigmatic XUV spectrograph are discussed.

Feldman, U.↗

A sub-nanosecond CCD

A 32-cell silicon n-channel PCCD was fabricated and tested for charge transfer efficiency versus transfer time. A charge transfer time of 550 picoseconds with a 0.9998 transfer efficiency was obtained when operated in the uni-phase mode. These conditions correspond to an operating rate of 900 MHz when operated as an analog data or digital device.

Chan, Y. T.↗

Photomultiplier tube development for the 1.06 micrometer wavelength

High speed, electrostatic photomultipliers were developed for use in 400 megabit laser communication systems operating at the 1.06 micron wavelength. A high performance, electrostatic III-V photocathode PMT was shown in communication system tests to perform competitively with solid state and avalanche photodiodes. Signal-induced noise and III-V cathode stability were identified as remaining technical problems while cathode quantum efficiencies of or = 5% at 1.06 micron and 320 picosecond rise and fall time pulse performance were achieved.

Enck, R. S., Jr.↗

Characterization of gigahertz (GHz) bandwidth photomultipliers

The average impulse response, root-mean-square times jitter as a function of signal level, single photoelectron distribution, and multiphotoelectron dark-count distribution have been measured for two static crossed-field and five electrostatic photomultipliers. The optical signal source for the first three of these tests was a 30 picosecond mode-locked laser pulse at 0.53 micron. The static crossed-field detectors had 2-photoelectron resolution, less than 200 ps rise times, and rms time jitters of 30 ps at the single photoelectron level. The electrostatic photomultipliers had rise times from 1 to 2.5 nanoseconds, and rms time jitters from 160 to 650 ps at the same signal level. The two static crossed-field photomultipliers had ion-feedback-generated dark pulses to the 50-photoelectron level, whereas one electrostatic photomultiplier had dark pulses to the 30-photoelectron level.

Abshire, J. B.↗

Systems for measuring response statistics of gigahertz bandwidth photomultipliers

New systems have been developed for measuring the average impulse response, the pulse-height spectrum, the transit-time statistics as a function of signal level, and the dark-count spectrum of gigahertz bandwidth photomultipliers. Measurements showed that the 0.53 microns pulse used as an optical test source had a 30 picoseconds and less than 70 ps pulse width. Calibration data showed the system resolution to be less than 20 ps for root mean square transit-time measurements. Test data for a static crossed-field photomultiplier showed 2-photoelectron resolution and less than 30-ps time jitter over the 1- to 100-photoelectron range.

Abshire, J. B.↗

Time transfer via satellite-link radio interferometry

Very long baseline interferometry using natural radio sources was investigated as a possible time transfer method. Antennas were linked using a synchronous communications satellite instead of the customary independent frequency standards and tape recorders. A successful preliminary time transfer was performed using a wideband data link that was accurate at the 100 nanosecond level, and frequency standards were compared to a part in 10 to the minus thirteenth power over a 24 hour period using a phase coherent satellite link. The narrow band phase coherent link method is potentially capable of timing accuracy of 10 picoseconds, and frequency comparison accuracy of 10 to the minus sixteenth power, and is in addition economical of spectrum usage.

Knowles, S. H.↗

Circular Scan Streak Tube Development

A streak tube having circular scan was designed, built and tested. Continuous circular scan, easily derived from out of phase sine waves applied to the conventional deflection plates, permits the timing of pulses traveling long baselines. At the tube's output a circular array of 720 elements is scanned to provide 30 to 40 picosecond resolution. Initial difficulties with electron bombarded silicon arrays were circumvented by using microchannel plates within the streak tube to provide the needed electronic amplification and digital sensitivity and coupling the 720 element arrays to the electron beam by means of a phosphor on a fiber optics. Two ceramic body tubes with S-20 photocathodes were tested and delivered.

Nevin, S.↗

Gigahertz analog modulation and differential delay of GaAlAs lasers - Temperature and current behavior

Gigahertz analog modulation characteristics of broad-area commercially available GaAlAs lasers have been investigated as a function of temperature and current in the vicinity of the upper frequency limit, where the resonance phenomena occur. The optimum temperature for small-signal amplitude modulation was found to be around -15 C for our particular broad-stripe geometry double-heterostructure laser. The Q was found to increase by a factor of 2 and the bandwidth by about 2%; the external quantum efficiency was maximized in this range. The optimum dc current bias was about 2% above the threshold current. Differential delays have also been measured down to a few picosecond accuracy by a unique phase-angle measurement method using a vector voltmeter. Some of the temperature effects observed may be related to mode changes and multimode and superradiance behavior.

Eng, S. T.↗

Precise Phase Comparator for Nearly Equal Frequencies

New circuit precisely compares phases of two RF signals nearly equal in frequency, such as two hydrogen-maser frequency standards. Measuring circuit minimizes interactions between two sources. Also stabilized against thermal effects and against noise that could produce erroneous readings. Heat sinking, buffer amplifiers, and low-noise zero-crossing detector make picosecond precision possible.

Reinhardt, V. S.↗

Studies on lasers and laser devices

The goal of this grant was to study lasers, laser devices, and uses of lasers for investigating physical phenomena are studied. The active projects included the development of a tunable, narrowband XUV light source and its application to the spectroscopy of core excited atomic states, and the development of a technique for picosecond time resolution spectroscopy of fast photophysical processes.

Harris, S. E.↗

Mini-cavity-dumped laser

Lasers for use in high precision satellite ranging systems consist typically of an oscillator followed by several amplifier stages. While the shortest optical pulses are achieved by using a mode locked oscillator, such an oscillator is incompatible with the compact design needed in future, highly mobile systems. The laser oscillator achieves pulse lengths approaching those obtainable by mode locking, but in a much more compact and stable design. The oscillator uses two LiNbO3 Pockels cells inside the resonator. One Q-switches the oscillator, and the other is used in a pulse slicing scheme to cavity dump a portion of the circulating optical energy. The length of the optical output pulse measured at 425 + or - 50 picoseconds.

Reed, E.↗

Effect of hydrogen bonding on the vibrational dephasing time in glycerol

The vibrational dephasing of the methyl CH2 symmetric stretch mode in glycerol was directly measured over an extended temperature range using picosecond coherent Raman pump and probe spectroscopy. The dephasing time was found to increase dramatically as the temperature of the supercooled liquid was lowered. This observation is attributed to the increased hydrogen bonding with decreasing temperature which hinders the dephasing of the CH2 vibration by reducing molecular motions.

Dorsinville, R.↗

Anti-Stokes scattering as an XUV radiation source

Harris (1977) has shown that laser induced scattering from atoms stored in a metastable level may be used to produce an XUV radiation source with several unique properties, including narrow linewidth, tunability, linear polarization, picosecond pulsewidth, and relatively high peak spectral brightness. The present investigation provides a summary concerning the progress made on the use of this radiation source as a unique instrument for XUV spectroscopy, and as a possible flashlamp for a 200 A laser. Zych et al. (1978) demonstrated that the maximum spectral brightness of the source is that of a blackbody with a temperature of the metastable storage level. The peak count rate and peak spectral brightness of the anti-Stokes emission at 569 A are 17 times and 139 times greater than those of the 584 A resonance line. The anti-Stokes process was employed as an external source of radiation for high resolution spectroscopy of the 3p6 shell of potassium. Attention is also given to emission spectroscopy of lithium, metastable levels which are appropriate for storage, and a hollow cathode discharge.

Harris, S. E.↗

Laser techniques for spectroscopy of core-excited atomic levels

We discuss three techniques which allow the use of tunable lasers for high resolution and picosecond time scale spectroscopy of core-excited atomic levels. These are: anti-Stokes absorption spectroscopy, laser induced emission from metastable levels, and laser designation of selected core-excited levels.

Harris, S. E.↗

Remote sensing of atmospheric pressure and sea state from satellites using short-pulse multicolor laser altimeters

Short pulse multicolor laser ranging systems are currently being developed for satellite ranging applications. These systems use Q-switched pulsed lasers and streak tube cameras to provide timing accuracies approaching a few picoseconds. Satellite laser ranging systems was used to evaluate many important geophysical phenomena such as fault motion, polar motion and solid earth tides, by measuring the orbital perturbations of retroreflector equipped satellites. Some existing operational systems provide range resolution approaching a few millimeters. There is currently considerable interest in adapting these highly accurate systems for use as airborne and satellite based altimeters. Potential applications include the measurement of sea state, ground topography and atmospheric pressure. This paper reviews recent progress in the development of multicolor laser altimeters for use in monitoring sea state and atmospheric pressure.