Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “phase variation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Continued investigation of potential application of Omega navigation to civil aviation

Major attention is given to an analysis of receiver repeatability in measuring OMEGA phase data. Repeatability is defined as the ability of two like receivers which are co-located to achieve the same LOP phase readings. Specific data analysis is presented. A propagation model is described which has been used in the analysis of propagation anomalies. Composite OMEGA analysis is presented in terms of carrier phase correlation analysis and the determination of carrier phase weighting coefficients for minimizing composite phase variation. Differential OMEGA error analysis is presented for receiver separations. Three frequency analysis includes LOP error and position error based on three and four OMEGA transmissions. Results of phase amplitude correlation studies are presented.

Baxa, E. G., Jr.↗

Real-time correction of atmospherically degraded telescope images through image sharpening

We present a new technique for the correction of atmospheric distortion in telescope images. Most of this distortion arises from a random phase variation of the incoming light across the telescope aperture. This variation limits the resolving power of even large telescopes to about one arc second. If the sharpness of the images is defined in a suitable way, this sharpness is maximized only when the phase distortion of the incoming light is zero. We present computer simulations of a simple feedback system in which active optical elements, set to maximize the sharpness, correct most of the atmospheric distortion. Photon statistics set the limiting magnitude of the object for which a practical feedback system can work. Details in a sixth magnitude object smaller than 0.1 sec of arc should be resolvable. The system can be conveniently employed within existing telescopes.

Muller, R. A.↗

Investigation of new techniques for aircraft navigation using the omega navigation

An OMEGA navigation receiver with a microprocessor as the computational component was investigated. A version of the INTEL 4004 microprocessor macroassembler suitable for use on the CDC-6600 system and development of a FORTRAN IV simulator program for the microprocessor was developed. Supporting studies included development and evaluation of navigation algorithms to generate relative position information from OMEGA VLF phase measurements. Simulation studies were used to evaluate assumptions made in developing a navigation equation in OMEGA Line of Position (LOP) coordinates. Included in the navigation algorithms was a procedure for calculating a position in latitude/longitude given an OMEGA LOP fix. Implementation of a digital phase locked loop (DPLL) was evaluated on the basic of phase response characteristics over a range of input phase variations. Included also is an analytical evaluation on the basis of error probability of an algorithm for automatic time synchronization of the receiver to the OMEGA broadcast format. The use of actual OMEGA phase data and published propagation prediction corrections to determine phase velocity estimates was discussed.

Baxa, E. G., Jr.↗

Does spectroscopic evidence require two scattering layers in the Venus atmosphere.

Comments on Hunt's (1972) conclusion that the phase variation of lines in the 7820- and 7883-A CO2 bands is due to the presence of two scattering layers in the Venusian atmosphere. It is shown that the increase of equivalent width with phase between 0 and 90 deg noted by Hunt in the data by Gray Young et al. (1971) does not necessarily require a two-layer model of scattering in the Venusian atmosphere and that this increase may be due to the strong backward lobe in the Venusian cloud phase function. Hunt, in a reply, notes that Regas et al. incorrectly use in their analysis Hansen's (1969) data which are for a homogeneous planetary atmosphere, while Hunt used an inhomogeneous model of the Venusian atmosphere. In addition, further evidence to support Hunt's claim for a multilayered structure of the upper Venusian clouds is presented.

Regas, J. L.↗

A very high frequency radio interferometer for investigating ionospheric disturbances using geostationary satellites. Determination of changes in exospheric electron content by a comparison of group delay and Faraday rotation

The theory and development of a VHF correlation radio interferometer for investigating ionospheric disturbances are discussed. The system was developed to receive signals from the geostationary Applications Technology Satellites. Amplitude and phase variations of the signal passing through the ionosphere can be detected by this instrument. The system consists of two superheterodyne receivers separated by a distance known as the baseline of the system. Since the system is a phase sensitive instrument, the local oscillators of the two receivers must be phase coherent. This is accomplished by using phase-locked loops for generating the local oscillators. The two signals from the separate receivers are cross-correlated by multiplying the two signals together and then time averaging the result. The sensitivity of the instrument is increased by off-setting one of the local oscillators by a small amount.

Terry, R.↗

Modulator for tone and binary signals

Tones and binary information are transmitted as phase variations on a carrier wave of constant amplitude and frequency. The carrier and tones are applied to a balanced modulator for deriving an output signal including a pair of sidebands relative to the carrier. The carrier is phase modulated by a digital signal so that it is + or - 90 deg out of phase with the predetermined phase of the carrier. The carrier is combined in an algebraic summing device with the phase modulated signal and the balanced modulator output signal. The output of the algebraic summing device is hard limited to derive a constant amplitude and frequency signal having very narrow bandwidth requirements. At a receiver, the tones and binary data are detected with a phase locked loop having a voltage controlled oscillator driving a pair of orthogonal detection channels.

Mcchesney, J. R.↗

Deferred electronic heterodyne moire deflectometry: A method for transient density fields measurement

Effects of spherical aberrations of the mirror used in the moire system on the angular resolution of the system are investigated. It is shown that the spherical aberrations may reduce significantly the performance of the conventional moire deflectometer. However, due to the heterodyne procedure, this is not the case with the heterodyne moire system. A moire system with a constant speed moving grating is demonstrated. It is shown that the system readout is linear and the system does not need calibration. In addition, the repeatability of the measurements is improved in this system as compared to the sinusoidally moving grating setup. The problem of the photographic plates alignment is solved by using a mechanical system in which the plate is held firmly throughout the experiment and accurately replaced after removing for photographic processing. The effect of a circular detector's aperture size on readout was tested. It is shown that the spatial phase variations, observed when scanning along a straight moire fringe, may considerably be reduced. At present we may say that both the on-line and the deferred heterodyne moire techniques may reliably be used. The errors of phase readings are 1 deg and 5 deg for the on-line and deferred methods. The total error due to subtraction of two readings at each position is, therefore, 1.4 deg and 7 deg, respectively. Further research for improving the deferred system is suggested.

Stricker, Josef↗

Model of an axially strained weakly guiding optical fiber modal pattern

Axial strain may be determined by monitoring the modal pattern variation of an optical fiber. In this paper we present the results of a numerical model that has been developed to calculate the modal pattern variation at the end of a weakly guiding optical fiber under axial strain. Whenever an optical fiber is under stress, the optical path length, the index of refraction and the propagation constants of each fiber mode change. In consequence, the modal phase term of the fields and the fiber output pattern are also modified. For multimode fibers, very complicated patterns result. The predicted patterns are presented, and an expression for the phase variation with strain is derived.

Egalon, Claudio O.↗

Model of an axially strained weakly guiding optical fiber modal pattern

Axial strain can be determined by monitoring the modal pattern variation of an optical fiber. The results of a numerical model developed to calculate the modal pattern variation at the end of a weakly guiding optical fiber under axial strain is presented. Whenever an optical fiber is under stress, the optical path length, the index of refraction, and the propagation constants of each fiber mode change. In consequence, the modal phase term for the fields and the fiber output pattern are also modified. For multimode fibers, very complicated patterns result. The predicted patterns are presented, and an expression for the phase variation with strain is derived.

Egalon, Claudio O.↗

A sub-picosecond digital clock monitoring system

We describe a low-cost system designed to monitor wander in digital clocks with a precision of ≤ 1 ps. With this system we have shown that it is possible to track phase variations at the sub-picosecond level by adding noise to a reference clock. As in many cases where a clock is part of a complex distribution network small changes in temperature and other effects can lead to small changes in the clock's phase. As a further demonstration of the system, we have used it to measure the phase changes induced in optical signals in fibers.

47 OTHER INSTRUMENTATION↗

The structure of a separating turbulent boundary layer. V Frequency effects on periodic unsteady free-stream flows

The results of experimental trials to obtain measurements of the effects of frequency on the sinusoidal variations in the free stream velocity over a separating turbulent boundary layer are reported. An oscillation frequency of 0.596 Hz was examined, in conjunction with a free stream velocity of 10.18 m/sec. Hot-wire anemometers measured the velocity upstream of the separation and the phase-averaged skin friction, while the velocities in the detached flow zone and the downstream velocity were assayed with a laser anemometer. Large amplitude and phase variations developed at the beginning of separation, producing hysteresis in the relationships between flow parameters. Increases in the free stream velocity decreased the detached shear layer thickness, while in the deceleration segment of the cycle the separated shear layer grew thicker. The results are in a frequency range that are significant for axial compressor blades and helicopter blades.

Simpson, R. L.↗

Phase-Array Approach to Optical Whispering Gallery Modulators

This technology leverages the well-defined orbital number of a whispering gallery modulator (WGM) to expand the range of applications for such resonators. This property rigidly connects the phase variation of the field in this mode with the azimuthal angle between the coupling locations. A WGM with orbital momentum L has exactly L instant nodes around the circumference of the WGM resonator supporting such a mode. Therefore, in two locations separated by the arc alpha, the phase difference of such a field will be equal to phi= alpha L. Coupling the field out of such locations, and into a balanced interferometer, once can observe a complete constructive or distractive interference (or have any situation in between) depending on the angle alpha. Similarly, a mode L + delta L will pick up the phase phi + alpha delta L. In all applications of a WGM resonator as a modulator, the orbital numbers for the carrier and sidebands are different, and their differences delta L are known (usually, but not necessarily, delta L = 1). Therefore, the choice of the angle alpha, and of the interferometer arms difference, allows one to control the relative phase between different modes and to perform the conversion, separation, and filtering tasks necessary.

Strekalov, Dmitry↗

SABER (TIMED) and MLS (UARS) Temperature Observations of Mesospheric and Stratospheric QBO and Related Tidal Variations

More than three years of temperature observations from the SABER (TIMED) and MLS WARS) instruments are analyzed to study the annual and inter-annual variations extending from the stratosphere into the upper mesosphere. The SABER measurements provide data from a wide altitude range (15 to 95 km) for the years 2002 to 2004, while the MLS data were taken in the 16 to 55 km altitude range a decade earlier. Because of the sampling properties of SABER and MLS, the variations with local solar time must be accounted for when estimating the zonal mean variations. An algorithm is thus applied that delineates with Fourier analysis the year-long variations of the migrating tides and zonal mean component. The amplitude of the diurnal tide near the equator shows a strong semiannual periodicity with maxima near equinox, which vary from year to year to indicate the influence from the Quasi-biennial Oscillation (QBO) in the zonal circulation. The zonal mean QBO temperature variations are analyzed over a range of latitudes and altitudes, and the results are presented for latitudes from 48"s to 48"N. New results are obtained for the QBO, especially in the upper stratosphere and mesosphere, and at mid-latitudes. At Equatorial latitudes, the QBO amplitudes show local peaks, albeit small, that occur at different altitudes. From about 20 to 40 km, and within about 15" of the Equator, the amplitudes can approach 3S K for the stratospheric QBO or SQBO. For the mesospheric QBO or MQBO, we find peaks near 70 km, with temperature amplitudes reaching 3.5"K, and near 85 km, the amplitudes approach 2.5OK. Morphologically, the amplitude and phase variations derived from the SABER and MLS measurements are in qualitative agreement. The QBO amplitudes tend to peak at the Equator but then increase again pole-ward of about 15" to 20'. The phase progression with altitude varies more gradually at the Equator than at mid-latitudes. A comparison of the observations with results from the Numerical Spectral Model (NSM) reveals that there is qualitative agreement. The NSM generates the QBO extending from the stratosphere into the upper mesosphere, with temperature variations extending to mid latitudes, but the predicted amplitudes are smaller than those observed.

Huang, Frank T.↗

Spatial and temporal variations of monthly mean total columnar ozone derived from 7 years of BUV data

Ninth-degree spherical harmonic models are used to represent monthly mean total columnar ozone fields, with spatial spectra defined in terms of simple analytic expressions representing the rms value of each spherical harmonic coefficient. The spectra are combined with estimation theory techniques to develop a realistic error analysis accounting for errors due to nonglobal coverage. Amplitude and phase variations for longitudinal waves one, two and three are presented, and it is shown that these waves reinforce in space and time in the period of high poleward ozone transport in the northern hemisphere. In the southern hemisphere, the wave two and three components are much smaller, with wave one maximum amplitude occurring in September and October.

Tolson, R. H.↗

Phase Measurements of a 140-GHz Confocal Gyro-Amplifier

The phase stability of a 140-GHz, 1-kW pulsed gyro-amplifier system and the phase dependence on the cathode voltage were experimentally measured. To optimize the measurement precision, the amplifier was operated at 47 kV and 1 A, where the output power was ~ 30 W. The phase was determined to be stable both pulse-to-pulse and during each pulse, so far as the cathode voltage and electron beam current are constant. The phase variation with voltage was measured and found to be 130 ± 30° /kV, in excellent agreement with simulations. The electron gun used in this device is non-adiabatic, resulting in a steep slope of the beam pitch factor with respect to cathode voltage. This was discovered to be the dominant factor in the phase dependence on voltage. The use of an adiabatic electron gun is predicted to yield a significantly smaller phase sensitivity to voltage, and thus a more phase-stable performance. To our knowledge, these are the first phase measurements reported for a gyro-amplifier operating at a frequency above W-band.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Phase Measurements of a 140-GHz Confocal Gyro-Amplifier

The phase stability of a 140-GHz, 1-kW pulsed gyro-amplifier system and the phase dependence on the cathode voltage were experimentally measured. To optimize the measurement precision, the amplifier was operated at 47 kV and 1 A, where the output power was ~30 W. The phase was determined to be stable both pulse-to-pulse and during each pulse, so far as the cathode voltage and electron beam current are constant. The phase variation with voltage was measured and found to be 130 ± 30 deg/kV, in excellent agreement with simulations. The electron gun used in this device is non-adiabatic, resulting in a steep slope of the beam pitch factor with respect to cathode voltage. This was discovered to be the dominant factor in the phase dependence on voltage. The use of an adiabatic electron gun is predicted to yield a significantly smaller phase sensitivity to voltage, and thus a more phase-stable performance. To our knowledge, these are the first phase measurements reported for a gyro-amplifier operating at a frequency above W-band.

Rosenzweig, Guy↗