Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “permanence”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Designing stellarators using perpendicular permanent magnets

We have developed a fast method to design perpendicular permanent magnets for simplifying stellarator coils based on existing codes. Coil complexity is one of the main challenges for stellarators. To date, only electromagnetic coils have been used to generate 3D fields for stellarators. Permanent magnets provide an alternative way to produce the desired magnetic field for optimized stellarators. In this paper, we revisit the concept of representing surface current using magnetic dipoles and carry out numerical validations. A surface magnetization is proven to be equivalent to the surface current that can be linearly solved by existing coil design codes. An incremental multi-layer method has been developed to obtain a practical solution that is attainable with present permanent magnets. With this method, we can reproduce a half-Tesla NCSX configuration using specially designed neodymium magnets together with simple planar coils. It shows that stellarator coils could be substantially simplified by adopting permanent magnets.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laminated Permanent Magnets Enable Compact Magnetic Components in Current Source Converters

Magnetic components play a key role in determining the size, cost, efficiency of a power converter. They are more significant in current source converters, where the dc-link energy is stored in an inductor/transformer. In such cases, the magnetics have a predominantly DC flux, superimposed by an AC flux at switching frequency. Previously, permanent magnets have been proposed to offset the DC flux and thereby reduce the size, cost, and losses of the inductors/transformers. This paper starts by analyzing the issue of eddy currents when using such standard permanent magnets, especially in medium frequency applications, making them practically unusable. Alternatively, the paper proposes the use of laminated permanent magnets to reduce these eddy currents and thereby realize the benefits of offsetting the DC flux to reduce the size, cost, and loss of inductors/transformers. Using a soft-switching solid-state transformer as an example, experimental results are presented to show the impact of eddy currents in standard permanent magnets when used with a medium frequency transformer. Here, experimental results showing the benefits of using laminated magnets in reducing the eddy currents are presented.

30 DIRECT ENERGY CONVERSION↗

Dose calculation for permanent prostate implants incorporating spatially anisotropic linearly time-resolving edema

Purpose: The objectives of this study were (i) to develop a dose calculation method for permanent prostate implants that incorporates a clinically motivated model for edema and (ii) to illustrate the use of the method by calculating the preimplant dosimetry error for a reference configuration of {sup 125}I, {sup 103}Pd, and {sup 137}Cs seeds subject to edema-induced motions corresponding to a variety of model parameters. Methods: A model for spatially anisotropic edema that resolves linearly with time was developed based on serial magnetic resonance imaging measurements made previously at our center to characterize the edema for a group of n=40 prostate implant patients [R. S. Sloboda et al., ''Time course of prostatic edema post permanent seed implant determined by magnetic resonance imaging,'' Brachytherapy 9, 354-361 (2010)]. Model parameters consisted of edema magnitude, {Delta}, and period, T. The TG-43 dose calculation formalism for a point source was extended to incorporate the edema model, thus enabling calculation via numerical integration of the cumulative dose around an individual seed in the presence of edema. Using an even power piecewise-continuous polynomial representation for the radial dose function, the cumulative dose was also expressed in closed analytical form. Application of the method was illustrated by calculating the preimplant dosimetry error, RE{sub preplan}, in a 5x5x5 cm{sup 3} volume for {sup 125}I (Oncura 6711), {sup 103}Pd (Theragenics 200), and {sup 131}Cs (IsoRay CS-1) seeds arranged in the Radiological Physics Center test case 2 configuration for a range of edema relative magnitudes ({Delta}=[0.1,0.2,0.4,0.6,1.0]) and periods (T=[28,56,84] d). Results were compared to preimplant dosimetry errors calculated using a variation of the isotropic edema model developed by Chen et al. [''Dosimetric effects of edema in permanent prostate seed implants: A rigorous solution,'' Int. J. Radiat. Oncol., Biol., Phys. 47, 1405-1419 (2000)]. Results: As expected, RE{sub preplan} for our edema model indicated underdosage in the calculation volume with a clear dependence on seed and calculation point positions, and increased with increasing values of {Delta} and T. Values of RE{sub preplan} were generally larger near the ends of the virtual prostate in the RPC phantom compared with more central locations. For edema characteristics similar to the population average values previously measured at our center, i.e., {Delta}=0.2 and T=28 d, mean values of RE{sub preplan} in an axial plane located 1.5 cm from the center of the seed distribution were 8.3% for {sup 131}Cs seeds, 7.5% for {sup 103}Pd seeds, and 2.2% for {sup 125}I seeds. Maximum values of RE{sub preplan} in the same plane were about 1.5 times greater. Note that detailed results strictly apply only for loose seed implants where the seeds are fixed in tissue and move in synchrony with that tissue. Conclusions: A dose calculation method for permanent prostate implants incorporating spatially anisotropic linearly time-resolving edema was developed for which cumulative dose can be written in closed form. The method yields values for RE{sub preplan} that differ from those for spatially isotropic edema. The method is suitable for calculating pre- and postimplant dosimetry correction factors for clinical seed configurations when edema characteristics can be measured or estimated.

60 APPLIED LIFE SCIENCES↗

WE-AB-BRA-11: Improved Imaging of Permanent Prostate Brachytherapy Seed Implants by Combining an Endorectal X-Ray Sensor with a CT Scanner

Purpose: To test feasibility of the use of a digital endorectal x-ray sensor for improved image resolution of permanent brachytherapy seed implants compared to conventional CT. Methods: Two phantoms simulating the male pelvic region were used to test the capabilities of a digital endorectal x-ray sensor for imaging permanent brachytherapy seed implants. Phantom 1 was constructed from acrylic plastic with cavities milled in the locations of the prostate and the rectum. The prostate cavity was filled a Styrofoam plug implanted with 10 training seeds. Phantom 2 was constructed from tissue-equivalent gelatins and contained a prostate phantom implanted with 18 strands of training seeds. For both phantoms, an intraoral digital dental x-ray sensor was placed in the rectum within 2 cm of the seed implants. Scout scans were taken of the phantoms over a limited arc angle using a CT scanner (80 kV, 120–200 mA). The dental sensor was removed from the phantoms and normal helical CT and scout (0 degree) scans using typical parameters for pelvic CT (120 kV, auto-mA) were collected. A shift-and add tomosynthesis algorithm was developed to localize seed plane location normal to detector face. Results: The endorectal sensor produced images with improved resolution compared to CT scans. Seed clusters and individual seed geometry were more discernable using the endorectal sensor. Seed 3D locations, including seeds that were not located in every projection image, were discernable using the shift and add algorithm. Conclusion: This work shows that digital endorectal x-ray sensors are a feasible method for improving imaging of permanent brachytherapy seed implants. Future work will consist of optimizing the tomosynthesis technique to produce higher resolution, lower dose images of 1) permanent brachytherapy seed implants for post-implant dosimetry and 2) fine anatomic details for imaging and managing prostatic disease compared to CT images. Funding: LSU Faculty Start-up Funding. Disclosure: XDR Radiography has loaned our research group the digital x-ray detector used in this work. CoI: None.

60 APPLIED LIFE SCIENCES↗

Design and instrumentation for permanent magnet samples exposed to a radiation environment

This work is part of a larger program to study the effects of radiation on permanent magnets in an accelerator environment. In order to be sure that the permanent magnet samples are accurately placed, measured, and catalogued we have developed a system of sample racks, holders and measuring apparatuses. We have combined these holders and measurement racks with electronics to allow a single computer to catalogue the position and intensity of the magnet measurements. We outline the design of the apparatus, the collection software, and the methodology we will use to collect the data.

Accelerator Physics↗

Permanent Magnet Synchronous Motors for Commercial Refrigeration (Final Report)

This report provides background information on various fractional-horsepower electric motor technologies used for evaporator fan applications in commercial refrigeration and summarizes data from a DOE-sponsored evaporator fan motor laboratory and field demonstration project. This report also extrapolates that data to project the potential economic and environmental benefits resulting from upgrading the current installed base of commercial refrigeration evaporator fan motors to permanent magnet synchronous (PMS) motors.Evaporator fan motors used in commercial refrigeration applications are fractional horsepower in size, responsible for moving air across the evaporator coil, and typically run at one speed. Historically, shaded-pole induction motors have been the most commonly used evaporator fan motors in commercial refrigeration equipment and beverage vending machines. These are the simplest and least expensive type of fractional-horsepower motor, with an efficiency of approximately 20%. Electronically commutated (EC) permanent magnet motors, also known as brushless DC motors, were initially commercialized in the late 1980s, and their use in commercial refrigeration applications has increased within the last 10 to 15 years because of economic incentives and regulatory requirements. State-of-the-art EC motors are approximately 66% efficient. Another induction motor type, the permanent split capacitor (PSC) motor, offers a mid-point between shaded-pole and EC motor price and efficiency levels. PSC motors are typically about 29% efficient.A permanent magnet synchronous (PMS) AC motor that can directly use grid-supplied AC current without the need to rectify to DC has recently been commercialized. This new motor exhibits a peak efficiency of 75% and has the potential to significantly reduce the energy consumption of evaporator fan motors in commercial refrigeration equipment. Laboratory evaluation of evaporator fan motor technologies was performed to quantify and compare the performance of shaded-pole, PSC, EC, and PMS evaporator fan motors in a controlled environment, so as to minimize the influence of external factors and anomalies. The laboratory evaluation included dynamometer testing of the fan motors and airflow testing of the motor/fan assemblies. It was found that the 6–12 W PMS motor exhibited a peak efficiency of 75% with a power factor of approximately 0.9 at a power output of 11 W. It was also found that a 38–50 W PMS motor exhibited a peak efficiency of 82% with a power factor of approximately 0.9 at a power output of 35 W.Airflow testing of shaded-pole, PSC, EC, and PMS motor/fan assemblies was performed using an airflow test chamber, which was designed in accordance with ANSI/AMCA Standard 210-16/ASHRAE Standard 51-16, to measure the performance of the subject motor/fan assembly and to determine the incumbent display case system impedance (AMCA 2016). A family of fan curves (static pressure vs airflow rate and electrical power input vs airflow rate) was generated for the 6–12 W PMS motor/fan assemblies with 8-inch fan blades pitched from 17 to 32 degrees. A similar set of curves was generated for the 38–50 W motors paired with 10 and 12-inch blades. Various incumbent motor/fan assemblies were also tested in the laboratory airflow test chamber and their fan curves were generated.Field evaluation of refrigerated display case evaporator fan motors was accomplished by performing side-by-side comparisons of 6–12 W PMS motors to 6–12 W shaded-pole and EC evaporator fan motors. It was found that, on average, a PMS motor consumes 79% less power and draws 82% less current than a shaded pole motor, and on average, 34% less power and 49% less current than an EC motor. In addition, the PMS motor exhibits an average power factor of approximately 0.82, which is on average 40% greater than that of existing evaporator fan motors.Two field test sites were selected to evaluate the performance of the larger 38 to 50 W PMS evaporator fan motors in walk-in cooler/freezer applications. At each supermarket, two walk-in units were selected for investigation: one walk-in dairy cooler and one walk-in freezer. A 61% decrease in fan motor power was measured when retrofitting existing evaporator fan motors with PMS motors in the walk-in cooler. In addition, a 48% decrease in fan motor power was measured when retrofitting existing evaporator fan motors with PMS motors in the walk-in freezer.The culmination of the field evaluation of fan motor technologies was a whole-store retrofit conducted at a supermarket. Pre- and post-retrofit measurement of evaporator fan motor power in medium- and low-temperature refrigerated display cases and walk-in coolers/freezers was performed. Overall for the whole-store retrofit, the current supplied to all monitored evaporator fan motors was reduced by 52%, the real power was reduced by 46% and the apparent power was reduced by 51% following the retrofit of the 262 evaporator fan motors that w

42 ENGINEERING↗

Experimental transient and permanent deformation studies of steel-sphere-impacted or impulsively-loaded aluminum beams with clamped ends

The sheet explosive loading technique (SELT) was employed to obtain elastic-plastic, large-deflection transient and/or permanent strain data on simple well-defined structural specimens and materials: initially-flat 6061-T651 aluminum beams with both ends ideally clamped via integral construction. The SELT loading technique was chosen since it is both convenient and provides forcing function information of small uncertainty. These data will be useful for evaluating pertinent structural response prediction methods. A second objective was to obtain high-quality transient-strain data for a well-defined structural/material model subjected to impact by a rigid body of known mass, impact velocity, and geometry; large-deflection, elastic-plastic transient response conditions are of primary interest. The beam with both ends clamped and a steel sphere as the impacting body were chosen. The steel sphere was launched vertically by explosive propulsion to achieve various desired impact velocities. The sphere/beam impact tests resulted in producing a wide range of structural responses and permanent deformations, including rupture of the beam from excessive structural response in two cases. The transient and permanent strain data as well as the permanent deflection data obtained are of high quality and should be useful for checking and evaluating methods for predicting the responses of simple 2-d structures to fragment (sphere) impact. Transient strain data very close to the point of impact were not obtained over as long a time as desirable because the gage(s) in that region became detached during the transient response.

Witmer, E. A.↗

Dovetail spoke internal permanent magnet machine

An internal permanent magnet (IPM) machine is provided. The IPM machine includes a stator assembly and a stator core. The stator core also includes multiple stator teeth. The stator assembly is further configured with stator windings to generate a stator magnetic field when excited with alternating currents and extends along a longitudinal axis with an inner surface defining a cavity. The IPM machine also includes a rotor assembly and a rotor core. The rotor core is disposed inside the cavity and configured to rotate about the longitudinal axis. The rotor assembly further includes a shaft. The shaft further includes multiple protrusions alternately arranged relative to multiple bottom structures provided on the shaft. The rotor assembly also includes multiple stacks of laminations disposed on the protrusions and dovetailed circumferentially around the shaft. The rotor assembly further includes multiple pair of permanent magnets for generating a magnetic field, which magnetic field interacts with the stator magnetic field to produce a torque. The multiple pair of permanent magnets are disposed between the stacks. The rotor assembly also includes multiple middle wedges mounted between each pair of the multiple permanent magnets.

47 OTHER INSTRUMENTATION↗

High speed internal permanent magnet machine and method of manufacturing the same

An internal permanent magnet (IPM) machine is provided. The IPM machine includes a stator assembly and a stator core. The stator core also includes multiple stator teeth. The stator assembly is further configured with stator windings to generate a magnetic field when excited with alternating currents and extends along a longitudinal axis with an inner surface defining a cavity. The IPM machine also includes a rotor assembly and a rotor core. The rotor core is disposed inside the cavity and configured to rotate about the longitudinal axis. The rotor assembly further includes a shaft. The shaft further includes multiple protrusions alternately arranged relative to multiple bottom structures provided on the shaft. The rotor assembly also includes multiple stacks of laminations disposed on the protrusions and dovetailed circumferentially around the shaft. The rotor assembly further includes multiple permanent magnets for generating a magnetic field, which interacts with the stator magnetic field to produce torque. The permanent magnets are disposed between the stacks. The rotor assembly also includes multiple bottom wedges disposed on the bottom structures of the shaft and configured to hold the multiple stacks and the multiple permanent magnets.

47 OTHER INSTRUMENTATION↗

Adjustable permanent magnet assembly for NMR and MRI

System and methods for designing and using single-sided magnet assemblies for magnetic resonance imaging (MRI) are disclosed. The single-sided magnet assemblies can include an array of permanent magnets disposed at selected positions. At least one of the permanent magnets can be configured to rotate about an axis of rotation in the range of at least +/-10 degrees and can include a magnetization having a vector component perpendicular to the axis of rotation. The single-sided magnet assemblies can further include a magnet frame that is configured to hold the permanent magnets in place while allowing the at least one of the permanent magnets to rotate about the axis of rotation.

42 ENGINEERING↗

Method for mitigating thermal aging of permanent magnets in organic liquid

An electric motor is provided for use in an electromechanical transmission that utilizes automatic transmission fluid. The electric motor includes a stator and a rotor. The rotor includes a plurality of permanent magnets can include magnetic particles coated with hydrogen impermeable material. According to an alternative embodiment, the entire permanent magnet or the rotor itself can be coated with hydrogen impermeable material. According to a further alternative embodiment, the permanent magnet particles can be secured by a binder that includes a hydrogen storage compound that prevents hydrogen from affecting magnetic properties of the permanent magnet.

42 ENGINEERING↗

CELLULAR COFFERDAMS AS PERMANENT HYDROPOWER DAM STRUCTURES

This paper presents the results of a comprehensive study on the potential use of cellular cofferdams as basis for the design and construction of water retaining structures to sustainably and cost-effectively harness hydropower. Previously, cellular cofferdams have been widely used mainly as temporary water exclusion devices to permit dry construction of in-water structures such as dams, locks, bridge footings and piers, and hydroelectric power plants. Design and construction requirements for cellular cofferdams are less stringent than for hydropower dams. To make cellular cofferdams suitable for permanent hydropower use, different design concepts that utilize cellular cofferdams as the main or core element of the water-retaining dam structure are proposed. One particular key design concept is the so-called “dry construction technique” in which the granular fill in cofferdam cells and the downstream berm are permanently kept dry in contrast to the wet construction technique for temporary use of cellular cofferdams. The viability of the proposed permanent cellular cofferdam design concepts is demonstrated using well-established structural and geotechnical design procedures and computational modeling. The improved performance of the proposed design concepts, particularly in combination with the dry construction technique, show cellular cofferdams have the potential to be used as basis for the construction of permanent hydropower dam structures that are versatile, with less impact on the environment, and will cost less to build than conventional hydropower dams.

13 HYDRO ENERGY↗

Regulatory Framework for Permanent Shut-down and Decommissioning of Nuclear Power Plant in Korea - 18101

Kori Unit 1, the first commercial NPP in Korea which was commissioned in 1978, was put on permanent shutdown for decommissioning on June 2017, after 40 years of operation. For permanent shutdown of the Kori Unit 1, an operation change permit was submitted in 2016 prior to the expiration since the NSA (Nuclear Safety Act) recognizes permanent shutdown as one of the operation stage. In preparation for the decommissioning of Kori Unit 1, the NSA related to decommissioning was revised and promulgated in 2015. The lower statues including Enforcement Decree and Regulation of the NSA, etc. were promptly revised to reflect decommissioning related requirements and procedures accordingly. For new NPPs, preliminary decommissioning plan is submitted and is being reviewed in the course of license review. Operating NPPs are also planning to submit the decommissioning plan by 2018 and receive approvals from Nuclear Safety and Security Commission. In case that an operator intends to decommission a nuclear installation, the operator shall apply for decommissioning and receive an approval from the NSSC. As discussed, framework for permanent shutdown and decommissioning of nuclear facilities have been well formatted by successful revision of NSA in Korea. Further detailed technical standards and regulatory guides on decommissioning will be developed to facilitate the relevant activities and ensure the nuclear safety. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Consideration for Implementing the Safety Regulation Plans on Permanent Shut-own NPP during Transition Period in Korea

Recently the Korean regulatory body has been reviewing the change of permission on permanent shutdown Kori NPP (Nuclear Power Plant) unit 1, since the licensee (KHNP, Korea Hydro and Nuclear Power Co. Ltd) decided the permanent shut-down in June 2015 and applied the amendment of its licensing basis documents in June 2016. Although our institute with technical authority, the KINS (Korea Institute of Nuclear Safety), had performed the peer reviews for the construction permits of 3 NPPs and operating licenses of 25 NPPs, the safety control of permanent shut-down NPP and the transition activities including deactivation and decommissioning preparation are still in early stages and challenging fields. Currently the operation/only-possession system under defueled condition were defined through the peer review of fully revised documents and the major issues which concerned with the rearrangement of safety class or function based on new accident analysis results were produced. And also various transition activities were drawn as reflecting the decommissioning strategy on Kori unit 1. In this study, we described the status and problem of safety regulation based on our subordinate statute for permanent shut-down and transition activities. And then the detail implementation plans or the alternatives will be provided and discussed in order to solve the lack of regulatory experience and guide.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Identification and recovery of rare-earth permanent magnets from waste electrical and electronic equipment

Highlights: • Different WEEE were analyzed and the rare-earth permanent magnets were collected. • Chemical composition evolution of Nd-Fe-B alloys over the years is illustrated. • Loudspeakers from laptops and loudspeakers from flat TV contained Nd-Fe-B magnets. • The amount of Nd-Fe-B could double if the loudspeakers streams are included. - Abstract: Nd-Fe-B permanent magnets are a strategic material for a number of emerging technologies. They are a key component in the most energy efficient electric motors and generators, thus, they are vital for energy technologies, industrial applications and automation, and future forms of mobility. Rare earth elements (REEs) such as neodymium, dysprosium and praseodymium are also found in waste electrical and electronic equipment (WEEE) in volumes that grow with the technological evolution, and are marked as critical elements by the European Commission due to their high economic importance combined with significant supply risks. Recycling could be a good approach to compensate for the lack of rare earths (REs) on the market. However, less than 1% of REs are currently being recycled, mainly because of non-existing collection logistics, lack of information about the quantity of RE materials available for recycling and recycling-unfriendly product designs. To improve these lack of information, different waste streams of electrical and electronic equipment from an industrial recycling plant were analyzed in order to localize, identify and collect RE permanent magnets of the Nd-Fe-B type. This particular type of magnets were mainly found in hard disk drives (HDDs) from laptops and desktop computers, as well as in loudspeakers from compact products such as flat screen TVs, PC screens, and laptops. Since HDDs have been investigated thoroughly by many authors, this study focusses on other potential Nd-Fe-B resources in electronic waste. The study includes a systematic survey of the chemical composition of the Nd-Fe-B magnets found in the selected waste streams, which illustrates the evolution of the Nd-Fe-B alloys over the years. The study also provides an overview over the types of magnets integrated in different waste electric and electronic equipment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

MnBi 2 Is a Permanent Magnet

Creating and understanding new permanent magnets requires an understanding of the impact of orbital angular momentum on coercivity. A simple approach to interrogating this relationship is by incorporating high Z (where Z is the atomic number) elements into binary compounds to maximize spin–orbit coupling. The Mn–Bi system is an appealing platform for these studies since it contains MnBi, a permanent magnet with a large coercive field. We previously identified a new compound in the Mn–Bi system, MnBi 2 , but could not elucidate its magnetic properties ex situ due to its decomposition upon decompression. Here, we harnessed synchrotron X-ray magnetic circular dichroism to probe the magnetism of MnBi 2 at high pressure within a diamond anvil cell. Our results indicate that MnBi 2 exhibits ferromagnetic hysteresis at both 10 K and room temperature. Through calculations and experiments, we show that orbital angular momentum and spin–orbit coupling from Bi impart magnetic anisotropy in MnBi 2 . Comparing the Mn–Bi family of compounds, we consider the Bi p and d orbitals to explain the differences in magnetic behavior within the system. Collectively, these results validate leveraging high-Z elements in the synthesis of new hard permanent magnets.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ion acceleration in a solenoid-free plasma expanded by permanent magnets

Ion acceleration is achieved in a low-pressure solenoid-free plasma expanded by permanent magnet arrays. Although a permanent magnet normally forms cusp magnetic fields which prevents plasma diffusion and double layer formation, by employing double concentric arrays of permanent magnets, a constant field area, and a diverging magnetic field can be generated near the outlet of the plasma source. In the source, a rapid potential drop with 4 cm thickness from 50 V to 20 V is generated at the diverging field area for 0.35 mTorr and a supersonic ion beam accelerated through the potential drop is observed in the diffusion chamber. The beam energy can be increased up to over 40 eV with a decrease in gas pressure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of Compact Electron Cyclotron Resonance Ion Source with Permanent Magnets for High-Energy Carbon-Ion Therapy

Heavy-ion cancer treatment is being carried out at the Heavy Ion Medical Accelerator in Chiba (HIMAC) with 140 to 400 MeV/n carbon ions at National Institute of Radiological Sciences (NIRS) since 1994. At NIRS, more than 4,000 patients have been treated, and the clinical efficiency of carbon ion radiotherapy has been demonstrated for many diseases. A more compact accelerator facility for cancer therapy is now being constricted at the Gunma University. In order to reduce the size of the injector (consists of ion source, low-energy beam transport and post-accelerator Linac include these power supply and cooling system), an ion source requires production of highly charged carbon ions, lower electric power for easy installation of the source on a high-voltage platform, long lifetime and easy operation. A compact Electron Cyclotron Resonance Ion Source (ECRIS) with all permanent magnets is one of the best types for this purpose. An ECRIS has advantage for production of highly charged ions. A permanent magnet is suitable for reduce the electric power and cooling system. For this, a 10 GHz compact ECRIS with all permanent magnets (Kei2-source) was developed. The maximum mirror magnetic fields on the beam axis are 0.59 T at the extraction side and 0.87 T at the gas-injection side, while the minimum B strength is 0.25 T. These parameters have been optimized for the production of C{sup 4+} based on experience at the 10 GHz NIRS-ECR ion source. The Kei2-source has a diameter of 320 mm and a length of 295 mm. The beam intensity of C{sup 4+} was obtained to be 618 e{mu}A under an extraction voltage of 30 kV. Outline of the heavy ion therapy and development of the compact ion source for new facility are described in this paper.

62 RADIOLOGY AND NUCLEAR MEDICINE↗