Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “peak load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Benefits of Leapfrogging to Superefficiency and Low Global Warming Potential Refrigerants in Room Air Conditioning

Hydrofluorocarbons (HFCs) emitted from uses such as refrigerants and thermal insulating foam, are now the fastest growing greenhouse gases (GHGs), with global warming potentials (GWP) thousands of times higher than carbon dioxide (CO2). Because of the short lifetime of these molecules in the atmosphere, mitigating the amount of these short-lived climate pollutants (SLCPs) provides a faster path to climate change mitigation than control of CO2 alone. This has led to proposals from Africa, Europe, India, Island States, and North America to amend the Montreal Protocol on Substances that Deplete the Ozone Layer (Montreal Protocol) to phase-down high-GWP HFCs. Simultaneously, energy efficiency market transformation programs such as standards, labeling and incentive programs are endeavoring to improve the energy efficiency for refrigeration and air conditioning equipment to provide life cycle cost, energy, GHG, and peak load savings. In this paper we provide an estimate of the magnitude of such GHG and peak electric load savings potential, for room air conditioning, if the refrigerant transition and energy efficiency improvement policies are implemented either separately or in parallel. We find that implementing HFC refrigerant transition and energy efficiency improvement policies in parallel for room air conditioning, roughly doubles the benefit of either policy implemented separately. We estimate that shifting the 2030 world stock of room air conditioners from the low efficiency technology using high-GWP refrigerants to higher efficiency technology and low-GWP refrigerants in parallel would save between 340-790 gigawatts (GW) of peak load globally, which is roughly equivalent to avoiding 680-1550 peak power plants of 500MW each. This would save 0.85 GT/year annually in China equivalent to over 8 Three Gorges dams and over 0.32 GT/year annually in India equivalent to roughly twice India’s 100GW solar mission target. While there is some uncertainty associated with emissions and growth projections, moving to efficient room air conditioning (~30% more efficient than current technology) in parallel with low-GWP refrigerants in room air conditioning could avoid up to ~25 billion tonnes of CO2 in 2030, ~33 billion in 2040, and ~40 billion in 2050, i.e. cumulative savings up to 98 billion tonnes of CO2 by 2050. Therefore, superefficient room ACs using low-GWP refrigerants merit serious consideration to maximize peak load reduction and GHG savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Commercial Building Technology Demonstration (Final Scientific/Technical Report)

The background for this project was a unique and innovative concept that had been proposed and demonstrated by enVerid Systems, reducing the energy consumption in HVAC systems in commercial and public buildings by up to 50% at peak loads. The concept involves selective scrubbing of gas contaminants from indoor air as a practical substitute for outside air ventilation, the latter being the conventional practice today. This scrubbing enables recycling of most of the indoor air and significantly decreasing the amount of outside air, resulting in a reduced HVAC load and commensurate energy savings for the facility. Key to our approach is low cost scrubbing of all gas contaminants from indoor air using novel, efficient and regenerable sorbent materials. The total solution, labeled HLR (HVAC Load Reduction) is implemented by means of compact modules that can be retrofitted onto virtually any building, and utilizes novel sorbents that have been developed and brought to scale production by enVerid. Although the technology had been deployed and demonstrated, the US commercial building and HVAC markets, famously conservative with respect to innovation and new technologies, had yet to embrace the idea or the product. The overarching goal of the project was to help overcome market hesitancy and enable widespread adoption, by creating a critical mass of success stories across different regions and building types, all under oversight and verification of the DOE and NREL, to ensure credibility and accuracy. The project, overall, was a resounding success. Several installations were deployed and tested comprehensively for the impact on both energy consumption and indoor air quality, and results were not only excellent, but quantitatively in line with expectations. A total number of eight (8) installations were attempted, with 2 aborted due to building issues. Of the six successful installations, however, complete M&V was performed by NREL on 2 (Miami and NYC) and partial analysis on a third site (ArcBest), and these three, along with their results, were therefore presented from a financial and reporting standpoint. Although the number of case studies fell short of the original target of 10, we nevertheless had excellent demonstrations in vastly different climate zones: Southeast, Northeast and Midwest, and in very different building types. This included a modern high-rise office building in New York City and a University Campus health center in Miami, and a mid-rise high-density office in Arkansas. The cooling load reduction was shown to be significant, averaging 37% during the final cooling season in the Miami site. In the NYC site, the cooling energy savings were generally less, at around 12%, as expected. While this is a lower number for average/total savings, two comments are important to note: (i) the outside airflow (OA) reduction was not consistent during the data collection period, at least in part understating the attainable savings through incorrect measurement of the “high energy” reference state; and (ii) the peak impact in NYC is almost certainly as high as Miami, with critical ramifications for peak load reduction and equipment downsizing ability. Importantly, the measured energy savings in all locations were related to the outdoor climate conditions and the actual achievable reduction in outside air, very much in line with models and calculations; this leaves us with increased confidence in our understanding of the interaction between the technology and the building, and our ability to project the impact of this innovation in the future, through broad adoption. Simply put: the energy savings and load reduction impact of the HLR solution has been confirmed quantitatively. The results also confirmed the air quality objective. This may be even more significant, in that air quality is more complex and harder to measure and quantify, and the performance of the HLR as an air scrubber is the linchpin of the entire solution. In all sites, indoor air quality met or exceeded the required parameters, in terms of achieving the target (low) levels of indoor pollutants. Furthermore, the concentrations of outdoor sourced pollutants were markedly lower, as expected, mostly due to the reduction in outside air intake although in part also due to the scrubbing. The success was not immediate nor easy, and early challenges with the systems, especially (but not only) around controls and communication, caused delays in commissioning and undermined some of our M&V schedules. The good news is no fundamental issues were encountered and the number of such glitches was declining quickly by the end of the project. Other challenges had to do with coordinating the control of the building OA dampers, which the HLR needs to have in order to deliver the load reduction, but which the facility manager controls regularly and independently. This is not necessarily a problem for normal HLR operation but interferes with accurate M&V, where switching OA settings back and forth on a precise timetable is essential for clean data. The project provided valuable experience in retrofitting buildings that had been originally designed to operate with less recirculation and more outside air, and some key learnings related to the cyclical regeneration of the sorbents in the operational environment of the building. Some of these learnings gave already been incorporated into ongoing improvements in the design of the HLR module as well as the software that is used to control its operation. The cost and time of retrofit installations is much better understood; so is the test and balance procedure of the building that determines the available range of outside air reduction, which in turn determines the amount of load reduced. We had also implemented at least one annual cycle of sorbent cartridge replacement in the field, after which we tested the used sorbent to assess the rate of degradation of sorbent potency – an important factor affecting the long-term economics of HLR deployments. A notable shortfall of the project, other than the fact that the number of sites was below target, was that we had not (yet) completed testing to measure and verify (M&V) the winter energy savings. This is primarily due to late start on the NYC sites (Miami does not portend any heating savings associated with reduced outside air), combined with the issues of OA damper control. It is by no means suggested that such savings cannot be captured, only that the M&V with respect to winter in NYC has been incomplete. The value of this project and its interest to the general public are hard to overstate. The case studies created from Miami and especially from NYC have, without a doubt, opened up the interest of the broad HVAC industry to HLR in the past year. Major manufacturer reps have signed up to represent and promote the product, and dozens of top tier engineering consultants have introduced HLR as a base of design in upcoming construction and renovation projects – precisely the overarching goal of this project. These would not have happened without the highly visible installation in NYC and its ultimately satisfied customer. Furthermore, the DOE itself issued a report in late 2017 analyzing hundreds of candidate technologies for reducing energy consumption in HVAC; remarkably, the budding HLR solution ranked among the top 3(!); no doubt, its status as a viable and significant contender on this list is informed by the success of these demonstrations. And furthermore, in the wake of these demos, several major energy utilities, led by ConEdison in NYC, have endorsed the HLR solution and now routinely provide substantial cash rebates for customers choosing to incorporate the HLR in their buildings and reap the benefit of the reduced peak load as well as reduced cumulative energy demand. Last but not least, in January of 2019, as this report was being written, the HLR module won the AHR Expo Innovation Award for Green Buildings and, remarkably, the prestigious and only Product of the Year 2019, being selected by an independent professional panel of judges from AHR and ASHRAE. Given the confirmation of the enormous energy saving potential of HLR in widescale deployment, as well as ancillary but significant benefits in terms of equipment downsizing and indoor air quality, the benefit of this effort to the public speaks for itself. Accelerating adoption of HLR, without dependence on subsidies and driven by the private sector, is well under way. There is still much work to be done in terms of educating the HVAC and construction ecosystems and improving the product’s robustness and simplicity, to further facilitate the adoption of this technology and the capture of its potential value. But the American public will greatly benefit both directly and indirectly in the immediate future and beyond.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Performance evaluation of a dynamic wall integrated with active insulation and thermal energy storage systems

Thermal energy storage systems in buildings can store cooling/heating energy during non-peak load hours or when renewable energy sources are available for later use when demanded. Using the building envelope as a thermal battery can help to shave the peak load, reduce the burden in electric grids, and enhance the occupant's thermal comfort. Sensible energy storage on wall systems such as thermally activated building systems can provide an active thermal storage strategy. However, most of the stored energy is used through passive means directed by the thermal lag, which can impede the on-demand release of the stored energy. Integrating active insulation systems with building thermal storage systems can increase the flexibility of charging and discharging time and duration. In this study, a wall system equipped with an active insulation system and thermally activated storage system was designed, and its performance on active cooling energy contribution was studied. The performances of energy storage (charging), release (discharging) of the thermal energy storage energy, and the active insulation system were studied separately and together as an integrated system. Results showed that the thermal properties of the thermal energy storage core material and the pipe spacing of both embedded pipes in the thermal energy storage and hydronic pipes used in the active insulation system affected the wall performance the most out of all the tested wall system parameters. During discharging, the heat flux into the wall was as high as 81.92 W/m 2 . This active insulation system's dynamic R-value varied between less than 1ft 2 •°F•h/BTU (0.18 m 2 •K/W) to 98% of the equally thick foam insulation's R-value.

25 ENERGY STORAGE↗

Technical and Economic Aspects of Designing an Efficient Room Air-Conditioner Program in India

Several studies have projected a massive increase in the demand for air conditioners (ACs) over the next two decades in India. By 2030, room ACs could add 140 GW to the peak load, equivalent to over 30% of the total projected peak load. Therefore, there is significant interest among policymakers, regulators, and utilities in managing room AC demand by enhancing energy efficiency. Building on the historical success of the Indian Bureau of Energy Efficiency’s star-labeling program, Energy Efficiency Services Limited recently announced a program to accelerate the sale of efficient room ACs using bulk procurement, similar to their successful UJALA light-emitting diode (LED) bulk procurement program. This report discusses some of the key considerations in designing a bulk procurement or financial incentive program for enhancing room AC efficiency in India. We draw upon our previous research to demonstrate the overall technical potential and price impact of room AC efficiency improvement and its technical feasibility in India. We also discuss the importance of using low global warming potential (GWP) refrigerants and smart AC equipment that is demand response (DR) ready.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Buckling and Failure Tests of a Subscale Composite Cylinder

A subscale solid laminate composite cylinder 31.5-in. diameter and 47.8 in. long with a [23/0/-23]4S layup known as NDL-1 was designed to fail in buckling and tested in axial compression to collapse twice. The proposed paper will focus on comparing the behavior of NDL-1 from the first test to failure (TTF-1) and the second test to failure (TTF-2). NDL-1 had a peak load of 466.3 kips during TTF-1 and a peak load of 390.4 kips, 15.5% lower, but with a similar stiffness, during TTF-2. Failure initiated at the 200º circumferential location in TTF-1, and at the 30º circumferential location in TTF-2. Though failure initiated at different locations, a similar radial deformation pattern was present just prior to collapse in TTF-1 and TTF-2. A shallow delamination occurred due to the initial failure event in TTF-1, and the damage had no influence on the response of NDL-1 during TTF-2. In the end, it was determined that NDL-1 failed in buckling during TTF-1 and TTF-2, and the second test to failure of NDL-1 highlighted interesting observations with respect to the effect of damage.

Buckling↗

Impact Damage and Strain Rate Effects for Toughened Epoxy Composite Structures

Structural integrity of composite systems under dynamic impact loading is investigated herein. The GENOA virtual testing software environment is used to implement the effects of dynamic loading on fracture progression and damage tolerance. Combinations of graphite and glass fibers with a toughened epoxy matrix are investigated. The effect of a ceramic coating for the absorption of impact energy is also included. Impact and post impact simulations include verification and prediction of (1) Load and Impact Energy, (2) Impact Damage Size, (3) Maximum Impact Peak Load, (4) Residual Strength, (5) Maximum Displacement, (6) Contribution of Failure Modes to Failure Mechanisms, (7) Prediction of Impact Load Versus Time, and (8) Damage, and Fracture Pattern. A computer model is utilized for the assessment of structural response, progressive fracture, and defect/damage tolerance characteristics. Results show the damage progression sequence and the changes in the structural response characteristics due to dynamic impact. The fundamental premise of computational simulation is that the complete evaluation of composite fracture requires an assessment of ply and subply level damage/fracture processes as the structure is subjected to loads. Simulation results for the graphite/epoxy composite were compared with the impact and tension failure test data, correlation and verification was obtained that included: (1) impact energy, (2) damage size, (3) maximum impact peak load, (4) residual strength, (5) maximum displacement, and (6) failure mechanisms of the composite structure.

Chamis, Christos C.↗

Peak Reduction Using Mode Adjustment of Heat Pump Water Heaters in a Residential Neighborhood

Building electrification is putting pressure on distribution grid worldwide. Peak reduction is an important concern that can help reduce the growing stress and allow to defer investments in new capacity. Water heaters represent a convenient way of reducing peak because they are less dependent on weather, and their storage volume allows for asynchronous water heating and hot water use. Previous empirical studies investigated the ability of water heaters to reduce peak through the adjustment of the temperature setpoint. However, not all equipment vendors offer this option. This study aims at understanding the feasibility of peak reduction with an alternative configuration available in the market - by adjusting the device mode rather than temperature setpoint. The peak reduction methodology is tested in an occupied 46-townhome neighborhood located in Atlanta, GA. We find that peak shifting is possible with the adjustable mode approach, with the change in the peak load by 30-60%.

demand response↗

Damage Mechanisms in Tapered Composite Structures Under Static and Fatigue Loading

In this work an integrated computational/experimental approach was developed to validate the predictive capabilities of State-of-the-Art (SoA) Progressive Damage Analysis (PDA) methods and tools. Specifically, a tapered composite structure incorporating ply-drops typical in the aerospace industry to spatially vary structural thickness was tested under static tension and cyclic tension fatigue loads. The data acquired from these tests included quantitative metrics such as pre-peak stiffness, peak load, location of delamination damage onset, and growth of delaminations as functions of applied static and fatigue loads. It was shown that the PDA tools were able to predict the pre-peak stiffness and peak load within ±10% of experimental average, thereby meeting and exceeding the pre-defined success criteria. Additionally, it was shown that the PDA tools were able to accurately predict the location of delamination onset and satisfactorily predict delamination growth under static tension loading. Overall, good correlations were achieved between modeling and experiments.

Rao, Prabhakar M.↗

Effects of Distributed Energy Resources on Conservation Voltage Reduction (CVR)

Conservation Voltage Reduction (CVR) is one of the cheapest technologies which can be intelligently leveraged to provide considerable energy savings. The addition of renewables in the form of distributed resources can affect the entire power system, but more importantly, affects the traditional substation control schemes at the distribution level. This paper looks at the effect on energy consumption, peak load reduction, and voltage profile changes due to the addition of distributed generation in a distribution feeder using combinations of volt var control. An IEEE 13-node system is used to simulate the various cases. Energy savings and peak load reduction for different simulation scenarios are compared.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Photo-oxidation of semicrystalline polymers: Effect of stress triaxiality on ductility

The effect of stress triaxiality on the strain-to-fracture of as-received and photo-oxidized polyamide-6 (PA-6) was investigated using mechanical testing, synchrotron X-ray tomography, and finite element analyses. Mechanical tests were conducted on cylindrical and round notched specimens, where different notch radii were used to vary the stress triaxiality. The specimens were aged by exposure to ultra-violet (UV) radiation at 60∘, causing photo-oxidation. As-received and so-aged specimens were loaded to failure (complete loss of load carrying capacity). For both unaged and aged specimens, a higher triaxiality led to a lower strain-to-fracture. To elucidate the micromechanical damage that mediates fracture in both conditions, specimens with an intermediate notch sharpness were loaded to the peak load, unloaded, and scanned ex situ using synchrotron X-ray tomography. Damage in the unaged bar was found to occur by cavitation and was concentrated at the center of the specimen, where the triaxiality is highest. In the UV-aged bar, a network of inter-connected chemical cracks were found on the notch surface, where the triaxiality is lowest. Finite element analyses were deployed to approximate the local triaxiality at damaged regions in the unaged and UV-aged specimens using a constitutive relation for semicrystalline polymers. From these analyses, the relationship between local triaxiality and strain-to-fracture was quantified for both unaged and photo-oxidized PA-6. Both unaged and photo-oxidized PA-6 showed similar decreases in ductility with triaxiality, hinting at common ductile fracture processes.

36 MATERIALS SCIENCE↗

Dynamic analysis of Apollo-Salyut/Soyuz docking

The use of a docking-system computer program in analyzing the dynamic environment produced by two impacting spacecraft and the attitude control systems is discussed. Performance studies were conducted to determine the mechanism load and capture sensitivity to parametric changes in the initial impact conditions. As indicated by the studies, capture latching is most sensitive to vehicle angular-alinement errors and is least sensitive to lateral-miss error. As proved by load-sensitivity studies, peak loads acting on the Apollo spacecraft are considerably lower than the Apollo design-limit loads.

Schliesing, J. A.↗

ASPIRE Aerodynamic Models and Flight Performance

NASA's Advanced Supersonic Parachute Inflation Research Experiments (ASPIRE) project was established to test full-scale supersonic parachutes at Mars-relevant conditions, as a risk-reduction activity for NASA's upcomingMars2020 mission. Deployment and inflation of Disk-Gap-Band (DGB) parachutes were examined at Mach number and dynamic pressure conditions relevant to Mars2020, using a sounding rocket platform. The flight tests examined two parachutes: a build-to-print version of the parachute used by the Mars Science Laboratory and a strengthened version of this parachute that has the same geometry but differs in materials and construction. The first flight test (SR01) of the built-to-print parachute took place on October 4, 2017, followed by the first test of the strengthened parachute during flight SR02 on March 31, 2018. A second test of the strengthened parachute with a higher target load, SR03, took place on September 7, 2018. Over the sequence of the three tests, the parachute was exposed to increasing aerodynamic loads with the peak load during SR03 being significantly larger than is expected during a Martian descent. All three tests were successful: the parachute deployment and inflation occurred at the intended conditions, the measurement systems performed as designed and provided the data, and the parachutes survived the aerodynamic loads they were exposed to. The flight tests yielded valuable data on parachute forces and high-speed imagery of the deployment and inflation process.

Parachute↗

California Time-of-Use (TOU) Transition: Effects on Distributed Wind and Solar Economic Potential

Time-of-use (TOU) retail energy rates price electricity differently by the time of day, communicating to consumers the costs of supplying electricity diurnally. This study evaluates the impact of Decision D.15.07-001, which mandates a transition in 2020 to default TOU rates for residential ratepayers in California, on the economic viability of behind-the-meter distributed wind and solar systems. Previous studies have demonstrated that increasing wind and solar generation will materially affect the diurnal cost of wholesale electricity. As retail and wholesale prices become more aligned, this could affect the inter-technology economic viability of distributed generation. We assess economic viability through 'economic potential,' or the amount of generation capacity that exceeds a rate of return of 5.4%. In addition, we identify sensitivities of economic potential to capital costs and other techno-economic factors as well as the specific counties and sectors with substantial economic potential. We find that TOU implementation is projected to moderately increase economic potential of distributed wind and marginally decrease that of distributed solar. Over the long-term as variable renewable energy penetration increases in California, particularly utility-scale solar, net peak load and thus peak prices will shift later in the evening. To the extent that retail rates continue to evolve with wholesale prices, we find the changes could positively affect the value of wind generation more than that of solar generation. Over the scenarios considered, model results indicate realistic pathways to reaching a robust distributed wind market in California though solar economic potential was found to be substantially larger than that of wind.

17 WIND ENERGY↗

Deploying High Penetration Photovoltaic Systems: A Case Study

Photovoltaic (PV) system capacity penetration, or simply 'penetration,' is often defined as the rated power output of the aggregate PV systems on a distribution circuit segment divided by the peak load of that circuit segment. Industry experts agree that a single value defining high penetration is not universally applicable. However, it is generally agreed that a conservative value to designate high penetration is the condition when the ratio of aggregate PV systems ratings to peak load exceeds 15%. This case study illustrates the case of a distribution feeder which is able to accommodate a traditional capacity penetration level of 47%, and perhaps more. New maximum penetration levels need to be defined and verified and enhanced definitions for penetration on a distribution circuit need to be developed. The new penetration definitions and studies will help utility engineers, system developers, and regulatory agencies better agree what levels of PV deployment can be attained without jeopardizing the reliability and power quality of a circuit.

14 SOLAR ENERGY↗

Effects of Home Energy Management Systems on Distribution Utilities and Feeders Under Various Market Structures: Preprint

The combination of distributed energy resources (DER) and retail tariff structures to provide benefits to both utility consumers and the utilities is poorly understood. To improve understanding, an Integrated Energy System Model (IESM) is being developed to simulate the physical and economic aspects of DER technologies, the buildings where they reside, and feeders servicing them. The IESM was used to simulate 20 houses with home energy management systems on a single feeder under a time of use tariff to estimate economic and physical impacts on both the households and the distribution utilities. HEMS reduce consumers’ electric bills by precooling houses in the hours before peak electricity pricing. Household savings are greater than the reduction utility net revenue indicating that HEMS can provide a societal benefit providing tariffs are structured so that utilities remain solvent. Utilization of HEMS reduce peak loads during high price hours but shifts it to hours with off-peak and shoulder prices and resulting in a higher peak load.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Energy, economic, and environmental analysis of integration of thermal energy storage into district heating systems using waste heat from data centres

Data centres produce waste heat, which can be utilized in district heating systems. However, the mismatch between data centres’ heat supply and district heating systems’ heat demands limits its utilization. Further, high peak loads increase the operation cost of district heating systems. This study aimed to solve these problems by introducing thermal energy storages. A water tank and a borehole thermal energy storage system were selected as the short-term and long-term thermal energy storage, respectively. Energy, economic, and environmental indicators were introduced to evaluate different solutions. The case study was a campus district heating system in Norway. Results showed that the water tank could shave the peak load by 31% and save the annual energy cost by 5%. The payback period was lower than 15 years when the storage efficiency remained higher than 80%. However, it had no obvious benefits in terms of mismatch relieving and CO emissions reduction. In contrast, the borehole thermal energy storage increased the waste heat utilization rate to 96% and reduced the annual CO emissions by 8%. However, the payback period was more than 17 years. These results provide guidelines for the retrofit of district heating systems, where data centres’ waste heat is available.

25 ENERGY STORAGE↗

Initial Testing of an In Situ Load Retention Aging Vessel

A thermal aging vessel instrumented with load cells was fabricated. The primary function of the vessel is to continuously monitor the in situ load retention of up to three compressed polymer coupons undergoing thermally accelerated aging under nitrogen. A secondary function is to enable gas sampling of the vessel headspace during thermal aging. Heating of the vessel is achieved using a custom heater jacket. To improve upon our conventional aging study methods which require periodic interruption of aging to perform load testing in an Instron machine at room temperature, this technology aims to automate/facilitate data acquisition/analysis, improve data quality, and enable uninterrupted compression of the polymer which represents the service condition. As an example case to assess functionality of the in situ vessel, the load retention of a siloxane elastomer material additively manufactured by direct-ink-writing (DIW) was measured at three different isothermal aging temperatures for ~1 month. Initial compression of the coupons while near the aging temperature was achieved by temporarily opening the heated vessel to access the interior chamber and manually tightening four nuts to drive the heated compression plate down onto the heated coupons. Initial testing demonstrated achievement of the primary load retention monitoring function. Unfortunately, the vessel leaked which prevented gas sampling; an active purge was used to maintain a nitrogen atmosphere. Welded or otherwise sealed joints, which could be implemented in a future design, would likely eliminate leak paths. To apply time-temperature superposition (TTS), a technique used to provide long-term prediction of the load retention from short-term isothermal data, the load retention needed to be calculated relative to the load at an estimated “equilibrium” time, after most of the transient viscoelastic physical relaxation occurred. The peak load immediately after compression could not be used as the load retention basis for two reasons: (1) age-related changes must be isolated from non-age-related physical relaxation before applying TTS and (2) the manual mechanism used to compress the specimens at the aging temperature was neither smooth nor repeatable which affected the peak load value. To better understand the effect of the mode of initial compression on the measured load, and possibly better estimate “equilibrium” physical relaxation times, systematic stress relaxation experiments were performed using an Instron machine with a thermal chamber. At a given temperature, the DIW polymer was compressed to a fixed strain in either a stepped or continuous manner at two different rates, then held at that strain for 24 hrs. The results indicated that, at a given temperature, the different stress relaxation curves appeared to converge to the same curve at some “equilibrium” time when the non-age-related physical relaxation was mostly complete. Though this observation suggests that the discontinuous manual compression employed by the vessel is feasible, a compression mechanism that is rapid, smooth, and repeatable would enhance its use.

36 MATERIALS SCIENCE↗

Packed Bed thermal storage for compact Light water-cooled Small Modular Reactors

Nuclear power plants (NPPs) have less flexibility to follow grid load demand than their natural-gas fueled counterparts. Most of the natural-gas power plants can supply peak-loads by adding more fuel, and thus, can generate far more revenue during those peak hours. On the other hand, use of NPPs for peak load following is quite complex due to technical constraints associated with reactor behavior. These technical challenges include the adequate handling of reactivity swings caused by time-varying fuel and moderator temperatures, a higher fuel-failure probability due to thermal-structural cycling, and spatial variations in xenon concentration. Although there are presently some reactors around the world that are operating with flexible load-following capabilities, such operation is restricted to slowly-varying powers, 2-3 times a day, and only up to 80% of the fuel cycle. Thus, a more convenient and effective method to facilitate load following by NPPs would be to integrate energy storage Authors have previously developed models and performed exergy analysis for integrating liquid type TES with LWRs and SMRs. These exergy based models show that technical feasibility index of integrating thermal energy storage is very high. But most of these previous studies include integration based on existing layout of NPPs with heat exchange between storage Heat Transfer Fluid (HTF) and Reactor Coolant (RC). However, most of the Light Water-cooled Small modular reactor (LW-SMR) based NPP designs can not accommodate additional heat exchange equipment. Although power production is only reduced to 1/20 scale, the containment volume in thus NuScale LW-SMR is reduced to {approx} 1/170 scale. As steam is the secondary or working fluid which exits out of the reactor containment in LW-SMRs, the simplest and most practical way to integrate thermal storage with LW-SMRs is to directly store the energy from steam. Indirect heat exchange between steam and another heat transfer fluid during the storage process, and then heat recovery again via indirect heat exchange is inefficient process due to heat transfer resistance. This inefficiency is due to what is called as 'Pinch point' which occurs whenever there is indirect heat transfer between two media where one undergoes phase change and other undergoes change in sensible heat. Another existing popular option is to use a steam accumulator which stores dry or wet steam directly inside the pressure vessels, however, due to large volumetric requirements it is not a viable option. This work proposes a new method of integrating packed bed TES systems with LW-SMRs, where steam produced in the secondary side of LW-SMRs can be injected into the packed bed of inert particles with sufficient thermal conductivity and capacity to efficiently store energy with high energy density. The changes in the load demand will not effect the LWSMR operation and the excess steam will be diverted to TES. When the demand increases this stored energy in hot packed beds can be recovered by injecting cold pressurized water. Although there are some existing packed bed TES designs and models which consider steam as HTFs, these models have not been extended for wide range of process parameters important for this integration. Authors have previously developed a packed bed thermal model for steam injection and validated it using experimental data. This thermal model is extended to assess behavior of packed bed thermal energy storage (TES) system under storage and recovery cycles. Steam is the only heat transfer fluid (HTF) which exits the reactor vessel, so any application such as process heat or TES integration should be evaluated with steam as process fluid. This project will develop a process system integration model of LW-SMR with packed bed type TES using steam as HTF. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗