Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “particle improvement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Forwardscattering corrections for optical extinction measurements in aerosol media. II - Polydispersions

The paper presents a parametric study of the forwardscattering corrections for experimentally measured optical extinction coefficients in polydisperse particulate media, since some forward scattered light invariably enters, along with the direct beam, into the finite aperture of the detector. Forwardscattering corrections are computed by two methods: (1) using the exact Mie theory, and (2) the approximate Rayleigh diffraction formula for spherical particles. A parametric study of the dependence of the corrections on mode radii, real and imaginary parts of the complex refractive index, and half-angle of the detector's view cone has been carried out for three different size distribution functions of the modified gamma type. In addition, a study has been carried out to investigate the range of these parameters in which the approximate formulation is valid. The agreement is especially good for small-view cone angles and large particles, which improves significantly for slightly absorbing aerosol particles. Also discussed is the dependence of these corrections on the experimental design of the transmissometer systems.

Deepak, A.↗

A Machine Learning Approach Toward Improving QA/QC of Coated Particle Fuels

Coated particle fuels, such as the tristructural isotropic (TRISO) fuel particle, have been studied and developed for decades for high-temperature gas reactor (HTGR) applications because of their efficiency and relative stability under off-normal conditions. Critical to this development is a strong understanding of the relationship between fuel fabrication, properties and performance, as is how the former can be adjusted and improved to optimize the latter. Accordingly, wide-scale implementation of coated nuclear particle fuels requires thorough and robust quality assurance/quality control (QA/QC) methods for fabrication, characterization, and deployment

Conry, Bryan [ORNL] (ORCID:0000000236089604)↗

Calibrated particle identification for Belle II

We present several efforts aimed at improving charged particle identification at the Belle II experiment. We define an ablation test to quantify and evaluate the impact of each sub-detector on the global particle identification performance. We demonstrate that the performance of the identification scheme can be improved via a simple calibration of the sub-detector likelihoods through a set of per hypothesis, per sub-detector weights. Finally, we present preliminary results on an improved definition of the likelihoods contributed by the electromagnetic calorimeter. A set of multiclass boosted decision trees is trained to exploit the shape of energy depositions of different particle species. In simulated $B\bar{B}$ events, the pion-to-electron and muon fake rates are reduced by 55% and 31% respectively at low-medium momentum.

Hohmann, Marcel [Univ. of Melbourne, Parkville, VI↗

Impacts of Anisotropic Porosity on Heat Transfer and Off-Gassing during Biomass Pyrolysis

The pore structure of biogenic materials imbues the ability to deliver water and nutrients through a plant from root to leaf. This anisotropic pore granularity can also play a significant role in processes such as biomass pyrolysis that are used to convert these materials into useful products like heat, fuel, and chemicals. Evolutions in modeling of biomass pyrolysis as well as imaging of pore structures allow for further insights into the concerted physics of phase change-induced off-gassing, heat transfer, and chemical reactions. In this work, we report a biomass single particle model which incorporates these physics to explore the impact of implementing anisotropic permeability and diffusivity on the conversion time and yields predicted for pyrolysis of oak and pine particles. Simulation results showed that anisotropic permeability impacts predicted conversion time more than 2 times when the Biot number is above 0.1 and pyrolysis numbers (Py 1 , Py 2 ) are less than 20. Pore structure significantly impacts predicted pyrolytic conversion time (>8 times) when the Biot number is above 1 and the pyrolysis number is below 1, i.e., the “conduction controlled” regime. Therefore, these nondimensional numbers reflect that when internal heat conduction limits pyrolysis performance, internal pyrolysis off-gassing further retards effective heat transfer rates as a closely coupled phenomenon. Overall, this study highlights physically meaningful opportunities to improve particle-scale pyrolysis modeling and experimental validation relevant to a variety of feedstock identities and preparations, guiding the future design of pyrolyzers for efficient biomass conversion.

09 BIOMASS FUELS↗

Impacts of Improved Process Representation of Particle Dry Deposition on PM Pollution in a Global Chemistry-Climate Model: Differences Across Regions, Seasons, and PM Sizes

Dry deposition (DD) is a primary removal pathway of particulate matter (PM). The aerosol DD schemes in most global models do not reflect current mechanistic understanding gleaned from observations. The NASA GISS global chemistry-climate model has a new and more dynamic DD scheme that largely captures observed changes in deposition velocities with particle size. We quantify the response of simulated PM to changes in the DD scheme for the Northeast US, Central Europe, North China Plain, and Punjab. Relative to the widely used old scheme, the new scheme shows higher annual PM2.5 for all regions (up to +14%) except C. Europe where there are very small decreases. For PM1, annual increases occur over all regions (up to +20%). For PM10, there are decreases in C. Europe (-8%) and very small decreases in the NE US yet increases (up to +12%) in Punjab and N. China Plain. While there are always increases across seasons for Punjab and N. China Plain, there are both seasonal increases and decreases for the NE US and C. Europe. Given incomplete understanding of observed variations in deposition velocities for a given particle size, we perform sensitivity simulations that perturb the magnitude of the deposition velocities simulated by the new scheme. The annual PM response to increasing DD is similar in magnitude to decreasing DD, implying linearity in the PM sensitivity to DD. The relative annual response to perturbing the DD magnitude is weaker over Punjab and sometimes N. China Plain than the NE US and C. Europe. Higher PM over Punjab and N. China Plain implies a stronger sensitivity to DD when aerosol abundances are low. More mechanistic representation of aerosol DD can sometimes improve or worsen existing model PM biases, which suggests that PM biases due to other processes can be confounded or compounded by biases in DD. Further improvements to DD parameterizations require not only more observational constraints on aerosol deposition velocities but also an advanced understanding of the processes controlling observed variability.

Environmental pollution↗

Evaluating the performance of portable air filter walls for the James Webb Space Telescope launch campaign

The James Webb Space Telescope (JWST) launched from the Centre Spatial Guyanais (CSG) in December 2021. JWST’s requirements permitted processing in International Organization for Standardization (ISO) Class 7 or better facilities, but CSG was only equipped with ISO Class 8 facilities. To temporarily upgrade the air cleanliness in the Payload Processing Facility, Fueling Hall, and Final Assembly Building Encapsulation Hall, NASA provided two portable High Efficiency Particulate Air (HEPA) and carbon filter walls that were used in each location. The walls were comprised of stacks of two modules high and arranged in push-push configurations as shown to be most effective via Computational Fluid Dynamics simulations of expected floor layouts in each facility. After delivery to NASA’s Goddard Space Flight Center in 2020, the walls underwent initial verification measurements inside a cleanroom and validation testing in an uncontrolled area to quantify their improvement of air cleanliness and particle and molecular fallout. Validation testing showed improvements of 83-99% for airborne particle counts, 79-91% for particle fallout, and 50-90% for molecular fallout. The particle improvements were applied to the contamination budget analysis that tracked current and predicted future cleanliness against End-of-Life requirements for JWST’s critical surfaces. At CSG, the walls successfully maintained an ISO Class 7 environment or better within their envelope in each location, despite their presence in ISO Class 8 facilities with dense integration operations.

HEPA, Contamination Control, Filtration↗

Evaluating the Performance of Portable Air Filter Walls for the James Webb Space Telescope Launch Campaign

The James Webb Space Telescope (JWST) launched from the Centre Spatial Guyanais (CSG) in December 2021. JWST’s requirements permitted processing in International Organization for Standardization (ISO) Class 7 or better facilities, but CSG was only equipped with ISO Class 8 facilities. To temporarily upgrade the air cleanliness in the Payload Processing Facility, Fueling Hall, and Final Assembly Building Encapsulation Hall, NASA provided two portable High Efficiency Particulate Air (HEPA) and carbon filter walls that were used in each location. The walls were comprised of stacks of two modules high and arranged in push-push configurations as shown to be most effective via Computational Fluid Dynamics simulations of expected floor layouts in each facility. After delivery to NASA’s Goddard Space Flight Center in 2020, the walls underwent initial verification measurements inside a cleanroom and validation testing in an uncontrolled area to quantify their improvement of air cleanliness and particle and molecular fallout. Validation testing showed improvements of 83-99% for airborne particle counts, 79-91% for particle fallout, and 50-90% for molecular fallout. The particle improvements were applied to the contamination budget analysis that tracked current and predicted future cleanliness against End-of-Life requirements for JWST’s critical surfaces. At CSG, the walls successfully maintained an ISO Class 7 environment or better within their envelope in each location, despite their presence in ISO Class 8 facilities with dense integration operations.

HEPA, Contamination Control, Filtration↗

Improved Limits on Millicharged Particles Using the ArgoNeuT Experiment at Fermilab

A search for millicharged particles, a simple extension of the standard model, has been performed with the ArgoNeuT detector exposed to the Neutrinos at the Main Injector beam at Fermilab. The ArgoNeuT liquid argon time projection chamber detector enables a search for millicharged particles through the detection of visible electron recoils. We search for an event signature with two soft hits (MeV-scale energy depositions) aligned with the upstream target. For an exposure of the detector of 1.0×10 20 protons on target, one candidate event has been observed, compatible with the expected background. This search is sensitive to millicharged particles with charges between 10 -3 $e$ and 10 -1 $e$ and with masses in the range from 0.1 to 3 GeV. This measurement provides leading constraints on millicharged particles in this large unexplored parameter space region.

43 PARTICLE ACCELERATORS↗

Intubation Containment System for Improved Protection From Aerosolized Particles During Airway Management

Worldwide efforts to protect front line providers performing endotracheal intubation during the COVID-19 pandemic have led to innovative devices. Authors evaluated the aerosol containment effectiveness of a novel intubation aerosol containment system (IACS) compared with a recently promoted intubation box and no protective barrier. In a simulation center at the authors’ university, the IACS was compared to no protective barrier and an intubation box. Aerosolization was simulated using a commercial fog machine and leakage of aerosolize mist was visually assessed. The IACS appeared to contain the aerosolized mist, while the intubation box allowed for mist to contact the laryngoscopist and contaminate the clinical space through arm port holes and the open caudal end. Both devices protected the laryngoscopist better than no protective barrier. The IACS with integrated sleeves and plastic drape appears to offer superior protection for the laryngoscopist and assistant providers from aerosolized particles.

aerosols↗

Fine-tuning of process conditions to improve product uniformity of polystyrene particles used for wind tunnel velocimetry

Monodisperse polymer particles (having uniform diameter) were used for the last two decades in physical, biological, and chemical sciences. In NASA Langley Research Center monodisperse polystyrene particles are used in wind tunnel laser velocimeters. These polystyrene (PS) particles in latex form were formulated at the Engineering Laboratory of FENGD using emulsion-free emulsion polymerization. Monodisperse PS latices particles having different particle diameters were formulated and useful experimental data involving effects of process conditions on particle size were accumulated. However, similar process conditions and chemical recipes for polymerization of styrene monomer have often yielded monodisperse particles having varying diameters. The purpose was to improve the PS latex product uniformity by fine-tuning the process parameters based on the knowledge of suspension and emulsion polymerization.

Ray, Asit K.↗

Cloud microstructure as determined by an optical cloud particle spectrometer.

Use of an improved single-particle light-scattering instrument for measurement of cloud microstructure in field studies. Cloud particle size and number information is measured over 12 sizing intervals, in the range from 4 to 85 microns in diameter. The microstructure can be observed in real time and with a spatial resolution not previously reported. The general features of water cloud droplet size and number distributions are consistent with previous direct capture and replication studies. The transition from water to ice phase regions in cumuliform clouds can be inferred from dramatic changes observed in the distribution features. Results are also presented for stratus and cirrus cloud penetrations.

Ryan, R. T.↗

Gas-Particle Interaction Model Development in Plume Surface Interaction Erosion and Cratering

The development of a predictive simulation capability for extra-terrestrial Plume Surface Interaction (PSI) environments is undertaken by the Fluid Dynamics Branch at NASA/MSFC under the Game Changing Development (GCD) Program funded by NASA’s Space Technology Mission Directorate (STMD). Predictive simulation capability for propulsive Martian and Lunar landing PSI requires accurate modeling of the complex high-speed plume impingement and resulting gas/particle-cloud and ejecta stream formation. Physics modeling gap analysis during formulation of the PSI project scope identified two particular phenomena of first order importance in gas-particle interactions that lacked existing modeling formulations. The first arises from the lack of models capturing the unsteady drag forces imparted on particles by the rapidly expanding supersonic compressible flow. The second addresses the fluctuating forces and dispersions imparted on both the particle and the fluid resulting from the interference and wake turbulence generated by close proximity particle clouds, dubbed the Particle Turbulent Kinetic Energy(PTKE). Their first order significance has been identified in experiments, but simulation models currently do not exist for either effect. The development of models and the eventual implementation into the Eulerian Gas-Granular Flow Solver (GGFS) simulation tools was constructed as one of four major tasks of the PSI project. In this process, data on particle kinetics and gas-particle interactions are collected from carefully designed experiments of particles embedded in jets. The effects observed in the experiments are then replicated in high-fidelity particle-resolved CFD simulations to inform the formulation of improvements to particle phase drag models for implementations in the more efficient Eulerian-Lagrangian CFD simulations. The resulting models are ultimately ported to the Eulerian-Eulerian models applied for most efficient simulations in PSI production application tools. This paper describes the activities and accomplishments of the past year in the gas-particle interaction modeling task of the PSI project.

Jeff West↗

Astrophysical data on 5 eV to 1 keV radiation from the radiative decay of fundamental particles - Current limits and prospects for improvement

Line emission from the decay of fundamental particles, integrated over cosmological distances, can give rise to detectable spectral features in the diffuse astronomical background between 5 eV and 1 keV. Spectroscopic observations may allow these features to be separated from line emission from the numerous local sources of radiation. The current observational status and existing evidence for such features are reviewed. No definitive detections of nongalactic line features have been made. Several local sources of background mask the features at many wavelengths and confuse the interpretation of the data. No systematic spectral observations have been carried out to date. Upcoming experiments which can be expected to provide significantly better constraints on the presence of spectral features in the diffuse background from 5 eV to 1 keV are reviewed.

Bowyer, Stuart↗

Performance in beam tests of irradiated Low Gain Avalanche Detectors for the ATLAS High Granularity Timing Detector

The High Granularity Timing Detector (HGTD) will be installed in the ATLAS detector to mitigate pile-up effects during the High Luminosity (HL) upgrade of the Large Hadron Collider (LHC) at CERN. The design of the HGTD is based on the use of Low Gain Avalanche Detectors (LGADs), with an active thickness of 50 μm, that allow to measure with high-precision the time of arrival of particles. The HGTD will improve the particle-vertex assignment by measuring the track time with a resolution ranging from approximately 30 ps at the beginning of the HL-LHC operations to 50 ps at the end. Performances of several unirradiated, as well as neutron- and proton-irradiated, LGAD sensors from different vendors have been measured in beam test campaigns during the years 2018 and 2019 at CERN SPS and DESY. This paper presents the results obtained with data recorded by an oscilloscope synchronized with a beam telescope which provides particle position information within a resolution of a few μm. Collected charge, time resolution and hit efficiency are presented. In addition to these properties, the charge uniformity is also studied as a function of the position of the incident particle inside the sensor pad.

47 OTHER INSTRUMENTATION↗