Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “parabolic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Hybrid Solar System (Final Scientific/Technical Report)

GTI Energy (GTI) teamed with the University of California at Merced (UCM) to scaleup the hybrid solar system (HSS) technology for demonstrating its performance at the US Gypsum (USG) plant in Plaster City, California. The technology integrates two-stage concentrating solar collector with matching particle thermal transport and storage (TSS) system to deliver cost-effective, and on-demand distributed high temperature industrial process heat up to 600°C with solar thermal, in this case to a gypsum kettle, to reduce its fuel use and carbon footprint. Current solar technologies, which reach these temperatures, are not distributable (towers) or cost-effective (dish). The research team developed a conceptual system design for host site retrofit, including preliminary heat balance, process flow diagram, particle to process heat exchanger and equipment placements at the site. Subsequently, parallel efforts were carried out at UCM to design, build and test a 12 m long commercial scale prototype concentrating thermal-only collector system and at GTI to design, build and test a matching 650°C capable particle TTS system. The nominal 50 kWth collector consists of a parabolic trough and three 4 m long two-stage receivers in series. Prior to on-sun testing, a 4 m long receiver was fabricated and successfully tested at 650 °C in a laboratory setting for 100 hrs of continuous operation showing less than 15% radiation loss. A 7 m wide x 17 m long parabolic trough was then installed at UCM for on-sun testing of the 12 m long receiver, and concurrently several 4 m long receivers were built. The optics of the parabolic trough were calibrated, and on-sun test were carried out on 12 m long receivers. During tests, the intense solar radiation (53x) caused the absorber tubes in the receivers to bend, reducing the overall optical efficiency. To address the bending issue, a self-consistent algorithm that includes ray tracing, thermal and deformation models was developed to perform thermal stress analysis on absorbers for parabolic solar collectors. Results obtained with this algorithm showed a dramatic rise in deformation as absorber tube length increases. A combined efficiency parameter that includes the occluded area for the mounts was developed to obtain an optimized tube length obtained. Based on the results, a length of 2.7 m for the absorber + 0.2 m for the coupler was chosen to minimize any bending and optimize optical efficiency while maintaining ease of mounting. The associated particle TTS system was designed, built and successfully tested at GTI. It includes storage, receiving and lock hoppers and piping that simulates the transfer of captured solar energy to an actual industrial furnace. Tests over 77 charge-discharge cycles demonstrated <2% particle degradation, with no problematic particle accumulations and no flow interruptions. The piping pressure drop was about 5 psi. The team also worked with Stanley Consultants (Stanley) to prepare conceptual and preliminary engineering packages to facilitate follow-on development and commercialization efforts. These include process and instrumentation diagram’s (P&ID’s), general arrangements, electrical one-line, project definitions document, equipment data sheets, schedule, and construction cost estimate for 2 MWth system. Updated HSS technology commercialization and customer engagement plans and detailed costs and evaluated market trade-offs and manufacturing.

03 NATURAL GAS↗

Assessing the Optical Performance Impact of Tracking Error in an Operational Concentrated Solar Power Plant Using Monte Carlo Ray-Tracing Simulation

Concentrating Solar Power (CSP) provides firm and dispatchable electricity due to its thermal storage and hybridization capabilities, which supports the decarbonization of our energy supply. Of the various CSP technologies, parabolic trough collectors are the most mature, with over 500 MW operating worldwide. The optical performance of parabolic trough systems is sensitive to tracking error, which is defined as the angular offset of a collector away from the sun position in the transversal plane. Tracking error commonly occurs due to non-continuous adjustment of the trough angle to point toward the sun, but other factors such as gravity, heating, and wind loading can also contribute to tracking error. Researchers have explored the impact of tracking error on optical performance both numerically and experimentally, but existing studies do not include measurements from operational utility-scale power plants. Tilt angle measurements of parabolic troughs at operational utility-scale power plants illustrate spatial variations in optical performance and include various sources of tracking error such as gravity, heating, and wind loading. To fully characterize wind driven loads on parabolic troughs, we are conducting a long-term field measurement campaign at the Nevada Solar One CSP plant located in Boulder City, NV, which has a nominal capacity of 72 MW and 0.5 hours of full-load storage. We record load measurements on four outer trough rows, collecting support structure bending moments, drive torque moments, dynamic accelerations of the spaceframe, mirror displacement, and tilt angles. Using the tilt measurements acquired at 20 Hz frequency, we calculate the deviation between the nominal sun position and the tracker angle. Using a Monte-Carlo ray-tracing simulation software, we assess the impact of the tracker angle deviation on optical performance throughout the diurnal cycle at various spatial locations within the CSP plant. In our view, this first-of-a-kind study will provide important guidance for future trough designs that reduce the impact of various sources of tracking error on performance.

concentrating solar power↗

Dynamic Wind Loading on CSP Collectors Caused by Turbulent Wind Fluctuations: Insights from a 2-Year Field Campaign

Concentrating Solar Power (CSP) is a promising solar technology for electricity generation with thermal energy storage and with the additional benefit of industrial heat production. Wind loading on CSP collector structures, such as parabolic troughs or heliostats, is one of the primary drivers of their structural design costs. In particular, dynamic wind loading is a major source of uncertainty in the collector design process, which heavily relies on wind tunnel testing. In the field, the turbulent nature of the incoming wind creates fluctuating loads (support structure loads and resulting mirror deflections) on the collectors, with impacts on fatigue lifetime and optical performance. As is well known, wind tunnel tests cannot entirely reproduce the complex turbulent wind conditions typically observed at full-scale plants. To shed light on this topic, NREL initiated a field campaign at the operational Nevada Solar One (NSO) powerplant that uses parabolic troughs as solar collectors. The aim of the project is a detailed characterization of prevailing wind and turbulence conditions and resulting operational loads on parabolic troughs. We use the published 2-year dataset of high-resolution combined wind and structural loads measurements [1] to characterize the dynamic structural wind response. For quantifying dynamic wind loading, we apply the concept of admittance functions, which are spectral transfer functions that couple the turbulent wind to resulting structural loads (aerodynamic admittance), and to the structural response (mechanical admittance). In practice, aerodynamic admittance describes which turbulent eddy sizes are effective in creating structural loads. The mechanical admittance describes in which frequency ranges these loads are reinforced or dampened by the structure. While these functions are an established concept in civil engineering, their recent application to a single full-scale heliostat [2] proved their broader applicability to CSP collectors. Here, we present a characterization of admittance functions for full-scale parabolic trough collectors and show how wind characteristics (mean wind speed and direction, turbulent kinetic energy, turbulent length scales), the sun-tracking trough angle, and row position alter the admittance functions. Further, we study to which extent the admittance functions are universal for a specific trough geometry and how our findings compare to reported heliostat results. References [1] https://data.openei.org/submissions/5938. [2] Blume, K., Roger, M., and Pitz-Paal, R. 2023b. "Simplified analytical model to describe wind loads and wind-induced tracking deviations of heliostats." Solar Energy, 256, 96-109. https://doi.org/10.1016/j.solener.2023.03.055.

admittance functions↗

Wind Loading on CSP Collectors

The project significantly enhanced the community's understanding of the fundamental physics drivers underlying the wind-loading experienced by concentrating solar power (CSP) collector structures (i.e., parabolic troughs and heliostats) as well as their support structures. This project had two overarching objectives: (1) detailed measurements to characterize the prevailing wind conditions and resulting operational loads on collector structures, and (2) development and validation of a computationally efficient, high-fidelity modeling tool capable of predicting wind-loading in deep-array installations. Over three years, we conducted comprehensive at-scale field measurements of the atmospheric turbulent wind conditions, and the resulting wind loads on parabolic troughs and heliostats. Two at-scale measurement campaigns yielded first-of-its-kind, high-resolution, long-term datasets that are used to characterize the complex flow field and wind loading on parabolic-troughs and heliostats in operational power plants. The high-resolution measurements collected during these campaigns were used to validate the high-fidelity computational models developed at NREL. These open-source computationally efficient models were shown to be accurate in predicting wind-driven loads on collectors without the need for a large supercomputer.

14 SOLAR ENERGY↗

Design Basis Document / Owner’s Technical Specification for Nitrate Salt Systems in CSP Projects (Final Technical Report)

The number of commercial coal, gas, and nuclear projects built over the past 100 years number in the thousands. As such, there is a large database, available to a wide range of commercial engineering contractors, on proven designs. In essence, unsuccessful designs have, through generations of iterations, been identified and then deleted from further consideration. In contrast, the number of commercial parabolic trough projects using nitrate salt for the thermal storage media is perhaps 60. Further, the number of commercial central receiver projects using nitrate salt as the working fluid is on the order of 20, including estimates for China. Given the relative immaturity of salt technology, and commercial pressures to successfully bid new solar projects into a mature electricity market, solar projects often promise more than has been delivered. The Design Basis Document / Owner’s Technical Specification is a first step in the iteration process. The report describes the successful features of commercial projects, outlines a range equipment and system failures in projects that didn’t operate as intended, and provides a draft set of design changes intended to correct the known problems. The product of the study is 3 volumes of technical material; one volume is on parabolic trough technologies; a second is on central receiver technologies, and the third is on potential design changes to parabolic trough and central receiver projects. The 3 volumes, which total some 590 pages, can be found at https://www.solardynllc.com/csp-plant-technologies. One of the principal topics in the report is the use of functional or prescriptive specifications. Functional specifications describe what the equipment needs to do, consistent with the minimum legal requirements of the local jurisdictions. The details of how this is to be accomplished is developed by the engineering contractor. Prescriptive specifications, which are developed by the Owner, prescribe to the engineering contractor how the functional requirements are to be met. This arrangement ensures that the favorable experience from a previous project is repeated. One example is the design code for the hot salt tank in central receiver projects. The closest design basis is API Standard 650 Welded Steel Tanks for Oil Storage. However, the maximum design temperature in API 650 is 260 °C. As such, solar projects have typically adopted a hybrid Code approach, in which allowable material stresses are taken from ASME Section II Materials. Further, since the tanks experience daily changes in temperature and in (static) pressure, and since portions of the tank can operate at stresses beyond the elastic range, the low cycle fatigue life of the tank is conducted using the rules of Section VIII Division 2. However, in a recent study by NREL, the principal damage mechanism was identified as creep rather than fatigue. Further, design stresses permitted under Section VIII Division 2, corresponding to a fatigue life of 30 years, result in projected creep lifetimes of only 2 to 5 years. An alternate design approach, prescribed by the Owner, would be based on Code sections intended for high temperature service in the creep regime. A candidate is Section III Division 5. Granted, this is a nuclear code section, and it’s use would not likely be mandated by local jurisdictions. However, the effects of creep have been deemed to be of sufficient importance that one nuclear project developer, and one central receiver project developer, have stipulated in the tank design specification that the equipment be designed to the requirements of Section III Division 5.

14 SOLAR ENERGY↗

Distant Observer™ [SWR-12-09]

Distant Observer™ (DO) is an optical measurement tool, designed for parabolic trough solar collectors, that determines reflector slope error, absorber position error, and the combined errors based on images of the receiver-tube reflection taken from different angles. We have demonstrated that DO can provide a measurement accuracy of 0.25 mrad for the slope and receiver position errors. DO has two implementation versions: ground-based and drone-driven. As we pursue efforts to lower the capital and installation costs of parabolic trough solar collectors, it is essential to maintain high optical performance. The Distant Observer™ (DO) tool, developed by engineers at NREL, is a fast and highly accurate tool that provides complete characterization of the performance of the optical components which include the mirror panels and thermal receiver. This tool is very useful for testing both prototype and operational modules. The Distant Observer™ is an optical measurement tool for parabolic solar collectors that measures reflector slope error, absorber position error and the combined errors. Reflector slope errors occur for many reasons including imperfection in structural frame design, manufacturing and assembly. Absorber position error can be caused by poor structural design, poor installation, sag from the absorber weight, or change in the structure over time.

Ihas, Benjamin↗

Acciona Power Plant Hydrogen Mitigation Project

In 2014, Acciona Solar Power and the National Renewable Energy Laboratory initiated discussions to identify a method to solve a long-standing efficiency loss problem at parabolic trough power plants. Parabolic trough power plants begin to show lost thermal efficiency after six years of operation, due to the presence of trace concentrations of hydrogen in the heat transfer fluid that circulates in the power plant. Trace levels of hydrogen infiltrate the collector field receivers, increasing their heat loss, and decreasing the power plants’ thermal efficiency. At the time, Acciona’s Nevada Solar One power plant in Boulder City, Nevada was starting to show this efficiency loss. After several discussions, APS and NREL agreed to a collaborative effort (CRADA) to develop and implement a method to reduce hydrogen levels in the circulating HTF at the NSO power plant. The project was planned as a three-year effort, and work started in June 2015. The CRADA’s goal was to solve the long-standing lost efficiency problem caused by the buildup of hydrogen in the HTF, which significantly impacts the efficiency, electricity generation, and revenue from parabolic trough power plants.

08 HYDROGEN↗

High-Entropy Ceramic Coatings: Transformative New Materials for Environmentally-Compatible Thin-Film Insulators against High-T Molten Salts

An emerging new class of promising materials, High-Entropy Ceramics (HECs) or Compositionally-Complex Ceramics (CCCs), have been successfully fabricated in the last three years. This project evaluates HECs/CCCs in the concentrated solar power (CSP) context. In this project, we have identified a couple of simple, and key descriptors governing thermal conductivity in HECs. Size disorder among the cations was found to have a strong influence on the thermal conductivity across multiple systems and throughout a vast compositional space. Since identifying this, we have optimized previous compositions to achieve low thermal conductivities of $k$~$1-1.4Wm{-1}K{-1}$. We have further reduced our selection of promising compositions based on project guidelines and applied a theory that can potentially predict reactivity with molten salts to identify a small set of HECs that are suitable for further molten salt heat transfer media (HTM) stability testing. Many compositions reveal poor resistance to molten chloride salt after being exposed for 24 h compared to the reference structural alloy, Haynes 230. However, after 100 h, a few HECs/CCCs show strong parabolic rate constant effects and provide greater resistance to chloride salt compared to Haynes 230 alloy, which shows more linear kinetics. Postmortem characterization of the microstructure reveals the parabolic rate constant originates from a dense reaction layer form at the interface. This feature is absent in Haynes 230, which only shows grain boundary infiltration. The HECs/CCCs were also put in contact with the metal alloy under Ar for 800 h at 800°C and show negligible interaction. Lastly, parabolic rate constant HECs/CCCs also have low thermal conductivity $(<2 Wm^{-1} K^{-1})$ at 800°C. These specimens satisfy all project requirements and demonstrate their promising application in next-generation CSP.

14 SOLAR ENERGY↗

Coherent transverse instability of bunched beams in circular accelerators

Coherent transverse oscillations of a bunch in a ring accelerator are considered. Three different models of the bunch are used: a hollow bunch in a square potential well, a square bunch in a parabolic potential well, and a parabolic bunch in a parabolic well. The bunch space-charge field, wakefield, and chromaticity are taken into account in all the cases. The bunch eigenmodes and various instabilities are studied. The results are compared and analyzed to establish the range of applicability of the models. Role of the Landau damping due to dependence of the SC field on the longitudinal coordinate is discussed.

43 PARTICLE ACCELERATORS↗

Studying Wind Loading on CSP Collectors to Improve Performance and Reliability

Electricity generation through Concentrating Solar-thermal Power (CSP) adds the advantage of thermal energy storage and heat production. CSP collector costs constitute nearly one-third of total plant costs. Managing wind loading, especially dynamic wind loading caused by the turbulent wind flow, is a significant design challenge. Traditional collector designs rely on wind tunnel experiments and numerical simulations, which do not fully capture dynamic effects. Here, we provide an overview of NREL's activities on wind loading on CSP collectors, aiming to improve their reliability and cost-efficiency. We present insights from field measurements at operational parabolic trough and power-tower CSP plants. Over two years, we measured turbulent wind fields and resulting structural loads in a parabolic trough plant, revealing wind, turbulence, and collector field interactions. Similar measurements are ongoing at the Crescent Dunes heliostat field. These campaigns show how atmospheric turbulence, wind direction, and collector orientation affect dynamic wind loading. Upwind collector structures can generate turbulent structures, causing fluctuating loads at downstream collectors, impacting fatigue lifetime and optical efficiency. Preliminary results indicate that interior collectors experience higher turning moments than those at the edges, suggesting higher drive wear. At Crescent Dunes, we use instrumented heliostats at the field's edge and interior to study the translation of turbulent wind to dynamic structural loads. The campaign is still ongoing, and we will present first findings. Another focus of our work is tying the experimental wind loading findings to optical performance of the collectors, using simulation tools. For example, we derive torsional errors of the parabolic troughs - the angular offset from the sun position along a collector row. This error is impacted by wind-induced mirror deformations. Future work will focus on continuing the measurement efforts and combining them with computational fluid dynamic simulations. By providing detailed field measurements and validated models, our efforts aim to enhance understanding of wind loading on CSP collectors, improving their structural integrity and optical performance.

CSP↗

Spontaneous Exciton Collapse in a Strongly Flattened Ellipsoidal InSb Quantum Dot

Abstract Electronic and excitonic states in an InSb strongly flattened ellipsoidal quantum dot (QD) with complicated dispersion law are theoretically investigated within the framework of the geometric adiabatic approximation in the strong, intermediate, and weak quantum confinement regimes. For the lower levels of the spectrum, the square root dependence of energy on QD sizes is revealed in the case of Kane’s dispersion law. The obtained results are compared to the case of a parabolic (standard) dispersion law of charge carriers. The possibility of the accidental exciton instability is revealed for the intermediate quantum confinement regime. For the weak quantum confinement regime, the motion of the exciton's center-of-gravity is quantized, which leads to the appearance of additional Coulomb-like sub-levels. It is revealed that in the case of the Kane dispersion law, the Coulomb levels shift into the depth of the forbidden band gap, moving away from the quantum confined level, whereas in the case of the parabolic dispersion law, the opposite picture is observed. The corresponding selection rules of quantum transitions for the interband absorption of light are obtained. New selection rules of quantum transitions between levels conditioned by 2D exciton center of mass vertical motion quantization in a QD are revealed. The absorption threshold behavior characteristics depending on the QDs geometrical sizes are also revealed.

97 MATHEMATICS AND COMPUTING↗

Concentrating Solar Power Best Practices Study

The primary objective of this Concentrating Solar Power Best Practices Study is to publish best practices and lessons learned from the engineering, construction, commissioning, operations, and maintenance of existing concentrating solar power (CSP) parabolic trough and power tower systems. To accomplish this objective, information was solicited from many owners, operators, and engineering, procurement, and construction (EPC) contractors, independent engineers, and other stakeholders of parabolic trough and central receiver plants (also commonly referred to as power towers). Information was gathered through in-person or online meetings, site visits, and questionnaires sent to participants. The project team held about 50 information-gathering sessions with participants over the course this effort; and in the process, it collected information from participants representing nearly 80% of CSP plants operating worldwide.

14 SOLAR ENERGY↗

Optimizing multigrid reduction-in-time and Parareal coarse-grid operators for linear advection

Parallel-in-time methods, such as multigrid reduction-in-time (MGRIT) and Parareal, provide an attractive option for increasing concurrency when simulating time-dependent partial differential equations (PDEs) in modern high-performance computing environments. While these techniques have been very successful for parabolic equations, it has often been observed that their performance suffers dramatically when applied to advection-dominated problems or purely hyperbolic PDEs using standard rediscretization approaches on coarse grids. In this paper, we apply MGRIT or Parareal to the constant-coefficient linear advection equation, appealing to existing convergence theory to provide insight into the typically nonscalable or even divergent behavior of these solvers for this problem. To overcome these failings, we replace rediscretization on coarse grids with improved coarse-grid operators that are computed by applying optimization techniques to approximately minimize error estimates from the convergence theory. Therefore, one of our main findings is that, in order to obtain fast convergence as for parabolic problems, coarse-grid operators should take into account the behavior of the hyperbolic problem by tracking the characteristic curves. Our approach is tested for schemes of various orders using explicit or implicit Runge–Kutta methods combined with upwind-finite-difference spatial discretizations. In all cases, we obtain scalable convergence in just a handful of iterations, with parallel tests also showing significant speed-ups over sequential time-stepping.

97 MATHEMATICS AND COMPUTING↗

Correlations of the Steam Oxidation Rate Constant of BWR Alloy Zircaloy-2 at 800–1400 °C

Steam oxidation experiments were conducted at 800–1400 °C with boiling water reactor alloy Zircaloy-2 strip specimens. Sample weight gain measurements were performed on the oxidized specimens before and after the test and were compared to oxygen pickup calculations using the Cathcart–Pawel correlation. The results showed that Zircaloy-2 follows the parabolic law at temperatures above 1000 °C. At or below 1000 °C, the oxidation rate was very low when compared to Cathcart–Pawel correlation and can be represented by a cubic expression. Arrhenius expressions are given to describe the parabolic rate constants at temperatures above 1000 °C and cubic rate constants are provided for temperatures at or below 1000 °C. Here, the weight gains calculated by our Arrhenius correlations are in excellent agreement with the measured sample weight gains at all test temperatures.

36 MATERIALS SCIENCE↗

Stochastic Model for High Temperature Oxidation of Cr–Ni Austenitic Steels Assisted by Spallation

Abstract Cr–Ni austenitic steels offer significant high temperature corrosion protection by forming a surface oxide layer. However, above critical service conditions (temperature, atmosphere, thermal cycling), oxidized surface can experience intensive degradation because of scale spallation, which could be detrimental to the in-service life. To predict the effect of scale spallation on oxidation kinetics, a simulation was implemented using a stochastic model. The model considers topological parameters and intensity of spallation which can occur, while delivering a true oxidation constant. The experimental procedure identified the amount of formed spalled scale and topology of spallation based on the use of element mapping of the surface. This information was used to determine a true kinetic constant for a corresponding spallation intensity in oxidized Cr–Ni austenitic steel. To illustrate the capability of the stochastic model, a parametric analysis was performed. The model verified how the spallation parameters could change the oxidation processes from parabolic growth of an adhered oxide layer without spallation to a mixed linear-parabolic, or with a constant thickness of residual scale at high spallation intensity. The spallation model will be used in a separate article to characterize high temperature surface degradation of several Cr–Ni austenitic steels during harsh oxidation environments.

36 MATERIALS SCIENCE↗

In-situ ETEM study of plasma-facing tungsten nanofuzz oxidation at atmospheric pressure: Microstructure evolution and substrate-free oxidation kinetics

To enable sustainable carbon-free fusion energy, managing reactor structural material degradation during normal operation as well as accident scenarios is vital. Tungsten (W) plasma-facing materials (PFMs) are susceptible to aggressive high-temperature oxidation during air-ingress fusion reactor accidents, yet there's a lack of oxidation kinetic data for irradiated tungsten. Here, in this study, we utilize atmospheric environmental transmission electron microscopy (ETEM) to present the first kinetic data for substrate-free W nanofuzz oxidation at 400 ºC and 500 ºC in 1 bar dry air. Comparison with pristine bulk W during the early parabolic stage suggests an irradiationdecelerated oxidation for W nanofuzz. Our time-resolved in-situ characterization reveals a durable amorphous surface oxide, likely promoted by high-flux He + irradiation-induced surface defects, serving as an effective passivating layer that impedes nanofuzz oxidation onset. This surface oxide layer also interfaces well with newly formed orthorhombic WO 3 , facilitated by stress relief through He bubble shrinkage, providing lasting passivating protection throughout the nanofuzz parabolic oxidation. This new finding challenges conventional notions of irradiation's negative impact on metal oxidation, and calls for advanced characterization to enhance our understanding of fusion energy materials degradation, informed by further accident modeling.

36 MATERIALS SCIENCE↗

Corrosion of Al 2 O 3 /Cr and Ti 2 O 3 /Cr composites in flowing air and CO 2 at 750°C

Hot-pressed Al 2 O 3 /Cr and Ti 2 O 3 /Cr composites were exposed to synthetic air or CO 2 at 750 °C. The Al 2 O 3 /Cr composites formed external Cr 2 O 3 scales, and exhibited slow parabolic oxidation kinetics, in both gases. The Cr 2 O 3 scales formed in CO 2 possessed finer grains, and thickened at a faster rate, than Cr 2 O 3 scales formed in air. The Ti 2 O 3 /Cr composites formed thick external TiO 2 scales with internal oxidation zones that also contained Cr 2 O 3 scales on subsurface Cr grains. After 20 h at 750 °C, the Ti 2 O 3 /Cr composites exhibited parabolic oxidation kinetics in both gases, although the oxidation rates were significantly higher than for the Al 2 O 3 /Cr composites.

36 MATERIALS SCIENCE↗