Engineering PapersSearch

SEARCH · Engineering Papers

Results for “outage management system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

74 records · Page 5

Supporting Hazard Analysis for Wildfire Response Using fmdtools and MIKA

The System Wide Safety (SWS) Safety Demonstrator (SD) Series drives development of an increasingly capable In-Time Aviation Safety Management System (IASMS) focusing on humanitarian applications, starting with wildfire response (SD-1). The goals of this report are to (1) provide an early hazard analysis and mitigation evaluation of wildfire response to support these efforts and (2) provide a demonstration of capabilities of the Fault Model Design Tools (fmdtools) and Manager for Intelligent Knowledge Access (MIKA) tools. fmdtools provides a modeling, simulation, and resiliency analysis framework in which a wildfire response model, the System Modeling and Analysis of Resiliency in Scalable Traffic Management for Emergency Response Operations (SMARt-STEReO), is built. MIKA is an intelligent knowledge manager with several capabilities, including assisting in hazard analysis by extracting and analyzing hazards from historical incident reports. The following topics are covered in the report: Understanding Wildfire Hazard Dynamics. We provide a description and simulated examples of how hazards occur in the SMARt-STEReO model of wildfire response and their effect on its outcome. This provides a common mental model and focuses the analysis presented in the remainder of the report. Wildfire Hazard Identification. MIKA identifies wildfire hazards from three relevant datasets: the ICS-209-PLUS, SAFECOM, and SAFENET. Hazards are manually organized into a taxonomy and MIKA analyzes each hazard’s effects, likelihood, severity, and risk. Evaluating Mitigation Strategies. The SMARt-STEReO wildfire response model built in fmdtools evaluates a subset of identified hazards. Specifically, we simulate the effect of communications faults and equipment faults on operator safety, the effect of changing winds and flammability, and a scenario with multiple ignition points and heavy smoke. Tool Limitations and Usage Considerations. We provide a discussion of appropriate tool use cases as well as limitations and considerations for usage. The tool findings are used to synthesize recommendations for wildfire response operations, which can be captured as part of an IASMS. Key recommendations are as follows: Hazards are identified from a broad spectrum of sources including aircraft subsystems, operational sources, and ground crew operations. Highest risk operational environment hazards identified are Evacuations. The highest risk manned aerial operations hazard categorized is Jumper Operations Mishap. Ground crew hazards that are highest risk are Burns, Cargo Operations Overhead, Dehydration, Entrapment, Falling Objects, Heart Attacks, Heat Exhaustion, Inadequate Training or Certification, Vehicle Breakdown, and Vehicle Collision. Modelled containment failures arise from a mismatch between the difficulty of the firefighting scenario and the capacity (e.g., speed, effectiveness, awareness) of the response. In firefighting scenarios where containment is possible (e.g., because the fire does not spread too quickly), these mismatches can occur because of a change in environmental conditions (e.g., wind, flammability, etc) or because of planning, equipment, or communications faults. Improvements to communications increase the capacity of the firefighting response by reducing the time needed to respond to the fire. While surveillance does not increase this capacity by itself, it increases operator safety by increasing state awareness, enabling firefighters to evade approaching fires. Increasing both has a synergistic effect. In general, these performance and resilience increases generalize over fault scenarios as well as unforeseen changes to circumstances (i.e., wind, aridity, etc.). However, these improvements need to be designed so as not to make the system prone to persistent large-scale communications outages, which can reduce performance.

Hazard analysis

Corrosion Testing of Refractory inContact with Molten Glasses Designed for Waste Vitrification - VSL Touchpoint Matrix Glasses

It is known that the predictive life of the refractory ceramic liner of nuclear waste glass melters is conservative, as demonstrated by performance of these materials such as in the Defense Waste Processing Facility (DWPF). The motivation for this task is to maximize the useful life of the melters that will be operated at the Waste Treatment and Immobilization Plant (WTP), which will in turn minimize procurement and disposal costs and melter outage times, as well as to identify maximum loadings in the waste glass of those species that corrode melter components. This task was initiated jointly with Pacific Northwest National Laboratory (PNNL) with the objective to develop a methodology and model to enable more accurate prediction of refractory service life under prototypic conditions from laboratory-scale material corrosion tests. Refractory corrosion is generally reported as physical material loss, measured in units of distance (e.g., inch) or as physical material loss rate, measured in units of distance per time (e.g., inch/day). In post-operational melters, the refractory corrosion is measured directly, sometimes reported as corrosion depth. Crucible tests are used in the laboratory to accelerate the refractory corrosion to facilitate a meaningful measurement in a commensurate amount of time. Crucible tests are particularly useful in understanding refractory corrosion across a large glass composition space, where operational testing would be prohibitive. Some of the critical parameters that are known to influence refractory corrosion by molten glass in a crucible test are temperature, system redox, molten salt phases, glass chemistry, and test duration. The majority of data collected for Monofrax® K-3 (hereafter referred to as K-3) corrosion is from crucible tests, but a small amount comes directly from scaled and production melters. Crucible test data has been collected under varying conditions, whereas data collected from operational melters is relatively fewer and represents conditions specific to the melter campaign. The result is that the published data can be grouped and analyzed in multiple ways, not all of which are readily comparable. The Standard Test Method for Isothermal Corrosion Resistance of Refractories to Molten Glass (ASTM C621) outlines the general guidelines used across industry. That method describes a sealed, static test in which the surface area of the refractory coupon and the volume of glass are fixed. A significant portion of the crucible data pertaining to nuclear waste glasses has been collected in a modified configuration; the most notable differences being the surface area of the refractory coupon to volume of the glass and use of a method for bubbling the melt. To our knowledge, the influence of those parameters on the refractory corrosion has not been quantified. In this work, it was determined that static tests and bubbled tests would be performed. Savannah River National Laboratory (SRNL) was tasked with setting up and performing static testing while PNNL was tasked with setting up and performing bubbled testing. Initial activities were performed to establish laboratory methods that reproduce data comparable to existing data sets of K-3 refractory corrosion by low activity waste (LAW) and high-level waste (HLW) glass compositions. Later activities were focused on refining the test parameters to establish a standard test practice to be used between Laboratories and collecting additional data to be used in the enhanced waste glass model development. This document serves primarily to convey the refractory loss measurement results from corrosion testing of K-3 refractory with waste glass compositions developed for use in the WTP melters. The data will be used in the enhanced property/composition models being developed for waste glass vitrification and melter operations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W