At least 91 records · Page 5

Recent Developments in the Analysis of Couple Oscillator Arrays

This presentation considers linear arrays of coupled oscillators. Our purpose in coupling oscillators together is to achieve high radiated power through the spatial power combining which results when the oscillators are injection locked to each other. York, et. al. have shown that, left to themselves, the ensemble of injection locked oscillators oscillate at the average of the tuning frequencies of all the oscillators. Coupling these arrays achieves high radiated power through coherent spatial power combining. The coupled oscillators are usually designed to produce constant aperture phase. Oscillators are injection locked to each other or to a master oscillator to produce coherent radiation. Oscillators do not necessarily oscillate at their tuning frequency.

Pogorzelski, Ronald J.↗

A 311-GHz Fundamental Oscillator Using InP HBT Technology

This oscillator uses a single-emitter 0.3- m InP heterojunction bipolar transistor (HBT) device with maximum frequency of oscillation (fmax) greater than 500 GHz. Due to high conductor and substrate losses at submillimeterwave frequencies, a primary challenge is to efficiently use the intrinsic device gain. This was done by using a suitable transmission-line media and circuit topology. The passive components of the oscillator are realized in a twometal process with benzocyclobutene (BCB) used as the primary transmission line dielectric. The circuit was designed using microstrip transmission lines. The oscillator is implemented in a common-base topology due to its inherent instability, and the design includes an on-chip resonator, outputmatching circuitry, and an injection-locking port, the port being used to demonstrate the injection-locking prin ciple. A free-running frequency of 311.6 GHz has been measured by down-converting the signal. Ad di tionally, injection locking has been successfully demonstrated with up to 17.8 dB of injection-locking gain. The injection-locking reference signal is generated using a 2 20 GHz frequency synthesizer, followed by a doubler, active tripler, a W-band amplifier, and then a passive tripler. Therefore, the source frequency is multiplied 18 times to obtain a signal above 300 GHz that can be used to injection lock the oscillator. Measurement shows that injection locking has improved the phase noise of the oscillator and can be also used for synchronizing a series of oscillators. A signal conductor is implemented near the BCP -InP interface and the topside of the BCB layer is fully metallized as a signal ground. Because the fields are primarily constrained in the lower permittivity BCB region, this type of transmission line is referred to as an inverted microstrip. In addition, both common-emitter and commonbase circuits were investigated to determine optimum topology for oscillator design. The common -base topology required smaller amount of feedback than the common-emitter design, therefore preserving device gain, and was chosen for the oscillator design. The submillimeter-wave region offers several advantages for sensors and communication systems, such as high resolution and all-weather imaging due to the short-wavelength, and improved communication speeds by access to greater frequency bandwidth. This oscillator circuit is a prototype of the first HBT oscillator operating above 300 GHz. Additional development is necessary to increase the output power of the circuit for radar and imaging applications.

Gaier, Todd↗

Early Oscillation Detection Technique for Hybrid DC/DC Converters

Oscillation or instability is a situation that must be avoided for reliable hybrid DC/DC converters. A real-time electronics measurement technique was developed to detect catastrophic oscillations at early stages for hybrid DC/DC converters. It is capable of identifying low-level oscillation and determining the degree of the oscillation at a unique frequency for every individual model of the converters without disturbing their normal operations. This technique is specially developed for space-used hybrid DC/DC converters, but it is also suitable for most of commercial and military switching-mode power supplies. This is a weak-electronic-signal detection technique to detect hybrid DC/DC converter oscillation presented as a specific noise signal at power input pins. It is based on principles of feedback control loop oscillation and RF signal modulations, and is realized by using signal power spectral analysis. On the power spectrum, a channel power amplitude at characteristic frequency (CPcf) and a channel power amplitude at switching frequency (CPsw) are chosen as oscillation level indicators. If the converter is stable, the CPcf is a very small pulse and the CPsw is a larger, clear, single pulse. At early stage of oscillation, the CPcf increases to a certain level and the CPsw shows a small pair of sideband pulses around it. If the converter oscillates, the CPcf reaches to a higher level and the CPsw shows more high-level sideband pulses. A comprehensive stability index (CSI) is adopted as a quantitative measure to accurately assign a degree of stability to a specific DC/DC converter. The CSI is a ratio of normal and abnormal power spectral density, and can be calculated using specified and measured CPcf and CPsw data. The novel and unique feature of this technique is the use of power channel amplitudes at characteristic frequency and switching frequency to evaluate stability and identify oscillations at an early stage without interfering with a DC/DC converter s normal operation. This technique eliminates the probing problem of a gain/phase margin method by connecting the power input to a spectral analyzer. Therefore, it is able to evaluate stability for all kinds of hybrid DC/DC converters with or without remote sense pins, and is suitable for real-time and in-circuit testing. This frequency-domain technique is more sensitive to detect oscillation at early stage than the time-domain method using an oscilloscope.

Wang, Bright L.↗

Nature's Autonomous Oscillators

Nonlinearity is required to produce autonomous oscillations without external time dependent source, and an example is the pendulum clock. The escapement mechanism of the clock imparts an impulse for each swing direction, which keeps the pendulum oscillating at the resonance frequency. Among nature's observed autonomous oscillators, examples are the quasi-biennial oscillation and bimonthly oscillation of the Earth atmosphere, and the 22-year solar oscillation. The oscillations have been simulated in numerical models without external time dependent source, and in Section 2 we summarize the results. Specifically, we shall discuss the nonlinearities that are involved in generating the oscillations, and the processes that produce the periodicities. In biology, insects have flight muscles, which function autonomously with wing frequencies that far exceed the animals' neural capacity; Stretch-activation of muscle contraction is the mechanism that produces the high frequency oscillation of insect flight, discussed in Section 3. The same mechanism is also invoked to explain the functioning of the cardiac muscle. In Section 4, we present a tutorial review of the cardio-vascular system, heart anatomy, and muscle cell physiology, leading up to Starling's Law of the Heart, which supports our notion that the human heart is also a nonlinear oscillator. In Section 5, we offer a broad perspective of the tenuous links between the fluid dynamical oscillators and the human heart physiology.

Mayr, H. G.↗

A Study of the Free Oscillations of the Earth

Published observations on the toroidal oscillations of the earth are critically reviewed. A supplementary analysis of the record obtained by the Lamont strain seismometer is presented. Eleven toroidal modes are identified, and it is concluded that the periods are known to within 1 per cent. A perturbation scheme involving the ratio of the angular velocity of the earth to the resonant frequency is used in calculating the effects due to the rotation of the earth on the resonant frequency. The free oscillations are viewed as a superposition of traveling waves. In a nonrotating system two traveling waves combine to produce a stationary standing wave. In a rotating system, the rotation distinguishes between waves that travel in the direction of rotation and those that travel in the opposite direction. Rotation removes a degeneracy and results in a splitting of a spectral peak of order l into 2 times l plus 1 peaks. The fractional displacement in frequency for the lowest-order toroidal oscillations is 1/206 and of the same order as the Q of the peak, so that splitting will probably not be observed in the toroidal oscillations. Viewed locally, rotation causes a particle to precess about a direction parallel to the axis of rotation. This precession will cause a variation of amplitude with time if the motion is recorded by an instrument with an anisotropic response function. Care is therefore needed in studying the time decay of a given spectral peak. Rotation also couples the normal coordinates so that a motion that is initially purely horizontal will develop a vertical component. It is expected that vertical seismometers should record particle motion with the toroidal frequencies. The perturbations of the toroidal oscillations due to core-mantle interaction are treated in detail. An exact expression is obtained for the rate of energy dissipated by a finitely conducting plate oscillating across a magnetic field. The energy dissipated at the core-mantle boundary due to viscous and hydromagnetic coupling is shown to be insignificant as compared with the energy dissipated within the mantle. The toroidal magnetic field leaking into the lower mantle combines with the dipole field, resulting in a stress on the mantle, tending to stiffen the lower boundary. The stress is of sufficient magnitude to produce a displacement toward higher frequency in the lower-order toroidal oscillations. Observations on the (sub 0) T (sub 2) oscillations lead to an estimate of the toroidal magnetic field in the lower mantle. A calculation of elastic energy in the low-order oscillations suggests a value of 10 (sup 18) ergs per cycles per hour for the energy density at low frequencies in the Chilean earthquake. Each mode of oscillation has a characteristic radial distribution of elastic energy associated with it. This distribution determines which parts of the earth contribute most heavily in determining a particular resonant frequency. The distribution of energy for the lower 17 modes for a homogeneous and a Gutenberg model earth is calculated. The resonant frequencies for models of the earth based on the Gutenberg and Lehmann distribution of elastic properties are presented. It is shown that the Gutenberg model earth fits the observations more closely than the Lehmann model and that a slight alteration of the Gutenberg model gives a significantly better fit to the observations. The alteration involves a lower shear-wave velocity in the lower mantle while the Gutenberg velocity distribution is maintained in the upper mantle. Various studies of the earth's oscillations coupled with surface-wave investigations substantiate Gutenberg's hypothesis of a layer of low velocity in the upper mantle. The physical conditions required for the formation of a region of low velocity are examined in detail. The results confirm Birch's earlier statement that a temperature gradient in excess of 6 degrees to 7 degrees per kilometer is needed to produce a decrease in velocity. The low-velocity layer does not require that the temperature approach or exceed the melting temperature. If tile upper mantle is homogeneous, the region of lower velocity should commence at the base of the crust and extend to 150 kilometers under the oceans and about 100 kilometers under continental regions. The distribution of thermal conductivity and radioactivity consistent with the low-velocity layer is also considered.

MacDonald, Gordon J. F.↗

Validation of a Manually Oscillating Chair for In-The-Field Assessment of Dynamic Visual Acuity on Crewmembers Within Hours of Returning From Long-Duration Spaceflight

Long-duration spaceflight results in sensorimotor adaptations, which cause functional deficits during gravitational transitions, such as landing on a planetary surface after long-duration microgravity exposure. Both the vestibular system and the central nervous system are affected by gravitational transitions. These systems are responsible for coordinating head and eye movements via the vestibulo-ocular reflex (VOR) and go through an adaptation period upon exposure to microgravity. Consequently, they must also re-adapt to Earth's gravitational environment upon landing. This re-adaptation causes decrements in gaze control and dynamic visual acuity, with crewmembers reporting oscillopsia and blurred vision caused by retinal slip, or the inability to keep an image focused on their retina. This is thought to drive motion sickness symptoms experienced by most crewmembers following landing. Retinal slip can be estimated by dynamic visual acuity (DVA); visual acuity while in motion. Previously, DVA has been assessed in the laboratory where subjects walked at 6.4 km/hr on a motorized treadmill. Using this method, Peters et al. (2011) found that DVA is worsened in astronauts by an average of 0.75 eye-chart lines one day after landing. However, it is believed that re-adaptation occurs quickly and that DVA might be worse immediately upon re-exposure to a gravitational environment. Since many crewmembers are unable to walk safely upon landing, it was necessary to develop a method for replicating the vertical head movements associated with walking. In addition, the use of a chair to imitate the head displacement caused by walking isolates eye-head interactions without allowing for trunk and lower-body compensation, as seen with treadmill walking (Mulavara & Bloomberg 2003). Therefore, a modality for assessing DVA in the field within a few hours of landing was developed. In this study, we validated the ability of a manually operated oscillating chair to reproduce the oscillatory frequency of walking on a treadmill. Healthy non-astronaut subjects (n=14) participated in one test session and completed three static (seated) and three dynamic (walking/oscillated) visual acuity tests. DVA was assessed using a motorized treadmill, an automated oscillating chair, and a manually operated chair, both developed in the Neuroscience Laboratory at JSC. The automated chair was motor-driven and set to oscillate vertically at 2 Hz with a vertical displacement of +/- 5 cm to simulate vertical translation while walking. The manually operated chair was oscillated vertically by a test operator to the beat of a metronome at 120 beats/min (2 Hz) and a vertical displacement of approximately +/- 5 cm. As the subject was oscillated, they were asked to discern the direction gap of Landolt-C optotypes of varying sizes and verbally reported the direction while an operator recorded their response using a gamepad. Subjects were outfitted with accelerometers (sampling rate = 128 Hz) on their head, trunk and lumbar spine. A fast Fourier transform was performed on the vertical trunk acceleration to compare the peak and spread of the distribution of oscillation frequencies for each oscillating condition. The spread of the frequency distribution for the manual chair was not significantly different from either the treadmill or the automated chair. However, all three conditions had similar non-zero standard error values, suggesting a variance in head movement frequency which may affect DVA. The average oscillation frequency of the manual chair (1.85 Hz) was significantly different (α=0.05) from that of treadmill walking (2.24 Hz), but not significantly different from that of the automated chair (1.85 Hz) and all three conditions had small standard errors (SEM = 0.04, 0.06, and 0.08 Hz for manual, treadmill, and automated respectively). This implies that both chairs oscillate at a frequency below that of treadmill walking, but are comparable to each other and reproducible across sessions. Additionally, DVA scores did not vary significantly across conditions. The smaller spread values of the oscillating chairs' frequencies indicated mitigation of variation induced by locomotor strategies, which enables better examination of the issue of VOR adaptation. Furthermore, due to the deconditioned state of crewmembers in the initial hours after landing, it is easier to transport a manual bouncing chair into the field and safer to perform a vision test while seated in a chair versus walking on a treadmill. Therefore, the manually oscillating chair has been deemed to meet and exceed the DVA testing capabilities previously obtained by treadmill walking.

Kreutzberg, G. A.↗

A Comprehensive Method to Mitigate Forced Oscillations in Large Interconnected Power Grids

Multiple severe forced oscillation events have recently been observed across the North American interconnections and around the world. These forced oscillations have caused power swings, limited power transfer capability, damaged equipment, and persisted indefinitely until the driving source was located and removed. This paper proposes a comprehensive method to mitigate forced oscillations. Once a forced oscillation is detected, a new source location algorithm can be used to locate the source based on the oscillation mode angle without requiring system topology information. If the source cannot be quickly located and removed, a control strategy can be activated to modulate the active power of utility-scale inverterbased battery energy storage systems (BESSs) to reduce the energy of forced oscillations to a safe level and allow sufficient time for locating the exact source. The proposed source location algorithm is validated using measurements collected during the January 11, 2019 forced oscillation event in North America and other actual grid events, while the proposed control strategy is verified using the Eastern Interconnection dynamic model under the replicated January 11, 2019 forced oscillation event. The simulation results demonstrated that the proposed source location algorithm can accurately identify the forced oscillation source, and the proposed control strategy can significantly reduce forced oscillation energy.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Neurodynamic oscillators

Oscillation of electrical activity has been found in many nervous systems, from invertebrates to vertebrates including man. There exists experimental evidence of very simple circuits with the capability of oscillation. Neurons with intrinsic oscillation have been found and also neural circuits where oscillation is a property of the network. These two types of oscillations coexist in many instances. It is nowadays hypothesized that behind synchronization and oscillation there is a system of coupled oscillators responsible for activities that range from locomotion and feature binding in vision to control of sleep and circadian rhythms. The huge knowledge that has been acquired on oscillators from the times of Lord Rayleigh has made the simulation of neural oscillators a very active endeavor. This has been enhanced with more recent physiological findings about small neural circuits by means of intracellular and extracellular recordings as well as imaging methods. The future of this interdisciplinary field looks very promising; some researchers are going into quantum mechanics with the idea of trying to provide a quantum description of the brain. In this work we describe some simulations using neuron models by means of which we form simple neural networks that have the capability of oscillation. We analyze the oscillatory activity with root locus method, cross-correlation histograms, and phase planes. In the more complicated neural network models there is the possibility of chaotic oscillatory activity and we study that by means of Lyapunov exponents. The companion paper shows an example of that kind.

Espinosa, Ismael↗

Irregular, long-period boundary oscillations beyond approximately 100 R(sub e): GEOTAIL plasma observations

Near the tail boundary beyond about 100 Re, GEOTAIL often measures irregular, long-period oscillations in plasma velocity and density. Flow speed and density oscillate between magnetosheath values and values an order of magnitude less. The oscillations can persist for days. A typical oscillation lasts 100 minutes, but the range is large. The oscillations are highly asymmetric in that the increasing phase of the oscillation is an order of magnitude faster than the decreasing phase. This asymmetry shows that they are a distinct class of oscillations, not previously explicitly reported, and that they are not mere consequences of tail flapping in a variable solar wind. The changes in flow direction through an oscillation imply that the oscillation results from a motion of the boundary toward and away from the spacecraft with an amplitude between 5 and 10 R(sub e). A consideration of options suggests that the most plausible cause of these oscillations is the 'breathing' of the magnetotail that attends the substorm cycle.

Siscoe, G. L.↗

Recovery of 29 Second Oscillations in Hubble Space Telescope Eclipse Observations of the Cataclysmic Variable UX Ursae Majoris

Low-amplitude (approximately 0.5%) 29 s oscillations have been detected in Hubble Space Telescope Faint Object Spectrograph eclipse observations of the nova-like cataclysmic variable UX UMa. These are the same dwarf nova-type oscillations that were originally discovered in this system in 1972. The 29 s oscillations are seen in one pair of eclipse sequences obtained with the FOS/PRISM in 1994 November but not in a similar pair obtained with the FOS/GI60L grating in August of the same year. The oscillations in the PRISM data are sinusoidal to within the small observational errors and undergo an approximately - 360' phase shift during eclipses (i.e., one cycle is lost). The amplitudes are highest at pre-eclipse orbital phases and exhibit a rather gradual eclipse whose shape is roughly similar to, although perhaps slightly narrower than, LTX UMa's overall light curve in the PRISM bandpass (2000-8000 A). Spectra of the oscillations have been constructed from pre-, mid, and post-eclipse data segments of the November observations. The spectra obtained from the out-of-eclipse segments are extremely blue, and only lower limits can be placed on the temperature of the source that dominates the modulated flux at these orbital phases. Lower limits derived from blackbody (stellar atmosphere) model fits to these data are >or equal to 95,000 K (> or equal to 85,000 K); the corresponding upper limits on the projected area of this source are all less than 2% of the white dwarf (WD) surface area. By contrast, oscillation spectra derived from mid- eclipse data segments are much redder. Fits to these spectra yield temperature estimates in the range 20,000 K approximately greater T and T approximately less than 30,000 K for both blackbody and stellar atmosphere models and corresponding projected areas of a few percent of the WD surface area. These estimates are subject to revision if the modulated emission is optically thin. We suggest that the ultimate source of the oscillations is a hot, compact region near disk center, but that a significant fraction of the observed, modulated flux is due to reprocessing of the light emitted by this source in the accretion disk atmosphere. The compact source is occulted at orbital phases near mid-eclipse, leaving only part of the more extended reprocessing region(s) to produce the weak oscillations that persist even at conjunction. The highly sinusoidal oscillation pulse shape does not permit the identification of the compact comonent in this model with emission produced by a rotating disturbance in the inner disk or in a classical, equatorial boundary layer. Instead, this component could arise in a bright spot on the surface of the WD, possibly associated with a magnetic pole. However, a standard intermediate polar model can also be ruled out since UX UMa's oscillation period has been seen to change on timescales much shorter than the minimum timescale required to spin up the WD by accretion torques. A model invoking magnetically controlled accretion onto differentially rotating WD surface layers may be viable, but needs more theoretical work.

Knigge, Christian↗

Multichannel X-Band Dielectric-Resonator Oscillator

A multichannel dielectric-resonator oscillator (DRO), built as a prototype of a local oscillator for an X-band transmitter or receiver, is capable of being electrically tuned among and within 26 adjacent frequency channels, each 1.16 MHz wide, in a band ranging from 7,040 to 7,070 GHz. The tunability of this oscillator is what sets it apart from other DROs, making it possible to use mass-produced oscillator units of identical design in diverse X-band applications in which there are requirements to use different fixed frequencies or to switch among frequency channels. The oscillator (see figure) includes a custom-designed voltage-controlled-oscillator (VCO) monolithic microwave integrated circuit (MMIC), a dielectric resonator disk (puck), and two varactor-coupling circuits, all laid out on a 25-mil (0.635-mm)-thick alumina substrate having a length and width of 17.8 mm. The resonator disk has a diameter of 8.89 mm and a thickness of 4.01 mm. The oscillator is mounted in an 8.9-mm-deep cavity in a metal housing. The VCO MMIC incorporates a negative- resistance oscillator amplifier along with a buffer amplifier. The resonator disk is coupled to a microstrip transmission line connected to the negative-resistance port of the VCO MMIC. The two varactor-coupling circuits include microstrip lines, laid out orthogonally to each other, for coupling with the resonator disk. Each varactor microstrip line is DC-coupled to an external port via a microwave choke. One varactor is used for coarse tuning to select a channel; the other varactor is used (1) for fine tuning across the 1.16-MHz width of each channel and (2) as a feedback port for a phase-lock loop. The resonator disk is positioned to obtain (1) the most desirable bandwidth, (2) relatively tight coupling with the microstrip connected to the coarse-tuning varactor, and (3) relatively loose coupling with the microstrip connected to the fine-tuning varactor. Measurements of performance showed that the oscillator can be switched among any of the 26 channels and can be phase-locked to a nominal frequency in any channel. The degree of nonlinearity of tuning was found not to exceed 2.5 percent. The tuning sensitivity was found to be 6.15 MHz/V at a bias offset of -2 V on the phase-lock-loop varactor. The phase noise of the oscillator in free-running operation was found to be -107 dBc/Hz (where dBc signifies decibels relative to the carrier signal) at 100 kHz away from the carrier frequency.

Mysoor, Narayan↗

120-GHz HEMT Oscillator With Surface-Wave-Assisted Antenna

Two monolithic microwave integrated circuits (MMICs) have been designed and built to function together as a source of electromagnetic radiation at a frequency of 120 GHz. One of the MMICs is an oscillator and is the highest-power 120-GHz oscillator reported thus far in the literature. The other MMIC is an end-fire antenna that radiates the oscillator signal. Although these MMICs were constructed as separate units and electrically connected with wire bonds, future oscillator/ antenna combinations could readily be fabricated as monolithic integrated units. Such units could be used as relatively high-power solid-state microwave sources in diverse applications that include automotive radar, imaging, scientific instrumentation, communications, and radio astronomy. As such, these units would be attractive alternatives to vacuum-tube oscillators, which are still used to obtain acceptably high power in the frequency range of interest. The oscillator (see figure) includes a high-electron-mobility transistor (HEMT), with gate-periphery dimensions of 4 by 37 m, in a common-source configuration. The series feedback element of the oscillator is a grounded coplanar waveguide (CPW) at the source. The HEMT is biased for class-A operation (meaning that current is conducted throughout the oscillation cycle) to maximize the output power of the oscillator. Input and output impedance-matching circuit elements are designed to maximize output power and to establish the conditions needed for oscillation. The design of the antenna takes advantage of surface waves, which, heretofore, have been regarded as highly disadvantageous because they can leak power and degrade the performances of antennas that have not been designed to exploit them. Measures taken to suppress surface waves have included complex machining of circuit substrates and addition of separate substrates. These measures are difficult to implement in standard MMIC fabrication processes. In contrast, because the design of the present antenna eliminates the need to suppress surface waves, the fabrication of the antenna is fully compatible with standard MMIC fabrication processes.

Samoska, Lorene↗

A comprehensive review of nonlinear oscillators in hydrokinetic energy harnessing using flow-induced vibrations

A comprehensive review of hydrokinetic energy converters based on alternating lift technology (ALT) is provided. Emphasis is on nonlinear oscillators based on Flow Induced Vibration (FIV) or Oscillation (FIO). Due to strong coupling in Fluid-Structure Interaction (FSI), and in order to maximize the hydrokinetic harnessed energy, design of nonlinear oscillators and analysis by model tests or computational fluid dynamics dominates this area. Research confirmed that the nonlinear oscillator can harvest energy from a stochastic excitation modeled by a generic wide spectrum, and overcome the most severe oscillator limitations: specifically, the need for continuous frequency tuning due to the narrow bandwidth response, and low efficiency outside the narrow bandwidth oscillator response. This review covers the following aspects of nonlinear oscillators in ALT converters: (1) Geometric changes in oscillator cross-section; e.g., circular, square, rectangular, or trilateral shapes. (2) Passive turbulence control of FIV/FIO. (3) Position based nonlinear stiffness. (4) Multi-cylinder synergistic FIV/FIO. (5) Mechanically linked oscillators. (6) Velocity-based, nonlinear, adaptive harnessing damping.

42 ENGINEERING↗

Rapid CO2 changes cause oscillations in photosynthesis that implicate PSI acceptor-side limitations

Abstract Oscillations in CO2 assimilation rate and associated fluorescence parameters have been observed alongside the triose phosphate utilization (TPU) limitation of photosynthesis for nearly 50 years. However, the mechanics of these oscillations are poorly understood. Here we utilize the recently developed dynamic assimilation techniques (DATs) for measuring the rate of CO2 assimilation to increase our understanding of what physiological condition is required to cause oscillations. We found that TPU-limiting conditions alone were insufficient, and that plants must enter TPU limitation quickly to cause oscillations. We found that ramps of CO2 caused oscillations proportional in strength to the speed of the ramp, and that ramps induce oscillations with worse outcomes than oscillations induced by step change of CO2 concentration. An initial overshoot is caused by a temporary excess of available phosphate. During the overshoot, the plant outperforms steady-state TPU and ribulose 1,5-bisphosphate regeneration limitations of photosynthesis, but cannot exceed the rubisco limitation. We performed additional optical measurements which support the role of PSI reduction and oscillations in availability of NADP+ and ATP in supporting oscillations.

59 BASIC BIOLOGICAL SCIENCES↗

A Twin Circuit Theory-Based Framework for Oscillation Event Analysis in Inverter-Dominated Power Systems With Case Study for Kaua‘i System

Here, this paper proposes a real-world oscillation event analysis framework for power systems that include inverter-based resources together with synchronous generators. Specifically, the proposed framework combines both measurement-and model-based techniques to readily identify potential oscillation sources, replay the oscillation event with numerical simulation, unveil the underlying oscillation mechanism, and suggest mitigation methods for a wide range of oscillation events. To strengthen the theoretical foundation of our analysis framework, this paper proposes a twin circuit theory that provides theoretical support for one key utilized but not well-proven measurement-based oscillation source identification method-Dissipating Energy Flow. Our twin circuit theory also shows that adopting well-tuned grid-forming inverters can be a potential mitigation method for oscillation events. Finally, the effectiveness of our proposed oscillation event analysis framework is demonstrated by addressing a real-world 18-20 Hz oscillation event in Kaua‘i's power system on November 21, 2021.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impact of the Exciter and Governor Parameters on Forced Oscillations

In recent years, the frequency of forced oscillation events due to control system malfunctions or improper parameter settings has increased. Tuning the parameters of exciters and governor models is crucial for maintaining power system stability. Traditional simulation studies typically involve small transient disturbances or step changes to find optimal parameter sets, but existing optimization algorithms often fall short in fine-tuning for forced oscillations. Identifying the sensitive parameters within these control models is essential for ensuring stability during large, sustained disturbances. This study focuses on identifying these critical exciter and governor model parameters by analyzing their influence on sustained forced oscillations. Using Kundur’s two-area system, we analyze common exciter models such as SCRX, ESST1A, and AC7B, along with governor models like GAST, HYGOV, and GGOV1, utilizing PSS®E software version 34. Sustained forced oscillations are injected at generator-1 of area-1, with individual parameter changes dynamically simulated. By considering a local oscillation frequency of 1.4 Hz and an inter-area oscillation mode of 0.25 Hz, we analyze the impact of each parameter change on the magnitude and frequency of forced oscillations as well as on active and reactive power outputs. This novel approach highlights the most influential parameters of each tested model—such as exciter, governor, and turbine gains, as well as time constant parameters—on the impact of forced oscillations. Based on our findings, the sensitive parameters of each tested model are ranked. These would provide valuable insights for industry operators to fine-tune control settings during oscillation events, ultimately enhancing system stability.

42 ENGINEERING↗

Tuning of oscillation modes by controlling dimensionality of spin structures

Abstract Harmonic oscillation of spin structures is a physical phenomenon that offers great potential for applications in nanotechnologies such as nano-oscillators and bio-inspired computing. The effective tuning of oscillations over wide frequency ranges within a single ferromagnetic nanoelement is a prerequisite to realize oscillation-based nanodevices, but it has not been addressed experimentally or theoretically. Here, utilizing a vortex core structure, one of spin structures, we report a drastic change of oscillation modes over the frequency range from MHz to sub-GHz in a 100 nm-thick permalloy circular disk. Oscillation mode was found to considerably depend on the shape and dimension of the vortex core structure and various oscillation modes over a wide range of frequencies appeared with dimensional change in the vortex core structure. This work demonstrates that oscillation modes of the vortex core structure can be effectively tuned and opens a way to apply spin structures to oscillation-based technology.

36 MATERIALS SCIENCE↗

Injection locking and coupling dynamics in superconducting nanowire-based cryogenic oscillators

Oscillators designed to function at cryogenic temperatures play a critical role in superconducting electronics and quantum computing by providing stable, low-noise signals with minimal energy loss. Here, in this work, we present a comprehensive numerical study of injection locking and mutual coupling dynamics in superconducting nanowire (ScNW)-based cryogenic oscillators. Using the design space of a standalone ScNW-based oscillator, we investigate two critical mechanisms that govern frequency synchronization and signal coordination in cryogenic computing architectures: (1) injection locking induced by an external AC signal with a frequency near the oscillator's natural frequency, and (2) the mutual coupling dynamics between two ScNW oscillators under varying coupling strengths. We identify key design parameters—such as shunt resistance, nanowire inductance, and coupling strength—that govern the locking range. Additionally, we examine how the amplitude of the injected signal affects the amplitude of the locked oscillation, offering valuable insights for power-aware oscillator synchronization. Furthermore, we analyze mutual synchronization between coupled ScNW oscillators using capacitive and resistive coupling elements. Our results reveal that the phase difference between oscillators can be controlled by tuning the coupling strength, enabling programmable phase-encoded information processing. These findings could enable building ScNW-based oscillatory neural networks, synchronized cryogenic logic blocks, and on-chip cryogenic resonator arrays.

Artificial neural networks↗