Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optical design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

The WFIRST Coronagraph Instrument Optical Design Update

The WFIRST Coronagraph Instrument will perform direct imaging of exoplanets via coronagraphy of the host star. It uses both the Hybrid Lyot and Shaped Pupil Coronagraphs to meet the mission requirements. The Phase A optical design fits within the allocated instrument enclosure and accommodates both coronagraphic techniques. It also meets the challenging wavefront error requirements. We present the optical performance including throughput of the imaging and IFS channels, as well as the wavefront errors at the first pupil and the imaging channel. We also present polarization effects from optical coatings and analysis of their impacts on the performance of the Hybrid Lyot coronagraph. We report the results of stray light analysis of our Occulting Mask Coronagraph testbed.

Zhao, Feng↗

The WFIRST/AFTA coronagraph instrument optical design

The most recent concept for the Wide Field Infrared Survey Telescope (WFIRST) Design Reference Mission (DRM) features an instrument that will perform exoplanet detection via coronagraphy of the host star. This observatory is based on the existing Astrophysics Focused Telescope Asset’s (AFTA) 2.4-meter telescope. The WFIRST/AFTA Coronagraph Instrument combines the Hybrid Lyot and Shaped Pupil Coronagraphs to meet the science requirements. The cycle 5 optical design fits the required enclosure and accommodates both coronagraphic architectures. We present the optical performance including throughput of both the imaging and the IFS channels, the wavefront error at the first pupil,and polarization effects from optical coatings.

Zhao, Feng↗

Optics Design for the U.S. SKA Technology Development Project Design Verification Antenna

The U.S. design concept for the Square Kilometer Array (SKA) program is based on utilizing a large number of 15 meter dish antennas. The Technology Development Project (TDP) is planning to design and build the first of these antennas to provide a demonstration of the technology and a solid base on which to estimate costs. This paper describes the performance of the selected optics design. It is a dual-shaped offset Gregorian design with a feed indexer that can accommodate corrugated horns, wide band single pixel feeds or phased array feeds.

Corrugated Horns↗

The Cosmology Large Angular Scale Surveyor (CLASS): 40 GHz Optical Design

The Cosmology Large Angular Scale Surveyor (CLASS) instrument will measure the polarization of the cosmic microwave background at 40, 90, and 150 GHz from Cerro Toco in the Atacama desert of northern Chile. In this paper, we describe the optical design of the 40 GHz telescope system. The telescope is a diffraction limited catadioptric design consisting of a front-end Variable-delay Polarization Modulator (VPM), two ambient temperature mirrors, two cryogenic dielectric lenses, thermal blocking filters, and an array of 36 smooth-wall scalar feedhorn antennas. The feed horns guide the signal to antenna-coupled transition-edge sensor (TES) bolometers. Polarization diplexing and bandpass definition are handled on the same microchip as the TES. The feed horn beams are truncated with 10 dB edge taper by a 4 K Lyot-stop to limit detector loading from stray light and control the edge illumination of the front-end VPM. The field-of-view is 19 deg x 14 deg with a resolution for each beam on the sky of 1.5 deg. FWHM.

Eimer, Joseph R.↗

Optical Design of the MOSES Sounding Rocket Experiment

The Multi-Order Solar EUV Spectrograph (MOSES) is a sounding rocket payload now being developed by Montana State University in collaboration with the Goddard Space Flight Center, Lockheed Martin Advanced Technology Center, and Mullard Space Science Laboratory. The instrument utilizes a unique optical design to provide solar EUV measurements with true 2-pixel resolutions of 1.0 arcsec and 60 mA over a full two-dimensional field of view of 1056 x 528 arcsec, all at a time cadence of 10 s. This unprecedented capability is achieved by means of an objective spherical grating 100 mm in diameter, ruled at 833 gr/mm. The concave grating focuses spectrally dispersed solar radiation onto three separate detectors, simultaneously recording the zero-order as well as the plus and minus first-spectral-order images. Data analysis procedures, similar to those used in X-ray tomography reconstructions, can then disentangle the mixed spatial and spectral information recorded by the multiple detectors. A flat folding mirror permits an imaging focal length of 4.74 m to be packaged within the payload's physical length of 2.82 m. Both the objective grating and folding flat have specialized, closely matched, multilayer coatings that strongly enhance their EUV reflectance while also suppressing off-band radiation that would otherwise complicate data inversion. Although the spectral bandpass is rather narrow, several candidate wavelength intervals are available to carry out truly unique scientific studies of the outer solar atmosphere. Initial flights of MOSES, scheduled to begin in 2004, will observe a 10 Angstrom band that covers very strong emission lines characteristic of both the sun's corona (Si XI 303 Angstroms) and transition-region (He II 304 Angstroms). The MOSES program is supported by a grant from NASA's Office of Space Science.

Thomas, Roger J.↗

Optical Design for the Submillimeter and Far InfraRed Experiment (SAFIRE)

The SAFIRE, the Submillimeter and Far InfraRed Experiment, was designed for interstellar physics in the airborne Observatory SOFIA. SAFIRE is a cryogenic Echelle Grating spectrograph for covering 27 to 470 microns; with R ranging from 2-6,000. Here we will discuss the details of the optical design, the design process, and the performance of the instrument

Pasquale, Bert A.↗

Optical Design for the Composite InfraRed Spectrometer Lite (CIRS-Lite)

Following up on Cassini/CIRS, we are building the next-generation Composite InfraRed Spectrometer for deep-space planetary exploration. CIRS-Lite combines Mid & Far-IR channels into a single instrument with 4x the spectral sensitivity of CIRS. Here we discuss the instrument optical design, the design process, and the system performance.

Pasquale, Bert A.↗

Optical Design of the Developmental Cryogenic Active Telescope Testbed (DCATT)

In the summer of 1996, three Study teams developed conceptual designs and mission architectures for the Next Generation Space Telescope (NGST). Each group highlighted areas of technology development that need to be further advanced to meet the goals of the NGST mission. The most important areas for future study included: deployable structures, lightweight optics, cryogenic optics and mechanisms, passive cooling, and on-orbit closed loop wavefront sensing and control. NASA and industry are currently planning to develop a series of ground testbeds and validation flights to demonstrate many of these technologies. The Deployed Cryogenic Active Telescope Testbed (DCATT) is a system level testbed to be developed at Goddard Space Flight Center in three phases over an extended period of time. This testbed will combine an actively controlled telescope with the hardware and software elements of a closed loop wavefront sensing and control system to achieve diffraction limited imaging at 2 microns. We will present an overview of the system level requirements, a discussion of the optical design, and results of performance analyses for the Phase 1 ambient concept for DCATT,

Davila, Pam↗

Optical design of the Mapping Imaging Spectrometer for Europa (MISE)

e Mapping Imaging Spectrometer for Europa (MISE) is a high-throughput pushbroom imaging spectrometer designed for NASA’s planned flyby mission to Jupiter’s moon Europa. The MISE design utilizes heritage from previously demonstrated instruments on airborne platforms, while advancing the state of the art to operate within Europa’s challenging environment. The instrument operates at F/1.4 and covers a spectral range from 0.8 to 5 microns with 10 nm spectral sampling. Through high resolution mapping, MISE is designed to identify distributions of organics, salts, acid hydrates, water ice phases, altered silicates, radiolytic compounds, and warm thermal anomalies at global, regional, and local scales. Such distribution maps will help study surface and subsurface geologic processes, and assess the habitability of Europa’s ocean. We discuss the optical specifications and baseline performance of the MISE optical design.

Van Gorp, Byron E.↗

Optical Designs for a Solar Orbiter EUV Imager

An EUV Imager is baselined as one of the remote sensing instruments onboard the Solar Orbiter mission now being planned by ESA. The performance goals for this instrument may be achieved by a specialized 'slitless spectrograph' design, which could offer EUV spectroscopic information as an added bonus. I will discuss my studies of such a design, tailored for the Solar Orbiter scientific objectives and scaled to the available payload envelope. Some of the trade-offs required in terms of sensitivity, field-of-view, and spatial resolution will be described, so that the science team can make optimized choices from the full range of possible optical-design solutions.

Thomas, Roger J.↗

RIMAS - Optical Design Development of the Imager/Spectrometer for the Discovery Channel Telescope

The Rapid IMAger - Spectrometer (RIMAS) is a collaborative effort between the University of Maryland at College Park, NASA-GSFC and Lowell Observatory designed for use on the 4.3 meter Discovery Channel Telescope at Lowell. The primary science goal of the instrument is the study of gamma-ray burst (ORB) afterglow appearing in the near-infrared. Continuous operation will allow measurements beginning minutes after the prompt emission. We present the results of the RIMAS optical design development. The instrument consists of two arms separated by a dichroic: the first for the Y and J bands (0.9 - 1.35 microns) and the second for the Hand K-bands (1.5 - 1.8 and 2.0 - 2.4 microns). Each arm will be equipped with two broad band filters for imaging, as well as low resolution and echelle grisms. The imaging modes are designed to be diffraction limited, with one pixel corresponding to approx.0.35 arcseconds, while the diffractive modes have resolving powers of approximately 20 and 4,000. With photometric and spectroscopic capabilities, RIMAS will be well positioned to quickly determine redshifts, followed by high resolution spectroscopic studies of ORB afterglow.

Capone, John↗

Beam optics design of a prototype 20 kW conduction-cooled SRF accelerator for medical sterilization

Superconducting technology has significantly advanced the capabilities of particle accelerators, facilitating higher beam-power operations for fundamental research at a comparatively lower cost. However, the conventional implementation of superconducting technology introduces complexities in the form of cryogenic plants, cryogenic distribution systems and substantial construction and operational cost. In response to these challenges, recent research efforts at Fermilab have been dedicated to the development of a cryogen-free, conduction-cooled Nb3Sn-based superconducting technology. This paper outlines the beam optics design of a 20-kW conduction-cooled compact superconducting accelerator for medical sterilization. The paper reviews both the physics and practical constraints associated with high beam-power operation within the context of industrial applications. The focus is on providing insights into the potential of this innovative technology to overcome existing challenges and pave the way for more accessible and efficient industrial particle accelerators.

Saini, A. [Fermilab]↗

Beam Optics Design of A Prototype 20 kW Conduction-Cooled SRF Accelerator for Medical Sterilization

Superconducting technology has significantly advanced the capabilities of particle accelerators, facilitating higher beam-power operations for fundamental research at a comparatively lower cost. However, the conventional implementation of superconducting technology introduces complexities in the form of cryogenic plants, cryogenic distribution systems and substantial construction and operational cost. In response to these challenges, recent research efforts at Fermilab have been dedicated to the development of a cryogen-free, conduction-cooled Nb3Sn-based superconducting technology. This paper outlines the beam optics design of a 20-kW conduction-cooled compact superconducting accelerator for medical sterilization. The paper reviews both the physics and practical constraints associated with high beam-power operation within the context of industrial applications. The focus is on providing insights into the potential of this innovative technology to overcome existing challenges and pave the way for more accessible and efficient industrial particle accelerators.

43 PARTICLE ACCELERATORS↗

Electro-Optical Design for Efficient Visual Communication

Visual communication, in the form of telephotography and television, for example, can be regarded as efficient only if the amount of information that it conveys about the scene to the observer approaches the maximum possible and the associated cost approaches the minimum possible. Elsewhere we have addressed the problem of assessing the end to end performance of visual communication systems in terms of their efficiency in this sense by integrating the critical limiting factors that constrain image gathering into classical communications theory. We use this approach to assess the electro-optical design of image gathering devices as a function of the f number and apodization of the objective lens and the aperture size and sampling geometry of the phot-detection mechanism. Results show that an image gathering device that is designed to optimize information capacity performs similarly to the human eye. For both, the performance approaches the maximum possible, in terms of the efficiency with which the acquired information can be transmitted as decorrelated data, and the fidelity, sharpness, and clearity with which fine detail can be restored.

Huck, Friedrich O.↗

Beam Optics Design of a Prototype 20 KW Conduction-cooled SRF Accelerator for Medical Sterilization

Superconducting technology has significantly advanced the capabilities of particle accelerators, facilitating higher beam-power operations for fundamental research at a comparatively lower cost. However, the conventional implementation of superconducting technology introduces complexities in the form of cryogenic plants, cryogenic distribution systems and substantial construction and operational cost. In response to these challenges, recent research efforts at Fermilab have been dedicated to the development of a cryogen-free, conduction-cooled Nb3Sn-based superconducting technology. This paper outlines the beam optics design of a 20-kW conduction-cooled compact superconducting accelerator for medical sterilization. The paper reviews both the physics and practical constraints associated with high beam-power operation within the context of industrial applications. The focus is on providing insights into the potential of this innovative technology to overcome existing challenges and pave the way for more accessible and efficient industrial particle accelerators.

43 PARTICLE ACCELERATORS↗

Optical design of the Ultraviolet Imaging Spectrograph for the Cassini mission to Saturn

When the Cassini spacecraft arrives at Saturn early in the next century it will carry an Ultraviolet Imaging Spectrograph (UVIS). Observations made with the UVIS will support a broad set of scientific investigations including spectroscopy, imaging, and occultations. The UVIS consists of three spectroscopic channels covering the wavelength ranges 55-115 nm, 115-190 nm, and 160-320 nm. Each channel has an off-axis parabolic telescope followed by a toroidal grating spectrograph and an imaging microchannel plate-CODACON detector. The UVIS configuration was selected as a balanced solution to a large number of engineering and scientific constraints. We describe these constraints, the optical design, and the anticipated performance of the instrument.

Mcclintock, William E.↗