Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “online”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

A consumer-centric approach to quantify efficiency of receiving goods purchased via online

Virtual participation in shopping activities has increased exponentially in the past four years compared to the last couple of decades. E-tailing or online shopping offers the convenience of goods reaching a consumer instead of a consumer traveling to a store, but it has downsides like geographical service variability and negative social externalities such as increased energy consumption and emissions. This study proposes a novel approach to quantify e-tailing efficiency from the consumers’ viewpoint. The methodology is innovative in its integration of accessibility theory with energy and cost impedance factors and consideration of delivering and picking up goods purchased via online. The methodology is implemented for the San Francisco Bay Area and is subject to scenarios that see enhancements to various facets of online shopping delivery. Results demonstrate that increasing the frequency of e-commerce deliveries helps improve e-tailing efficiency in rural locations, while improvements in energy and cost aspects of delivery modes are seen to improve e-tailing efficiencies in the central parts of the region. The approach proposed can provide valuable insights on where people have limited benefits from online shopping and how emerging delivery mechanisms can change the quality of the e-commerce experience within a city. This research offers a replicable framework for assessing e-commerce systems in diverse geographic contexts, contributing to the development of equitable and environmentally sustainable urban freight systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

XCMS Online: A Web-Based Platform to Process Untargeted Metabolomic Data

Recently, interest in untargeted metabolomics has become prevalent in the general scientific community among an increasing number of investigators. The majority of these investigators, however, do not have the bioinformatic expertise that has been required to process metabolomic data by using command-line driven software programs. Here we introduce a novel platform to process untargeted metabolomic data that uses an intuitive graphical interface and does not require installation or technical expertise. This platform, called XCMS Online, is a web-based version of the widely used XCMS software that allows users to easily upload and process liquid chromatography/mass spectrometry data with only a few mouse clicks. XCMS Online provides a solution for the complete untargeted metabolomic workflow including feature detection, retention time correction, alignment, annotation, statistical analysis, and data visualization. Results can be browsed online in an interactive, customizable table showing statistics, chromatograms, and putative METLIN identities for each metabolite. Additionally, all results and images can be downloaded as zip files for offline analysis and publication. XCMS Online is available at https://xcmsonline.scripps.edu.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An architecture for real time data acquisition and online signal processing for high throughput tandem mass spectrometry

Independent, greedy collection of data events using simple heuristics results in massive over-sampling of the prominent data features in large-scale studies over what should be achievable through “intelligent,” online acquisition of such data. As a result, data generated are more aptly described as a collection of a large number of small experiments rather than a true large-scale experiment. Nevertheless, achieving “intelligent,” online control requires tight interplay between state-of-the-art, data-intensive computing infrastructure developments and analytical algorithms. In this paper, we propose a Software Architecture for Mass spectrometry-based Proteomics coupled with Liquid chromatography Experiments (SAMPLE) to develop an “intelligent” online control and analysis system to significantly enhance the information content from each sensor (in this case, a mass spectrometer). Using online analysis of data events as they are collected and decision theory to optimize the collection of events during an experiment, we aim to maximize the information content generated during an experiment by the use of pre-existing knowledge to optimize the dynamic collection of events.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Robust Online Sequential RVFLNs for Data Modeling of Dynamic Time-Varying Systems with Application of an Ironmaking Blast Furnace

In a world where the increasing complexity of modern industrial processes brings difficulties for accurate mathematical modeling, taking advantage of data has become an efficient solution to complex dynamic process modeling issue. In this paper, we develop a novel robust online sequential version of random vector functional-link networks (RVFLNs) for data-driven modeling of dynamic time-varying system and applied it in a blast furnace (BF) ironmaking process. First, to overcome the time-varying dynamics of process and to enable the RVFLNs to learn online with avoiding data saturation, an improved online sequential version of RVFLNs (OS-RFVLNs) is first presented by online sequential learning with forgetting factor. This improved OS-RVFLNs algorithm is not only suitable for the real-time and large data transfer situation, but also can adjust the sensitivity of the algorithm to different samples with the help of the introduced forgetting factor. Second, since the output weights of the improved OS-RVFLNs as well as other RVFLNs algorithms are obtained by the least squares approach, a robustness problem may occur when the training dataset is contaminated with various outliers. To solve this problem, a Cauchy distribution weighted M-estimator is introduced to improve the robustness of the improved OS- RVFLNs. For this proposed robust OS-RVFLNs (R-OS- RVFLNs), since the weights of different outlier data are properly determined by the Cauchy distribution function, their corresponding contribution on modeling can be properly distinguished. Thus robust and better modeling results can be achieved. Experiments using actual industrial data of BF ironmaking process and comparative studies have demonstrated that the proposed method produces a better estimation accuracy and stronger robustness than other methods.

Blast furnace (BF), Modelling, Dynamic systems↗

A method for online verification of adapted fields using an independent dose monitor

Purpose: Clinical implementation of online adaptive radiotherapy requires generation of modified fields and a method of dosimetric verification in a short time. We present a method of treatment field modification to account for patient setup error, and an online method of verification using an independent monitoring system.Methods: The fields are modified by translating each multileaf collimator (MLC) defined aperture in the direction of the patient setup error, and magnifying to account for distance variation to the marked isocentre. A modified version of a previously reported online beam monitoring system, the integral quality monitoring (IQM) system, was investigated for validation of adapted fields. The system consists of a large area ion-chamber with a spatial gradient in electrode separation to provide a spatially sensitive signal for each beam segment, mounted below the MLC, and a calculation algorithm to predict the signal. IMRT plans of ten prostate patients have been modified in response to six randomly chosen setup errors in three orthogonal directions.Results: A total of approximately 49 beams for the modified fields were verified by the IQM system, of which 97% of measured IQM signal agree with the predicted value to within 2%.Conclusions: The modified IQM system was found to be suitable for online verification of adapted treatment fields.

61 RADIATION PROTECTION AND DOSIMETRY↗

MO-F-16A-03: AAPM Online Learning Support of New ABR MOC Requirements

In 2002 the American Board of Radiology (ABR) discontinued issuing lifetime board certification. After that time diplomates received a timelimited certificate and must participate in the Maintenance of Certification (MOC) program in order to maintain their certification. Initially certificates were issued with a 10 year expiration period and the MOC had requirements to be met over that 10 year period. The goal was to demonstrate continuous maintenance of clinical competency, however some diplomates were attempting to fulfill most or all of the requirements near the end of the 10 year period. This failed to meet the continuous aspect of the goal and so the ABR changed to a sliding 3-year window. This was done to recognize that not every year would be the same, but that diplomates should be able to maintain a reasonable average over any 3 year period.A second significant change occurred in 2013. The initial requirements included 20 selfassessment modules (SAMs) over the original 10 year term. SAMs are a special type of continuing education (CE) credit that were an addition to the 250 standard CE credits required over the 10 year period. In 2013, however, the new requirement is 75 CE credits over the previous 3 years, of which 25 must include self-assessment. Effectively this raised the self-assessment requirement from 20 in 10 years to 25 in 3 years. Previously SAMs were an interactive presentation available in limited quantities at live meetings. However, the new requirement is not for SAMs but CE-SA which includes SAMs, but also includes the online quizzes provided at the AAPM online learning center. All credits earned at the AAPM online learning center fulfill the ABR SA requirement.This talk will be an interactive demonstration of the AAPM online learning center along with a discussion of the MOC requirements.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

SU-E-I-58: Experiences in Setting Up An Online Fluoroscopy Tracking System in a Large Healthcare System

Purpose: Transitioning from a paper based to an online system for tracking fluoroscopic case information required by state regulation and to conform to NCRP patient dose tracking suggestions. Methods: State regulations require documentation of operator, equipment, and some metric of tube output for fluoroscopy exams. This information was previously collected in paper logs, which was cumbersome and inefficient for the large number of fluoroscopic units across multiple locations within the system. The “tech notes” feature within Siemens’ Syngo workflow RIS was utilized to create an entry form for technologists to input case information, which was sent to a third party vendor for archiving and display though an online web based portal. Results: Over 55k cases were logged in the first year of implementation, with approximately 6,500 cases per month once fully online. A system was built for area managers to oversee and correct data, which has increased the accuracy of inputted values. A high-dose report was built to automatically send notifications when patients exceed trigger levels. In addition to meeting regulatory requirements, the new system allows for larger scale QC in fluoroscopic cases by allowing comparison of data from specific procedures, locations, equipment, and operators so that instances that fall outside of reference levels can be identified for further evaluation. The system has also drastically improved identification of operators without documented equipment specific training. Conclusion: The transition to online fluoroscopy logs has improved efficiency in meeting state regulatory requirements as well as allowed for identification of particular procedures, equipment, and operators in need of additional attention in order to optimize patient and personnel doses, while high dose alerts improve patient care and follow up. Future efforts are focused on incorporating case information from outside of radiology, as well as on automating processes for increased efficiencies.

60 APPLIED LIFE SCIENCES↗

WE-D-BRA-04: Online 3D EPID-Based Dose Verification for Optimum Patient Safety

Purpose: To develop an online 3D dose verification tool based on EPID transit dosimetry to ensure optimum patient safety in radiotherapy treatments. Methods: A new software package was developed which processes EPID portal images online using a back-projection algorithm for the 3D dose reconstruction. The package processes portal images faster than the acquisition rate of the portal imager (∼ 2.5 fps). After a portal image is acquired, the software seeks for “hot spots” in the reconstructed 3D dose distribution. A hot spot is in this study defined as a 4 cm{sup 3} cube where the average cumulative reconstructed dose exceeds the average total planned dose by at least 20% and 50 cGy. If a hot spot is detected, an alert is generated resulting in a linac halt. The software has been tested by irradiating an Alderson phantom after introducing various types of serious delivery errors. Results: In our first experiment the Alderson phantom was irradiated with two arcs from a 6 MV VMAT H&N treatment having a large leaf position error or a large monitor unit error. For both arcs and both errors the linac was halted before dose delivery was completed. When no error was introduced, the linac was not halted. The complete processing of a single portal frame, including hot spot detection, takes about 220 ms on a dual hexacore Intel Xeon 25 X5650 CPU at 2.66 GHz. Conclusion: A prototype online 3D dose verification tool using portal imaging has been developed and successfully tested for various kinds of gross delivery errors. The detection of hot spots was proven to be effective for the timely detection of these errors. Current work is focused on hot spot detection criteria for various treatment sites and the introduction of a clinical pilot program with online verification of hypo-fractionated (lung) treatments.

60 APPLIED LIFE SCIENCES↗

WE-EF-BRA-07: High Performance Preclinical Irradiation Through Optimized Dual Focal Spot Dose Painting and Online Virtual Isocenter Radiation Field Targeting

Purpose: Advances in radiotherapy practice facilitated by collimation systems to shape radiation fields and image guidance to target these conformal beams have motivated proposals for more complex dose patterns to improve the therapeutic ratio. Recent progress in small animal radiotherapy platforms has provided the foundation to validate the efficacy of such interventions, but robustly delivering heterogeneous dose distributions at the scale and accuracy demanded by preclinical studies remains challenging. This work proposes a dual focal spot optimization method to paint spatially heterogeneous dose regions and an online virtual isocenter targeting method to accurately target the dose distributions. Methods: Two-dimensional dose kernels were empirically measured for the 1 mm diameter circular collimator with radiochromic film in a solid water phantom for the small and large x-ray focal spots on the X-RAD 225Cx microirradiator. These kernels were used in an optimization framework which determined a set of animal stage positions, beam-on times, and focal spot settings to optimally deliver a given desired dose distribution. An online method was developed which defined a virtual treatment isocenter based on a single image projection of the collimated radiation field. The method was demonstrated by optimization of a 6 mm circular 2 Gy target adjoining a 4 mm semicircular avoidance region. Results: The dual focal spot technique improved the optimized dose distribution with the proportion of avoidance region receiving more than 0.5 Gy reduced by 40% compared to the large focal spot technique. Targeting tests performed by irradiating ball bearing targets on radiochromic film pieced revealed the online targeting method improved the three-dimensional accuracy from 0.48 mm to 0.15 mm. Conclusion: The dual focal spot optimization and online virtual isocenter targeting framework is a robust option for delivering dose at the preclinical level and provides a new experimental option for unique radiobiological investigations This work is supported, in part, by the Natural Sciences and Engineering Research Council of Canada and a Mitacs-Accelerate fellowship. P.E. Lindsay, and D.A. Jaffray are listed as inventors of the system described herein. This system has been licensed to Precision X-Ray Inc. for commercial development.

60 APPLIED LIFE SCIENCES↗

MO-E-BRC-00: Online Adaptive Radiotherapy - Considerations for Practical Clinical Implementation

Online adaptive radiation therapy has the potential to ensure delivery of optimal treatment to the patient by accounting for anatomical and potentially functional changes that occur from one fraction to the next and over the course of treatment. While on-line adaptive RT (ART) has been a topic of many publications, discussions, and research, it has until very recently remained largely a concept and not a practical implementation. However, recent advances in on-table imaging, use of deformable image registration for contour generation and dose tracking, faster and more efficient plan optimization, as well as fast quality assurance method has enabled the implementation of ART in the clinic in the past couple of years. The introduction of these tools into routine clinical use requires many considerations and progressive knowledge to understand how processes that have historically taken hours/days to complete can now be done in less than 30 minutes. This session will discuss considerations to perform real time contouring, planning and patient specific QA, as well as a practical workflow and the required resources. Learning Objectives: To understand the difficulties, challenges and available technologies for online adaptive RT. To understand how to implement online adaptive therapy in a clinical environment and to understand the workflow and resources required. To understand the limitations and sources of uncertainty in the online adaptive process I have research funding from ViewRay Inc. and Philips Medical Systems.; R. Kashani, I have research funding from ViewRay Inc. and Philips Medical Systems.; X. Li, Research supported by Elekta Inc.

60 APPLIED LIFE SCIENCES↗

MO-E-BRC-01: Online Adaptive MR-Guided RT: Workflow and Clinical Implementation

Online adaptive radiation therapy has the potential to ensure delivery of optimal treatment to the patient by accounting for anatomical and potentially functional changes that occur from one fraction to the next and over the course of treatment. While on-line adaptive RT (ART) has been a topic of many publications, discussions, and research, it has until very recently remained largely a concept and not a practical implementation. However, recent advances in on-table imaging, use of deformable image registration for contour generation and dose tracking, faster and more efficient plan optimization, as well as fast quality assurance method has enabled the implementation of ART in the clinic in the past couple of years. The introduction of these tools into routine clinical use requires many considerations and progressive knowledge to understand how processes that have historically taken hours/days to complete can now be done in less than 30 minutes. This session will discuss considerations to perform real time contouring, planning and patient specific QA, as well as a practical workflow and the required resources. Learning Objectives: To understand the difficulties, challenges and available technologies for online adaptive RT. To understand how to implement online adaptive therapy in a clinical environment and to understand the workflow and resources required. To understand the limitations and sources of uncertainty in the online adaptive process I have research funding from ViewRay Inc. and Philips Medical Systems.; R. Kashani, I have research funding from ViewRay Inc. and Philips Medical Systems.; X. Li, Research supported by Elekta Inc.

60 APPLIED LIFE SCIENCES↗

MO-E-BRC-02: MRI-Guided Online Adaptive Radiotherapy: The UCLA Approach to Quality Management

Online adaptive radiation therapy has the potential to ensure delivery of optimal treatment to the patient by accounting for anatomical and potentially functional changes that occur from one fraction to the next and over the course of treatment. While on-line adaptive RT (ART) has been a topic of many publications, discussions, and research, it has until very recently remained largely a concept and not a practical implementation. However, recent advances in on-table imaging, use of deformable image registration for contour generation and dose tracking, faster and more efficient plan optimization, as well as fast quality assurance method has enabled the implementation of ART in the clinic in the past couple of years. The introduction of these tools into routine clinical use requires many considerations and progressive knowledge to understand how processes that have historically taken hours/days to complete can now be done in less than 30 minutes. This session will discuss considerations to perform real time contouring, planning and patient specific QA, as well as a practical workflow and the required resources. Learning Objectives: To understand the difficulties, challenges and available technologies for online adaptive RT. To understand how to implement online adaptive therapy in a clinical environment and to understand the workflow and resources required. To understand the limitations and sources of uncertainty in the online adaptive process I have research funding from ViewRay Inc. and Philips Medical Systems.; R. Kashani, I have research funding from ViewRay Inc. and Philips Medical Systems.; X. Li, Research supported by Elekta Inc.

60 APPLIED LIFE SCIENCES↗

MO-E-BRC-03: Fast Online Replanning Techniques

Online adaptive radiation therapy has the potential to ensure delivery of optimal treatment to the patient by accounting for anatomical and potentially functional changes that occur from one fraction to the next and over the course of treatment. While on-line adaptive RT (ART) has been a topic of many publications, discussions, and research, it has until very recently remained largely a concept and not a practical implementation. However, recent advances in on-table imaging, use of deformable image registration for contour generation and dose tracking, faster and more efficient plan optimization, as well as fast quality assurance method has enabled the implementation of ART in the clinic in the past couple of years. The introduction of these tools into routine clinical use requires many considerations and progressive knowledge to understand how processes that have historically taken hours/days to complete can now be done in less than 30 minutes. This session will discuss considerations to perform real time contouring, planning and patient specific QA, as well as a practical workflow and the required resources. Learning Objectives: To understand the difficulties, challenges and available technologies for online adaptive RT. To understand how to implement online adaptive therapy in a clinical environment and to understand the workflow and resources required. To understand the limitations and sources of uncertainty in the online adaptive process I have research funding from ViewRay Inc. and Philips Medical Systems.; R. Kashani, I have research funding from ViewRay Inc. and Philips Medical Systems.; X. Li, Research supported by Elekta Inc.

60 APPLIED LIFE SCIENCES↗

TH-CD-202-12: Online Inter-Beam Replanning Based On Real-Time Dose Reconstruction

Purpose: This work provides a proof-of-concept study for online replanning during treatment delivery for step-and-shoot prostate SBRT, based on real-time dose reconstruction. Online replanning is expected to improve the trade-off between target coverage and organ-at-risk dose in the presence of intra-fractional motion. Methods: We have implemented an online replanning workflow on top of our previously reported real-time dose reconstruction software which connects to an Elekta research linac. The treatment planning system DynaPlan was extended to (1) re-optimize and sequence treatment plans (in clockwise beam order) before each beam, based on actual delivered dose, in a timeframe limited by the gantry rotation between subsequent beams, and (2) send the respective segments to the delivery control software DynaTrack which starts/continues treatment immediately.To investigate the impact of a reduced safety margin, we have created and delivered (on a linac emulator) a conventional CTV+5/3mm (I) and a reduced CTV+1mm margin (II) treatment plan for a prostate patient. We have assessed CTV coverage with and without inter-beam replanning, all exposed to a gradual target shift of 0–5mm in posterior and inferior direction from start until the end of delivery. Results: For the reconstructed conventional plan (I), D98 for CTV was 100% of D98 of the planned dose. For the reconstructed margin-reduced plan (II), D98 for CTV was 95% of the planned D98 without replanning, but could be recovered to 99% by replanning for each beam. Plan (II) with replanning resulted in a decrease for bladder V90% by 88% and an increase to rectum V90% by 9% compared to the conventional plan (I). Dose calculation/accumulation was performed in <15ms per MLC aperture, replanning in <15s per beam. Conclusion: We have shown that online inter-beam replanning is technically feasible and potentially allows for a margin reduction. Future investigation considering motion-robust replanning optimization parameters is in progress. We acknowledge support of the MLC research from Elekta AB. This work is supported by Cancer Research UK under Programme C33589/A19908. Research at ICR is also supported by Cancer Research UK under Programme C33589/A19727 and NHS funding to the NIHR Biomedical Research Centre at RMH and ICR.

60 APPLIED LIFE SCIENCES↗

Adaptive Cybersecurity for Distributed Energy Resources (AdCyDER): Online Reinforcement Learning with Stackelberg-Optimized Defenses — Pipeline Architecture, Evaluation Methodology, and Findings from a Synthetic-Data Evaluation

This report documents the design and evaluation of an integrated online-learning pipeline developed within the AdCyDER project for Distributed Energy Resource (DER) cybersecurity. The pipeline couples a Reinforcement Learning (RL) attack classifier — which produces an attack-type probability distribution — with a Stackelberg game-theoretic (GT) defense selector that consumes those distributions alongside SME-encoded priors over (defense, attack) effectiveness pairings and perdefense costs to choose grid-health-preserving defenses. The objective is not attack classification per se but production of distributions that drive effective defense selection through the Stackelberg layer, learned from delayed grid-health feedback rather than labeled attack data. AdCyDER as a whole is broader than the work presented here; this report covers the specific RL/GT loop integration and its evaluation. We present the integrated pipeline (SCADA telemetry with Fronius inverter physics, Suricata IDS, time-windowed aggregation, per-facility LSTM classifier, Stackelberg optimizer, OpenC2 actuators), an experimental campaign of 28 eight-hour iterations across three baseline modes, and a pipeline-ordered diagnostic protocol. The protocol identifies two distinct failure modes within the loop: paired supervised ceilings on the same features establish that the deployed online RL classifier (macro F1 ≈ 0.07) sits at least 4.7× below a same-architecture supervised LSTM (≈ 0.34) and 10–11× below a linear feature-signal ceiling (≈ 0.70–0.79 depending on per-facility isolation), localizing the dominant failure to the training procedure; and the reward signal driving online updates carries weak directional coupling with classifier correctness in the methodology-expected direction (multi-lens convergent: top-decile P(true) records produce more frequent state changes and slightly larger improvements, top-vs-bot Cohen’s 𝑑 ≈ −0.19), but at effect magnitudes too small to drive gradient-based learning at the campaign sample size. The original learning hypothesis is not supported by the data. The primary contributions are the diagnostic methodology — proposed as a transferable falsification protocol for online RL/GT defense pipelines learning from delayed environmental reward — and the open, reproducible experimental infrastructure. We outline reward reformulation as the highest-priority aspirational next step given the underpowered-but-aligned Q6 reading, with hardware-in-the-loop evaluation as the broadest scope-expansion option.

Blakely, Benjamin [Argonne National Laboratory (AN↗

An Experiment with LLMs as Database Design Tutors: Persistent Equity and Fairness Challenges in Online Learning

As large language models (LLMs) continue to evolve, their capacity to replace humans as their surrogates is also improving. As increasing numbers of intelligent tutoring systems (ITSs) are embracing the integration of LLMs for digital tutoring, questions are arising as to how effective they are and if their hallucinatory behaviors diminish their perceived advantages. One critical question that is seldom asked if the availability, plurality, and relative weaknesses in the reasoning process of LLMs are contributing to the much discussed digital divide and equity and fairness in online learning. In this paper, we present an experiment with database design theory assignments and demonstrate that while their capacity to reason logically is improving, LLMs are still prone to serious errors. We demonstrate that in online learning and in the absence of a human instructor, LLMs could introduce inequity in the form of “wrongful” tutoring that could be devastatingly harmful for learners, which we call ignorant bias, in increasingly popular digital learning. We also show that significant challenges remain for STEM subjects, especially for subjects for which sound and free online tutoring systems exist. Based on the set of use cases, we formulate a possible direction for an effective ITS for online database learning classes of the future.

Jamil, Hasan M. (ORCID:0000000231243780)↗

A Gaussian Process Based Online Change Detection Algorithm for Monitoring Periodic Time Series

Online time series change detection is a critical component of many monitoring systems, such as space and air-borne remote sensing instruments, cardiac monitors, and network traffic profilers, which continuously analyze observations recorded by sensors. Data collected by such sensors typically has a periodic (seasonal) component. Most existing time series change detection methods are not directly applicable to handle such data, either because they are not designed to handle periodic time series or because they cannot operate in an online mode. We propose an online change detection algorithm which can handle periodic time series. The algorithm uses a Gaussian process based non-parametric time series prediction model and monitors the difference between the predictions and actual observations within a statistically principled control chart framework to identify changes. A key challenge in using Gaussian process in an online mode is the need to solve a large system of equations involving the associated covariance matrix which grows with every time step. The proposed algorithm exploits the special structure of the covariance matrix and can analyze a time series of length T in O(T^2) time while maintaining a O(T) memory footprint, compared to O(T^4) time and O(T^2) memory requirement of standard matrix manipulation methods. We experimentally demonstrate the superiority of the proposed algorithm over several existing time series change detection algorithms on a set of synthetic and real time series. Finally, we illustrate the effectiveness of the proposed algorithm for identifying land use land cover changes using Normalized Difference Vegetation Index (NDVI) data collected for an agricultural region in Iowa state, USA. Our algorithm is able to detect different types of changes in a NDVI validation data set (with ~80% accuracy) which occur due to crop type changes as well as disruptive changes (e.g., natural disasters).

54 ENVIRONMENTAL SCIENCES↗

Online Condition Monitoring to Enable Extended Operation of Nuclear Power Plants

Safe, secure, and economic operation of nuclear power plants will remain of strategic significance. New and improved monitoring will likely have increased significance in the post-Fukushima world. Prior to Fukushima, many activities were already underway globally to facilitate operation of nuclear power plants beyond their initial licensing periods. Decisions to shut down a nuclear power plant are mostly driven by economic considerations. Online condition monitoring is a means to improve both the safety and economics of extending the operating lifetimes of nuclear power plants, enabling adoption of proactive aging management. With regard to active components (e.g., pumps, valves, motors, etc.), significant experience in other industries has been leveraged to build the science base to support adoption for online condition-based maintenance and proactive aging management in the nuclear industry. Many of the research needs are associated with enabling proactive management of aging in passive components (e.g., pipes, vessels, cables, containment structures, etc.). This paper provides an overview of online condition monitoring for the nuclear power industry with an emphasis on passive components. Following the overview, several technology/knowledge gaps are identified, which require addressing to facilitate widespread online condition monitoring of passive components.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗