Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “office building”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Peak cooling load shift capability of a thermal energy storage system integrated with an active insulation system in US climate zones

This study aims to evaluate a thermal energy storage (TES) system integrated with an active insulation system (AIS) to form a TES + AIS integrated wall system as a partition and as a secondary cooling system to shift the peak load and reduce cooling energy consumption. To understand and demonstrate its cooling performance, the TES + AIS integrated wall system was installed in an office building in Oak Ridge, Tennessee. To investigate the effect of the TES + AIS integrated wall system in a typical office building and various climate zones, the US Department of Energy’s prototype office building model was modified to accommodate the proposed system. In this work, results showed that the minimum size of the proposed system to achieve energy savings varies depending on climate conditions. The minimum size of the proposed system for cooling energy saving and shifting peak cooling demand in climate zones 2, 3, and 5 is 29.7 m 2 , whereas it is 44.6 m 2 in zones 4 and 6. By installing the minimum size of the proposed system, 11.3 % to 16.4 % of cooling energy can be shifted during discharge hours in a representative summer day.

25 ENERGY STORAGE↗

Enhancing Building Resilience: Maintaining Energy Efficiency and Thermal Comfort During Power Outages in Cold Climates

The increasing frequency and intensity of extreme weather events, such as heatwaves and cold snaps, present significant challenges to building energy performance and occupant comfort. Highly correlated with climate events are widespread long duration power interruptions that may affect thousands of buildings and millions of customers. This study evaluates the impact of building energy performance and occupant thermal comfort in medium-sized office buildings in a cold climate region. Using energy models representing pre-1980 and 2019 vintages, simulations were conducted to assess energy performance under typical weather conditions and occupant thermal comfort during power interrupted extreme cold snap and heatwave climate events under both current 2020s and future 2050s weather conditions. The results show a projected 33% increase in cooling energy demand and a 19% reduction in heating energy by 2050. Findings reveal that older buildings are more susceptible to cold discomfort during cold snaps, while modern airtight buildings are more vulnerable to overheating during heatwaves. Various passive energy efficiency measures, such as improved infiltration control, thermal windows, solar-controlled windows, and cool envelopes, were evaluated for their ability to mitigate thermal discomforts. Solar controlled windows and weatherstripping contribute to reducing cold thermal discomfort by 21% during a power-interrupted cold snap. Solar-controlled windows were found to reduce hot thermal discomfort by 34% during a future power-interrupted heatwave. The study highlights the importance of targeted retrofitting strategies to enhance thermal resilience, especially during power outages, to ensure occupant safety and comfort during extreme climate events.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Operation and performance of VRF systems: Mining a large-scale dataset

The energy consumption of air-conditioning systems has gained increasing attention as it contributes significantly to the global building energy use. The variable refrigerant flow (VRF) system is a common air-conditioning system applied widely in residential and office buildings in China. Understanding the actual operation and performance of VRF systems is fundamental for the energy-efficient design and operation of VRF systems. Previous research on VRF system operation used either limited field data covering certain building types and climate zones or used a questionnaire to obtain a larger dataset. However, they did not capture the wide applications of VRF systems quantitatively across all building types, climate zones, and operating conditions. To fill this gap, statistical and clustering analysis was conducted on the newly proposed key performance indicators of approximately 287,000 VRF systems for residential and commercial buildings in all five climate zones in China. In this work, the main findings are: (1) VRF systems are mainly used for cooling in all climate zones in China; (2) among all building types, the duration of use is lowest in residential buildings and highest in hotels and medical buildings; (3) the distribution of the ideal VRF cooling coefficient of performance (COP) is similar across all climate zones and building types; whereas the COPs of ideal VRF heating in the Severe Cold region and Cold regions are lower than those in other climate zones; and (4) partial load operations for VRF systems are common in residential buildings and office buildings due to the part-time-part-space operation mode. These findings can inform the actual application of VRF systems in China, supporting the design, operation, industry standard development, and performance optimization of VRF systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Solar heating system installed at Stamford, Connecticut

The solar heating system installed at the Lutz-Sotire Partnership Executive East Office Building, Stamford, Connecticut is described. The Executive East Office Building is of moderate size with 25,000 sq ft of heated space in 2 1/2 stories. The solar system was designed to provide approximately 50 percent of the heating requirements. The system components are described. Appended data includes: the system design acceptance test, the operation and maintenance manual, and as-built drawings and photographs.

Source record↗

Results of Outdoor to Indoor Propagation Measurements from 5-32GHz

The demand for wireless services has increased exponentially in the last few years and shows no signs of slowing in the near future. In order for the next generation wireless to provide seamless access, whether the user is indoors or out, a thorough understanding and validation of models describing the impact of building entry loss (BEL) is required. This information is currently lacking and presents a challenge for most system designers. For this reason empirical data is needed to assess the impact of BEL at frequencies that are being explored for future mobile broadband applications This paper present the results of measurements of outdoor-to-indoor propagation from 5-32 GHz in three different buildings. The first is a newer building that is similar in construction to modern residential home. The second is an older commercial office building. The last building is a very new commercial office building built using modern green building techniques. These three buildings allow for the measurement of propagation losses through both modern and older materials; such as glass windows and exterior block and siding. Initial results found that at particular spatial locations the BEL could be less than 1dB or more than 70dB with free space losses discounted (this is likely influenced by multipath). Additionally, it was observed that the PDF distributions of a majority of the measurements trended toward log-normal with means and standard deviations ranging from 8-38dB and 6-14dB, respectively.

building entry loss↗

Unified architecture for data-driven metadata tagging of building automation systems

This article presents a Unified Architecture (UA) for automated point tagging of Building Automation System (BAS) data, based on a combination of data-driven approaches. Advanced energy analytics applications—including fault detection and diagnostics and supervisory control—have emerged as a significant opportunity for improving the performance of our built environment. Effective application of these analytics depends on harnessing structured data from the various building control and monitoring systems, but typical BAS implementations do not employ any standardized metadata schema. While standards such as Project Haystack and Brick Schema have been developed to address this issue, the process of structuring the data, i.e., tagging the points to apply a standard metadata schema, has, to date, been a manual process. This process is typically costly, labor-intensive, and error-prone. In this work we address this gap by proposing a UA that automates the process of point tagging by leveraging the data accessible through connection to the BAS, including time-series data and the raw point names. The UA intertwines supervised classification and unsupervised clustering techniques from machine learning and leverages both their deterministic and probabilistic outputs to inform the point tagging process. Furthermore, we extend the UA to embed additional input and output data-processing modules that are designed to address the challenges associated with the real-time deployment of this automation solution. We test the UA on two datasets for real-life buildings: (i) commercial retail buildings and (ii) office buildings from the National Renewable Energy Laboratory (NREL) campus. We report the proposed methodology correctly applied 85–90% and 70–75% of the tags in each of these test scenarios, respectively for two significantly different building types used for testing UA's fully-functional prototype. The proposed UA, therefore, offers promising approach for automatically tagging BAS data as it reaches close to 90% accuracy. Further building upon this framework to algorithmically identify the equipment type and their relationships is an apt future research direction to pursue.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Empirically Categorizing the Built Environment in Relation to Height

Buildings are a core component of the urban environment and affect human populations, energy usage, city development, city planning, and urban heat islands. Buildings span an enormous range of sizes, from a 2m tall shelter to the Burj Khalifa; and at the same time there are widely recognized categories of similar buildings, with homes, office buildings, or skyscrapers as some examples. Currently, there is no consistent method to quantitatively determine how a building should be categorized by its height, or how many categories there should be within the built environment. Additionally, these categories vary spatially, leading to multiple definitions at local scales of what it means to be a tall, medium, or short building. Here, we find across 17.59 million buildings in the United States, Germany, and Japan, that applying a K-nearest neighbor approach to quantitatively bin the built environment outperforms the current state-of-the-art, subjective domain knowledge. This was evidenced as our method of leveraging a K-nearest neighbor improved upon the existing approach of using domain knowledge by 10% with respect to precision, recall, F1-score and accuracy. Our results showcase the finding that it is possible to generate a global and consistent approach to categorizing the built environment in relation to height. This is significant in that there is now a quantitative way to categorize the built environment based on building height at a global scale, allowing researchers a consistent platform for comparison and collaboration across various applications.

Stipek, Clinton↗

Optimal Energy Dispatch Controller for Fuel Cell-Integrated Multi-Zone Building

Stationary fuel cells provide potential opportunities for energy savings when integrated with buildings. Through smart dispatch of both electrical power and heat generated by the fuel cells and managing the building loads, the buildings can achieve more efficient operation. In this paper, we develop an optimal energy dispatch controller to operate a fuel cell-integrated building. The controller leverages the inherent thermal storage and the dispatchable fuel cell to reduce its operating cost and to allow the building to participate in grid services. The proposed controller is implemented on two types of commercial buildings, a large office building and a large hotel, and the effectiveness of the controller is demonstrated through simulations. The results also indicate that the potential saving varies significantly with different system parameters, including season, fuel prices, and equipment sizing, which provide helpful insights for building operators and other stake holders.

39 EE - Hydrogen and Fuel Cell Technologies (EE-3F↗

A Comprehensive Analysis of Energy and Daylighting Impact of Window Shading Systems and Control Strategies on Commercial Buildings in the United States

Commercial buildings consume approximately 1.9 EJ of energy in the United States, 50% of which is for heating, cooling, and lighting applications. It is estimated that windows contribute up to 34% of the energy used for heating and cooling. However, window retrofits are not often undertaken to increase energy efficiency because of the high cost and disruptive nature of window installation. Highly efficient window technologies would also need shading devices for glare prevention and visual comfort. An automated window shading system with an appropriate control strategy is a technology that can reduce energy demand, maintain occupant comfort, and enhance the aesthetics and privacy of the built environment. However, the benefits of the automated shades currently used by the shading industry are not well studied. The topic merits an analysis that will help building owners, designers and engineers, and utilities make informed decisions using knowledge of the impact of this technology on energy consumption, peak demand, daylighting, and occupant comfort. This study uses integrated daylight and whole-building energy simulation to evaluate the performance of various control strategies that the shading industry uses in commercial office buildings. The analysis was performed for three different vintages of medium office buildings at six different locations in United States. The results obtained show the control strategies enabled cooling energy savings of up to 40% using exterior shading, and lighting energy savings of up to 25%. The control strategies described can help building engineers and researchers explore different control methods used to control shading in actual buildings but rarely discussed in the literature. This information will give researchers the opportunity to investigate potential improvements in current technologies and their performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Initial operation of a solar heating and cooling system in a full-scale solar building test facility

The Solar Building Test Facility (SBTF) was constructed to advance the technology for heating and cooling of office buildings with solar energy. Its purposes are to (1) test system components which include high-performing collectors, (2) test the performance of a complete solar heating and cooling system, (3) investigate component interactions, and (4) investigate durability, maintenance and reliability of components. The SBTF consists of a 50,000 square foot office building modified to accept solar heated water for operation of an absorption air conditioner and for the baseboard heating system. A 12,666 square foot solar collector field with a 30,000 gallon storage tank provides the solar heated water. A description of the system and the collectors selected is printed along with the objectives, test approach, expected system performance, and some preliminary results.

Knoll, R. H.↗

Physics-constrained Deep Recurrent Neural Models of Building Thermal Dynamics

We develop physics-constrained and control-oriented predictive deep learning models for the thermal dynamics of a real-world commercial office building. The proposed method is based on the systematic encoding of physics-based prior knowledge into a structured recurrent neural architecture. Specifically, our model mimics the structure of the building thermal dynamics model and leverages penalty methods to model inequality constraints. Additionally, we use constrained matrix parameterization based on the Perron-Frobenius theorem to bound the eigenvalues of the learned network weights. We interpret the stable eigenvalues as dissipativeness of the learned building thermal model. We demonstrate the effectiveness of the proposed approach on a dataset obtained from an office building with $20$ thermal zones.

Building Energy, structured neural networks↗

Individualized empirical baselines for evaluating the energy performance of existing buildings

The evaluation of building energy performance requires a baseline for comparison. Common empirical baselines are usually used for existing buildings since they are fast and convenient. However, the same type of building at the same location will receive the same baseline despite their difference in usage. Individualized baselines by creating building energy models are possible solutions, but it is labor intensive and time-consuming. To fill the gap, this study is to develop individualized empirical baselines for existing buildings in a fast way. First, common empirical baselines are created based on survey data. Then, to get training samples, building energy models for large-scale existing buildings are created and simulated. So finally, based on simulation results, mathematical models to get individualized empirical baselines in a fast way are created. U.S. medium office buildings were used as an example to demonstrate the method. We developed 30 mathematical models for medium office buildings in two vintages (constructed before 1980 and after 1980) and 15 climate zones. The mean absolute percentage errors (MAPE) between the individualized empirical baselines and the modeled baselines for those 30 mathematical models are all lower than 5.5%. An engineer can obtain the individualized empirical baseline for an existing building in a few seconds by using the open-source tool we developed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

BOPTEST: Initial FRP Test Case Development

To support an emulator model development of Building Optimization Testing (BOPTEST) framework, a team at the US Department of Energy’s Oak Ridge National Laboratory developed a medium-sized office building written in Modelica to serve as a reference test case. The reference test case was modeled based on an actual research platform that represents a typical medium-sized office building. This test case would encourage model-based design and testing of new controllers in which a developer first prototypes and debugs on a model before implementing in the real world. The developed preliminary model and control parameters will be further calibrated and tuned with actual measured data from experiments

42 ENGINEERING↗

The interactive indoor-outdoor building energy modeling for enhancing the predictions of urban microclimates and building energy demands

There is a lack of an urban building energy modeling framework that considers the influence of surrounding buildings and local urban climate on building thermal performance. This can lead to inaccurate results since the thermal performance of individual buildings is heavily influenced by their surrounding built and climatic environment. This study establishes an interactive indoor-outdoor building energy modeling method to enhance the predictions of urban microclimates and building energy demands by coupling an urban physics model with a physics-based building energy model. Validation of the interactive coupling scheme uses field measurement datasets. Parametric simulation and analysis are conducted to understand the influence of the roof-to-canyon width ratio, canyon orientation, and ground vegetation fraction on canyon temperature, building energy consumption, and energy demand. Furthermore, the impacts of building energy model complexity (e.g., detailed vs. simplified building models) and coupling approaches on canyon temperature and building energy profiles are demonstrated using two case study buildings. In comparison with the one-way coupling approach, cooling energy consumption predicted with the dynamic two-way coupling approach varies by 3.5% and 0.5% for the detailed medium office building model and high-rise building model, respectively, and peak cooling demand varies by 8.4% and 7.0% for the detailed medium office building model and high-rise building model, respectively. Here this study also suggests that adopting a complex two-way coupling approach with environmental data exchange at various elevations is necessary for modeling tall buildings at the urban scale.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessing Cost-Optimal Battery Energy and Solar-Plus-Storage Systems for Federal Customers: A Nationwide Assessment: Preprint

Prior research has identified that the financial viability of behind-the-meter battery energy storage systems is heavily dependent on technology cost, utility rate structure, energy consumption patterns, and co-deployment with synergistic technologies like solar photovoltaics (PV), among other factors. This study builds on existing research by comprehensively evaluating the economics of battery energy storage systems (BESS) and solar-plus-storage systems for a reference office building at 755 reference sites under 834 utility rates, and four storage capital cost scenarios. Results indicate that even with dramatic cost reductions, BESS is likely to be cost-effective only under utility rates that include demand charges, and possibly include time-of-use (TOU) pricing as well. Even under these utility rates, BESS systems provide marginal savings, and office building operators are unlikely to deploy the technology for cost savings alone. Solar-plus-storage systems provide more savings than BESS and allow for larger economic storage capacities. Solar-plus-storage provides compelling savings opportunities at baseline prices, and even at capital costs 25% higher than baseline. Solar-plus-storage is most effective where there are demand charges and energy pricing schemes include TOU pricing, or where electricity is expensive (at least $0.30/kWh). Our case studies illustrate that the presence of demand charges, even at similar energy costs, can be the deciding factor in BESS and solar-plus-storage viability. The findings and maps from this assessment may be of use to planners, building owners, and developers looking for potentially economic storage opportunities.

battery energy storage systems↗

Micro-Environmental Control System (Final Report)

This project developed an innovative micro-environmental control system (µX) that enables office buildings to reduce energy used for heating and cooling by 15% or more. The µX is a compact, quiet, and ergonomic device that is designed to be installed under an office workstation; it is designed to maintain occupant comfort when room thermostat setpoints are incremented by 4°F or more (warmer in the summer and cooler in the winter) to save energy. When ambient room temperatures are outside of the usual comfort range, the µX maintains occupant comfort by delivering personalized cooling or heating locally to each office worker. The µX provides personalized cooling using a micro vapor compression system that includes a new high-performance micro-scroll compressor and a novel thermal storage unit. The vapor compression system operates at night to freeze a phase-change material (PCM). During the workday, the cooling stored in the PCM is released as a cool breeze of air to make occupants more comfortable. The micro-scroll compressor was developed specifically for this application; it is smaller than any of its type, minimizing the amount of power needed. In heating mode, the µX maintains occupant comfort using a foot heating mat with an infrared reflective box. The µX R&D project was conducted by Syracuse University in collaboration with United Technologies Research Center, Air Innovations, Bush Technical, and Cornell University. Over the course of the initial three-year project, the team developed and evaluated four versions of the unit, advancing the concept to Technology Readiness Level 6. The capabilities of individual proof-of-concept prototypes were verified in tests that were conducted with: 1) units in psychrometric chambers, 2) an instrumented manikin in a laboratory, and 3) human subjects in laboratories that simulate office environments. The tests verified that the µX prototypes met or exceeded all performance targets required to enable office buildings to reduce energy used for heating and cooling by 15% or more by maintaining occupant comfort when thermostat setpoints are incremented by 4°F or more.

25 ENERGY STORAGE↗

Initial operation of a solar heating and cooling system in a full-scale solar building test facility

The Solar Building Test Facility (SBTF) located at Hampton, Virginia became operational in early summer of 1976. This facility is a joint effort by NASA-Lewis and NASA-Langley to advance the technology for heating and cooling of office buildings with solar energy. Its purposes are to (1) test system components which include high-performing collectors, (2) test performance of complete solar heating and cooling system, (3) investigate component interactions and (4) investigate durability, maintenance and reliability of components. The SBTF consists of a 50,000 square foot office building modified to accept solar heated water for operation of an absorption air conditioner and for the baseboard heating system. A 12,666 square foot solar collector field with a 30,000 gallon storage tank provides the solar heated water. A description of the system and the collectors selected is given here, along with the objectives, test approach, expected system performance and some preliminary results.

Knoll, R. H.↗

Propagation Characteristics of International Space Station Wireless Local Area Network

This paper describes the application of the Uniform Geometrical Theory of Diffraction (UTD) for Space Station Wireless Local Area Networks (WLANs) indoor propagation characteristics analysis. The verification results indicate good correlation between UTD computed and measured signal strength. It is observed that the propagation characteristics are quite different in the Space Station modules as compared with those in the typical indoor WLANs environment, such as an office building. The existing indoor propagation models are not readily applicable to the Space Station module environment. The Space Station modules can be regarded as oversized imperfect waveguides. Two distinct propagation regions separated by a breakpoint exist. The propagation exhibits the guided wave characteristics. The propagation loss in the Space Station, thus, is much smaller than that in the typical office building. The path loss model developed in this paper is applicable for Space Station WLAN RF coverage and link performance analysis.

Sham, Catherine C.↗