Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “occupancy sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Extending the Brick schema to represent metadata of occupants

Here, energy-related behaviors of occupants constitute a key factor influencing building performance; accordingly, the measured occupant data can support the objective assessment of the indoor environment and energy performance of buildings, which can inform building design and operational decisions. Existing data schemas focus on metadata of sensors, meters, physical equipment, and IoT devices in buildings; however, they are limited in representing the metadata of occupant data, including occupants' presence in spaces, movement between spaces, interactions with building systems or IoT devices, and preference of indoor environmental needs. To address this gap, an extension to the widely adopted metadata schema, Brick, is proposed to represent the contextual, behavioral, and demographic information of occupants. The proposed extension includes four parts: (1) a new “Occupant” class to represent occupants' demography and energy related behavioral patterns, (2) new subclasses under the Equipment class to represent envelope system and personal thermal comfort devices, (3) new subclasses under the Point class to represent occupant sensing and status, and (4) new auxiliary properties for occupant interactable equipment to represent the level of controllability for each piece of equipment by occupants. The extension is implemented in the Brick schema and has been tested using multiple occupant datasets from the ASHRAE Global Occupant Database. The extension enables Brick schema to capture diverse types of occupant sensing data and their metadata for FAIR data research and applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Carbon Monoxide Sensor

The fuel cell is a system which employs an electrochemical process to convert gases- J such as hydrogen and oxygen directly into electricity. Under NASA sponsorship, GE's Aircraft Equipment Division developed fuel cells to supply electrical power for the Gemini and Biosatellite spacecraft of the sixties and is currently working on advanced fuel cell development. This long-term effort has resulted in a series of spinoff applications using the same general technology for a variety of purposes, among them the recently marketed Dosimeter. The Dosimeter is designed to help users meet safety requirements for industrial atmospheres, as specified by the Occupational Safety and Health Administration and other regulatory agencies. The compact, pocket-sized sensor measures personnel exposure to carbon monoxide and provides both a visual and an audible alarm if the concentration of the gas exceeds present levels. The Dosimeter offers substantial improvement in measuring accuracy over earlier warning indicators.

Source record↗

Development of ASTM International D8405—Standard Test Method for Evaluating PM 2.5 Sensors or Sensor Systems Used in Indoor Applications

Sensors and sensor systems for monitoring fine particles with aerodynamic diameters smaller than 2.5 µm can provide real-time feedback on indoor air quality and thus can help guide actions to manage indoor air pollutant concentrations. Standardized verification of the performance and accuracy of sensors and sensor systems is crucial for predicting the efficacy of such monitoring. A new ASTM International standard test method (ASTM D8405) was created for this need and is the most exacting laboratory protocol published to date for evaluating indoor air quality sensors and sensor systems measuring particles smaller than 2.5 µm in diameter. ASTM D8405 subjects sensors and sensor systems to five test phases: (1) an initial particle concentration ramp; (2) exposure to various temperature and humidity conditions; (3) exposure to interfering particles; (4) temperature cycling; and (5) a final particle concentration ramp to assess drift. This paper discusses the development of the standard test method, key aspects of the testing process, example evaluation results, and a comparison of this standard test method against peer evaluation protocols.

47 OTHER INSTRUMENTATION↗

Dialogue Between Lighting and HVAC Systems: Improving building system integration

Lighting systems have long been capable of sensing when someone enters or exits a room and using that knowledge to turn lights on or off. More recently, connected lighting systems with sensors integrated into every luminaire have become broadly available, facilitating highly granular occupancy detection. Similarly, HVAC systems have long been able to use an understanding of building occupancy to adjust temperature setpoints and reduce energy use without significant impacts to occupant comfort. Energy codes (e.g., ASHRAE/IES Standard 90.1, IECC, Title 24) now require “occupied standby HVAC control,” whereby systems adjust both temperature and ventilation setpoints in zones that are determined to be unoccupied during normal occupancy hours. Here, this article discusses current issues that stymie the integration of Lighting and HVAC systems, and DOE activities focused on addressing them.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A tesselated probabilistic representation for spatial robot perception and navigation

The ability to recover robust spatial descriptions from sensory information and to efficiently utilize these descriptions in appropriate planning and problem-solving activities are crucial requirements for the development of more powerful robotic systems. Traditional approaches to sensor interpretation, with their emphasis on geometric models, are of limited use for autonomous mobile robots operating in and exploring unknown and unstructured environments. Here, researchers present a new approach to robot perception that addresses such scenarios using a probabilistic tesselated representation of spatial information called the Occupancy Grid. The Occupancy Grid is a multi-dimensional random field that maintains stochastic estimates of the occupancy state of each cell in the grid. The cell estimates are obtained by interpreting incoming range readings using probabilistic models that capture the uncertainty in the spatial information provided by the sensor. A Bayesian estimation procedure allows the incremental updating of the map using readings taken from several sensors over multiple points of view. An overview of the Occupancy Grid framework is given, and its application to a number of problems in mobile robot mapping and navigation are illustrated. It is argued that a number of robotic problem-solving activities can be performed directly on the Occupancy Grid representation. Some parallels are drawn between operations on Occupancy Grids and related image processing operations.

Elfes, Alberto↗

Safe2Ditch Steer-To-Clear Development and Flight Testing

This paper describes a series of small unmanned aerial system (sUAS) flights performed at NASA Langley Research Center in April and May of 2019 to test a newly added Steer-to-Clear feature for the Safe2Ditch (S2D) prototype system. S2D is an autonomous crash management system for sUAS. Its function is to detect the onset of an emergency for an autonomous vehicle, and to enable that vehicle in distress to execute safe landings to avoid injuring people on the ground or damaging property. Flight tests were conducted at the City Environment Range for Testing Autonomous Integrated Navigation (CERTAIN) range at NASA Langley. Prior testing of S2D focused on rerouting to an alternate ditch site when an occupant was detected in the primary ditch site. For Steer-to-Clear testing, S2D was limited to a single ditch site option to force engagement of the Steer-to-Clear mode. The implementation of Steer-to-Clear for the flight prototype used a simple method to divide the target ditch site into four quadrants. An RC car was driven in circles in one quadrant to simulate an occupant in that ditch site. A simple implementation of Steer-to- Clear was programmed to land in the opposite quadrant to maximize distance to the occupant’s quadrant. A successful mission was tallied when this occurred. Out of nineteen flights, thirteen resulted in successful missions. Data logs from the flight vehicle and the RC car indicated that unsuccessful missions were due to geolocation error between the actual location of the RC car and the derived location of it by the Vision Assisted Landing component of S2D on the flight vehicle. Video data indicated that while the Vision Assisted Landing component reliably identified the location of the ditch site occupant in the image frame, the conversion of the occupant’s location to earth coordinates was sometimes adversely impacted by errors in sensor data needed to perform the transformation. Logged sensor data was analyzed to attempt to identify the primary error sources and their impact on the geolocation accuracy. Three trends were observed in the data evaluation phase. In one trend, errors in geolocation were relatively large at the flight vehicle’s cruise altitude, but reduced as the vehicle descended. This was the expected behavior and was attributed to sensor errors of the inertial measurement unit (IMU). The second trend showed distinct sinusoidal error for the entire descent that did not always reduce with altitude. The third trend showed high scatter in the data, which did not correlate well with altitude. Possible sources of observed error and compensation techniques are discussed.

Petty, Bryan J.↗

A Global Building Occupant Behavior Database

This paper introduces a database of 34 field-measured building occupant behavior datasets collected from 15 countries and 39 institutions across 10 climatic zones covering various building types in both commercial and residential sectors. This is a comprehensive global database about building occupant behavior. The database includes occupancy patterns (i.e., presence and people count) and occupant behaviors (i.e., interactions with devices, equipment, and technical systems in buildings). Brick schema models were developed to represent sensor and room metadata information. The database is publicly available, and a website was created for the public to access, query, and download specific datasets or the whole database interactively. The database can help to advance the knowledge and understanding of realistic occupancy patterns and human-building interactions with building systems (e.g., light switching, set-point changes on thermostats, fans on/off, etc.) and envelopes (e.g., window opening/closing). With these more realistic inputs of occupants’ schedules and their interactions with buildings and systems, building designers, energy modelers, and consultants can improve the accuracy of building energy simulation and building load forecasting.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparing Occupant Light Exposure in Factory and Office Spaces

There is an increasing desire to provide healthy workplace environments that better serve people while minimizing the impact on the planet. Building recommendations help designers to incorporate the latest research and best practices, but translating research studies conducted in different settings to broader recommendations is challenging. This is particularly true for lighting, with researchers continuing to learn more about circadian, neuroendocrine, and neurobehavioral responses to light. The recommendations are regularly adjusting to incorporate the latest research as well as feedback from practitioners implementing these recommendations. There remains a need to better document the actual light exposure that people experience over the course of a day and across seasons, so that researchers can better understand the influence of light on people and recommendations can be refined. Thankfully, advances in sensor technology are making this more possible than ever. PNNL collaborated with ETC Inc. to understand actual occupant light exposure in factory and office spaces at ETC’s Headquarters in Middleton, WI. The primary building at ETC headquarters opened in 2004 and houses approximately 800 employees that contribute to central business functions, customer support, research and development, as well as the company’s primary 60,000 ft2 manufacturing facility. Vertical light exposure measurements including electric light and daylight were recorded in factory, research and development, and office work areas at occupant eye height. This document will focus on lighting measurements collected in six factory and office locations across work location, season, and time of day. Ultimately, detailed lighting measurements can be coupled with employee surveys to support development of satisfactory work environments.

42 ENGINEERING↗

Online and Offline Data Quality Monitoring for the Mu2e Calorimeter

This thesis presents the design, implementation, and validation of a calorimeter Data Quality Monitoring (DQM) toolchain for the Mu2e experiment at Fermilab. Mu2e searches for charged lepton flavor violation via coherent muon-to-electron conversion in the field of an aluminum nucleus, $\mu^- Al \rightarrow e^-Al$, a process whose observation would constitute clear evidence of physics beyond the Standard Model. Achieving target sensitivity requires stringent control of detector performance and data integrity during acquisition, as subtle issues in readout configuration, data formatting, or electronics behavior can compromise reconstruction and bias downstream analyzes. To address these challenges, this work develops a multi-layer DQM approach spanning both raw data validation and reconstructed digi-level diagnostics. At the low level, a fragment analysis component performs word- and bit-field decoding of calorimeter readout blocks, enabling sanity checks of the expected structure and producing detailed error and integrity statistics useful for commissioning and troubleshooting. At the digi level, the CaloDigiDQM analyzer is implemented within the art framework and transforms each CaloDigiCollection into a structured hierarchy of ROOT histograms designed for fast drill-down diagnostics. The module generates coherent monitoring views at global, disk, board, and channel granularity, including occupancy, waveform-derived features (baseline, RMS, peak amplitude and position), and left-right sensor consistency metrics. Detector-aware channel-to-electronics mapping is performed through the conditions system (CaloDAQMap), ensuring that diagnostics remain aligned with hardware identifiers used in operations. For end-to-end testing without reliance on live DAQ data, a synthetic CaloDigi producer is developed to generate realistic waveforms with controlled noise and pulse shapes. The resulting system supports both offline ROOT-file production and online operation, including optional histogram streaming through otsdaq via ots::HistoSender. This toolchain provides a practical and scalable foundation for calorimeter commissioning and stable data collection, enabling early detection of anomalies and reducing operational risk for Mu2e.

Vakulenko, Mark [Drew U.] (ORCID:0009000276197818)↗

An overview of data tools for representing and managing building information and performance data

Building information modeling (BIM) has been widely adopted for representing and exchanging building data across disciplines during building design and construction. However, BIM's use in the building operation phase is limited. With the increasing deployment of low-cost sensors and meters, as well as affordable digital storage and computing technologies, growing volumes of data have been collected from buildings, their energy services systems, and occupants. Such data are crucial to help decision makers understand what, how, and when energy is consumed in buildings—a critical step to improving building performance for energy efficiency, demand flexibility, and resilience. However, practical analyses and use of the collected data are very limited due to various reasons, including poor data quality, ad-hoc representation of data, and lack of data science skills. To unlock value from building data, there is a strong need for a toolchain to curate and represent building information and performance data in common standardized terminologies and schemas, to enable interoperability between tools and applications. This study selected and reviewed 24 data tools based on common use cases of data across the building life cycle, from design to construction, commissioning, operation, and retrofits. The selected data tools are grouped into three categories: (1) data dictionary or terminology, (2) data ontology and schemas, and (3) data platforms. The data are grouped into ten typologies covering most types of data collected in buildings. This study resulted in five main findings: (1) most data representation tools can represent their intended data typologies well, such as Green Button for smart meter data and Brick schema for metadata of sensors in buildings and HVAC systems, but none of the tools cover all ten types of data; (2) there is a need for data schemas to represent the basis of design data and metadata of occupant data; (3) standard terminologies such as those defined in BEDES are only adopted in a few data tools; (4) integrating data across various stages in the building life cycle remains a challenge; and (5) most data tools were developed and maintained by different parties for different purposes, their flexibility and interoperability can be improved to support broader use cases. Finally, recommendations for future research on building data tools are provided for the data and buildings community based on the FAIR principles to make data Findable, Accessible, Interoperable, and Reusable.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Overview of the Transport Rotorcraft Airframe Crash Testbed (TRACT) Full Scale Crash Tests

The Transport Rotorcraft Airframe Crash Testbed (TRACT) full-scale tests were performed at NASA Langley Research Center's Landing and Impact Research Facility in 2013 and 2014. Two CH-46E airframes were impacted at 33-ft/s forward and 25-ft/s vertical combined velocities onto soft soil, which represents a severe, but potentially survivable impact scenario. TRACT 1 provided a baseline set of responses, while TRACT 2 included retrofits with composite subfloors and other crash system improvements based on TRACT 1. For TRACT 2, a total of 18 unique experiments were conducted to evaluate Anthropomorphic Test Devices (ATD) responses, seat and restraint performance, cargo restraint effectiveness, patient litter behavior, and activation of emergency locator transmitters and crash sensors. Combinations of Hybrid II, Hybrid III, and ES-2 ATDs were placed in forward and side facing seats and occupant results were compared against injury criteria. The structural response of the airframe was assessed based on accelerometers located throughout the airframe and using three-dimensional photogrammetric techniques. Analysis of the photogrammetric data indicated regions of maximum deflection and permanent deformation. The response of TRACT 2 was noticeably different in the horizontal direction due to changes in the cabin configuration and soil surface, with higher acceleration and damage occurring in the cabin. Loads from ATDs in energy absorbing seats and restraints were within injury limits. Severe injury was likely for ATDs in forward facing passenger seats.

Annett, Martin↗

Engineering Company Recognized for Advanced Use of Lighting Sensors and Controls - Case Study: IMEG Corp, IL

This case study describes the implementation of several emerging lighting techniques at the new Chicago offices of IMEG Corp, an engineering and design consulting firm. IMEG collaborated with Pacific Northwest National Lab as part of a study to better understand the physiological and psychological impacts of advanced lighting strategies on occupant comfort, well-being, and energy savings. The project was recognized as part of DOE's Integrated Lighting Campaign.

integrated lighting, lighting, controls, tunable, ↗

Connecting the Dots: An Assessment of Cyber-risks in Networked Building and Municipal Infrastructure Systems

The buildings and city streets we walk down are changing. Driven by various data-driven use cases, there is increased interest in networking and integrating lighting and other building systems (e.g., heating, ventilation, and air conditioning (HVAC), security, scheduling) that were previously not internet-facing, and equipping them with sensors that collect information about their environment and the people that inhabit it. These data-enabled systems can potentially deliver improved occupant and resident experiences and help meet the U.S. Department of Energy (DOE) national energy and carbon reduction goals. Deploying connected devices new to being networked, however, is not without its challenges. This paper explores tools available to system designers and integrators that facilitate a cybersecurity landscape assessment – or more specifically the identification of threats, vulnerabilities, and adversarial behaviors that could be used against these networked systems. These assessments can help stakeholders shift security prioritization proactively toward the beginning of the development process.

cyber-risk assesment, adversarial behavior, MITRE ↗

Evaluation of thermostat location for multizone commercial building performance

In multi-zone buildings, it is often found that a single shared thermostat controls more than one conditioned zones. Although these shared zones are supposed to have similar thermal needs (e.g., cooling and heating load), in reality, they are not mainly due to different orientations, sizes of windows, occupancy, space types, etc. This can cause unnecessary energy waste or thermal discomfort for the occupants. How to quantify this impact in multizone buildings remains a research gap. Therefore, this study aims to evaluate the impact of different sensor (i.e., thermostat) locations for multizone commercial buildings through a comprehensive modeling study. Here, two different scenarios for the sensor locations were selected to evaluate the impact in terms of energy and thermal comfort. The scenario (1) is that one to five sensors distributed among the five zones, but the sensor readings from selected zones will be used for no-sensor zones, which is no-mean sensor scenario. The scenario (2) is that one to five sensors distributed among the five zones, but the average temperature from the shared zones will be used for each of the shared zones, which is a mean sensor scenario. The uncertainty analysis was performed for different sensor location scenarios.(a)The major findings from an energy perspective, for scenario (1), the differences of cooling energy go as high as 17% more or 12% less, compared with the baseline. For heating energy consumption, the discrepancies go as high as 51% more or 52% less, compared with baseline. For site energy consumption, the discrepancies go as high as 3.2% more or 3.2% less, compared with baseline. For fan energy consumption, the discrepancies go as high as 3.2% more or as low as 1.0% less, compared with baseline. For scenario (2), the discrepancies of cooling energy go as high as 3% more, or 0.5% less, compared with the baseline. For heating energy consumption, the discrepancies, are go as high as 10.1% more or as low as 3.0% less, compared with baseline. For site energy consumption, the discrepancies go as high as 1.3% more or 0.3% less, compared with baseline. For fan energy consumption, the discrepancies go as high as 3.1% more or as low as 1.0% less, compared with baseline.(b) In terms of the indoor thermal comfort, for the no-mean-sensor scenarios, the discrepancies of unmet hours for cooling mode can be as high as 1,200 h, compared with the baseline. The discrepancies of unmet hours for heating mode can be as high as 740 h, compared with the baseline. For the mean-sensor scenarios, the discrepancies of unmet hours for cooling mode can be as high as 750 h, compared with the baseline. The discrepancies of unmet hours for heating mode can be as high as 50 h, compared with the baseline.

42 ENGINEERING↗

Evaluation of the Second Transport Rotorcraft Airframe Crash Testbed (TRACT 2) Full Scale Crash Test

Two Transport Rotorcraft Airframe Crash Testbed (TRACT) full-scale tests were performed at NASA Langley Research Center's Landing and Impact Research Facility in 2013 and 2014. Two CH-46E airframes were impacted at 33-ft/s forward and 25-ft/s vertical combined velocities onto soft soil, which represents a severe, but potentially survivable impact scenario. TRACT 1 provided a baseline set of responses, while TRACT 2 included retrofits with composite subfloors and other crash system improvements based on TRACT 1. For TRACT 2, a total of 18 unique experiments were conducted to evaluate ATD responses, seat and restraint performance, cargo restraint effectiveness, patient litter behavior, and activation of emergency locator transmitters and crash sensors. Combinations of Hybrid II, Hybrid III, and ES-2 Anthropomorphic Test Devices (ATDs) were placed in forward and side facing seats and occupant results were compared against injury criteria. The structural response of the airframe was assessed based on accelerometers located throughout the airframe and using three-dimensional photogrammetric techniques. Analysis of the photogrammetric data indicated regions of maximum deflection and permanent deformation. The response of TRACT 2 was noticeably different in the longitudinal direction due to changes in the cabin configuration and soil surface, with higher acceleration and damage occurring in the cabin. Loads from ATDs in energy absorbing seats and restraints were within injury limits. Severe injury was likely for ATDs in forward facing passenger seats.

Annett, Martin↗

Fault Dataset Development for VAV Terminal Units: Damper and Airflow Sensor Faults

This report analyzes field data to understand the impact of faults in variable air volume (VAV) terminal units on building indoor conditions and heating, ventilation, and air-conditioning (HVAC) system operations. The Oak Ridge National Laboratory (ORNL) team conducted field tests at the commercial building test facility known as ORNL’s Flexible Research Platform (FRP) building. Two specific faults-damper malfunctions and airflow sensor inaccuracies- were implemented, as these are common faults in VAV terminal units and can significantly impact HVAC system performance by increasing energy consumption, causing occupant discomfort, and raising operational costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Emergency Radiation Dose Rate Monitoring During Prolonged Armed Conflict

The 2022 Russian full-scale invasion of Ukraine has introduced unprecedented challenges for the nuclear power generation and radiological safety communities, including occupation and disturbance of highly-contaminated areas, occupation of a nuclear power plant, and strikes near and within boundaries of nuclear sites. The war has necessitated the implementation of a supplementary dose rate sensor network to provide resilient measurement data for public protection and leadership awareness. This paper discusses the implementation of such a system, the factors determining what equipment is best suited for the purpose, and practical factors regarding deployment of the system and data management. The crucial factors for operating a supplementary dose rate sensing network are backup power and communications options for dose rate sensors to make the network resilient to the effects of military operations. The most important implementation factor is to plan for extended operations beyond those typically considered for emergency response given the unpredictable nature of warfare.

resilience↗

Targeted Energy Management System Toolset

TEMST integrates advanced sensor systems with advanced computational intelligence, e.g. neural networks and fuzzy arithmetic, to enable effective energy management while minimizing negative human comfort consequences and promoting improved occupant satisfaction. Preliminary work suggests that energy cost reductions above ten percent are easily achievable. In addition to optimizing existing Energy Management Systems (EMS), the proposed toolset will be both resilient and secure in order to proactively maintain a safe level of operational normalcy in response to anomalies and malicious actions.

Rieger, CraigG.↗